• Title/Summary/Keyword: General X-ray

Search Result 551, Processing Time 0.028 seconds

A study on radiation safety education, knowledge, and practice in using portable intraoral X-ray equipment of dental hygienist's (치과위생사의 이동형 구내방사선 촬영에 관한 방사선 방어 교육, 지식, 수행에 관한 연구)

  • Ryu, Jeong-Min;Kang, Bo-Sun;Kim, Seol-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.6
    • /
    • pp.1053-1065
    • /
    • 2017
  • Objectives: The purpose of this study is to evaluate radiation safety education, knowledge and practice of dental hygienists in using handheld portable intraoral X-ray equipment and to suggest the need for radiation safety education in using handheld portable intraoral X-ray equipment. Methods: We surveyed 223 dental hygienists from July, 2017 to August in the dental clinics of Daejeon, Seoul and Gyeonggi area. Results: Radiation safety educational experience was higher in a year's career (72.9%), than 3 years experience (32.5%) (p<0.05). 82.7% of dental clinic workers took university education for radiation safety education while 55.6% of dental hospital workers took company training (p<0.05). More than 70% of the subjects did not have experience of radiation safety education about using portable intraoral X-ray. Radiation safety knowledge was highest in a year's career (p<0.05). The cumulative dose, radiation sensitivity, and lead defense knowledge were high in all subjects, but knowledge related to scattering radiation and scattering radiation sources was low. Practice of portable intraoral X-ray safety was significantly lower than knowledge. Conclusions: Knowledge of portable intraoral radiography safety is available, but performance is poor. Even with the small amount of radiation exposure, the risk is perceivable. There is a need to actively utilize the provided radiation protection products. In order to do this, efforts should be made to improve knowledge and performance of radiation safety through not only college education but also postemployment training.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

Parsec-scale radio properties of the X-ray selected AGN sample

  • Baek, Junhyun;Chung, Aeree;Schawinski, Kevin;Oh, Kyuseok;Wong, Ivy;Ricci, Claudio;Koss, Michael;Mushotzky, Richard;Smith, Krista
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.73.4-74
    • /
    • 2017
  • We report preliminary results from our radio study of X-ray selected complete AGN sample in the Local Universe (z < 0.05), using the KVN/KaVA. The main goal is to probe the parsec-scale radio properties of the X-ray selected AGNs, which has not been done systematically before. The BASS (Burst Alert Telescope AGN spectroscopic survey) sample from the Swift-BAT hard X-ray all-sky survey is the least biased AGN sample against dense gas/torus obscurations compared to optically selected AGNs, providing ideal targets to study the general properties of local AGNs in radio wavelengths. Combining our radio data with BASS X-ray/optical measurements, we will probe the relations of radio powers with the fundamental quantities of black holes such as bolometric luminosity, black hole mass, and Eddington ratio. Using these relations, we will discuss our current understandings of how accretions and jets of local AGNs are linked together, and what they imply for the nature of our AGN sample.

  • PDF

Analysis of Space Radiation Dose Rate using portable X-ray Generating Device for Abdomen (이동형 X-ray 발생장치를 이용한 복부 촬영 시 공간 선량률에 관한 연구)

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.97-101
    • /
    • 2010
  • This experimental study is carried out one of the General Hospital in Kyungbok providence. Abdomen Phantom being located Anterior-posterior(AP) position on portable bed, and the portable X-ray generating device was placed the phantom at $-90^{\circ}$ direction. The experiment were set 65 kVp, 10 mAs, $10{\times}10\;cm^2$, 100 cm(FOD) for the measurement. Digital proportional counting tube survey meter was used for measuring the space scatter dose. Measurement points of horizontal distribution was set up at $30^{\circ}$ interval by increasing 50 cm radius of upside, downside, left and right. Vertical distribution of measurement points were set up for the vertical plane with a radius of at $30^{\circ}$ intervals with 50cm increments. It is concluded that longer distance from the soure of X-ray significantly decrease radiation dose to the patient and use of the radiation protection device should be applied in clinical practice to reduce dose to the patient.

  • PDF

Terahertz Transmission Images For Medical Applications (테라헤르쯔 전자파 의료 영상 기술)

  • Jaeyoung Ryu;Yuchul Jung;Seungyong Baek;Lee, Jongjoo;Kim, Joungho;Soontae Kwon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.118-120
    • /
    • 2000
  • Currently, x-ray is mostly used for the diagnosis of dental cavity and osteoporosis. The osteoporosis is broadly defined as a decrease in the amount of bone mass per unit volume of the bone. Clinically the manifestation of low bone mass presents a clinical problem to the general population as an increase in fracture risk and especially in aging population[1]. Although the amount of the irradiated x-ray to the human body for the clinical diagnosis is relatively small, the exposition of the x-ray to the human body should be minimized as much as possible, since the x-ray is an ionizing radiation. To investigate other possible systems replacing X-ray, ultrasonic imaging and MRI(Magneto-Resonance-Imaging) systems were studied. Unfortunately, an effective and safe diagnosis tool for detecting the dental cavity and the osteoporosis is currently lacking. (omitted)

  • PDF

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

Exposure Time and X-Ray Absorber thickness in the LIGA Process (LIGA 공정에서의 노광시간과 X선마스크 흡광체의 두께)

