• 제목/요약/키워드: Gas safety check

검색결과 55건 처리시간 0.024초

오리피스 유량계에서 게이지라인 누설에 의한 계량오차 (The Measurement Error owing to Leakage of Gaugeline in Orifice Flowmeter)

  • 이철구;하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.143-148
    • /
    • 2003
  • This study was experimentally performed in order to estimate the errors due to the leakage of transmitter gaugelines in the orifice flow meter for natural gas. It would be a serious problem in safety if a large quantity of leak was occurred at the tubes or fittings like valve. But in most cases the safety problems might be rarely happened because the gas leak detectors could be operated in advance and the various kinds of inspection would be also fulfilled periodically. If the leakage was occurred continuously with an undetectable amount at the gaugelines for measuring the pressure or the differential pressure(DP), the amount of leakage might be an error or an unaccounted flow(UAE). In addition if the measuring value of pressure or DP were affected by the leakage, it might also be a measurement error. The experiments were performed to estimate the amount of leakage and to check the DP changes if it exited. First, through the measurement of the air pressure changes in the airtight container connected to a transmitter with gaugelines as the time passed, the amount of leakage causing from the fittings of gaugelines was roughly estimated. As changing the leak position of the gaugeline, the leak was intentionally made to break out. The variance of DP was checked as controlling the extent of leakage and compared to no leak conditions. Consequently, under the normal maintenance conditions, the result represented that the amount of leakage causing from the gaugelines was insignificant and also the DP changes on leakage conditions were too small to cause the errors of measurements.

  • PDF

알코올을 주성분으로 하는 손소독제의 안전성 연구 (A Study on the Safety of Alcohol-based Hand Sanitizers)

  • 정선옥;이춘영;류회진;최희진;김지영;최채만;황인숙;신용승
    • 한국산업보건학회지
    • /
    • 제33권1호
    • /
    • pp.34-39
    • /
    • 2023
  • Objectives: In this study, the safety of alcohol-based hand sanitizers (ABHSs) for quasi-drugs and cosmetics was investigated by analyzing the ethanol content, which is an active ingredient with a sterilizing effect, and methanol, which is toxic. Methods: Forty-one ABHSs were purchased at large supermarkets and online stores. Ethanol quantification was performed by gas chromatography-flame ionization detector, and methanol quantification was performed by headspace-gas chromatography-mass spectrometry. Results: The ethanol content of ABHS in quasi-drugs was 49.6-67.8%, which was suitable for standard manufacturing procedures for external disinfectants, and the ethanol content of ABHS in cosmetics was 9.1-61.3%. The methanol content of ABHS in quasi-drugs ranged from not detected(N.D.)-131.8 ppm, which was suitable for the methanol detection standard of ethanol raw materials in the Korean Pharmacopoeia. The methanol content of ABHS in cosmetics was 23.4-859.7 ppm, which was suitable for the detection limit of methanol in cosmetics. Conclusions: The ethanol and methanol content of ABHS was judged to be safe. When selecting an ABHS to be used for sterilization, it seems necessary to check the content of ethanol, an active ingredient, and use it according to its intended purpose.

CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구 (A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

케스케이드 방식 압축시스템 기반의 수소충전소에 대한 정성적 위험성평가 (Consequence Analysis of Hydrogen Filling Stations based on Cascade Compressing Systems)

  • 안병준;임종국
    • 한국가스학회지
    • /
    • 제25권2호
    • /
    • pp.13-21
    • /
    • 2021
  • 최근 수소자동차 보급의 확대로 수소충전소의 설치가 점차 확대될 예정이다. 본 연구에서는 수소충전소의 최악의 상황을 가정한 시나리오를 기반으로 피해규모를 예측하고 보다 안전한 설계형태를 제안하고자 한다. 피해규모 예측 방법은 전산유체역학(CFD)을 이용한 Flacs solver를 사용하였으며 이전 연구자의 실험 결과와 비교하여 정확성을 검증하였다. 피해규모 예측은 수소누출과 폭발에 대해서 실시하였으며, 예측 대상은 실측치를 기반으로 한 KR model로 하였다. 그리고 비교검토 모델로는 천정이 없는 형태인 Roofless model을 선정하였다. 두 모델에 대하여 분석한 결과 KR model에서는 내부가 60 vol% 이상까지 수소가스가 누적·체류되는 현상을 확인 할 수 있었던 반면, Roofless model의 경우에는 누출 후 벽면을 타고 충전소 외부로 방출·확산되는 현상을 확인 할 수 있었다. 결론적으로 국내에 표준모델로 보급·확산되고 있는 수소충전소 모델보다는 천정이 없는 수소 충전소 형태가 안전상 유리한 것으로 검토되었다.

