• 제목/요약/키워드: Gas tube

검색결과 1,057건 처리시간 0.03초

수평관내 초임계 영역의 Co2 냉각 열전달 특성 (Heat Transfer Characteristics During Gas Cooling Process of Carbon Dioxide in a Horizontal Tube)

  • 손창효;이동건;오후규;정시영;김영률
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.289-295
    • /
    • 2004
  • The heat transfer coefficient and pressure drop during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flowmeter, an evaporator, and a gas cooler(test section). The main components of the water loop consist of a variable-speed pump, an isothermal tank, and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal stainless steel tube of the outer diameter of 9.53mm and of the inner diameter of 7.75mm. The length of the test section is 6m. The refrigerant mass fluxes were 200∼300kg/(m2$.$s) and the inlet pressure of the gas cooler varied from 7.5㎫ to 8.5㎫. The main results were summarized as follows : Pressure drop of CO2 increases with increasing gas cooler pressure. The friction factors of CO2 in a horizontal tube show a relatively good agreement with the correlation by Blasius. The heat transfer coefficient of CO2 in transcritical region increases with decreasing gas cooler pressure and decreasing mass flux of CO2. Most of correlations proposed in a transcritical region showed significant deviations with experimental data except for those predicted by Gnielinski.

수소운송설비 안전성 강화 방안 고찰 (A Study on the Safety Enhancement of Hydrogen Tube Trailer)

  • 박우일;김영훈;이인우;강승규
    • 한국가스학회지
    • /
    • 제26권6호
    • /
    • pp.59-64
    • /
    • 2022
  • 현재 수소운송설비는 2022년 10월 말 기준 787대가 운행 중이며, Type 1 이음매 없는 용기에 최대 200 bar의 압력으로 1회 최대 340 kg을 운송한다. 현재 안전관리체계 및 설비관리는 양호한 상태이나, 안전성 강화를 위해 제도 및 설비 구조개선이 필요한 실정이다. 이에 따라, 본 논문은 수소에너지 활성화 정책에 의해 수소운송설비 보급·운영의 확대 과정 중 지난 2021년 12월 28일 대전-당진간 고속도로에서 발생한 사고사례를 모사 및 해석을 진행하였으며, 사고 분석 및 해석 결과에 따라 수소운송설비의 안전성 향상 방안에 대해 제언하였다.

초임계 $CO_2$의 헬리컬 코일관 내 열선단과 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube)

  • 유태근;김대희;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.353-358
    • /
    • 2005
  • The heat transfer and pressure drop of supercritical $CO_2$ cooled in a helically coiled tube was investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The experimental apparatus of the refrigerant loop consist of receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a helically coiled tube in tube counter flow heat exchanger with $CO_2$ flowed inside the inner tube and coolant( water) flowed along the outside annular passage, It was made of it copper tube with the inner diameter of 4.55[mm]. the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were $200^{\sim}600$ [kg/m2s] and the inlet pressure of gas cooler varied from 7.5 [MPa] to 10.0 [MPa]. The main results are summarized as follows : The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF

Numerical Prediction of the Flow Characteristics of a Micro Shock Tube

  • ;;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.178-181
    • /
    • 2011
  • Recently, micro shock tube is being extensively used in various fields of engineering applications. The flow characteristics occurring in the micro shock tube may be significantly different from that of conventional macro shock tube due to very low Reynolds number and Knudsen number effects which are, in general, manifested in such flows of rarefied gas, solid-gas two-phase, etc. In these situations, Navier-Stokes equations cannot properly predict the micro shock tube flow. In the present study, a two-dimensional CFD method has been applied to simulate the micro shock tube, with slip velocity and temperature jump boundary conditions. The effects of wall thermal conditions on the unsteady flow in the micro shock tube were also investigated. The unsteady behaviors of shock wave and contact discontinuity were, in detail, analyzed. The results obtained show much more attenuation of shock wave, compared with macro-shock tubes.

  • PDF

맥동관의 엔탈피유동에 대한 2차원 해석 (Two-Dimensional Analysis of Enthalpy Flow in a Pulse Tube)

  • 백상호;장승철;정은수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.42-47
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass. momentum an energy equations of the gas as well as energy conservation of the tube wall. The mean temperature of the gas and the tube wall was obtained directly by assuming that the outer surface of a pules tibe wall is adiabatic. Axial profile of mean temperature is small. but it deviates significantly from linear profile when the dimensionless frequency is large. Effect of operating frequency. tube wall thickness, velocity ratio and velocity phase angle between both ends of a pulse tube on net enthalpy flow were shown.

