• 제목/요약/키워드: Geometric Flow

검색결과 592건 처리시간 0.024초

변형격자계를 이용한 3차원 날개 주변의 비정상 유동 해석 (THE COMPUTATION OF UNSTEADY FLOWS AROUND THREE DIMENSIONAL WINGS ON DYNAMICALLY DEFORMING MESH)

  • 유일용;이승수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.34-37
    • /
    • 2009
  • Deforming mesh should be used when bodies are deforming or moving relative to each other due to the presence of aerodynamic forces and moments. Also, the flow solver for such a flow problem should satisfy the geometric conservation law to ensure the accuracy of the solutions. In this paper, a RANS(Reynolds Averaged Navier-Stokes) solver including automatic mesh capability using TFI(Transfinite Interpolation) method and GCL is developed and applied to flows induced by oscillating wings with given frequencies. The computations are performed both on deforming meshes and on rigid meshes. The computational results are compared with experimental data, which shows a good agreement.

  • PDF

변형격자계를 이용한 3차원 날개 주변의 비정상 유동 해석 (THE COMPUTATION OF UNSTEADY FLOWS AROUND THREE DIMENSIONAL WINGS ON DYNAMICALLY DEFORMING MESH)

  • 유일용;이병권;이승수
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.37-45
    • /
    • 2010
  • Deforming mesh should be used when bodies are deforming or moving relative to each other due to the presence of aerodynamic forces and moments. Also, the flow solver for such a flow problem should satisfy the geometric conservation law to ensure the accuracy of the solutions. In this paper, a RANS(Reynolds Averaged Navier-Stokes) solver including automatic mesh capability using TFI(Transfinite Interpolation) method and GCL is developed and applied to flows induced by oscillating wings with given frequencies. The computations are performed both on deforming meshes and on rigid meshes. The computational results are compared with experimental data, which shows a good agreement.

Coronary Artery Numerical Flow Analysis for Determination of Bypass Graft Geometric Parameters

  • Kim, Hyung-Min;Kim, Woong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.905-912
    • /
    • 2005
  • A computational investigation of blood flow in a coronary artery grafted by artificial bypass was performed to determine such geometric parameters as the curvature of radius, approach length, and angle of end-to-side anastomosis. Transient flow features in the host artery were computed using FVM and SIMPLE algorithms. We compared flow distributions and wall shear stresses in two simple models, planar and non-planar, and confirmed that the non-planar bypass model was more conducive to suppressing intimal hyperplasia. Our non-planar model with $60^{\circ}$ of anastomosis and a 1.0 diameter approach length and radius of curvature predicts a relatively small, spatially-extended high-OSI (>0.01) zone, as well as an increased average wall shear stress on this zone.

NUMERICAL SOLUTIONS OF AN UNSTEADY 2-D INCOMPRESSIBLE FLOW WITH HEAT AND MASS TRANSFER AT LOW, MODERATE, AND HIGH REYNOLDS NUMBERS

  • AMBETHKAR, V.;KUSHAWAHA, D.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제21권2호
    • /
    • pp.89-107
    • /
    • 2017
  • In this paper, we have proposed a modified Marker-And-Cell (MAC) method to investigate the problem of an unsteady 2-D incompressible flow with heat and mass transfer at low, moderate, and high Reynolds numbers with no-slip and slip boundary conditions. We have used this method to solve the governing equations along with the boundary conditions and thereby to compute the flow variables, viz. u-velocity, v-velocity, P, T, and C. We have used the staggered grid approach of this method to discretize the governing equations of the problem. A modified MAC algorithm was proposed and used to compute the numerical solutions of the flow variables for Reynolds numbers Re = 10, 500, and 50000 in consonance with low, moderate, and high Reynolds numbers. We have also used appropriate Prandtl (Pr) and Schmidt (Sc) numbers in consistence with relevancy of the physical problem considered. We have executed this modified MAC algorithm with the aid of a computer program developed and run in C compiler. We have also computed numerical solutions of local Nusselt (Nu) and Sherwood (Sh) numbers along the horizontal line through the geometric center at low, moderate, and high Reynolds numbers for fixed Pr = 6.62 and Sc = 340 for two grid systems at time t = 0.0001s. Our numerical solutions for u and v velocities along the vertical and horizontal line through the geometric center of the square cavity for Re = 100 has been compared with benchmark solutions available in the literature and it has been found that they are in good agreement. The present numerical results indicate that, as we move along the horizontal line through the geometric center of the domain, we observed that, the heat and mass transfer decreases up to the geometric center. It, then, increases symmetrically.

판형 열교환기의 열전달성능 손실 없이 유동방향 길이를 축소하는 방법 (A Method to Reduce Flow Depth of a Plate Heat Exchanger without a Loss of Heat Transfer Performance)

  • 송귀은;이대영
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.129-136
    • /
    • 2006
  • Optimal design of an air-to-liquid finned plate heat exchanger is considered theoretically in this study. Based on existing correlations for the pressure loss and the heat transfer in channel flows, the optimal configuration of the plate heat exchanger including the optimal plate pitch and the optimal fin pitch is obtained to maximize the heat transfer within the limit of the pressure drop for a given flow depth of the plate heat exchanger. It is found that the optimal fin pitch is about one ninth of the optimal plate pitch. In the optimal configuration, the flow and thermal condition in the channels is just at the boundary between the laminar developing and laminar fully developed states. It is also found when reducing the flow depth of plate heat exchangers for compactness, the heat transfer performance can be maintained exactly the same if the geometric parameters such as the plate thickness, plate pitch, fin thickness, and fin pitch are reduced proportional to the square root of the flow depth as long as the flow keeps laminar within the heat exchangers.

