• Title/Summary/Keyword: GeO

Search Result 404, Processing Time 0.026 seconds

Pharmacopuncture of Bauhinia variegata Nanoemulsion Formulation against Diabetic Peripheral Neuropathic Pain

  • Gupta, Pushpraj S;Singh, Sunil K;Tripathi, Abhishek K
    • Journal of Pharmacopuncture
    • /
    • v.23 no.1
    • /
    • pp.30-36
    • /
    • 2020
  • Objectives: The objective of the study was to prepare Bauhinia variegata loaded nanoemulsion(formulation and determine the efficacy of herbal drug formulation against diabetic peripheral neuropathic pain through acupuncture technique. Methods: Nine different ba tches of nanoemulsion (NE1 NE9) of BVN was prepared by varying the Smix ratio and the concentration of oil. BVN was characterized to determine particle size, shape, zeta potential, polydispersity index, optical transmittance, drug release profile and stora ge stability. The optimized formulation was subjected to plantar test, behavioral tests of neuropathic pain and Von Frey filament stimulation test. Diabetes was induced by intraperitoneal injection of freshly prepared solution of Streptozotocin (60 mg/kg) to the experimental rats. Animals were made diabetic divided into four groups, Group I was untreated normal control group, Group II was diabetic control group, Group III was Bauhinia variegata extract ( treated group (100 mg/kg/day, p.o) and Group IV was BVN treated groups (100 mg/kg/day, p.o) acute and chronically. Results: The prepared B. variegata loaded nanoemulsion was nanosized (124 nm), spherical, uniform and stable over the period of 180 days with no change in physiochemical properties. The bl ood glucose and body weight of animals was normalizing after four weeks of treatment that was significant with BVN in comparison to diabetic control group. The chronic administration of BVN significantly (P<0.001) decreased hind paw withdrawal latency an d attenuated mechanical allodynia as compared with diabetic rats. Conclusion: Thus, BVN may be an effective drug formulation against diabetic peripheral neuropathic pain.

ALTERATION OF SUPEROXIDE DISMUTASE-AND CATALASE-ACTIVITY IN HUMAN GINGIVAL TISSUES BY THE PERIODONTAL DISEASE SEVERITY (치주질환 심도에 따른 치은조직내의 Superoxide Dismutase와 Catalase의 활성변화에 관한 연구)

  • Kim, Byung-Ok;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.39-49
    • /
    • 1994
  • It has been believed that antioxidant enzymes such as CuZn- and Mn-superoxide dismutase and catalase protect the tissue from damage resulting from the oxygen derived free radicals($O_2\;^-$, $H_2O_2$ and OH ). The purpose of this study was to investigate the relationship between activity of antioxidant enzymes including CuZn- and Mn- superoxide dismutase and catalase and inflammatory periodontal disease and periodontal parameters. For this study, the patients were classified into normal, gingivitis, adult periodontitis and rapidly progressive periodontitis, and then their papillary bleeding index(PBI) and probing depth were checked. Gingival tissues were surgically obtained from the patients during periodontal surgery, extraction, and clinical crown lengthening procedure. The activity of CuZn- and Mn- superoxide dismutase and catalase in the gingival tissues was measured by using UV-spectrophotometer by the same methods as Crapo et al. And Aebi did, respectively. The results were as follows : 1. CuZn- and Mn- and total-superoxide dismutase activity were significantly low in rapidly progressive periodontitis group in comparison to normal group (P<0.05). 2. In comparison of the antioxidant enzyme activity according to papillary bleeding index group(PBI), Mn-superoxide dismutase activity only was significantly lower in PBI 2, 3, and 4 groups than PBI 0 group(P<0.05). 3. Superoxide dismutase activity failed to show any significant difference according to probing depth. But significant]y high catalase activity was shown in deep pocket group (${\ge}7mm$)(P<0.05). In conclusion, these results suggest that the activity of Mn-superoxide dismutase among the antioxidant enzymes may reflect the inflammatory status of gingival tissue and that the decreased activity of superoxide dismutase may be one of responsibe factors for progression of rapidly progressive periodontitis.

