• Title/Summary/Keyword: GateWay

Search Result 166, Processing Time 0.025 seconds

A Novel Timing Control Method for Airborne SAR Motion Compensation (항공기 요동보상을 위한 SAR시스템의 타이밍 제어 기법)

  • Lee, Hyon-Ik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.453-460
    • /
    • 2010
  • For high quality image acquisition, compensating air-vehicle motion is essential for airborne SAR system. This paper describes a timing control based motion compensation method for airborne SAR system. Efficient timing control is critical for SAR system since it maintains many timing signals and timing setting for the signals should be updated frequently. This paper proposes Timing Cluster method as an efficient means for timing control of SAR system. Moreover, this paper suggests a simple and efficient method to compensate air-vehicle motion based on the Timing Cluster method. Timing Cluster method enables SAR system to control the timing in a timing noncritical way just maintaining little amount of information.

E-feedback System Using QR Cod Tag (QR 코드 태그를 이용한 전자 피드백 시스템)

  • Ahmed, Hamdi A.;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.282-283
    • /
    • 2017
  • A government or non-governmental organization give service to their customer. Each organization have different hierarch levels. Service satisfaction surveys have become an important tool for government planners, as important in the perceived quality of service lead to great delivery of public service. When a customer gives feedback at a bottom level of organization, it is so difficult reach to higher official in time. This paper argue that, Quick Response (QR) code open up the possibility of conducting public service satisfaction at lower cost and the way feedback is directly routed to the relevant party according to their hierarchical level and gate real time feedback using specific smart phone application.

  • PDF

A Study on Comparison and Shortening of Evacuation Time Required of University Library by Simulation (시뮬레이션을 통한 대학도서관의 피난 소요시간 비교 관한 연구)

  • An, Jeong-Pill;Kim, Gwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.10-18
    • /
    • 2017
  • The University library is a reality where facilities can be a massive upset by the space of students to study space and book materials. Also, many print materials can cause fires quickly in fires, resulting in massive amounts of human casualties caused by many toxic gases. This study purpose is compares the time spent in the evacuation of the current state through the simulation, which seeks to derive a reasonable library of evacuation design, and improved inside the evacuation. As a result, the most obvious way to reduce the time required to evacuate is to diversify the evacuation routes and to disperse them. However, if the extension of the gate is not feasible, it is possible to reduce the time of escape by increasing the width of the gate and the width of the stair. If the results of this study are applied to new construction or remodeling of the library and prepare for fire evacuation, it will be a much safer library facility.

The Effect of Aquatic Gait Training on Foot Kinesiology and Gait Speed in Right Hemiplegic Patients (수중 걷기 운동이 우측 편마비 환자의 발 운동학과 보행 속도에 미치는 영향)

  • Lee, Sang-Yeol;Hyong, In-Hyouk;Shim, Je-Myung
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.674-682
    • /
    • 2009
  • The purpose of this study was to investigate the effect of aquatic gait training on plantar foot pressure, foot kinesiology and gait speed in right hemiplegic patients. The subject were 20 stroke patients who elapsed from 12 month to 24 month after stroke(aquatic gait training group(n=10), land gait training group(n=10)). This study measured plantar foot pressure, toe out angle, subtalar joint angle, gait speed from data of gate on 2m long measuring apparatus for RS-scan system(RS scan Ltd. German). This experiment performed in twice, before and after the aquatic gait training and land gait training. Collected data were statistically analyzed by SPSS Ver. 12.0 using descriptive statistics, paired t-test. Aquatic gait training group had more variety pressure area on their foot such as T1(Toe 1), HM(Heel medial), and HL(Heel lateral). But motion of subtalar joint flexibility and toe out angle decreased considerably and gate speed also increased. According to the result, aquatic gait training is considered as more effective way in foot stability and normal gait pattern than land gait training.

Design of Double-Conversion Down Mixer Using Single Half-LO Frequency at 2.3 GHz (2.3 GHz 대역에서 단일 Half-LO 주파수를 이용한 Double-Conversion Down Mixer 설계)

  • Kim Min-Seok;Moon Ju-Young;Yun Sang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.8 s.111
    • /
    • pp.719-724
    • /
    • 2006
  • In this paper, we designed the double conversion down mixer by using Half-LO frequency in 2.3 GHz band. The IF frequency is obtained by supplying two LO frequencies to HEMT in both gate type and resistive type. The proposed mixer uses Half-LO frequency the same way as conventional sub-harmonic mixers. However the proposed one uses fundamental component of Half-LO frequency in first stage instead of using second harmonic components of Half-LO frequency, and the IF frequency is obtained by resistive type mixer in second stage, thereby the proposed mixer can improve linearity in comparison with conventional active mixer. We can verify that the proposed mixer has an conversion loss of 5dBm and IIP3 of 16.25dBm by using 10 dBm Power.

