• 제목/요약/키워드: General connection

검색결과 666건 처리시간 0.026초

선택적 p-분배에 의한 적응적 유한 요소법 (Adaptive Finite Element Method by Selective p-Distribution)

  • 조준형;우광성;박진환;안재석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.288-295
    • /
    • 2003
  • An adaptive procedure in finite element analysis is presented by p-refinement of meshes in conjunction with a posteriori error estimator that is based on the recovery technique. In case of the recovery technique, the SPR(superconvergent patch recovery) approach has been modified for p-adaptive mesh refinement. The strategy of finding a nearly optimal distribution of polynomial degrees on a fixed finite element mesh is discussed such that a particular element has to be refined automatically to obtain an acceptable level of accuracy by increasing p-levels non-uniformly. To verify the proposed algorithm, the limit value approach is proposed which utilizes the exact strain energy computed from the extrapolation equation. A new pre-processor is developed for the p-version finite element program in which the vector graphic editor is used for the automatic generation of node connection and coordinate by halfedge solid data structure according to uniform or nonuniform p-distribution. The general 2-D algorithm is also developed to generate face modes and internal modes in accordance with different mesh types. The quality of the error estimator is investigated with the help of two mumerical examples. The results show that the sequences of p-distributions obtained by the proposed error indicator closely follow the optimal trajectory.

  • PDF

지역난방 공동주택에서 급탕 2단 열교환기 용량의 적정성 평가에 관한 연구 (A Study on the Design Capacity of 2-stage Hot Water Heat Exchanger in Apartment Housings with District Heating System)

  • 사기용;정광섭;김영일;나채문;김성민;김상호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1037-1042
    • /
    • 2009
  • In connection with a recent research project dealing with heating system in apartment buildings by district heating, it was realised that in general very little information on the actual performance of heating and hot water systems in apartment buildings has been documented. In order to improve of district heating systems, a prediction of the heat demand first needs to be determined before a production plan. this is hot water heat system developed in this paper. this is also analyzed relation heat load with preheat load in hot water heating exchanger system.

  • PDF

잇솔질 후 양칫물 온도가 구취에 미치는 영향 (The effect of the temperature of rinsing water after brushing on oral malodor)

  • 최우양;김현숙
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.465-470
    • /
    • 2012
  • Objectives : In general, the active of volatile compounds which become usually known as the principal ingredient of bad breath is closely connected with temperature. In this study, an investigation was made into the correlation between oral malodor and the temperature of rinsing water. Specifically, an analysis was made of saliva in rinsing water with relation to amount, flow and pH. In addition, a calculation was made of O'Leary index. The results are expected to be basic data for oral malodor reduction plans. Methods : A total of 30 women who are in their 20s without any systemic disease and teeth braces and non-pregnant were chosen for the study. The research was carried during 3 weeks from 28 Mar to 11 Apr in 2011. Results : Saliva was not significantly affected by the temperature of rinsing water, in connection with saliva amount, saliva flow and saliva pH. The O'Leary index and oral malodor was the highest in warm water, but the subjects preferred rinsing with cold water. Conclusions : In conclusion, oral malodor was found to be reduced in inverse proportion to the temperature of rinsing water. Thus, it is recommended to rinsing water with warm water after tooth brushing.

바이오필터와 황-석회석을 이용한 단일흐름 공정에서의 질산화와 탈질 연구 (A Study on Nitrification and Denitrification in Biofilter & Sulfur- Limestone Single Stream Process)