  • PDF

Recent Status of Commercial PET Cyclotron and KOTRON-13 (KOTRON-13과 상용 PET 사이클로트론의 최근 기술 동향)

  • Chai, Jong-Seo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper is described on the development of KOTRON-13 and recent status of PET cyclotron by commercial cyclotron companies. KIRAMS has developed medical cyclotron which is KIRAMS-13. Samyoung Unitech produces KOTRON-13 with transfered technology by KIRAMS. As a part of Regional Cyclotron Installation Protect, KOTRON-13 cyclotrons and $[18F]FDG$ production modules are being installed at regional cyclotron centers in Korea. The medical concern with radiation technology has been growing for the last several years. Early cancer diagnosis through the cyclotron and PET-CT have been brought to public attention by commercial cyclotron models in the world. The new commercial cyclotron models are introduced compact low energy cyclotrons developed by CTI, GE, Sumitomo in recent. It produces different short-lived radioisotopes, such as $[^{18}F],\;[^{11}C],\;[^{13}N]\;and\;[^{15}O]$. For the better reliability acceleration particle is proton only. The characteristics of new model cyclotrons are changed to lower energy corresponding to less 13 MeV. New models have self-shielding and low power consumption. Design criteria for the different types of commercial cyclotrons are described with reference to hospital demands.

Characterization analysis of Rongchang pig population based on the Zhongxin-1 Porcine Breeding Array PLUS

  • Dong Leng;Liangpeng Ge;Jing Sun
    • Animal Bioscience
    • /
    • v.36 no.10
    • /
    • pp.1508-1516
    • /
    • 2023
  • Objective: To carry out a comprehensive production planning of the existing Rongchang pig population from both environmental and genetic aspects, and to establish a closed population with stable genetic diversity and strict pathogen control, it is necessary to fully understand the genetic background of the population. Methods: We genotyped 54 specific pathogen free (SPF) Rongchang pigs using the Zhongxin-1 Porcine Breeding Array PLUS, calculated their genetic diversity parameters and constructed their families. In addition, we also counted the runs of homozygosity (ROH) of each individual and calculated the value of inbreeding coefficient based on ROH for each individual. Results: Firstly, the results of genetic diversity analysis showed that the effective population size (Ne) of this population was 3.2, proportion of polymorphic markers (PN) was 0.515, desired heterozygosity (He) and observed heterozygosity (Ho) were 0.315 and 0.335. Ho was higher than He, indicating that the heterozygosity of all the selected loci was high. Secondly, combining the results of genomic relatedness analysis and cluster analysis, it was found that the existing Rongchang pig population could be divided into four families. Finally, we also counted the ROH of each individual and calculated the inbreeding coefficient value accordingly, whose mean value was 0.09. Conclusion: Due to the limitation of population size and other factors, the genetic diversity of this Rongchang pig population is low. The results of this study can provide basic data to support the development of Rongchang pig breeding program, the establishment of SPF Rongchang pig closed herd and its experimental utilization.

Comparison of Characteristics of Gamma-Ray Imager Based on Coded Aperture by Varying the Thickness of the BGO Scintillator

