• Title/Summary/Keyword: Gated radiation therapy

Search Result 48, Processing Time 0.017 seconds

Absorbed Dose and Effective Dose for Lung Cancer Image Guided Radiation Therapy(IGRT) using CBCT and 4D-CBCT (폐암 영상유도방사선 치료 시 CBCT와 4D-CBCT를 이용한 흡수선량 및 유효선량에 관한 선량 평가)

  • Kim, Dae yong;Lee, Woo Suk;Koo, Ki Lae;Kim, Joo Seob;Lee, Sang Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose : To evaluate the results of absorbed and effective doses using CBCT and 4D-CBCT settings for lung cancer. Materials and Methods : This experimental study. Measurements were performed using a Anderson rando phantom with OSLD(optically stimulated luminescent dosimeters). It was performed computed tomography(Lightspeed GE, USA) in order to express the major organs of the human body. Measurements were obtained a mean value is repeated three times each. Evaluations of effective dose and absorbed dose were performed the CL-IX-Thorax mode and Truebeam-Thorax mode CBCT. Additionally, compared Truebeam-Thorax mode CBCT with Truebeam-Thorax mode 4D-CBCT(Four-dimensional Cone Beam Computed Tomography) Results : Average absorbed dose in the CBCT of CL-IX was measured in lung 2.505cGy, heart 2.595cGy, liver 2.145cGy, stomach 1.934cGy, skin 2.233cGy, in case of Truebeam, It was measured lung 1.725cGy, heart 2.034cGy, liver 1.616cGy, stomach 1.470cGy, skin 1.445cGy. In case of 4D-CBCT, It was measured lung 3.849cGy, heart 4.578cGy, liver 3.497cGy, stomach 3.179cGy, skin 3.319cGy Average effective dose, considered tissue weighting and radiation weighting, in the CBCT of CL-IX was measured lung 2.164mSv, heart 2.241mSVv, liver 0.136mSv, stomach 1.668mSv, skin 0.009mSv, in case of Turebeam, it was measured lung 1.725mSv, heart 1.757mSv, liver 0.102mSv, stomach 1.270mSv, skin 0.005mSv, In case of 4D-CBCT, It was measured lung 3.326mSv, heart 3.952mSv, liver 0.223mSv, stomach 2.747mSv, skin 0.013mSv Conclusion : As a result, absorbed dose and effective Dose in the CL-IX than Truebeam was higher about 1.3 times and in the 4D-CBCT Truebeam than CBCT of Truebeam was higher about 2.2times However, a large movement of the patient and respiratory gated radiotherapy may be more accurate treatment in 4D-CBCT. Therefore, it will be appropriate to selectively used.

  • PDF

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구)

  • Song Heung-Kwon;Kwon Kyung-Tae;Park Cheol-Su;Yang Oh-Nam;Kim Min-Su;Kim Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. Materials and Methods : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Results : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient #1, motion of GTV was reduced to 2.6 mm in treatment phases ($30{\sim}60%$), while that was 9.4 mm in full phases ($0{\sim}90%$) and for patient #2, it was reduced to 2.3 mm in treatment phases ($30{\sim}70%$), while it was 11.7 mm in full phases ($0{\sim}90%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Target motion analysis of the respiratory gated guided radiotherapy in liver cancer patients using 4D-CT (4D-CT와 호흡동조시스템을 이용한 간암 환자의 방사선치료 표적 움직임 분석)

  • Dong, Kyung-Rae;Park, Byung-Soo;Kim, Sae-Sark;Kweon, Dae-Cheol;Goo, Eun-Hoe;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.63-68
    • /
    • 2010
  • The ultimate goal of radiation treatment is to use enough radiation dosage in order to examine a tumor while protecting normal tissue. Respiratory guided radiotherapy is being clinically implemented to examine a given stabilized area in order to compensate for the problems of patient breathing. This study investigates the effects of breathing movements on 40 patients with liver cancer through the actual radiation therapy plan using 4D-CT and respiratory guided radiotherapy using RPM. Using a commercial RPM respiratory gating system 4D-CT, we acquired 4D CT on multislice helical CT scanners that use different approaches to 4D CT image reconstruction. The results from analyzing forty patients according to age and direction showed no relationship between gender and transition change. The mean left-right, anteroposterior, and craniocaudal total movements were $3.19{\pm}1.29$, $5.44{\pm}2.07$, and $12.54{\pm}4.70$ mm, respectively. Changes were the largest with CC directions and as patients advanced in age, movements were larger. Therefore, as changes occur in treatment areas because of movements caused from breathing, respiratory gating system is put into operation to revise movement and can increase the radiotherapeutics effects in treating liver cancer.

