$SF_6$ 가스중 PET Film의 절연특성 (Insulated Characteristics of PET Film under $SF_6$)

  • 김정달;정장근;주성철;이덕진;박재윤;이용길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2120-2122
    • /
    • 1999
  • $SF_6$ gas has been widely used the gas insulated transmission line, gas insulated transformer and gas insulated substation and Polyester film used as the turn insulation with other material. $SF_6$ gas has been actively studied in domestic and foreign countries. In general, when dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents the insulation strength of turn insulation of $SF_6$-PET film studied under application of AC voltage, constitute of the plane to plane with PET Film. The results obtained in experimental are summarized that Partial Discharge Initial Voltage(PDIV) of turn insulation depend on gas pressure, but Breakdown Voltage(BDV) did not depend on gas pressure.

  • PDF

$SF^6 $ 가스변압기의 탭절환기용 스페이서의 절연내력에 관한 연구 (A study of Dielectric Strength of Spacer for Tap Changer in a $SF^6 $ Gas Insulated Transformer)

  • 허우행;하영식;홍정균;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권11호
    • /
    • pp.556-562
    • /
    • 2001
  • Spacer is used between main tank and auxiliary tank for on load tap changer in gas insulated power transformer. This paper deals with electrical design of spacer and discusses different analysis method of between 2D FEM(finite element method) and 3D FEM. To design spacer, we modeled structure of two kind of coaxial cylinders of spacer conductors and analysised electric field of spacer at impulse and induced test voltage condition. Spacer has 13 conductors and electric field was changed according to arrangement of conductors. We could find out arrangement of conductors at which electric stress is minimum. And this arrangement was satisfied with actual test conditions.

  • PDF

Fluorocarbon에서의 변압기권선 절연용 PET필름의 전기적 특성연구 (Electrical characteristics of PET film for wire insulation of transformer in fluorocarbon)

  • 허창수;이재복
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권5호
    • /
    • pp.483-489
    • /
    • 1996
  • Power transformer have many unsymmetrical structure and electric field is enhanced in that area. Those unsymmetrical area are not covered oftenly by solid insulating material which is used as a framework specially in gas transformer. By that result there is a possibility to decrease the total insulation class of the transformer. So in this study the electrical characteristic of $FC+SF_6$ mixture gas which is used as coolants for large power gas insulated transformer and its effects on electrical characteristics of structural material are investigated. Also breakdown characteristic with the tension of taping and curvature of the coil are studied which could be used as a design factor of large power transformer.

  • PDF

Digital Time-Domain Simulation of Ferroresonance of Potential Transformer in the 154 kV GAS Insulated Substation

  • Shim, Eung-Bo;Woo, Jung-Wook;Han, Sang-Ok
    • KIEE International Transactions on Power Engineering
    • /
    • 제11A권4호
    • /
    • pp.9-14
    • /
    • 2001
  • This paper reports a set of digital time-domain simulation studies conducted on 154 kV wound Potential Transformer(PT) int he 154 kV Gas Insulated Substation(GIS). The Electro-Magnetic Transient Program(EMTP) is used to develop the PT model and conduct the transient studies. The accuracy of the PT model is verified through comparison of the EMTP simulation results with those obtained from the field test results. The investigations shows that the developed model can accurately predict PT transient resonance, especially, the phenomenon of ferroresonance. The model is developed not only to determine impact of transients on PT response but also to design ferroresonance suppressor devices of PT. And it can also be used to predict PT transient response on power system monitoring and protection scheme.

  • PDF

가스절연 변압기용 열교환기의 열전달 및 압력손실 특성 연구 (Heat Transfer and Pressure Drop Characteristics of Heat Exchanger for a Gas-insulated Transformer)

  • 함진기;이준엽;김영기;송석현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1046-1051
    • /
    • 2004
  • A plate-fin-tube heat exchanger used for a $SF_{6}$ gas-insulated transformer is extremely important since the dissipation of the heat generated from inside coils has a significant effect on the performance as well as the durability of the transformer. The heat exchanger consists of corrugated plate fins and staggered array tube bundles for coolant. In order to find out heat transfer and pressure drop characteristics, series of numerical analyses for plate fins with enhanced surface geometries were conducted. Based on the results of the numerical analyses, an improved model of the plate fin has been proposed.

