• Title/Summary/Keyword: Gas removal

Search Result 1,282, Processing Time 0.027 seconds

Improvement of the $SO_{x}$ Removal by Adding Dibasic Acids into the JBR FGD Process

  • Lee, Byeong-Kyu;Jeon, Sang-Ki;Cho, Seong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E4
    • /
    • pp.157-162
    • /
    • 2001
  • Jet Bubbling Reactors(JBRs) were operated for the removal of SO$_{x}$ in flue gases produced from many electric power plants. However, many JBR flue gas desulfurization (FGD) facility faced a decrease of SO$_{x}$ removal efficiency and an increase of scale problems with continuous operations. We increased alkalinity of the SO$_{2}$ absorbing medium by adding the dibasic acids (DBAs) to solve these problems more effectively. The SO$_{2}$ removal efficiency, the purity of CaCO$_{3}$ and COD of the wastewater was measured to identify the addition effects of DBAs (150, 200, 250, and 400 ppm) for 2hr in a day into the JBR attached to the large-scale power plants (400 MW$\times$3). Addition of the DBAs resulted in the improvement of the SO$_{2}$ removal efficiency from 2 to 5% and the purity of the gypsum from 1 to 2%; these improvement were due to the alkalinity increase of the absorbing medium and the reduction of a proportion of un-reacted CaCO$_{3}$, respectively. Also, the scale problems formed by un-reacted CaCO$_{3}$ inside the reaction zone of the JBR were substantially reduced. Even though the effluent COD of the wastewater slightly increased from 10~15 to 18~36 mg/l and the erosion problems in the injection pump and duct occurred, this method of increasing SO$_{2}$ removal efficiency by adding the DBAs could be considered as a profitable approach.ach.

  • PDF

Experimental investigation of aerosols removal efficiency through self-priming venturi scrubber

  • Ali, Suhail;Waheed, Khalid;Qureshi, Kamran;Irfan, Naseem;Ahmed, Masroor;Siddique, Waseem;Farooq, Amjad
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2230-2237
    • /
    • 2020
  • Self-priming venturi scrubber is one of the most effective devices used to collect aerosols and soluble gas pollutants from gaseous stream during severe accident in a nuclear power plant. The present study focuses on investigation of dust particle removal efficiency of the venturi scrubber both experimentally and theoretically. Venturi scrubber captures the dust particles in tiny water droplets flowing into it. Inertial impaction is the main mechanism of particles collection in venturi scrubber. The water injected into venturi throat is in the form of jets through multiple holes present at venturi throat. In this study, aerosols removal efficiency of self-priming venturi scrubber was experimentally measured for different operating conditions. Alumina (Al2O3) particles with 0.4-㎛ diameter and 3950 kg/㎥ density were treated as aerosols. Removal efficiency was calculated for different gas flow rates i.e. 3-6 ㎥/h and liquid flow rates i.e. 0.009-0.025 ㎥/h. Experimental results depict that aerosols removal efficiency increases with the increase in throat velocity and liquid head. While at lower air flow rate of 3 ㎥/h, removal efficiency decreases with the increase in liquid head. A theoretical model of venturi scrubber was also employed and experimental results were compared with mathematical model. Experimental results are found to be in good agreement with theoretical results.

Study on the Manufacture of Ethylene Gas Absorbing Corrugated Board (에틸렌 가스 흡착 기능성 골판지 제조를 위한 기초연구)

  • Lee, Ji Young;Kim, Chul Hwan;Kim, Eun Hea;Park, Tae Ung;Choi, Jae Sung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.2
    • /
    • pp.20-27
    • /
    • 2016
  • Ethylene gas is a natural hormone that directly affects the freshness of agricultural products, so it is very important for the maintenance of freshness to remove ethylene gas from corrugated board boxes. Many methods for the removal of this and other gases have been reported. In this study, the utilization of an absorbent using activated carbon was adopted for the removal of ethylene gas from a corrugated board box. Activated carbon powders were prepared by grinding in a laboratory and were used to treat the surface and to laminate paperboards with a starch solution. The ethylene gas absorption was evaluated by using a gas chromatography to measure the residual ethylene gas concentration. About 60% of the ethylene gas was absorbed by the activated carbon itself. However, the paperboards that were surface-treated and laminated with starch and activated carbon showed lower than 20% ethylene gas absorption. This was because the starch and smaller particles of activated carbon blocked the surface pores of activated carbon particles. Therefore, either the use of the binders must be minimized for the surface treatment of paperboards, or activated carbon packs can be used as absorbents in corrugated boxes.

Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor (PVDF 중공사막 제조 및 벤치규모 기-액 접촉기를 이용한 SO2 흡수특성)

  • Park, Hyun-Hee;Jo, Hang-Dae;Kim, In-Won;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.521-528
    • /
    • 2008
  • The micro-porous asymmetric PVDF hollow fiber membranes for gas-liquid contactor were prepared by the dry-jet wet phase inversion process and the characteristics of hollow fiber membranes were evaluated by the gas permeation method and scanning electron microscope. The chemical absorbent for removal of $SO_2$ gas was sodium hydroxide at bench scale hollow fiber membrane contactor. The experiments were performed in a counter-current mode of operation with gas in the shell side and liquid in the fiber lumen of the module to examine the effect of various operating variables such as concentration of absorbent, gas flow rate, L/G ratio and concentration of inlet $SO_2$ gas on the $SO_2$ removal efficiency using PVDF hollow fiber membrane contactor. Membrane mass transfer coefficient($k_m$) was calculated by mathematical modeling. The volumetric overall mass transfer coefficient increased with increasing the concentration of absorbent and L/G ratio. The increase of the absorbent concentration and L/G ratio not only provides more sufficient alkalinity but also decreases liquid phase resistance. The volumetric overall mass transfer coefficient increased with increasing gas flow rate due to decreasing the gas phase resistance.

Biofiltration of Air Streams Contaminated Hydrogen Sulfide : Performance Evaluation of Different Carriers

  • Jeong, Gwi-Taek;Lee, Gwang-Yeon;Lee, Kyoung-Min;Cha, Jin-Myoung;Joe, Yong-Il;Park, Don-Hee
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.456-462
    • /
    • 2005
  • The objective of this study was to develop a removal process by which $H_2S$ could be biologically removed from the odoriferous gases generated in the waste food recycling process. In order to develop this process we were first required to select a proper biofilter support protocol. When the selected biofilter equipment was then tested suing a synthetic odoriferous gas containing 600 ppm of $H_2S$, we noted a maximal removal rate of 658 $g-H_2S/m^3{\cdot}hr$, using polypropylene fibrils as supporting materials. Under identical experimental conditions, we obtained a value of 411.2 $g-H_2S/m^3{\cdot}hr$, using polyurethane as a support material. We also conducted a trial in which volcanic stone was utilized as a support material, and in this trial, we logged a maximal 105.1 $g-H_2S/m^3{\cdot}hr$ removal rate. As the result of our experiments, we concluded that polypropylene fibrils constituted the ideal material for the removal of $H_2S$ gas via biological treatment.

  • PDF

The effect of Pellet about $DeNO_x$ for Packed-bed type reactor (Packed-bed type 반응기에서 $NO_x$제거에 대한 Pellet의 영향)

  • Park, Jae-Yoon;Lee, Kyunh-Ho;Lee, Dong-Hoon;Kim, Jung-Dal;Park, Sang-Hyun;Koh, Hee-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.203-206
    • /
    • 2000
  • In this experiment, an attempt to use pellets($BaTiO_3$, $TiO_2$, ${\gamma}-Al_2O_3$, sludge) for $NO_x$ removal was conducted The effect of pellets on NO removal from simulated flue gas was experimentally investigated for packed-bed reactor of plate-plate geometry. An experimental investigation has been conducted for NO concentration of 50ppm balanced by air, and gas flow rate of $5{\ell}/min$. Ceramic pellets were used for surface discharge and the sludge pellets was added on $BaTiO_3$ and $TiO_2$ to increase $NO_x$ removal rate. In the result, $NO_x$ removal rate using $TiO_2$ was better than other pellets. $NO_2$ segnificatly generated by using $BaTiO_3$ pellets and sludge pellets used with $BaTiO_3$ decreased $NO_2$ generation.