  • Seoryeong Park;Mark D. Hammig;Manhee Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.214-225
    • /
    • 2022
  • Background: The conventional cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)) scintillator-based gamma-ray imager has a bulky detector, which can lead to incorrect positioning of the gammaray source if the shielding against background radiation is not appropriately designed. In addition, portability is important in complex environments such as inside nuclear power plants, yet existing gamma-ray imager based on a tungsten mask tends to be weighty and therefore difficult to handle. Motivated by the need to develop a system that is not sensitive to background radiation and is portable, we changed the material of the scintillator and the coded aperture. Materials and Methods: The existing GAGG(Ce) was replaced with Bi4Ge3O12 (BGO), a scintillator with high gamma-ray detection efficiency but low energy resolution, and replaced the tungsten (W) used in the existing coded aperture with lead (Pb). Each BGO scintillator is pixelated with 144 elements (12 × 12), and each pixel has an area of 4 mm × 4 mm and the scintillator thickness ranges from 5 to 20 mm (5, 10, and 20 mm). A coded aperture consisting of Pb with a thickness of 20 mm was applied to the BGO scintillators of all thicknesses. Results and Discussion: Spectroscopic characterization, imaging performance, and image quality evaluation revealed the 10 mm-thick BGO scintillators enabled the portable gamma-ray imager to deliver optimal performance. Although its performance is slightly inferior to that of existing GAGG(Ce)-based gamma-ray imager, the results confirmed that the manufacturing cost and the system's overall weight can be reduced. Conclusion: Despite the spectral characteristics, imaging system performance, and image quality is slightly lower than that of GAGG(Ce), the results show that BGO scintillators are preferable for gamma-ray imaging systems in terms of cost and ease of deployment, and the proposed design is well worth applying to systems intended for use in areas that do not require high precision.

The Correlation between HRCT Emphysema Score and Exercise Pulmonary Testing Parameters (HRCT Emphysema Scoring과 운동부하 폐기능검사 지표들 간의 상관관계)

  • Choi, Eun-Kyoung;Choi, Young-Hee;Kim, Doh-Hyung;Kim, Yong-Ho;Yoon, Se-Young;Park, Jae-Seuk;Kim, Keun-Youl;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.415-425
    • /
    • 2001
  • Background : The correlation between the high resolution computed tomography(HRCT) emphysema score and the physiologic parameters including resting and exercise pulmonary function test was investigated in 14 patients($60.6{\pm}10.3$ years) with pulmonary emphysema. Methods : The patients underwent a HRCT, a resting pulmonary function test, and incremental exercise testing(cycle ergometer, 10 W/min). Computed tomography scans were obtained on a GE highlight at 10 mm intervals using 10 mm collimation, from the apex to the base after a full inspiration. The emphysema scores were determined by a CT program 'Density mask' outlining the areas with attenuation values less than -900 HU, indicating the emphysema areas, and providing an overall percentage of lung involvement by emphysema. Results : Among the resting PFT parameters, only the diffusing capacity(r=-0.75) and $PaO_2$ (r=-0.66) correlated with the emphysema score(p<0.05). Among the exercise test parameters, the emphysema score correlated significantly with the maximum power(r=-0.74), maximum oxygen consumption(r=-0.68), anaerobic threshold(V-slope method: r=-0.69), maximal $O_2$-pulse(r=-0.73), and the physiologic dead space ratio at the maximum workload(r=-0.80)(p<0.01). Conclusion: We could find that exercise testing parameters showed a much better correlation with the HRCT emphysema score, which is known to have a good correlation with the pathologic severity than the resting PIT parameters. Therefore it is suggested that exercise testing is superior to resting PIT for estimating in the estimation of the physiologic disturbance in emphysema patients.

  • PDF

Evaluation of Amino Acid and Energy Utilization in Feedstuff for Swine and Poultry Diets

