• 제목/요약/키워드: Gear Oil

검색결과 138건 처리시간 0.024초

세관내 이산화탄소의 증발 열전달 및 압력강화 (Evaporation Heat Transfer and Pressure Drop of $CO_2$ in a Small diameter Tube)

  • 장승일;최선묵;김대희;박기원;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.189-194
    • /
    • 2005
  • The evaporation heat transfer and pressure drop of $CO_2$ in a small diameter tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 $kg/m^2s$, saturation temperature of $0^{\circ}C$ to $20^{\circ}C$, and heat flux of 10 to 20 $kW/m^2$ . The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation pressure drop of C02 are highly dependent on the mass flux. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient and pressure drop of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient and friction pressure drop of $CO_2$ in a horizontal tube.

  • PDF

내경 4.57과 7.75 mm인 수평관내 이산화탄소의 증발 압력강하 (Evaporation Pressure Drop of Carbon Dioxide in Horizontal Tubes with Inner Diameter of 4.57 mm and 7.75 mm)

  • 손창효
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.30-37
    • /
    • 2008
  • The evaporation pressure drop of $CO_2$ (R-744) in horizontal tubes was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 and 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The pressure drop measured during the evaporation process of $CO_2$ increases with increased mass flux, and decreases as the saturation temperature increased. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

수평원관내 $CO_2$의 증발열전달 (Evaporation Heat Transfer of Carbon Dioxide in a horizontal Round Tube)

  • 경남수;장승일;최선묵;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.262-267
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ in a horizontal round tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 7.75 mm, and length of 5 m. The experiments were conducted at mass flux of 200 to 500 $kg/m^2s$, saturation temperature of $-5^{\circ}C$ to $5^{\circ}C$, and heat flux of 10 to 40 $kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with teat results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Lee Dong-Geon;Son Chang-Hyo;Oh Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.297-305
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter. a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$. saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greatly effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality. heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In making a comparison between test results and existing correlations. the present experimental data are the best fit for the correlation of Jung et al. But it was failed to predict the evaporation heat transfer coefficient of $CO_2$ using by the existing correlation. Therefore. it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Son Chang-Hyo;Kim Dae-Hui;Choi Sun-Muk;Kim Young-Ryul;Oh Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.167-174
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500kg/m^2s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greater effect on nucleate boiling than convective boiling. The evaporation heat transfer coefficient of $CO_2$ is highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Jung et al. But the existing correlations failed to predict the evaporation heat transfer coefficient of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

채낚기 어선용 수랭식 LED 집어시스템의 설계 및 성능평가 (Design and performance estimation of fish-luring system using the water cooling typed LED lamp)

  • 배봉성;안희춘;권기진;박성욱;박창두;이경훈
    • 수산해양기술연구
    • /
    • 제47권2호
    • /
    • pp.79-87
    • /
    • 2011
  • A fishing lamp is fishing gear to gather fish in the night. But the cost of oil which is used to a light fishing lamp, goes significantly up to almost one hundred million won for 50 tonnage vessels and forty million won in case of vessels less than 10 tonnages. This cost has almost taken 30.40% of total fishing costs. As oil price increases, the business condition of the fishery gets worse and worse. Therefore, it is very urgent to develop an economical fishing lamp, to solve the problem of fishery's business difficulty. This research aims at developing a fishing lamp for squid jigging fishery and hairtail angling fishery using the LED, which has excellent efficiency and durability. One fishing lamp has about 160Watt capacity and five fishing lamps are installed one aluminium panel in which sea water flows to emit generated heat from LED to outside. Developed fishing lamp lights to an effective direction of jigging and angling operation. This fishing lamp can be controlled to light the direction of fish shoal because the aluminium panel can be controlled to up and down direction. The wave length of fishing lamp has white and blue color. White color light is to gather fish shoal of horizontal direction and blue color light is to gather fish shoal of vertical direction. After development of this fishing lamp, 60.110 units are established on the boat, and operated fishing. Consequently, in the case of squid jigging, spent energy was reduced to 39%, in the case of hairtail angling, 68% of spent energy was reduced. And the catch was more than another boat.