비파괴 기술을 이용한 대구경 수도용 밸브의 상태평가에 관한 연구 (A study on the condition assessment of large diameter water valves using non-destructive technologies)

  • 이호민;최현용;박수완;오태민;김채민;배철호
    • 상하수도학회지
    • /
    • 제37권4호
    • /
    • pp.215-229
    • /
    • 2023
  • In this study, non-destructive technologies that can be applied to evaluate the integrity of valve materials, safety against internal pressure caused by corrosion, and the blocking function of large-diameter water valves during operation without requiring specimen collection or manpower entering the inside of the valve were tested to assess the reliability of the technologies and their suitability for field application. The results showed that the condition of the graphite structure inside the valve body can be evaluated directly through the optical microscope in the field without specimen collection for large-diameter water butterfly valves, and the depth of corrosion inside the valve body can be determined by array ultrasound and the tensile strength can be measured by instrumented indentation test. The reliability of each of these non-destructive techniques is high, and they can be widely used to evaluate the condition of steel or cast iron pipes that are significantly smaller in thickness than valves. Evaluation of blocking function of the valves with mixed gas showed that it can be detected even when a very low flow rate of mixed gas passes through the disk along with the water flow. Finally, as a result of evaluating the field applicability of non-destructive technologies for three old butterfly valves installed in the US industrial water pipeline, it was found that it is possible to check the material and determine the suitability of large-diameter water valves without taking samples, and to determine the corrosion state and mechanical strength. In addition, it was possible to evaluate safety through the measurement results, and it is judged that the evaluation of the blocking function using mixed gas will help strengthen preventive response in the event of an accident.

방폭구조 ESD Detector 개발 및 본질안전 특성 분석에 관한 연구 (A Study on the Development of Explosion Proof ESD Detector and Intrinsic Safety Characteristics Analysis)

  • 변정환;최상원
    • 한국안전학회지
    • /
    • 제35권1호
    • /
    • pp.1-11
    • /
    • 2020
  • Article 325 (Prevention of Fire Explosion due to Electrostatic) of the Rule for Occupational Safety and Health Standard specifies that in order to prevent the risk of disasters caused by static electricity, fire, explosion and static electricity in the production process, However, in order to do this, it is absolutely necessary to use a pre-detection technology and a detector for antistatic discharge prediction, which is a precautionary measure by static electricity in a fire / explosion hazard place, but in Korea, And there is no technical standard for the application of the technology of the explosion proof structure of the related equipment. Research methods include domestic and overseas electrostatic discharge detection technology and literature investigation of related equipment explosion proofing technology, domestic and foreign electrostatic discharge detection device production and use situation investigation, advanced foreign technology data analysis and benchmarking. In particular, we sought to verify the results of empirical experiments using electrostatic discharge detection technology through sample purchase and analysis of related major products, development of optimization technology through prototype production, evaluation, and supplementation, and expert knowledge through expert consultation. The results of this study were developed and fabricated two prototypes of electrostatic discharge detector based on the technology / standard related to electrostatic discharge detection technology in Korea and abroad through development of electrostatic discharge detection technology and development and production of detector. In addition, based on the development of electrostatic discharge detection technology, we developed an intrinsic safety explosion proof ib class explosion proof technology applicable to the process of using and handling flammable gas and flammable liquid vapor and combustible dust. In the case of the over voltage and minimum voltage are supplied to the explosion-proof structure ESD detector, check the state of the circuit and the transient and transient currents generated by the coil and capacitor elements during the input and standby of the signal pulse voltage. Explosion-proof equipment-Part 11: Intrinsically safe explosion proof structure The comparative evaluation with the reference curve in Annex A of "i" confirms that the characteristics of the intrinsically safe explosion protection structure are met.

근로자의 안전을 위한 경보시스템 구현 (Implementation of the Alert System for Safety of Workers)

  • 김인민;고봉진
    • 한국항행학회논문지
    • /
    • 제15권6호
    • /
    • pp.1138-1142
    • /
    • 2011
  • 본 연구는 작업현장 내에서 일어날 수 있는 안전사고가 발생할 경우 이를 감지하여 빠른 조치를 취할 수 있도록 시스템을 구성하였다. 선행연구에서 구현된 시스템은 Star Topology방식의 무선 네트워크를 구성하였으나, 본 논문에서는 Peer-to-Peer Topology의 무선 네트워크를 구축하여 보다 효율적인 통신 네트워크를 구성할 수 있게 되었다. 또한 온도/가스센서와 기울기 센서를 이용한 2중 감지를 통해 작업자의 상황을 알리도록 하였으며, 빠른 판단과 신속한 조치를 할 수 있도록 모니터링 프로그램을 시각적 이미지화하여 사원의 개인 정보와 재난이 발생한 구역 등을 모니터링 하도록 설계하였다.

