• 제목/요약/키워드: Gastrointestinal endoscope

검색결과 20건 처리시간 0.02초

소화기 내시경의 기술 현황과 전망 (Current and Future Technologies for a Gastrointestinal Endoscopy)

  • 지영준;우지환
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.335-343
    • /
    • 2010
  • This article presents a review of technologies for an endoscope. The classification according to the clinical applications and the imaging modalities are summarized. The major parts are focused on describing the gastrointestinal endoscope's structures and mechanisms. The details of the image enhanced endoscopic techniques, such as NBI (narrow band imaging), OCT (optical coherence tomography), and EUS (endoscopic ultrasound), are also explained. Finally, the trend of NOTES (natural orifice transluminal endoscopic surgery) which is new fusion technology in the field of endoscopic diagnosis and surgery is introduced.

내시경용 연속스티치 메카니즘 (Successive Suturing Mechanism For Gastrointestinal Endoscope)

  • 전종진;홍대희;이규백;전훈제
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1328-1331
    • /
    • 2003
  • As rates of gastric cancer. fatness. and GERD (chronic gastric esophageal reflux disease) patients have been increased in the world, suturing mechanism using endoscope has been focused. which is the medical instrument to apply stitches and suturing inside the body, since it helps the patients lessen pains and reduce operation time. This paper deals with mechanism design, which makes it possible to apply multiple suturing without the repeat of inserting and removing the endoscope. This successive suture mechanism includes gripper, linkage, rotational part, and articulation part. Also, the mechanism is operated through 4mm one-side channel attached to the endoscope by means of pulling wires.

  • PDF

Treatment Using the SpyGlass Digital System in a Patient with Hepatolithiasis after a Whipple Procedure

  • Harima, Hirofumi;Hamabe, Kouichi;Hisano, Fusako;Matsuzaki, Yuko;Itoh, Tadahiko;Sanuki, Kazutoshi;Sakaida, Isao
    • Clinical Endoscopy
    • /
    • 제51권6호
    • /
    • pp.596-599
    • /
    • 2018
  • An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.

Forward viewing liner echoendoscopy for therapeutic interventions

  • Kazuo Hara;Nozomi Okuno;Shin Haba;Takamichi Kuwahara
    • Clinical Endoscopy
    • /
    • 제57권2호
    • /
    • pp.175-180
    • /
    • 2024
  • Therapeutic endoscopic ultrasonography (EUS) procedures using the forward-viewing convex EUS (FV-EUS) have been reviewed based on the articles reported to date. The earliest reported procedure is the drainage of pancreatic pseudocysts using FV-EUS. However, the study on drainage of pancreatic pseudocysts focused on showing that drainage is possible with FV-EUS rather than leveraging its features. Subsequently, studies describing the characteristics of FV-EUS have been reported. By using FV-EUS in EUS-guided choledochoduodenostomy, double punctures in the gastrointestinal tract can be avoided. In postoperative modified anatomical cases, using the endoscopic function of FV-EUS, procedures such as bile duct drainage from anastomosis, pancreatic duct drainage from the afferent limb, and abscess drainage from the digestive tract have been reported. When a perpendicular puncture to the gastrointestinal tract is required or when there is a need to insert the endoscope deep into the gastrointestinal tract, FV-EUS is considered among the options.

국내 병원 소화기내시경 재처리과정의 적절성 (Adequacy of Reprocessing Gastrointestinal Endoscopes in Korea Hospitals)

  • 김영옥;정재심
    • Journal of Korean Biological Nursing Science
    • /
    • 제18권4호
    • /
    • pp.288-295
    • /
    • 2016
  • Background: This study was conducted in order to survey the current state of cleaning, disinfection, rinsing, drying, and storage of gastrointestinal endoscopes. Methods: Eighty hospitals were selected through convenient sampling. Self-reported questionnaire was distributed from September 14 to October 10 in 2015. Results: The response rate was 67.5% (54/80). In 88.9% of the hospitals, reprocessing was performed in a cleaning space separated from the laboratory and 88.9% used an enzymatic cleaner. Disinfectants used were ortho-phthalaldehyde in 63.0%, and paracetic acid in 33.3%. Eighty seven percent of the hospitals used test strips in order to test the effective concentration of disinfectant and in 61.1%, drying was done through passing air and over 70% alcohol. Microbial culture for the quality control of gastrointestinal endoscopes was performed in 77.8%. In the comparison of the adequacy of gastrointestinal endoscope reprocessing, it was observed that gastrointestinal endoscopes were reprocessed more adequately in larger and tertiary care hospitals. Conclusion: Gastrointestinal endoscopes were reprocessed in similar manners, but there were differences in the detailed process. It is still necessary to segment reprocessing into stages, to prepare standardized guidelines, and to monitor compliance with the guidelines.

