• 제목/요약/키워드: Gas safety education

검색결과 83건 처리시간 0.022초

A Study on the System and Operation of Laboratory Safety Inspection and Diagnosis (연구실 안전점검 및 정밀안전진단제도 개선에 관한 연구)

  • Woo, In-Sung;Hwang, Myung-Hwan;Lee, Hong-Ju
    • Journal of the Korean Institute of Gas
    • /
    • 제23권2호
    • /
    • pp.45-54
    • /
    • 2019
  • According to the Laboratory Safety Act, each laboratory in the field of science and technology must conduct safety inspections and diagnosis every year or every two years. At present, the relevant guidelines are not clear, so there is a high possibility that inspection and diagnosis will become ineffective. In the laboratory, there is a pre-risk factor analysis system for hazardous factors, but there are many difficulties in implementation due to lack of education and understanding of the researchers, excessive work, etc. For the analysis of the opinions of experts in the safety field using the Delphi technique, we analyzed the following items: 1. Consideration in applying the Lab Safety Act, 2. Consideration in Lab Safety inspection and diagnosis, and 3. Government policy necessary for Lab. safety. Through the investigation and analysis of the detailed items, we extracted for problems and alternatives in current laboratory safety diagnosis and current law.

Development of a Deep Learning Prediction Model to Recognize Dangerous Situations in a Gas-use Environment (가스 사용 환경에서의 위험 상황 인지를 위한 딥러닝 예측모델 개발)

  • Kang, Byung Jun;Cho, Hyun-Chan
    • Journal of the Semiconductor & Display Technology
    • /
    • 제21권1호
    • /
    • pp.132-135
    • /
    • 2022
  • Recently, with the development of IoT communication technology, products and services that detect and inform the surrounding environment under the name of smart plugs are being developed. In particular, in order to prepare for fire or gas leakage accidents, products that automatically close and warn when abnormal symptoms occur are used. Most of them use methods of collecting, analyzing, and processing information through networks. However, there is a disadvantage that it cannot be used when the network is temporarily in a failed state. In this paper, sensor information was analyzed using deep learning, and a model that can predict abnormal symptoms was learned in advance and applied to MCU. The performance of each model was evaluated by developing firmware that can judge and process on its own regardless of network and applying a predictive model to the MCU after 3 to 120 seconds.

Assessment of Questionnaire of Physical Activity at Workplace Based on the Social Cognitive Theory (PAWPQ-SCT): A Psychometric Study in Iranian Gas Refinery Workers

  • Kamel Ghobadi;AhmadAli Eslami;Asiyeh Pirzadeh;Seyed Mohammad Mazloomi;Fatemeh Hosseini
    • Safety and Health at Work
    • /
    • 제14권4호
    • /
    • pp.358-367
    • /
    • 2023
  • Background: This study aimed to develop and assess the psychometric features of the Physical Activity at Workplace Questionnaire (PAWPQ) based on the Social Cognitive Theory (SCT) to evaluate employees' physical activity (PA) behaviors at the workplace. Methods: This psychometric cross-sectional study was conducted on 455 employees working in one of the gas refineries in Iran. The participants were selected using the proportional stratified sampling method in 2019. The data collection tools were a demographic information questionnaire, the short form of the International Physical Activity Questionnaire (IPAQ), and a questionnaire developed based on the SCT, whose psychometric features were confirmed in terms of validity and reliability. Data were analyzed using SPSS22 and AMOS20 software. Results: The first version of PAWPQ-SCT had 74 items. After evaluating content and face validity, nine items were removed. The results of the content validity index (0.98), content validity ratio (0.86), and impact score (3.62) were acceptable for the whole instrument. In exploratory factor analysis, after removing seven items-58-item final version of the scale-six factors could explain 73.54% of the total variance. The results of structural equation modeling showed the acceptable fit of the model into the data (RMSEA = 0.052, CFI = 0.917, NFI = 0.878, TLI = 0.905, IFI = 0.917, CMIN/DF = 2.818). Cronbach's alpha coefficient and Intraclass Correlation were 0.90 and 0.86, respectively. Conclusion: This study confirmed that the psychometric features of the 58-item final version of PAWPQSCT constructs were acceptable in a sample of Iranian employees. This questionnaire can be used as a valid and reliable tool to evaluate Iranian employees' PA behaviors and develop effective educational interventions for workers and managers.