연무자리돔, Chromis fumea (Pisces: Pomacentridae)의 산란보호, 난발생 및 자어의 형태발달 (Male Parental Care, Egg and Larval Development of the Smoky Damselfish, Chromis fumea (Pisces: Pomacentridae))

  • 김진구;김용억;박진우
    • 한국어류학회지
    • /
    • 제13권3호
    • /
    • pp.166-172
    • /
    • 2001
  • 1995년 8월 제주도 근해에서 스쿠바 다이빙하여 연무자리돔의 산란보호행동을 관찰하였으며, 채집된 연무자리돔의 난은 부경대학교로 운반하여 부화, 사육하였다. 연무자리돔의 난은 평탄하고 단단한 기질의 산란소에 한층으로 부착되어 있었고, 수컷은 산란소 주위에서 접근해오는 다른 어종을 공격하는 산란보호행동을 나타내었다. 수정난은 무색투명하고, 타원형을 띠며, 부착사를 가진 침성부착난으로 난경은 장경이 0.73~0.88 mm, 단경이 0.50~0.56 mm이었다. 시간의 경과에 따른 난경의 변화는 T-test 결과 장경은 유의한 차이를 나타내었으나 (p<0.01) 단경은 유의한 차이가 없었다 (p>0.05). 수정난은 $23.0{\sim}25.5^{\circ}C$ 수온 범위에서 사육되었으며, 부화까지는 4~5일이 소요되었다. 부화자어는 척색장 1.10~1.61 mm로 21개의 근절을 가지고 있고 입은 닫힌 상태이나 항문은 열려 있으며, 항문전장은 척색장의 45.8%에 달하였고, 흑색소포는 두정부, 눈, 복강의 등쪽 및 꼬리의 배쪽 가장자리에 분포하였다. 부화자어의 난황과 유구는 부화 후 3~4일만에 완전히 흡수되어, 이 시기에 후기자어로 이행하였다. 부화 후 3일째 자어는 척색장 1.9~2.4 mm로 25개의 근절을 가지며, 빠르게 성장하였고, 부화 후 9일째 자어는 척색장 2.9 mm로 복부 등쪽에 처음으로 부레가 출현하였으며, 흑색소포는 형태적으로 커지면서 수적으로는 감소하였다.

  • PDF

채낚기 어선용 공랭식 LED 집어시스템의 설계 및 성능평가 (Design and performance evaluation of fish-luring system using the air-cooled LED lamp for jigging and angling boat)

  • 배봉성;박병재;정의철;양용수;박해훈;전영열;장대수
    • 수산해양기술연구
    • /
    • 제45권2호
    • /
    • pp.85-95
    • /
    • 2009
  • The fishing lamp is a fishing gear that gathers fish at night. But the cost of oil, which is used to light fishing lamp, has been risen significantly up to 30-40% of total fishing costs. Therefore it is very urgent to develop an energy economical fishing lamp in order to solve the business difficulties of fisheries. Under this background, this research aims at developing a fishing lamp for squid jigging and hairtail angling fishery using the LED, which has excellent energy efficiency and durability. The LED fishing lamp developed can be controlled to fix a fit direction of fish shoal deep because a fishing lamp can be adjustable up and down directions. One unit of fishing lamp has about an 80Watt capacity and the frame of fishing lamp is made of aluminium to emit generated heat of LED to outside. The LED lamp developed was highly durable, only 5.7% of emitting efficiency decreased for 18 months. The illuminance of a unit LED lamp was 2,070lux at 1m and 21lux at 10 m distance, and the intensity of LED lamp system emitted 2,580lux and 400lux at the respective distances. After development of this fishing lamp, 100 units are installed on operating fishing vessels. Experimental results show that energy consumption of squid jigging and hairtail angling was reduced by 40% and 87%, respectively. In conclusion, our methods showed elevated fishing power, compared with traditional fishing method: 37.7% for squid jigging and 24.5% for hairtail angling.