PC기반의 스마트 배터리 보호모듈 자동 검사 시스템 개발 (Development of PC-based Auto Inspection System for Smart Battery Protection Circuit Module)

  • 윤태성;장기원;박준호;이정재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.275-277
    • /
    • 2005
  • In a lithium-ion battery which is being used in many portable electronic goods, electrolyte is disaggregated and then the gas is happened when electric charging volt is over the 4.5V. So, the pressure on the safety valve is increased and electrolyte is leaked out in the cell. It leads to the risk of explosion. On the other hand, in the case which the battery is discharged excessively, the negative pole is damaged and the performance of the battery is deteriorated. The protection module of a lithium-ion battery is used for preventing such risk and the inspection system is needed to check the performance of such protection module. In this research, a PC-based auto inspection system is developed for the inspection of a battery protection module using Dallas chipset. In the inspection system, AVRl28 chip is used as a controller and the communication protocol is developed for the data communication between the protection module and the AVR128 chip. And GPIB interface is used for the control of measuring devices. Also, MMI environment is developed using LabView for convenient monitoring by the tester.

  • PDF

Type IV 고세장비 모듈형 수소저장용기의 충전 조건에서의 수치해석적 연구 (A Numerical Analysis Study on Charging Conditions of Type IV High Aspect Ratio Modular Hydrogen Storage Vessel)

  • 백중택;문지훈;민지훈;박균범;기광택;주성욱
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.26-31
    • /
    • 2023
  • In this study, in order to propose a modular method for type IV high aspect ratio modular hydrogen storage vessel, a numerical analysis was conducted on the heat transfer behavior in series and parallel connection methods, and the differences according to each connection method were reviewed. Computational fluid dynamics software was used to check the internal temperature and pressure values of the hydrogen storage container under charging conditions. In terms of thermal safety when charging hydrogen gas, it was confirmed that the parallel modularization method was superior.

일부 대체세정제 제조업체의 물질안전보건자료의 실태와 그 화학물질의 유해성 평가에 관한 연구 (Survey of Actual Conditions of Material Safety Data Sheet and Quantitative Risk Assessment of Toxic Substances : Substitutes for Degreasing Agents)

  • 윤종국;전태원;정진갑;이명희;이상일;차상은;유일재
    • 한국산업보건학회지
    • /
    • 제10권2호
    • /
    • pp.18-26
    • /
    • 2000
  • Since the regulation of MSDS (Material Safety Data Sheets) had started from July 1996, employers were required to furnish MSDS for the chemicals in use in their workplace. However, many MSDS did not contain upright information for the chemicals, and they were not updated regularly, and were not written in the standard format required by the Industrial Safety and Health Act (ISHA). The purposes of this study were 1) to examine the reliability of MSDS for mixed solvents, 2) to provide reliable MSDS to employers or employees, 3) to find out any difficulties in implementing MSDS after the initiation, and 4) to promote regular MSDS updating and to ensure the reliability of MSDS for chemical manufacturers. To check the reliability of MSDS of mixed chemicals, 21 samples of mostly degreasing solvents were collected along with their MSDS from the work place. The samples were analyzed by gas chromatography-mass selective detector(GC-MSD). Their components were classified as saturated hydrocarbon, cyclic hydrocarbon, aromatics, and halogen containing hydrocarbon, and the amount of each class were measured. Manufacture's MSDS were compared with the actual composition of the collected samples, and further examined the reliability by checking whether the chemicals analyzed were included in the MSDS correctly. Finally, each item of MSDS was evaluated whether the MSDS correspond to the regulation required by ISHA. The results were following: 1) most of the degreasing solvents in MSDS were incorrect in their composition and contents, 2) the information in the MSDS including hazard classification, exposure level, toxicity, regulatory information were incorrectly provided, and 3) some MSDS did not disclose carcinogens in their MSDS. Continuous monitoring of MSDS was required to ensure reliability of MSDS. The Chemicals containing hydrocarbons from C10-C15 need to be tested to provide toxicity data. In addition, governmental support for providing correct MSDS was recommended to ensure reliability of MSDS. The MSDS regulation relating to the confidential business information may need to be revised to ensure reliability of MSDS.

  • PDF