• Title/Summary/Keyword: Gaseous extinguishing nozzle

Search Result 3, Processing Time 0.014 seconds

Influence of the Nozzle Contraction Angles of Gaseous Extinguishing Systems on Discharge Noise (가스계 소화시스템 노즐 수축각이 방출소음에 미치는 영향)

  • Kim, Yo-Hwan;Yoo, Han-Sol;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.77-82
    • /
    • 2019
  • Fire extinguishing systems are essential equipment in all indoor facilities to address unexpected fire scenarios, and appropriate fire extinguishing agent should be used depending on the place and object to protect. Among these, gaseous fire-extinguishing systems are used to protect electronic equipment. Therefore, inert gases that do not undergo chemical reactions are used mainly in those systems. On the other hand, recently, owing to the high integration of electronic equipment, there are some cases, in which large noise generated from gaseous systems damage the electronic equipment. In this study, numerical analysis of the discharge noise with various nozzle contraction angles was carried out to improve the gas fire extinguishing system. Numerical analysis was carried out using ANSYS FLUENT ver 18.1. The causes of the noise were elucidated using the swirl distribution. The noise level of the modified model was reduced by approximately 6 dB compared to the reference model, which is similar to the result of a previous study, confirming the validity of the method.

Effect of Absorbent Thickness on the Noise Level Reduction of Fire-Extinguishing Nozzle (흡음재 두께가 소화노즐 소음도 저감에 미치는 영향)

  • Kim, Hak-Sun;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.99-104
    • /
    • 2019
  • In a gas system fire extinguishing system, extinguishing agents are usually stored with approximately 280 bar at $21^{\circ}C$ and are released at approximately 8 MPa through the decompression valve and orifice to quickly suppress the fire. When extinguishing agents are discharged, they cause a loud noise (approximately 140 dB), which can damage electronics, such as hard disk drives (HDDs). Therefore, the noise is becoming a serious issue in the gas extinguishing system. The method of the noise reduction by adding an absorbent is most general and in this study, the thickness of the absorbent was as a selected design variable. The noise level at the observation point and the flow characteristics inside the nozzle were numerically calculated and analyzed using the commercial code ANSYS CFX ver. 18.1.

Application of Optimal Design Method to Agent Discharge Flow Calculation of Gaseous Fire Extinguishing Systems (최적설계법을 응용한 가스계 소화설비의 약제방출량 산출)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.51-56
    • /
    • 2015
  • In this study, optimal design methods were applied to the agent discharge flow of clean agent fire extinguishing systems. The methods combined optimal design theory and engineering theory for engineering analysis in a design program or coast savings in value engineering. Optimal design parameters were determined to optimize the agent discharge flow based on the design theory of the clean agent fire extinguishing systems and the theory of optimal design. The design factors were verified in regard to suitability for the performance of fire extinguishing systems. The results provide a foundation for optimal design method methods in other fire extinguishing systems. Optimization of the agent discharge flow of the discharge nozzle was confirmed by the constraints on the inner diameter of the discharge nozzle and the pipe, agent arrival time, flow, and pressure variation of the agent. The deviation of discharge pressure and agent time of the agent discharge nozzle were found to correlate with the pressure variation.