A Study on the BOG Re-liquefaction System based on the Reverse Brayton Refrigeration Cycle for LNG Carriers (역 브레이튼 냉동사이클을 이용한 LNG 운반선의 증발기체 재액화 시스템에 관한 연구)

  • Chin, Young-Wook
    • Journal of the Korea Safety Management & Science
    • /
    • 제9권4호
    • /
    • pp.149-154
    • /
    • 2007
  • The LNG carriers have been propelled by steam turbines and the LNG boil-off(BOG) has been used as fuel or vented. However, as the alternative propulsion systems such as diesel engines are being equipped on the LNG carriers for better fuel efficiency, a need for the LNG BOG re-liquefaction system that liquefies the BOG and sends the liquid BOG back to the LNG cargo has arisen in recent years. This study investigates the design of the BOG re-liquefaction system based on the reverse Brayton refrigeration cycle. The thermodynamic and heat exchanger analysis are carried out and the limitations to the system performance are discussed.

A Study on the Optimum of Safety for a LPG Storage Tank using TRIZ (TRIZ를 활용한 LPG 저장탱크의 안전성에 관한 최적화방안)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Proceedings of the KAIS Fall Conference
    • /
    • 한국산학기술학회 2008년도 춘계학술발표논문집
    • /
    • pp.49-51
    • /
    • 2008
  • 가스의 수요가 늘어나면서 대량수요처에 대한 위험성과 안전성을 확보하기 위한 노력이 필요한 시점이다. 본 연구에서는 LPG저장탱크의 안전성과 경제성을 고려한 저장탱크를 파악하기 위하여 TRIZ 기법을 활용하였다. 지상형은 화염 등에 의한 위험성이 높으며, 지하매몰형은 부식 등에 의한 경제적 손실이 크다. 따라서 지상형과 매몰형에 대한 문제점을 해결하기 위해 6SC(6 Step Creativity)을 응용하였으며, 그 결과 지하격납형을 도출하였다.

  • PDF

The Current technology state of "Supervisory Control And Data Acquisition System(SCADA)" and development plan in the city-gas industry (긴급제언 - 원격감시제어시스템의(SCADA) 기술현황과 도시가스산업에서의 발전방안)

  • Choi, In-Hwan
    • Journal of the Korean Professional Engineers Association
    • /
    • 제43권3호
    • /
    • pp.28-33
    • /
    • 2010
  • The related industrial technologies are also being developed in medicine, education, the military, transportation, process management, security management and information technology industries due to a rapid progress in telecommunications technology. The supervisory remote control system is based upon telecommunications technology. The supervisory remote control systems are used in various ways such as city gas, water supply and drainage, environment, power, communication and device control fields. The supervisory remort control system became a solution with complex systems and important technologies in electricity, city gas filed that require safety management skills. The supervisory remote control system as a special technology has a lot of practical applications. In this paper, Let me examine the present status of remort control system applications and present development plans and alternatives in city-gas industrial technology.

  • PDF

A Study on the Quantitative Analysis for Explosion of LPG Storage Tank (LPG 저장탱크의 폭발에 대한 정량적 영향평가에 관한 연구)

  • Leem, Sa Hwan;Huh, Yong Jeong
    • Journal of the Korean Institute of Gas
    • /
    • 제17권3호
    • /
    • pp.1-7
    • /
    • 2013
  • The influence of the over-pressure caused by Explosion in gas station was calculated by using the Hopkinson's scaling law and injury effect by accident to buildings and human bodies was estimated by applying the probit model. As a result, the injury estimation was conducted by using the probit model for leakage 10% of 20ton storage tank. The separate distances from LPG station for building(damage) and human(lung hemorrhage to death) are 260 and 30 meters, respectively.