  • PDF

가스절연개폐장치의 스페이서 내장형 전자식 변압기의 설계 및 제작 (Design and Fabrication of an Electronic Voltage Transformer (EVT) Embedded in a Spacer of Gas Insulated Switchgears)

  • 임승현;김남훈;김동언;김선규;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.353-358
    • /
    • 2022
  • Bulky iron-core potential transformers (PT) are installed in a tank of gas insulated switchgears (GIS) for a system voltage measurement in power substations. In this paper, we studied an electronic voltage transformer (EVT) embedded in a spacer for miniaturization, eco-friendliness, and performance improvement of GIS. The prototype EVT consists of a capacitive probe (CP) that can be embedded in a spacer and a voltage Follower with a high input and a low output impedance. The CP was fabricated in the form of a Flexible-PCB to acquire the insulation performance and to withstand vibration and shock during operation. Voltage ratio of the prototype EVT is about 42,270, and the frequency bandwidth of -3 dB ranges from 0.33 Hz to 3.9 MHz. The voltage ratio error evaluated at about 6%, 12% and 18% of the rated voltage of 170 kV was 0.32%, and the phase error was 12.9 minutes. These results were within the accuracy for the class 0.5 specified in IEC 60044-7 and satisfy even in ranges from 80% to 120% of the rated voltage. If the prototype EVT replaces the conventional iron-core potential transformer, it is expected that the height of the GIS could be reduced by 11% and the amount of SF6 will be reduced by at least 10%.

$SF_6$ 가스절연변압기에서 권선의 섹션에 대한 절연내력 연구 (A Study on the Dielectric Strength in Section of Winding in SF6 Gas Transformer)

  • 허우행;하영식;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.152-158
    • /
    • 2000
  • This paper deal with the experimental discussion about the impulse and AC dielectric strength of SF6 gas insulated transformer. Test sample is measured the dielectric breakdown voltage about modeling of the first and second section which is the weakest for surge voltage. The AC breakdown voltage is appeared 1.4 times than impulse breakdown voltage, so we can estimate that the impulse breakdown voltage is severe to AC breakdown voltage, and when the impulse is applied, in case of lmm tapping with Nomex paper, the characteristics of dielectric breakdown voltage is same to that in oil immersed transformer when SF6 gas pressure is 2.2kg/$cm^2$G.

  • PDF

Gas 색연(絶綠) 개폐장치(開閉裝置)의 철공진(鐵共振) 제어대책(制御對策)에 관한 연구(硏究) (A Study on the Elimination of Temporary overvoltage Due to Ferroresonance at Gas Insulated Switchgear)

  • 김승규;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.216-221
    • /
    • 2000
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP(Electro- magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computationl model.

  • PDF

특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구 (A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System)

  • 정흥수;김민영;김준석
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.36-46
    • /
    • 2008
  • 본 논문은 대전력시험설비를 이용한 특고압 가스 절연 부하 개폐기의 대전력 시험회로의 구성과 통합형 시험 방법에 관하여 연구하였다. 대전력시험설비는 전기기기의 전기적 및 기계적인 성능을 검증하는 설비로서 단락발전기, 보호차단기, 투입스위치, 임피던스, 고압변압기, 저압변압기, 측정 및 보호시스템 등으로 구성되며, 이 시스템을 이용하여 단시간전류시험, 전류개폐용량시험, 단락투입 및 차단시험 등을 실시한다. 특고압 가스 절연 부하 개폐기의 규격으로는 국내 배전계통에 적용되는 ES(한국전력공사 표준규격) 5925-0002가 있으며, 국제 규격으로는 IEC 60265-1, 62271-1 및 IEEE C 37.74 등이 있다. 본 논문에서는 여러 규격에 각각 규정되어 있는 시험 절차, 시험회로 구성 및 시험 방법 등을 통합하여 600[MVA]급 대전력 시험설비에 적용하였다.

345kV 승압용 변전소의 뇌격에 의한 이상전압 해석 (Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer)

  • 조만영;신호전;허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.