  • Kong, C.;Adeola, O.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.7
    • /
    • pp.917-925
    • /
    • 2014
  • An accurate feed formulation is essential for optimizing feed efficiency and minimizing feed cost for swine and poultry production. Because energy and amino acid (AA) account for the major cost of swine and poultry diets, a precise determination of the availability of energy and AA in feedstuffs is essential for accurate diet formulations. Therefore, the methodology for determining the availability of energy and AA should be carefully selected. The total collection and index methods are 2 major procedures for estimating the availability of energy and AA in feedstuffs for swine and poultry diets. The total collection method is based on the laborious production of quantitative records of feed intake and output, whereas the index method can avoid the laborious work, but greatly relies on accurate chemical analysis of index compound. The direct method, in which the test feedstuff in a diet is the sole source of the component of interest, is widely used to determine the digestibility of nutritional components in feedstuffs. In some cases, however, it may be necessary to formulate a basal diet and a test diet in which a portion of the basal diet is replaced by the feed ingredient to be tested because of poor palatability and low level of the interested component in the test ingredients. For the digestibility of AA, due to the confounding effect on AA composition of protein in feces by microorganisms in the hind gut, ileal digestibility rather than fecal digestibility has been preferred as the reliable method for estimating AA digestibility. Depending on the contribution of ileal endogenous AA losses in the ileal digestibility calculation, ileal digestibility estimates can be expressed as apparent, standardized, and true ileal digestibility, and are usually determined using the ileal cannulation method for pigs and the slaughter method for poultry. Among these digestibility estimates, the standardized ileal AA digestibility that corrects apparent ileal digestibility for basal endogenous AA losses, provides appropriate information for the formulation of swine and poultry diets. The total quantity of energy in feedstuffs can be partitioned into different components including gross energy (GE), digestible energy (DE), metabolizable energy (ME), and net energy based on the consideration of sequential energy losses during digestion and metabolism from GE in feeds. For swine, the total collection method is suggested for determining DE and ME in feedstuffs whereas for poultry the classical ME assay and the precision-fed method are applicable. Further investigation for the utilization of ME may be conducted by measuring either heat production or energy retention using indirect calorimetry or comparative slaughter method, respectively. This review provides information on the methodology used to determine accurate estimates of AA and energy availability for formulating swine and poultry diets.

The Study of the Tunnel Recombination Junction Properties in Multi-Junction Thin Film Silicon Solar Cells (다중 적층형 박막 실리콘 태양 전지의 터널 접합 특성 연구)

  • Hwang, Sun-Tae;Shim, Jenny H.;Chung, Jin-Won;Ahn, Seh-Won;Lee, Heon-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.62.2-62.2
    • /
    • 2010
  • 박막 실리콘 태양 전지는 저가격화 및 대량생산, 대면적화에 유리하다는 장점을 가지고 있다. 단점으로 지적되는 낮은 효율을 극복하기 위해 광흡수층의 밴드갭이 서로 다른 두 개 이상의 박막을 적층하여, 넓은 파장 대역의 빛을 효과적으로 흡수함으로써 광변환 효율을 올리기 위한 많은 연구가 이루어지고 있다. 서로 다른 밴드갭의 광흡수층을 가진 p-i-n 구조를 다중 적층하여 고효율의 태양 전지를 제작하기 위해서는 n-도핑층과, p-도핑층 간에 전자와 정공이 빠르게 재결합할 수 있는 터널 접합(Tunnel Recombination Junction)의 형성이 필수적이며, 이때 광손실이 최소화되도록 해야한다. 만약 터널 접합이 적절하게 형성되지 않으면 결합되지 않은 전자와 정공이 도핑층 사이에 쌓이게 되고, 도핑층 사이의 저항 증가로 태양 전지의 광변환 효율은 크게 하락한다. 이번 연구에서는 터널 접합이 잘 이루어지게 하기 위한 n-도핑층 및 p-도핑층 박막의 특성과, 터널 접합의 특성에 따른 적층형 태양 전지의 광효율 변화를 확인하였다. 광흡수층 및 도핑층은 TCO($SnO_2:F$, Asahi) 유리 기판 위에 PECVD를 사용하여 p-i-n 구조로 RF Power 조건에서 증착되었고, ${\mu}c$-Si 광흡수층의 경우에는 VHF Power 조건에서 증착되었다. 광흡수층이 a-Si/${\mu}c$-Si의 구조를 가지는 이중 접합 태양 전지에서 ${\mu}c$-Si n-도핑층/${\mu}c$-Si p-도핑층 사이의 터널 접합 실험 결과 n-도핑층 및 p-도핑층의 결정화도와 도핑 농도를 조절하여 터널 접합의 저항을 최소화했고, 터널 접합 특성이 이중 접합 셀의 광효율 특성과 유사한 경향을 보임을 확인하였다. 광흡수층이 a-Si/a-SiGe/${\mu}c$-Si의 구조를 가지는 삼중 접합 태양 전지 실험의 경우 a-Si과 a-SiGe 광흡수층 사이에 ${\mu}c$-Si n-도핑층/${\mu}c$-Si p-도핑층/a-SiC p-도핑층의 구조를 적용하여 터널 접합을 형성하였으며, ${\mu}c$-Si p-도핑층의 두께 및 박막 특성을 개선하여 광손실이 최소화된 터널 접합을 구현하였고, 삼중 접합 태양 전지에 적용되었다.