  • 김태규
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.469-477
    • /
    • 2006
  • When denitrification was connected with a single stream process by using biofilter and sulfur-limestone, it was found that such connection enabled highly efficient nitrification without special unit operation of microorganisms or injection of external carbon sources which is being shown in general biological treatment processes. It was observed that in the trickling filter bed, decomposition of organic substances and highly efficient nitrification by both the forced pressure feed trickling and the air fan were simultaneously done. In the denitrification tank where sulfur-limestone was mixed at a certain ratio, limestone was used by autotrophic microorganisms as a source of supply for alkalinity, and nitrate $NO_{3}^{-}$-N was denitrified into nitrogen gas. And in the sulfur-limestone autotrophic denitrification, $NO_{3}^{-}-N\;or\;NO_{2}^{-}-N$ was denitrified as a sulfur compound in reduction state was oxidized into a final output of $SO_{4}^{-2}$. The mean concentration of the discharge water was 8.6 mg/l for T-N and 0.8 mg/l for T-P, respectively, and their mean treatment efficiency was 79.2% and 80.8%, respectively. Implementing highly efficient denitrification without injection of an external organic carbon source or internal return, it is concluded that the proposed process is suitable for a sewerage in a small village with the merits of low power consumption and easy maintenance.

Ni-YSZ Core-shell에서 Shell의 두께에 따른 SOFC의 출력특성 (Performance of SOFC According to Thickness of Shell with Ni-YSZ Core-shell)

  • 최병현;홍선기;지미정
    • 한국수소및신에너지학회논문집
    • /
    • 제28권6호
    • /
    • pp.663-668
    • /
    • 2017
  • SOFC anode fabricated core-shell using machano-fusion method using core with submicron size Ni, nano size YSZ for shell. Using prepared core-shell, depending on the thickness of the shell, we studied how the characteristics of sintering and SOFC cell change by sintering the anode. The Ni-YSZ core-shell has a Ni core of 0.5 to $1.2{\mu}m$ over 2 to 7 YSZ of 15 to 20 nm is, and as the high speed mixing time increases, the YSZ number increases and the shell thickness becomes uniform increased. When the fuel electrode is manufactured with core-shell, it has superior sintering property, has grain of uniform size compared with the one synthesized by general mixing, the falling path is short, the conductors (electrons and ions) connection is excellent, the electrical conductivity has become excellent. The thicker the shell, the lower the electrical conductivity. When the thickness of shell ranged from 46 to 139 nm and 61 to 81 nm, the performance was the highest and the ASR was the smallest.

난방을 비롯한 공기조화의 자연조절 방식과 현대적 응용에 관한 고찰 (A Study on the Passive Principle and its Practical Application of Air-conditioning System)

  • 박순관
    • 한국건축시공학회지
    • /
    • 제4권2호
    • /
    • pp.105-112
    • /
    • 2004
  • The objective of this study is to observe today's situation and direction in relation with the natural air-conditioning and heating system to expand the architectural utilization of natural management for human comfort and energy conservation in architectural design. Also this study to provide the fundamental knowledge and. design-techniques on environment-friendly architecture in connection with 'natural idea in architecture'. In accordance with this intention, this thesis is composed of the following contents : 1) to understand the fundermental concepts about natural air-conditioning and heating system, 2) to review the traditional characteristics in Korean and Southeast Asian architecture related to natural air-conditioning and heating system, 3) to examine modern design-techniques in relation with natural air-conditioning and heating system in the selected area, 4) to attempt to synthesize the whole situation. Environment-friendly architecture using natural ideas and design-techniques in architecture is very important architectural aspect in a current architecture, also for the future. In spite of general considerations, it is expected that this study is use to understand the principle and practical application of natural air-conditioning and heating system in architectural design.

임베디드 OS에서의 역할기반 접근제어 적용 (Appplication of Role-based access control in Embedded OS)

  • 임재덕;은성경;김기영;김정녀;이철훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.163-165
    • /
    • 2007
  • Recently, the security requirements of the embedded system which were not considered when the embedded system is independently deployed are being increased because the embedded system is connected to an internet. The connection to the internet of embedded system is the meaning that it is exposed to the various kinds of external attack and can be a victim to these attacks in anytime. Particularly, it is trend that the user-related information is stored into the personal terminals and/or electrical appliances such as PDA, home gateway for home network, settop boxes and so on. So it is needed the security mechanism which protects the user information from the malicious accesses. Accordingly, the coverage of the system security is being expanded from the general server to the embedded system. And it is not enough that the embedded system supports only its inherent functions and it becomes the essential element to provide the security function to the embedded system. This paper applies the RBAC(role-based access control) function to the embedded linux OS and tries to strengthen the security of the embedded linux OS. RBAC is implemented as a loadable kernel module with LSM(Linux Security Module) security framework for user's flexibility.