Evaluation 4D-CT Simulation used of Motion Organ and Tumor for Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 4D-CT simulation을 이용한 동적장기와 종양 움직임 평가)

  • Kim, Seung-Chul;Kim, Min-A
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.395-402
    • /
    • 2015
  • when the radiation therapy of chest and abdomen, evaluation of the tumor motion and the data was used to minimize damage to normal tissues by separating the tumor and normal tissue and maximize tumor therapeutic effect. Lung and liver cancer each 20 patients based on the 50% top phase using 4D-CT simulation and Light speed-16 of shooting equipment 30 ~ 70 % gating phase interval and 0 ~90 % movement in the full phase interval was measured. If the full phase 0 ~ 90% with gating phase 30~70% of tumors in the liver and lung is shown the biggest difference compared to the motion and the size of the GTV was the largest difference in the I(inferior), full phase 0~90% degree of tumor motion only when a relatively large, gating phase to 30~70% of the tumor when the movement has been found that the reduced average 7.1mm. In the 4D-CT simulation comparing the motion value when the full phase 0~90 % and gating phase 30~70 % when the motion value, twice in the gating phase 30~70 % more than full phase 0~90 % showed a small movement value. The exposure to normal tissues, based on the results obtained from the 4D-CT simulation can be significantly alleviated, After treatment will reduce pain and disability in patients with radiation is expected to be able to effective treatment.

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Development of Respiratory Signal Analysis Program for Accurate Phase Reassignment in 4D CT Reconstruction (4D CT 영상 재구성 시 정확한 위상 변환을 위한 호흡 신호 분석 프로그램 개발)

  • Park, Hae-Jin;Jung, Won-Gyun;Yoon, Jai-Woong;Song, Ju-Young;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.241-246
    • /
    • 2008
  • Patient's respiration can have an effect on movement of tumor range and peripheral organs. Therefore, the respiratory signal was acquired by relation between external markers and movement of patient's abdomen during radiational therapy in order to minimize the effect of respiration. Based on this technique, many studies of rational therapy to irradiate at particular part of stable respiratory signals have executed and they have been clinically applied. Nevertheless, the phase-based method is preferred to the amplitude-based method for the rational therapy related to respiration. Because stabilization of the respiratory signal are limited. In this study, a in-house respiratory signal analysis program was developed for the phase reassignment and the analysis of the irregular respiratory signals. Various irregular respiratory patterns was obtained from clinical experimental volunteers. After then, the in-house program analyzed the factors affecting to phase assignment which is directly related to irradiated sector. Subsequently, accuracy of phase assignment was improved with removement of irregular signals by self-developed algorithm. This study is considered to be useful for not only image reconstruction and elevation of irradiating accuracy through phase assignment of RPM system but also analysis of respiratory signals. Moreover, development of 4D CT image is planed with phantom researches or clinical experiments based on this program.

  • PDF

Analysis of Respiratory Motional Effect on the Cone-beam CT Image (Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mi-Sun
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2007
  • The cone-beam CT (CBCT) which is acquired using on-board imager (OBI) attached to a linear accelerator is widely used for the image guided radiation therapy. In this study, the effect of respiratory motion on the quality of CBCT image was evaluated. A phantom system was constructed in order to simulate respiratory motion. One part of the system is composed of a moving plate and a motor driving component which can control the motional cycle and motional range. The other part is solid water phantom containing a small cubic phantom ($2{\times}2{\times}2cm^3$) surrounded by air which simulate a small tumor volume in the lung air cavity CBCT images of the phantom were acquired in 20 different cases and compared with the image in the static status. The 20 different cases are constituted with 4 different motional ranges (0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm) and 5 different motional cycles (2, 3, 4, 5, 6 sec). The difference of CT number in the coronal image was evaluated as a deformation degree of image quality. The relative average pixel intensity values as a compared CT number of static CBCT image were 71.07% at 0.7 cm motional range, 48.88% at 1.6 cm motional range, 30.60% at 2.4 cm motional range, 17.38% at 3.1 cm motional range The tumor phantom sizes which were defined as the length with different CT number compared with air were increased as the increase of motional range (2.1 cm: no motion, 2.66 cm: 0.7 cm motion, 3.06 cm: 1.6 cm motion, 3.62 cm: 2.4 cm motion, 4.04 cm: 3.1 cm motion). This study shows that respiratory motion in the region of inhomogeneous structures can degrade the image quality of CBCT and it must be considered in the process of setup error correction using CBCT images.

  • PDF