Implementation of a backend system for real-time intravascular ultrasound imaging (실시간 혈관내초음파 영상을 위한 후단부 시스템 구현)

  • Park, Jun-Won;Moon, Ju-Young;Lee, Junsu;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.215-222
    • /
    • 2018
  • This paper reports the development and performance evaluation of a backend system for real-time IVUS (Intravascular Ultrasound) imaging. The developed backend system was designed to minimize the amount of logic and memory usage by means of efficient LUTs (Look-up Tables), and it was implemented in a single FPGA (Field Programmable Gate Array) without using external memory. This makes it possible to implement the backend system that is less expensive, smaller, and lighter. The accuracy of the backend system implemented was evaluated by comparing the output of the FPGA with the result computed using a MATLAB program implemented in the same way as the VHDL (VHSIC Hardware Description Language) code. Based on the result of ex-vivo experiment using rabbit artery, the developed backend system was found to be suitable for real-time intravascular ultrasound imaging.

The Emergence and Development of the Lamaist Gateway of $Lokap\bar{a}las$ during the $Jos\breve{o}n$ Dynasty - Some problems on the orientation of the Gateway of Lokapala and on the allocation of the Four Guardian Kings - (조선시대 라마계 천왕문의 수용 및 전개에 대하여 -천왕문의 배치와 사천왕 배열에 관한 문제-)

  • Yi, Dae-Am
    • Journal of architectural history
    • /
    • v.16 no.6
    • /
    • pp.47-66
    • /
    • 2007
  • $Lokap{\bar{a}}las$ are understood as the deities of four directions in Buddhism: $Dhrtar{\bar{a}}stra$ in the East, $Vir{\bar{u}}dhaka$ in the South, $Vir{\bar{u}}p{\bar{a}}ksa$ in the West and $Vai{\acute{s}}ravana$ in the North respectively. Their common name is, therefore, called as the "Four Guardian Kings", whose function is to prevent demonic forces from entering into its sacred world. Although the position of $Lokap{\bar{a}}las$ is to the lowest level in the hierarchy of the minor deities in Buddhism, the cult of $Lokap{\bar{a}}las$ was widely spread and prominent in the countries of Northern Buddhism. It played a significant role in terms of the state-protecting Buddhism, on behalf of it's esoteric and magic power. More than 20 Gateways of the $Lokap{\bar{a}}las$ and $Lokap{\bar{a}}la$ statues were still well preserved in Korea, and they were believed to be constructed after the Japanese attack in 1592. After war, monks had concentrated on restoring ruined temples and building many new Gateways of the Four Guardian Kings over the Korean peninsular. Under such circumstances, even though the $Lokap{\bar{a}}las$ played a significant role as the subject of cult in Korean Buddhism. they might have a small chance to be taught traditional Lama iconography exactly. The purpose of this essay is to examine the relation of orientation of the Gate way of $Lokap{\bar{a}}las$ and allocation of each Kings inside the gate.

  • PDF

A Study on the Buildings of 2nd Construction of Silla Bunhwangsa temple in the mid-8th century (8세기 중반 신라 분황사 중건가람 건축 연구)

  • Kim, Sookyung
    • Journal of architectural history
    • /
    • v.30 no.6
    • /
    • pp.71-80
    • /
    • 2021
  • This study tries to shed light on character and architectural features of the 2nd construction of Bunhwangsa temple in the mid-8th century. The site of Bunhwangsa Temple is divided into upper and lower areas based on retaining walls running from northwest to southeast, and the main area of the temple centered on Geumdang(the main hall) is located in the upper area. Space composition of the lower area including Wonji(a garden pond) and Gangdang(a lecture hall), is noteworthy in that Bunhwangsa Temple was constructed in a deviating way from rigorous constructional disciplines and used their space efficiently. The Geumdang in the 2nd construction was the largest worship hall with 7×6 bays. The hall was designed to divide its space into two ; the core space was surrounded by outer space. Each gap between columns in the hall was narrowed from center to outer. The main construction of the Geumdang was built as a stable structure with lead-to corridors. This was a much-advanced style than Geumdang at Hwangnyongsa Temple. The Gangdang is presumed to be a large building site as a typical Gangdang style in the Silla era. It was built in the late 9th century and was located in the northern part of the retaining walls. The composition of the middle gate and southern corridors were in double and long corridor style and they were located in front of the 2nd construction. This style coincided in the form of the architectural style of the Hwangnongsa Temple. The 2nd construction of the Bunhwangsa Temple was smaller than the Hwangnongsa Temple. However, it was a prestigious architecture.