  • PDF

매개변수해석을 통한 Extradosed PSC 박스 거더교의 구조특성 분석 (Parametric Study on the Structural Characteristics of Extradosed PSC Box Girder Bridges)

  • 정지승;전준창;박진석
    • 한국안전학회지
    • /
    • 제31권1호
    • /
    • pp.74-80
    • /
    • 2016
  • In this paper, structural characteristics for an extradosed prestressed concrete box girder bridge are investigated in terms of selective parameters. These parameters are mainly associated with the structural details of the extradosed bridge and derived from currently available literatures regarding previous design drawings. The analyses have been carried out using general-purpose structural analysis program, RM-Space Frame. The parameters evaluated for the present study represent the most salient features of the extradosed bridge and are as follows; 1) span length ratio(side-span length to center-span length), 2) boundary condition of girder, 3) height of pylon, 4) anchorage location of external cables and 5) girder stiffness. The analytical predictions indicate that span length ratio and pylon height are reasonably adequate in the range of 0.55 to 0.60 and $L_m/8$ to $L_m/12$ respectively for the bridge under consideration. Also, demonstrated is the boundary condition of girder, in which rigid-connection details give more efficiency than the continuous details. In addition, considering structural characteristics of the extradosed bridge, it is desirable that the girder stiffness should be determined by the stress range of external cables rather than bending moment of girder.

Deflection calculation method on GFRP-concrete-steel composite beam

  • Tong, Zhaojie;Song, Xiaodong;Huang, Qiao
    • Steel and Composite Structures
    • /
    • 제26권5호
    • /
    • pp.595-606
    • /
    • 2018
  • A calculation method was presented to calculate the deflection of GFRP-concrete-steel beams with full or partial shear connections. First, the sectional analysis method was improved by considering concrete nonlinearity and shear connection stiffness variation along the beam direction. Then the equivalent slip strain was used to take into consideration of variable cross-sections. Experiments and nonlinear finite element analysis were performed to validate the calculation method. The experimental results showed the deflection of composite beams could be accurately predicted by using the theoretical model or the finite element simulation. Furthermore, more finite element models were established to verify the accuracy of the theoretical model, which included different GFRP plates and different numbers of shear connectors. The theoretical results agreed well with the numerical results. In addition, parametric studies using theoretical method were also performed to find out the effect of parameters on the deflection. Based on the parametric studies, a simplified calculation formula of GFRP-concrete-steel composite beam was exhibited. In general, the calculation method could provide a more accurate theoretical result without complex finite element simulation, and serve for the further study of continuous GFRP-concrete-steel composite beams.

Behavior of UHPC-RW-RC wall panel under various temperature and humidity conditions

  • Wu, Xiangguo;Yu, Shiyuan;Tao, Xiaokun;Chen, Baochun;Liu, Hui;Yang, Ming;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • 제9권5호
    • /
    • pp.459-467
    • /
    • 2020
  • Mechanical and thermal properties of composite sandwich wall panels are affected by changes in their external environment. Humidity and temperature changes induce stress on wall panels and their core connectors. Under the action of ambient temperature, temperature on the outer layer of the wall panel changes greatly, while that on the inner layer only changes slightly. As a result, stress concentration exists at the intersection of the connector and the wall blade. In this paper, temperature field and stress field distribution of UHPC-RW-RC (Ultra-High Performance Concrete - Rock Wool - Reinforced Concrete) wall panel under high temperature-sprinkling and heating-freezing conditions were investigated by using the general finite element software ABAQUS. Additionally, design of the connection between the wall panel and the main structure is proposed. Findings may serve as a scientific reference for design of high performance composite sandwich wall panels.