Robotics for Advanced Therapeutic Colonoscopy

  • Wong, Jennie YY;Ho, Khek Yu
    • Clinical Endoscopy
    • /
    • 제51권6호
    • /
    • pp.552-557
    • /
    • 2018
  • Although colonoscopy was originally a diagnostic imaging procedure, it has now expanded to include an increasing range of therapeutic interventions. These procedures require precise maneuvers of instruments, execution of force, efficient transmission of force from the operator to the point of application, and sufficient dexterity in the mobilization of endoscopic surgical instruments. The conventional endoscope is not designed to support technically demanding endoscopic procedures. In case of colonoscopy, the tortuous anatomy of the colon makes inserting, moving, and orientating the endoscope difficult. Exerting excessive pressure can cause looping of the endoscope, pain to the patient, and even perforation of the colon. To mitigate the technical constraints, numerous technically enhanced systems have been developed to enable better control of instruments and precise delivery of force in the execution of surgical tasks such as apposing, grasping, traction, counter-traction, and cutting of tissues. Among the recent developments are highly dexterous robotic master and slave systems, computer-assisted or robotically enhanced conventional endoscopes, and autonomously driven locomotion devices that can effortlessly traverse the colon. Developments in endoscopic instrumentations have overcome technical barriers and opened new horizons for further advancements in therapeutic interventions. This review describes examples of some of these systems in the context of their applications to advanced therapeutic colonoscopy.

마이크로 내시경 및 첨단 광 단층촬영기법을 이용한 생체 이미징 (Endoscopic Bio-Imaging Using Optical Coherence Tomography)

  • 안예찬
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.466-471
    • /
    • 2011
  • 광 단층촬영기법은 의료영상진단 기기로 최근에 주목받고 있는 분야이다. 현재 병원 초음파보다 공간 해상도가 10-100배 우수하지만 침투깊이가 조직 내에서 1-2 mm로 얇기 때문에 인체 내 장기 이미징을 위하여서 반드시 내시경 기법을 동반하여야 한다. 본 연구를 통하여 고속 광 단층촬영기법을 소개하고 초소형 기전공학 기술을 바탕으로 개발된 내시경을 사용하여 New Zealand white rabbit의 식도와 위장 벽을 3차원으로 이미징한 결과를 고찰하였다. 개발된 내시경에는, 2축 스캔 반사경이 정전기력에 의하여 구동하는 구 동부 위에 위치하여, 입력광을 2축으로 스캔할 수 있도록 하는 구조를 포함하고 있다. 내시경의 외경은 6 mm이며 스캔 반사경의 직경은 1.2 mm 였다. 3.5초 동안 스캔하면서 3차원 이미지를 획득하였다. 3차원 이미지는 200개의 2차원 이미지를 쌓아서 구현되었으며 각각의 2차원 단면이미지는 $200{\times}500$ 픽셀들로 구성되었다. 이미지의 공간해상도는 공기 중에서 8 ${\mu}m$ 였다.

캡슐내시경으로 발견된 공장의 위장관 간질성 종양 2 예 (Two Cases of Jejunal Gastrointestinal Stromal Tumor Diagnosed by Capsule Endoscope)

  • 최재원;문희정;장병익;김태년;송선교;배영경
    • Journal of Yeungnam Medical Science
    • /
    • 제23권1호
    • /
    • pp.131-137
    • /
    • 2006
  • Small bowel tumors have been difficult to diagnose because of low incidence and absence of specific symptoms. There are no efficient and accurate tests available for diagnosis. Capsule endoscopy is an efficient diagnostic tool for small bowel disease and obscure gastrointestinal bleeding. We diagnosed two cases of small bowel gastrointestinal stromal tumor (GIST) diagnosed by capsule endoscopy that were treated by surgery. A 68 year old male presented with abdominal pain. The capsule endoscopy showed fungating ulcer mass at the jejunum. A 55 year female presented with melena. The capsule endoscopy showed an intraluminal protruding mass with a superficial ulcer at the jejunum. Two cases were diagnosed with GIST after surgery. We report these two case diagnosed by capsule endoscopy and review the medical literature.

  • PDF

The role of cap-assisted endoscopy and its future implications

  • Sol Kim;Bo-In Lee
    • Clinical Endoscopy
    • /
    • 제57권3호
    • /
    • pp.293-301
    • /
    • 2024
  • Cap-assisted endoscopy refers to a procedure in which a short tube made of a polymer (mostly transparent) is attached to the distal tip of the endoscope to enhance its diagnostic and therapeutic capabilities. It is reported to be particularly useful in: (1) minimizing blind spots during screening colonoscopy, (2) providing a constant distance from a lesion for clear visualization during magnifying endoscopy, (3) accurately assessing the size of various gastrointestinal lesions, (4) preventing mucosal injury during foreign body removal, (5) securing adequate workspace in the submucosal space during endoscopic submucosal dissection or third space endoscopy, (6) providing an optimal approach angle to a target, and (7) suctioning mucosal and submucosal tissue with negative pressure for resection or approximation. Here, we review various applications of attachable caps in diagnostic and therapeutic endoscopy and their future implications.