• 제목/요약/키워드: Generator Protection

검색결과 270건 처리시간 0.028초

LAN을 이용한 분산전원 연계 계통의 보호 (LAN-Based Protective Relaying for Interconnect Protection of Dispersed Generators)

  • 정태영;백영식
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.491-497
    • /
    • 2007
  • As dispersed generators was driven in condition interconnecting with utility, it could cause a variety of new effects to the original distribution system that was running as considered only the one-way power flow. Therefore, the protection devices that is builted in distribution system should be designed to be able to operate with disposing of not only a fault of the generator, but also utility condition. Especially, the fault of the feeder interconnected with Dispersed Generator can cause the islanding phenomenon of open DG(Dispersed Generators). This phenomenon has many problems such as a machinery damage, electricity qualify degradation and a difficulty of the system recovery. In the fault therefore, we must separate Dispersed Generator from the system quickly. In this paper, for the fault classification of the interconnected DG and the outside feeder we judge the fault of the interconnected DG and the outside feeder in HMI through data provided by IED(Intelligent Electronic Device) on the network and decide whether it operates or not by sending the result to each relay.

154kV 계통 결상시 발전기 영향 분석 (The Analysis about Effect of Generator on Open Phase in 154kV Line)

  • 옥연호;이은웅;변일환;김인수;신강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.73-74
    • /
    • 2008
  • When 154kV Line is opened, what happens on generator? What protection relay operates? Therefore through studying on this trouble, the operator will handle well on re-troubling and we would like to re-examine thoroughly the co-ordination of generator and transformer protection system.

  • PDF

부안 S/S 변산 D/L(2728 02) 공급구역을 대상으로 한 풍력발전시스템 계통연계 시 보호협조 방안 (A Study on Stable Operating for Buan S/S Byunsan D/L (2728 02) Power Distribution Area Connected with Wind Power Generator)

  • 장미혜;신백식;송원진;김영민;김동용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.508-509
    • /
    • 2008
  • A creation of large and small scale wind farm was considered to proper already, as according to real Jeonbuk Saemangeum project. A grow larger to be construction of the new and renewable energy thema park as well as creation possibility of large scale wind farm afterward. Therefore, in this paper was proposed a counterplan on D/L protection cooperation of Buan S/S Byunsan D/L (2728 02) power distribution line in case of connected with wind power generator.

  • PDF

초전도발전기의 계자권선 보호저항 선정에 관한 연구 (Protection Resistance Determination for Field Winding in Superconducting Generator)

  • 강준선;나완수;권영길;손명환;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.238-240
    • /
    • 1999
  • In this paper, the protection resistance determination for the field winding in superconducting generator is suggested. To protect the field winding in a generator, they usually use the external resistance to decrease the field current more rapidly when quench occurs in the winding. Since the field winding is actually separated into four sections (magnets), we have choices to insert 1, 2, and 4 external resistances. For each case, the current decay and the voltages across e winding are calculated, and we can choose the best external resistance.

  • PDF

발전기의 불평형 검출을 위한 디지털 역상 계전 알고리즘 (Digital Negative Sequence Relay Algorithm for Detection of Unbalanced State in a Generator)

  • 박철원
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.198-203
    • /
    • 2013
  • There are conditions that can be unbalanced three phase currents in a large generator by untransposed lines, unbalanced loads, unsymmetrical faults, and open phases. The unbalanced conditions can producing negative sequence components of current that induce two times frequence current in the surface of the rotor, the retaining rings, the slot wedges in the field windings. These rotor currents make the rotor rapidly overheat, so the rotor can cause substantial damage in a very short time. This paper presents the digital negative sequence relay algorithm for unbalanced protection in a generator. The proposed algorithm was tested by using collected current signals on PSCAD/EMTDC considering a hydro turbine based generator control system. It can be seen that the proposed relaying by negative sequence current is useful for detection of unbalanced state of large generator.

계통동요 제어를 위한 UPFC제어기 (UPFC Control for Power System Damping Reduction)

  • 윤종수;윤용범;문건우;윤석호;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.256-258
    • /
    • 1998
  • This paper presents a control system design for the UPFC of FACTS devices by optimal control scheme to enhance small-signal stability in the Power system. The feature of this UPFC controller is coordinated with generator exciter controller(AVR, PSS) to improve the total Power system stability and performance.

  • PDF

발전기 보호제어를 위한 Bay Controller 설계에 관한 연구 (A Study on the Design of the Bay Controller for Generator Protection and Control)

  • 장낙원;우천희;이성환
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.46-55
    • /
    • 2008
  • In this paper, we designed the bay control unit that is based on the microprocessors and integrates with the new technology of electrical, electronic, and mechanical fields. Nowadays the customers have required much more integrated multi-protection relay, monitoring, control devices and power management for better and easier maintenance, performance, electrical system analysis and communication according to new trend of switchboard This bay controller supplies those requirements of customers with easy handling and operation. This bay controller provides a graphic display with rear-lit liquid crystal LCD and push buttons as kinds of HMI(Human Machine Interface). This bay controller provides the parameter setting program, control setting program, various editors and fault recording and analysis program on Windows/95/98/NT/2000/XP for HMI. In addition, this bay controller can be set manually and this manual setting function helps user to interface easily.

원자로 스팀 제너레이터 홀의 수리 및 자동 검사를 위한 원격제어 로봇시스템 설계 (Design of a Remotely-Controlled Robot System for Automatic Inspection and Repair of Steam Generator Hole in Nucuear Power Plant)

  • 김종규
    • 한국생산제조학회지
    • /
    • 제9권2호
    • /
    • pp.125-137
    • /
    • 2000
  • In this paper we propose a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the proposed vision system. Performance of proposed digital vision system is illustrated by simulation and experiment for similar steam generator moldel.

  • PDF

원전 증기 발생기 세관 검사용 비젼시스템 개발에 관한 연구 (A study on development of a vision system for the test of steam generator holes in nuclear power plants)

  • 왕한홍;김종수;한성현;심상한
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.101-104
    • /
    • 1996
  • In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. In this paper, it is proposed a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. Digital signal processors are used in implementing real time recognition and examination of steam generator holes in the proposed vision system. Performance of proposed digital vision system is illustrated by experiment for similar steam generator model.

  • PDF

퍼지 소속 함수에 기초한 원전 증기발생기 검사용 실시간 비젼시스템 (Real Time Vision System for the Test of Steam Generator in Nuclear Power Plants Based on Fuzzy Membership Function)

  • 왕한흥
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1996년도 추계학술대회 논문
    • /
    • pp.107-112
    • /
    • 1996
  • In this paper it is proposed a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the preposed vision system, Performance of proposed digital vision system is illustrated by experiment for similar steam generator model.

  • PDF