  • PDF

Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study (범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구)

  • Bahn, Young Kag;Hwang, Dong Hoon;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Purpose Recently, Cadmium-zinc-telluride (CZT) semiconductor myocardial SPECT (Single Photon Emission Computed Tomography) has been used myocardial scintigraphy. In this study, the performance of Semiconductor SPECT and conventional SPECT systems was compared by a comprehensive analysis of phantom SPECT images. Materials and Methods Methods: We evaluated the DSPECT CZT SEPCT (Spectrum-dynamic) and INFINA conventional (GE). Physical performance was compared on reconstructed SPECT images from a phantom. Results For count sensitivity on cardiac phantom images ($counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$), DSPECT had a sensitivity of conventional SPECT. This classification was similar to that of myocardial counts normalized to injected activities from phantom images (respective mean values, $counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$: 195.83 and 52.83). For central spatial resolution: DSPECT, 9.47mm; conventional SPECT, 16.90mm. For contrast-to-noise ratio on the phantom: DSPECT, 4.2; conventional SPECT, 3.6. Conclusion The performance of CZT cameras is dramatically higher than that of conventional SPECT. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with conventional SPECT, whereas count sensitivity is markedly higher with the DSPECT.

  • PDF

Effect of Various Dietary Protein Levels on Growth and Body Composition of Young Common Carp Reared in Recirculating System

  • Cho, Sung-Hwoan;Jo, Jae-Yoon;Hur, Sung-Bum;Kim, You-Hee;Shin, Chang-Hoon
    • Journal of Aquaculture
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • The effect of various dietary protein levels on growth and body composition of young common carp raised from 56 g to 170 g in recirculating system was investigated for 15 weeks when they were fed to visual satiety three times daily. Five experiemtal diets were formulated to contain 40, 35, 30, 25 and 21% protein levels and 3.56, 3.59. 3.63, 3.66 and 3.69 kcal/g diet GE levels respectively. Mean survival rates of the fish fed the 40, 35, 30 and 25% protein diets were not different but sig-nificantly higher than that of the fish fed the 40, 35, 30 and 25% protein diets were not different but sig-nificantly higher than that of o the fish fed the 21% protein diet(P<0.05) Weight gain (g/tank) of common carp fed the 30% protein diet was the best. However weight gain of the fish fed the 25, 30, 35 and 40% protein diets were not different but significantly better than that of the fish fed the 21% protein diet. Feed efficiency ratio of the 21% protein diet was significantly lower (P<0.05) than for other groups of diets which were not different among them. Protein efficiency ratio for the 21% protein diet was significantly lower (P<0.05) than for other groups of diets which were not different among them(P>0.05) Dietary protein level had no effect on hemoglobin content in the fish(P>0.05) Crude protein contents of whole body of the fish fed the 35 and 40% protein diets were significantly higher than that of the fish fed the 21$$\mid$% or 25% protein diet(P<0.05) Body crude lipid contents of the fish fed the 21 and 25% protein diets were significantly higher than that of the fish fed the 30% or 35% protein diet. Crude ash contents of the fish fed the 35 and 40% protein diets were significantly higher than that of the fish fed the 21% or 25% protein diet(P<0.05) Moisture content of the fish fed the 35% protein diet was significantly higher than that of the fish fed the 21% protein diet(P<0.05) In considering growth performance of common carp and efficiency of diet dietary protein level could be lowered up to 25% without the reduction of young common carp production in recirculating system.

  • PDF