Optimization of Explosion Prevention for LPG Storage Tanks (폭발방지를 고려한 LPG 저장탱크 최적설계)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Son, Seok-Woo;Lim, Jae-Ki;Lee, Jong-Rark
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제34권7호
    • /
    • pp.897-903
    • /
    • 2010
  • Used gas to the vehicle fuel are the problems of the 'survival' beyond the 'quality of life' improvements and revive a new paradigm of 'sustainable development' which pursues economic development in harmony with environmental conservation. However, the fatalities caused by explosions and fires increases every year with the increase in the use of LPG; gas accidents in large-scale storage facilities also cause severe damage to property. In this study, a suitable storage tank is designed in which the surface area of the fuel exposed to flames is minimized in order to prevent explosions; thus, the occurrences of explosions in underground storage tanks can be minimized. According to the optimum design of storage tank obtained in this study, underground containment space was minimized; the minimized diameter and length of a 20-ton storage tank was 3 m and 4.83 m, respectively. Thus, safety was ensured since surface area exposed to flames decreased by 89.4%, which is less than the exposed surface area in the currently used storage tanks.

Performance Evaluation of Hazardous Substances using Measurement Vehicle of Field Mode through Emergency Response of Chemical Incidents

  • Lee, Yeon-Hee;Hwang, Seung-Ryul;Kim, Jae-Young;Kim, Kyun;Kwak, Ji Hyun;Kim, Min Sun;Park, Joong Don;Jeon, Junho;Kim, Ki Joon;Lee, Jin Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • 제34권4호
    • /
    • pp.294-302
    • /
    • 2015
  • BACKGROUND: Chemical accidents have increased owing to chemical usage, human error and technical failures during the last decades. Many countries have organized supervisory authorities in charge of enforcing related rules and regulations to prevent chemical accidents. A very important part in chemical accidents has been coping with comprehensive first aid tool. Therefore, the present research has provided information with the initial applications concern to the rapid analysis of hazardous material using instruments in vehicle of field mode after chemical accidents. METHODS AND RESULTS: Mobile measurement vehicle was manufactured to obtain information regarding field assessments of chemical accidents. This vehicle was equipped with four instruments including gas chromatography with mass spectrometry (GC/MS), Fourier Transform Infrared Spectroscopy (FT-IR), Ion Chromatography (IC), and UV/Vis spectrometer (UV) to analyses of accident preparedness substances, volatile compounds, and organic gases. Moreover, this work was the first examined the evaluation of applicability for analysis instruments using 20 chemicals in various accident preparedness substances (GC/MS; 6 chemicals, FT-IR; 2 chemicals, IC; 11 chemicals, and UV; 1 chemical) and their calibration curves were obtained with high linearity ( r 2 > 0.991). Our results were observed the advantage of the high chromatographic peak capacity, fast analysis, and good sensitivity as well as resolution. CONCLUSION: When chemical accidents are occurred, the posted measurement vehicle may be utilized as tool an effective for qualitative and quantitative information in the scene of an accident owing to the rapid analysis of hazardous material.

A Study on Improvement of Professional Fire Investigation Education and Certification System (화재조사전문교육 및 자격증제도 개선에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • 제23권5호
    • /
    • pp.32-42
    • /
    • 2009
  • This study aims to analyze operation status of the professional fire investigation education in Korea and derive improvement measures. Study results showed that professional fire investigation educations are conducted mainly by public sectors (Fire Service, Police, Korea Electrical Safety Corp, Korea Gas Safety Corp, etc.) and the educations conducted by National Fire Service Academy are most systematic. In addition, there was no professional fire investigation educations conducted for private sector (fire accident suffers, common peoples, etc.) In order to improve the problems, this study suggests changing the National Fire Service Academy to lifelong education system in coordinance with the scholar's courses of universities, classifying the fire inspector qualification course (executed by National Emergency Management Agency) in five stages, and opening the fire inspector qualification test to the public.