  • PDF

기포탑에서 점성수용액의 가스전달에 관한 연구 (A Study on Gas Transfer of Viscous Aqueous Solutions in a Bubble Column)

  • 최일곤;김상렬
    • 한국안전학회지
    • /
    • 제9권3호
    • /
    • pp.67-73
    • /
    • 1994
  • The gas holdup and volumeteric liquid phase mass transfer coefficient with the variation of the concentration of CMC aqueous solution, gas velocity, diameter and area of the draught tube were investigated. As the results of the experiments, the gas holdup and volumetric liquid phase mass transfer coefficient decreased with decreasing the concentration of CMC aqueous solution, increased with increasing the gas velocity and increased with increasing the circulated area ratio of the draught tube.

  • PDF

배기통과 가스보일러 접속부의 내열실리콘 성능에 관한 실험적 연구 (An Experimental Study on Performance of Heatproof Silicon at the Connector of Boiler Exhaust Tube)

  • 임사환;이종락;김철진;한귀호;김용주;김희수;장원석;임청환
    • 한국가스학회지
    • /
    • 제11권4호
    • /
    • pp.91-97
    • /
    • 2007
  • 최근 5년간 가스보일러 사고를 살펴보면 도시가스가 LP가스보다 7.4배 많이 발생하고 있다. 이는 도시 가스보일러사용이 늘어나게 되어 사고율이 증가하는 것으로 보인다. 이러한 보일러 사는 CO 중독에 의한 사고가 87%로 가장 많이 발생하였으며, 타형태의 시보다 인명피해가 4.3배가 높게 나타났다. 따라서 본 연구에서는 CO 중독의 원인인 배기통 분리에 의한 원인을 규명하고, 현재 사용하고 있는 내열실리콘의 성능에 대하여 실험을 통하여 안전성을 입증하자 한다. 실험결과 일반실리콘은 $56^{\circ}C$에 경화가 시작되었으나, 내열실리콘을 $606^{\circ}C$가 되어도 탄화되지 않았다. 또한 배기통의 일반적인 온도인 $150^{\circ}C$에서 일반실리콘은 열화 후 기밀시험에서 누출이 발생하였으나, 내열실리콘은 본래의 성질을 유지하고 있었다. 따라서 배기통 연결부에 내열실리콘을 사용하면 CO 중독으로 인한 인명피해 사고를 줄일 수 있을 것으로 판단된다.

  • PDF

연료극 지지체식 원통형 고체산화물 연료전지의 제조 및 특성연구 (Fabrication and Characteristics of Anode-Supported Tubular Solid Oxide Fuel Cell)

  • 김응용;송락현;신동열;임영언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1547-1549
    • /
    • 1999
  • As a preliminary experiment for the development of anode-supported tubular cell with proper porosity, we have investigated the anode substrate and the electrolyte-coated anode tube. The anode substrate was manufactured as a function of carbon content in the range of 20 to 50 vol.%. As the caron content increased, the porosity of the anode substrate increased slightly and the carbon content with proper porosity was obtained at 30 vol.%. The anode tube was fabricated by extrusion process and the electrolyte layer was coated on the anode tube by slurry dipping process. The anode-supported tube was cofired successfully. Their sintered property and microstructure were examined and the porosity of the anode tube was 35%. From the gas permeation test, the anode tube was found to be porous enough for gas supply. On the other hand, the anode-supported tube with electrolyte layer indicated a very low gas permeation rate. This means that the coated electrolyte was dense. Based upon these experimental results. we will fabricate and test the anode-supported tubular cell.

  • PDF

발전용 보일러 주증기 튜브 과열방지용 오리피스 설계기법 (The design method of overheat protection orifice for power plant boiler super heated tube)

  • 김범신;유성연;하정수;김의현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.373-378
    • /
    • 2003
  • It is important that overheat protection of super heated tube in boiler operation and maintenance. The overheat of super heat tube can make damage and rupture of tube material, which causes accidental shutdown of boiler. The super heated tube overheat is almost due to the lack of uniformity of gas temperature distribution. There are two ways to protect overheat of super heated tube. The one is to control hot gas operation pattern which is temperature or flow distribution. the other is to control super heated steam flow distribution. The former is difficult than the later, because of control device design. In this paper steam flow control method which uses orifices is proposed to protect overheat of super heat tube.

  • PDF

초고온가스로의 동심축 이중관형 고온가스덕트에 대한 구조정산 방법론 제안 (Suggestion of Structural Sizing Methodology on a Coaxial Double-tube Type Hot Gas Duct for the VHTR)

  • 송기남;김용완
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.717-724
    • /
    • 2008
  • Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting the reactor pressure vessel and the intermediate heat exchanger for the VHTR. In this study, structural sizing methodology for the primary HGD with a coaxial double-tube of the VHTR that produces heat at temperatures in the order of $950^{\circ}C$ was suggested and a structural pre-sizing of it was carried out as an example.

  • PDF