  • PDF

Electron Donor Determination and Comparisons of Reaction Rates for Bioremediation of Nitrate Contaminated Groundwater (질산성 질소로 오염된 지하수의 생물복원을 위한 적정 전자공여체의 결정 및 반응속도 비교 연구)

  • Oa, Seongwook;Lee, Yoonhee;Kim, Geonha;Kim, Young
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.630-636
    • /
    • 2005
  • Groundwater contamination by nitrate exceeding water quality criteria (10 mg $NO_3{^-}-N/L$) occurs frequently. Fumarate, acetate, formate, lactate, propionate, ethanol, methane and hydrogen gas were evaluated for their nitrate removal efficiencies and removal rates for in situ bioremediation of nitrate contaminated groundwater. Denitrification rate for each substrate was in the order of: fumarate > hydrogen > formate/lactate > ethanol > propionate > methanol > acetate. Microcosm studies were performed with fumarate and acetate. When fumarate was used as a substrate, nitrate was removed 100 percent with rate of 0.66 mmol/day while conversion rate from nitrate to nitrogen gas or another by-product was 87 percent. 42 mg of fumarate was needed to remove 30 mg $NO_3{^-}-N/L$. When using acetate as carbon source, 31 percent of nitrate was removed during initial adjustment period. Among removed fraction, however, 83 percent of nitrate removed by cell growth. Overall nitrate removal rate was 0.37 mmol/day. Acetate showed longer lag time in consumption compared to that of nitrate, which implying that acetate would be better carbon source compared to fumarate as more amount was utilized for nitrate removal than cell growth.

Removal of Volatile Organic Compounds Using a Plasma Assisted Biotrickling System (플라즈마를 결합한 바이오 트리클링 시스템에 의한 휘발성 유기물질의 제거)

  • Kim, Hak-Joon;Han, Bang-Woo;Kim, Yong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.727-733
    • /
    • 2007
  • In this study, a newly developed biotrickling system, combined with a non-thermal plasma reactor, was investigated to effectively treat gaseous contaminants such as VOCs (Volatile Organic Compounds). Three kinds of non-thermal plasmas (NTPs) such as a rod type dielectric barrier discharge (DBD) plasma, a packed bead type DBD plasma and a gliding arc (GA) plasma, were tested and compared in terms of power consumption. The rod type DBD plasma was selected as one for integration with biotrickling system due to its relatively high VOC removal efficiency, low power consumption and low pressure drop. Toluene and xylene as representatives of VOCs were used as test gases. The experiment results showed that the efficiency of biotrickling system was especially very low at the high gas concentration and high flow rate and the removal efficiencies of VOCs were considerably enhanced in the biotrickling system, when the DBD plasma was worked in front of that even at the high gas concentration and high flow rate.

Effect of Magnetic Field on NOX Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOX 제거에 미치는 자계의 영향)

  • Park, Jae-Yun;Go, Hui-Seok;Son, Seong-Do;Lee, Dong-Hun;Kim, Jong-Dal
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.120-124
    • /
    • 2000
  • In this paper, the effect of magnetic field was measured on NOx(NO+NO2) removal and consumption power for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx of the simulated diesel engine flue gas were removed by the corona discharge generated by DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with discharge voltage. However, when magnetic field was applied to electric field vertically, consumption power slightly decreased. NOx removal rate and arc transition voltage for plasma reactor with magnetic field were higher than those for plasma reactor without magnetic field. Consumption power decreased, however NOx removal significantly increased, when water vapour bubbled by dry air was put into simulated flue gas.

  • PDF

Evaluation of Removal Efficiency of Water Contents using Inertial Impaction Separator (관성 충돌 방식의 액적 분리장치의 수분제거효율 평가)

  • Lee, Sin Young;Hong, Won Seok;Shin, Wanho;Kim, Gyujin;Song, Dong Keun
    • Particle and aerosol research
    • /
    • v.9 no.1
    • /
    • pp.23-29
    • /
    • 2013
  • Inertial impaction type mist eliminators are the most effective instruments to separate mist from the gas. In this work, the effect of the horizontal chevron type mist eliminators is characterized experimentally. Droplet size distribution and evaluation of removal efficiency of the chevron type mist eliminators at different gas flows were investigated using an aerosol particle size analyzer and a portable aerosol spectrometer, respectively. The experimental investigations showed that the mist removal efficiency in these instruments is dependent in the droplet size, and the pressure drop is nil.