  • 길계환;이승섭;염영일
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.2
    • /
    • pp.102-110
    • /
    • 1999
  • The LIGA X-ray exposure step was modelled into three inequalities, by assuming that the X-ray energy attenuated within a resist is deposited only in the localized range of the resist. From these inequalities, equations for the minimum and maximum exposure times required for a good quality microstructure were obtained. Also, an equation for the thickness of an X-ray mask absorber was obtained from the exposure requirement of threshold dose deposition. The calculation method of the synchrotron radiation power from a synchrotron radiation source was introduced and applied to an X-ray exposure step. A power from a synchrotron radiation source was introduced and applied to an X-ray exposure step/ A power function of photon energy, approximating the attenuation length of the representative LIGA resist, PMMA, and the mean photon energy of the XZ-rays incident upon an X-ray mask absorber were applied to the above mentioned equations. Consequently, the tendencies of the minimum and maximum exposure and with respect to mean photon energy and thick ness of PMMA was obtained. Additionally, the tendencies of the necessary thickness of PMMA and photon energy of the X-ray mask absorber with respect to thickness of PMMA and photon energy of the X-rays incident upon an X-ray mask absorber were examined. The minimum exposure time increases monotonically with increasing mean photon energy for the same total power density and is not a function of the thickness of resist. The minimum exposure time increases with increasing mean photon energy for the same total power density in the case of the general LIGA process, where the thickness of PMMA is thinner than the attenuation length of PMMA. Additionally, the minimum exposure time increases monotonically with increasing thickness of PMMA. The maximally exposable thickness of resist is proportional to the attenuation length of the resist at the mean photon energy with its proportional constant of ln $(Dd_m/D_{dv})$. The necessary thickness of a gold X-ray mask absorber due to absorption edges of gold, increases smoothly with increasing PMMA thickness ratio, and is independent of the total power density itself. The simplicity of the derived equations has made clearly understandable the X-ray exposure phenomenon and the correlation among the exposure times, the attenuation coefficient and the thickness of an X-ray mask absorber, the attenuation coefficient and the thickness of the resist, and the synchrotron radiation power density.

  • PDF

A Study on the Architectural Planning of the X-ray Unit in General Hospital (종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구)

  • Youn, Woo-Young;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

Dental Waste Management Practices at Dental Offices in Gyeongsangnam-do (경남지역 치과의원 의료폐기물 관리실태)

  • Kim, Hae-Jin;SaKong, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.332-339
    • /
    • 2012
  • Objectives: The purpose of this study was to prevent health problems and environmental contamination resulting from inappropriate management of dental wastes and to provide reference data for revision and supplementation of dental clinic waste management guidelines. Methods: From 640 total of dental clinics registered in 16 cities and counties in Gyeongsangnam-do, 100 (60 in Changwon (Masan, Changwon), 29 in Gimhae, and 11 in Jinju) were included in this study. From July 2010 to September 2010, investigators visited the 100 dental clinics and conducted survey interviews using a structured survey questionnaire regarding disposal methods for liquid wastes (suction pump, spittoon container waste, used liquid disinfectants, and X-ray developer), and disposal methods for solid waste (suction pump, spittoon container waste, and general medical waste). Results: All the 100 dental clinics were found to treat liquid waste from suction pumps and spittoon containers in the same manner as general waste water. Nineteen percent of the clinics treated solid waste that was not filtered through the filter of a suction pump as general waste. Fifty or more percent of the clinics treated solid waste in spittoon containers as general waste. Seventy percent of the clinics used disinfectant solution, although most of them treated used disinfectants in the same manner as general waste water. Some clinics treated used X-ray developer and X-ray fixer in the same manner as general waste water. In most of the clinics, used drapes were washed within the clinic. Conclusions: It was found that waste water and dental wastes at some dental clinics were treated in inappropriately. Thus, in conclusion, the development of guidelines regarding proper management of liquid and solid dental waste at dental clinics is required, and hygiene and environmental training for workers at dental clinics is necessary.

Human Skeletal X-ray Projection Images Applied Fashion Design (인체 골격의 X-ray 투사 이미지를 활용한 패션디자인)

  • Park, Jungin;Lee, Younhee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.3
    • /
    • pp.13-27
    • /
    • 2015
  • The purpose of this study is to understand the general process from textile design till fashion design and to understand the relation between the body structure by using the x-ray technique. The research method was to see background of the anatomic feature and human skeletal X-ray projection through historical aspect of publications, the Internet, and paper. In terms of production, in order to present a design that takes into account the unique silhouette of the human body without distorting the shape of the human skeleton, X-ray images that were reconstituted using a computer graphic tool (Photoshop CS) were reproduced into the fabric as intense images through the digital Textile Printing technique that is capable of expressing fine and delicate details, and applied into the design. An original design was developed that emphasized the impression of the human body being projected and the shape of the human skeleton realistically expressed in terms of silhouette and detail. The results are as follows: First, Body has a anatomic formative characteristic and its formativeness becomes as a great motive for the artistic expression and thereby it becomes more unique and available for new design expression. Second, Using the 'body frame' as the motive of the research, there's mainly tried to make an unique expression. Third, according to reconstructing human skeletal X-ray projection by using Adobe Photoshop CS2, it can be expressed strong and unique design. Forth, DTP which is being used as an essential technique, expresses the body frame realistically and being used the special type of functional product and silk. Likewise by discovering the diverse formativeness of our body frame and reflecting the sense of humanity into the pieces there's been able to make and develop an unique fashion design. I sincerely hope there is a hug progress in this research in this area.

  • PDF