기하학적 비선형성을 고려한 유체를 수송하는 반원관의 면내운동에 대한 진동 해석 (Vibration Analysis for the In-plane Motions of a Semi-Circular Pipe Conveying Fluid Considering the Geometric Nonlinearity)

  • 정진태;정두한
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.2012-2018
    • /
    • 2004
  • The vibration of a semi-circular pipe conveying fluid is studied when the pipe is clamped at both ends. To consider the geometric nonlinearity, this study adopts the Lagrange strain theory for large deformation and the extensible dynamics based on the Euler-Bernoulli beam theory for slenderness assumption. By using the Hamilton principle, the non-linear partial differential equations are derived for the in-plane motions of the pipe, considering the fluid inertia forces as a kind of non-conservative forces. The linear and non-linear terms in the governing equations are compared with those in the previous study, and some significant differences are discussed. To investigate the dynamic characteristics of the system, the discretized equations of motion are derived from the Galerkin method. The natural frequencies varying with the flow velocity are computed from the two cases, which one is the linear problem and the other is the linearized problem in the neighborhood of the equilibrium position. Finally, the time responses at various flow velocities are directly computed by using the generalized-$\alpha$ method. From these results, we should consider the geometric nonlinearity to analyze dynamics of a semi-circular pipe conveying fluid more precisely.

왕복동형 압축기의 경사진 원판형 밸브리드와 밸브 시트의 기하학적 파라미터에 대한 압력분포 측정 및 유동해석 (Flow Analysis and Measurement of Pressure Distribution along Inclinde Circular Valve Reeds and Valve Seat Geometric Parameters of Reciprocating Compressor)

  • 박종호;윤정;김태민;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.828-833
    • /
    • 2003
  • This work analyzes the effects of the independent variation of different geometric dimensions of compressor valves on the effective flow and force areas using a circular valve plate, such as different geometry of the valve seat, and the valve reed is opened and closed by pressure pulsation, the flow characteristic of the refrigerant passing the valve is very important. In the present study, a circular disk with inclination is assumed to be the valve reed of a reciprocating compressor and numerical analysis of three dimensional velocity fields are performed for theradial flow through the valve model. The effective flow and force area which are required to predict the efficiency of the valve are required to predict the efficiency of the valve are measured and compared with the numerical analysis in this research.

  • PDF

기포펌프의 형상 및 작동 조건에 따른 전산유동해석 (Computational Flow Analysis with Geometric and Operating Conditions of Air Lift Pump)

  • 강건한;김성초;최종욱
    • 한국가시화정보학회지
    • /
    • 제18권2호
    • /
    • pp.18-27
    • /
    • 2020
  • Air lift pump operated by buoyancy is mainly used for the continuous circulation and the purification of fluids. In this study, the computational flow analysis has been performed with the geometric and operating conditions of the air lift pump. The numerical data from the analysis have been verified by comparing with the previous experimental data. The following results are obtained which advance the efficiency of the air lift pump. As the submergence length of pipe increases and the pipe length over the water surface decreases, the non-dimensional mass flow ratio increases in both cases. When the position of the air injection hole is within the pipe, the circulation range of the surrounding fluid becomes widened with the distance between the air injection hole and the pipe inlet relatively becoming narrower. It is more efficient both when the air injection velocity is at 10 m/s and at 15 m/s, and when the diameter of the pipe with holes is doubled near the water surface. It is expected that these results can be provided as fundamental data for operating the air lift pump.

유동망 시스템 해석을 위한 경계처리에 대한 보존형 유한체적법 (CONSERVATIVE FINITE VOLUME METHOD ON BOUNDARY TREATMENTS FOR FLOW NETWORK SYSTEM ANALYSES)

  • 홍석우;김종암
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.19-26
    • /
    • 2008
  • From numerical point of view on flow network system analyses, stagnation properties are not preserved along streamlines across geometric discontinuities. Hence, GJM and DTM using ghost cell and thermodynamic relations are developed to preserve the stagnation enthalpy for the boundaries, such as the interfaces between junction and branches and the interface between two pipes of different cross-sections in serial pipelines. Additionally, the resolving power and efficiencies of the 2nd order Godunov type FV schemes are investigated and estimated by the tracing of the total mechanical energy during calculating rapid transients. Among the approximate Riemann solvers, RoeM is more suitable with the proposed boundary treatments especially for junction than Roe's FDS because of its conservativeness of stagnation enthalpy across geometric discontinuities.

  • PDF

유동망 시스템 해석을 위한 경계처리에 대한 보존형 유한체적법 (CONSERVATIVE FINITE VOLUME METHOD ON BOUNDARY TREATMENTS FOR FLOW NETWORK SYSTEM ANALYSES)

  • 홍석우;김종암
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.19-26
    • /
    • 2008
  • From numerical point of view on flow network system analyses, stagnation properties are not preserved along streamlines across geometric discontinuities. Hence, GJM and DTM using ghost cell and thermodynamic relations are developed to preserve the stagnation enthalpy for the boundaries, such as the interfaces between junction and branches and the interface between two pipes of different cross-sections in serial pipelines. Additionally, the resolving power and efficiencies of the 2nd order Godunov type FV schemes are investigated and estimated by the tracing of the total mechanical energy during calculating rapid transients. Among the approximate Riemann solvers, RoeM is more suitable with the proposed boundary treatments especially for junction than Roe's FDS because of its conservativeness of stagnation enthalpy across geometric discontinuities.

  • PDF