A Study on the Basic Planning of the Nam-Hae Sin-Sa Architecture (남해신사 기본계획에 따른 신당건축 고찰)

  • Kim, Sang Tae;Jang, Hun Duc
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.2
    • /
    • pp.62-85
    • /
    • 2009
  • The Nam-Hae Sin-sa, the South Sea shrine in Yeong-Am, Korea was a national institution for public peace and bliss, was excavated in 2000, and the shrine and the 3-way-gate were reconstructed in 2001. Hae Sin-sa, the Sea shrine is a place for religious service separated into the Nam-Hae Sin-sa, the Dong-Hae Myo, and the Seo-Hae Dan. The Dong-Hae Myo was reconstructed, but restored shrine and 3-way-gate of the Nam-Hae Sin-sa is not perfect in comparison with excavation plan in 2000, therefore new reconstruction was researched through the related literature, the analysis of historical maps and excavation results, the interview with the concerned people and the case study. This research defines the analysis of the Plan of the Nam-Hae Sin-sa Reconstruction as follows. 1. The Nam-Hae Sin-sa was the institution for religious service operated by national direct management, represents the shrine for public peace and bliss on the Mountain, the Sea, and the River. Especially the Nam-Hae Sin-sa had an important position on the pivot of international trade with China and Japan, and had a role of main shrine with another one in the Mt. Ji-ri San. 2. The name of the Sea shrine was called as Nam-Hae Sin-sa(the South Sea shrine), Dong-Hae Myo(the East Sea shrine), Seo-Hae Dan(the West Sea shrine). But the name of the South Sea shrine had changed in the early period of Chosun as Nam-Hae Sin-sa to the later Chosun as Nam-Hae Dang through the research of related literature and historical map. Such as the Seo-Hae Dan, it was constructed for the Dan, the flat raised-floor without buildings, and changed to the type of Sa-Dang with addition of buildings. 3. The historical map of Hae Sin-sa informs the types of the roof, the Mat-bae roof was used in the Dong-Hae Myo, but the Pal-jak roof was showed in the Seo-Hae Dan and the Nam-Hae Sin-sa. 4. According to the analysis of Yong-Ch'uck the unit length, Nam-Hae Sin-sa was reconstructed in the period of Koryo on large scale, but it was restored in the Chosun on middle scale. And the Unit of Yong Ch'uck was changed into Yeong-jo Ch'uck in the period of Chosun. 5. As the results, The Plan of the Nam-Hae Sin-sa Reconstruction designed the new shrine into the 3 Kan front and the 2 Kan side with 3:2 scale. An-ch'o-gong with Yong-du and Yong Mi the ornaments represents head and tail of dragon, the Un-gong and the ornament of Pa-ryun-dae-gong in the building, and the Ch'ung-ryang of the Yong-du show the image of the institution for religious service for the god of the sea who look like dragon. The inner gate building and the main entrance were designed as same plan and scale as Hyang-gyo, the Korean Traditional School and Shrine of Confucianism, on the basis of results of excavation. Raise the 3-tall gate of the main entrance with harmony of the scale and the shape, because the side of gate building has the Mat-bae roof. 6. This research shows that Plan of the Nam-Hae Sin-sa Reconstruction is composed into shrine space and reservation space from the main entrance to inner gate and shrine like Jung-ak Dan in the Mt. Gye-ryong San, and it also informs the well in the west side of Sin-sa is an important factor of the plan of shrine architecture.

Asymmetric Saturated 3-Stage Doherty Power Amplifier Using Envelope Tracking Technique for Improved Efficiency (효율 향상을 위해 포락선 추적 기술을 이용한 비대칭 포화 3-Stage 도허터 전력 증폭기)

  • Kim, Il-Du;Jee, Seung-Hoon;Moon, Jung-Hwan;Son, Jung-Hwan;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.813-822
    • /
    • 2009
  • We have investigated operation of a 1:2:2 asymmetric 3-stage Doherty PA(Power Amplifier) and implemented using the Freescale's 4 W, 10 W PEP LDMOSFETS at 1 GHz. By employing the three peak efficiency characteristics, compared to the two peak N-way Doherty PA, the asymmetric 3-stage Doherty can overcome the serious efficiency degradation along the backed-off output power region and maximize the average efficiency for the modulation signal. To maximize the efficiency characteristic, the inverse class F PA has been designed as carrier and peaking amplifiers. Furthermore, to extract the proper load modulation operation, the adaptive gate bias control signal has been applied to the two peaking PAs based on the envelope tracking technique. For the 802.16e Mobile WiMAX(World Interoperability for Microwave Access) signal with 8.5 dB PAPR(Peak to Average Power Ratio), the proposed Doherty PA has shown 55.46 % of high efficiency at an average output power of 36.85 dBm while maintaining the -37.23 dB of excellent RCE(Relative Constellation Error) characteristic. This is the first time demonstration of applying the saturated PA and adaptive gate bias control technique to the asymmetric 3-stage Doherty PA for the highly efficient transmitter of the base-station application.