• 제목/요약/키워드: General X-ray

검색결과 551건 처리시간 0.036초

진단용(診斷用) X선장치(線裝置)의 관전압(管電壓) 백분율(百分率) 평균오차(平均誤差)에 관한 조사(調査) 연구(硏究) (A Study on PAE of Tube Voltage of Diagnostic X-ray Units -At the area of Sungnam, Inchon, Seoul-)

  • 임한영;오현주;김영일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.45-50
    • /
    • 1993
  • In this paper, the PAE of tube voltage of 93 diagnostic X-ray units those are using at the 19 general hospitals and 9 local clinics in the area of Sungnam, Inchun, and Seoul have been surveyed. The results are summarized as following. 1. PAE of tube Voltage 70, 100KV at the 56 (60%) X-ray units were ${\pm}7%$ below, at the 8 units (9%), were ${\pm}7%$ above, and those 29 X-ray units (31%) were ${\pm}7%$ below or above with the 70, 100KV tube Voltage in a unit. 2. PAE ${\pm}7%$ below were 68 X-ray units, at the low tube voltage (70KV), and 76 X-ray units at the high tube Voltage (100KV). 3. For six year-use abofe, used X-ray units were PAE ${\pm}7%$ above, and so, the longer used years the more X-ray units became declined in those performance. 4. PAE of tube Voltage were better efficiency at the large capacity 30 X-ray units than small capacity 10. 5. PAE ${\pm}7%$ abovein were only 8 units among 84 diagnostic X-ray units in the general hospitals.

  • PDF

CFRP CNT 패널을 적용한 동물용 X-ray 디텍터 디자인에 관한 연구 (A study on design for animal X-ray detector using CFRP CNT panel)

  • 이석현;김현성;강승민
    • 한국결정성장학회지
    • /
    • 제30권6호
    • /
    • pp.264-270
    • /
    • 2020
  • 사용자 중심의 서비스디자인 방법론을 통한 디자인개발을 진행하고 시제품 제작 시 소재 선정 기준에 대해 조사분석하여 선정된 소재인 CFRP(Carbon Fiber Reinforced Plastics) CNT(Carbon Nano Tube)를 동물용 X-ray 디텍터 패널부분에 적용하여 제품디자인 및 시제품 개발을 진행하고 CFRP CNT 패널을 적용하여 완성된 시제품을 Drop 테스트, 전면 외압 강도 시험, 방진/방수 성능 시험을 진행하여 야외환경에서 사용하는 휴대가능한 동물용 X-ray 디텍터로 활용이 가능한 제품임을 확인하였다.

시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석 (Error Analysis of General X-ray Examination by Using Simulation Training)

  • 성열훈
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.919-927
    • /
    • 2018
  • 본 연구에서는 일반 X선 검사를 대상으로 시뮬레이션 교육 모델을 제시하고 실습 시 발생하는 오류를 분석하고자 하였다. 2012년부터 2018년까지 총 183명 (남자 77명, 여자 106명)의 학생이 참가하였다. 시뮬레이션 X선 시스템은 컴퓨터방사선영상(computed radiography, CR) 시스템을 이용하였다. 환자 보호, X선 검사의 정확성, 영상의 안정성 등의 검사 프로세스에 발생하는 오류 빈도수를 분석하였다. 그 결과 환자 자세 설정 오류, X선 중심선의 정확성 오류, 영상검출판의 크기 및 위치 설정 오류, 그리드 사용의 오류, 마킹의 오류, X선 조사조건 설정 오류, 조사야 설정의 오류, X선 입사각도의 오류, X선 조사거리의 오류 순으로 분석되었다. 이러한 오류를 중심으로 개선된 방사선사 실습 교육이 필요할 것이며 그로 인하여 정밀한 검사와 고품질의 의료서비스를 제공하여 국민들의 보건의료에 조금이나마 기여할 수 있기를 기대한다.

Investigation About Quality Control of General X-ray System

  • Kang, Byung-Sam;Son, Jin-Hyun;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.157-164
    • /
    • 2011
  • This test is for checking investigation about quality control of general X-ray system in clinic and hospital. We compared general X-ray system of clinic and hospital which are selected freely in the metropolitan area using PMX-III and carried out quality control. Carried out Kilovoltage test, mR/mAs output test, Light filed/Beam alignment test, Half value layer test. Most of test result are appeared that failure rates of clinic is higher than hospital one. Therefore, we should lower failure rates through regular quality control and make environment which can get high quality image.

  • PDF

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF

Introduction to Properties of Galactic-X-ray Sources

  • Choi, Chul-Sung;Min, Kyoung-W.;Kim, Tu-Hwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제5권2호
    • /
    • pp.143-158
    • /
    • 1988
  • Since the successful observation by Uhuru, the first astronomical satellite, X-ray astronomy has become one of the rapidly developing fields in astronomy. The scientific results provide us the unique opportunity to understand the high energy nature of X-ray sources. We now know that our galaxy contains many different types of X-ray sources such as the compact X-ray sources, galactic bulge sources in addition to the Sun, the brightest X-ray sources in the sky. In this study we review the general properties of galactic X-ray sources, the characteristics of periodic compact X-ray sources, and bursters as well as the models.

  • PDF

Chandra Archival Survey of Galaxy Clusters: Surface Photometry of Diffuse X-ray Emission

  • 김은혁;김민선
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.77.2-77.2
    • /
    • 2012
  • We have studied the physical properties of X-ray point sources in galaxy clusters for years based on the archival observations using the most sophisticated space X-ray observatory, Chandra X-ray Observatory. Because the ultimate goal of the study is comparing the physical properties of X-ray point sources found in galaxy clusters to those in X-ray blank fields; blank fields are the regions in the sky where any noticeable cosmic diffuse X-ray emission is not observed, an important key issue regarding this study is picking out the point sources related with galaxy clusters. However we do not have red-shift information of all the X-ray point sources. Therefore as a first order approximation we will consider the point sources with smaller projected cluster-centric distance than the adopted size of galaxy clusters. As a first step of this study we perform X-ray surface photometry of ~600 galaxy clusters based on ~800 Chandra ACIS observations. We carefully investigate the radial structures of diffuse X-ray emission in 3 different energy bands. Based on the highly accurate surface photometry we determine the characteristic size of diffuse X-ray emission (i.e., the boundary of X-ray emission). We also investigate the cosmological evolution of this characteristic size of galaxy clusters. General discussion regarding the two dimensional morphology of galaxy clusters will be presented.

  • PDF

Sparse 표현을 이용한 X선 흡수 영상 개선 (X-ray Absorptiometry Image Enhancement using Sparse Representation)

  • 김형일;엄원용;노용만
    • 한국멀티미디어학회논문지
    • /
    • 제15권10호
    • /
    • pp.1205-1211
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위해 X 선 영상에서 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도는 X 선 영상에서 뼈가 분리되고, 분리된 영역에서의 픽셀에 의해 BMD가 측정되는데, 개선된 영상에서의 정밀한 뼈 추출이 주요한 요소이므로 X 선 영상의 개선은 골다공증의 조기 진단을 위해 필수적이다. 본 논문에서는 sparse 표현을 도입하여 다중(multiple) 잡음을 갖는 X 선 영상을 개선시키는 방법을 제안한다. 실험을 통해 제안한 방법의 결과가 기존의 방법인 웨이블릿 BayesShrink 잡음 제거 방법 및 일반적 sparse 표현 모델의 잡음 제거 방법의 결과에 비해 개선됨을 CNR(Contrast to Noise Ratio) 및 cut-view를 통해 확인하였다.

자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가 (Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device)

  • 권오영;이창훈;용금주;진선희;정다빈;허영철
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.1049-1056
    • /
    • 2021
  • 본 연구의 목적은 일반촬영용 호흡 동기화 장치를 개발하여 호흡 협조가 어려운 환자의 가슴 검사를 할 때 들숨의 재현성을 높이는 것이다. 공기압 센서를 이용하여 호흡 동기화 장치를 자체 제작(X-RSD)하였고, 심폐소생술용 마네킹에 벤틸레이터를 연결하여 공기를 주입하였다. 이때 주입한 공기의 양은 SkillReporting 장치를 이용하여 정량화하였다. 마네킹의 가슴에 X-RSD를 위치한 후 공기의 양을 200-700 cc까지 100 cc 씩 총 6 단계를 나눠서 검사하였다. 오차 평가는 총 80회씩 반복 측정하여 X-RSD의 민감도를 측정하였고 민감도는 100%로 매우 정교한 결과 값을 얻을 수 있었다. 이후 가슴 측면검사를 X-RSD를 보면서 검사한 영상과, 암맹 검사한 영상을 비교평가 하였고, X-RSD의 폐 용적이 암맹 검사보다 용적도 크게 측정되고, 편차도 적게 측정되었다. 종합적으로 X-RSD를 이용하면 협조가 어려운 환자의 가슴검사에 도움을 줄 수 있으며, 일반촬영의 재촬영률을 줄여 전체적인 피폭선량 감소에 기여가 가능할 것이라 사료된다.