• Title/Summary/Keyword: Gas purge

Search Result 93, Processing Time 0.018 seconds

Experimental Study on PSA Process for High Purity CH4 Recovery from Biogas (바이오가스로부터 고순도 CH4 회수를 위한 PSA 공정의 실험적 연구)

  • Kim, Young-Jun;Lee, Jong-Gyu;Lee, Jong-Yeon;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.281-286
    • /
    • 2011
  • The objective of this study is to optimize the four-bed six-step pressure swing adsorption(PSA) process for high purity $CH_4$ recovery from the biogas. The effects of P/F(purge to feed) ratio and cycle time on the process performance were evaluated. The cyclic steady-states of PSA process were reached after 12 cycles. The purity and recovery rate of product gas, pressure and temperature changes were constant as the cycle repeated. It was shown that the P/F ratio gave significant effect on the product recovery rate by increasing the amount of purge gas in purge and regeneration step. The optimal P/F ratio was found to be 0.08. As the cycle time increased, the product purity decreased by increasing the feed gas flow rate. It was found that the optimal operating conditions were P/F ratio of 0.08 and total cycle time of 1,440 seconds with the purity of 97%.

Comparison Solid Phase Microextraction with Purge & Trap on the GC/MS Analysis of Volatile Organic Compounds in Biota Samples (Solid Phase Microextraction 및 Purge & Trap을 이용한 생물시료 중 휘발성 유기화합물의 GC/MS 분석비교)

  • Ahn, Yun-Gyong;Seo, Jong-Bok;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.392-399
    • /
    • 2001
  • The analysis of n-butylbenzene and 1,2-dibromo-3-chloropropane (DBCP) as volatile organic compounds in biota samples was performed by gas chromatography/mass spectrometry-selected ion monitoring mode. The target compounds, n-butylbenzene and DBCP, in biota samples were extracted by headspace solid phase microextraction (SPME) with $100{\mu}m$ polydimethyl siloxane (PDMS) fiber and purge & trap method. The extraction recoveries of these compounds obtained by SPME was 85.8% for n-butylbenzene and 92.4% for DBCP, respectively. Each value of method detection limit were $0.15{\mu}g/kg$ and $0.05{\mu}g/kg$, respectively. While in the case of purge & trap method, the extraction recovery was 115.2% for n-butylbenzene, 80.9% for DBCP and method detection limit were $0.04{\mu}g/kg$ and $0.70{\mu}g/kg$, respectively. The extraction yields and detection limits of these compounds obtained by purge & trap were equivalent to those by SPME.

  • PDF

Review on the Process Safety of $SiH_{4}$ Gas used in Semiconductor and FPD Field (반도체 및 FPD 분야에 사용되는 $SiH_{4}$ 가스의 공정 안전 고찰)

  • Kim, Joung-Cho;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.32-36
    • /
    • 2007
  • When the vacuum system for the process of $SiH_{4}$ gas used in the semiconductor and FPD field is partially vented from vacuum to atmospheric state, a fire often occurs due to auto-ignition of $SiH_{4}$ gas. In order to prevent the fire, the concentration of $SiH_{4}$ should be kept under LFL. This means that the higher capacity pump is needed to meet the process conditions as well as the condition that the concentration of $SiH_{4}$ should be kept under LFL. In this article, we conducted the injection of the dilution gas at the manifold between booster pump and dry pump compared with the typical method that the dilution gas was injected into inlet port of booster pump using computer simulation. According to the result, we can flow further more purge gas for safety without any change of the condition in the process chamber, which means that the higher capacity pump is not required for safety in some cases.

Development of the Integrated Exhaust System and Techniques of Nitrogen and Condensate for Fuel Cell Electric Vehicle (연료전지 자동차용 질소/응축수 통합배출시스템 및 기술 개발)

  • Shim, Hyo Sub;Kim, Hyo Sub;Kim, Jae Hoon;Kwon, Bu Kil;Lee, Hyun Joon;Kim, Chi Myung;Park, Yong Sun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.516-524
    • /
    • 2014
  • Proper discharge of nitrogen gas and water condensate is required in a conventional fuel cell system for performance, stability and durability of fuel cell stacks. Present study covers the development of integrated unit and its functioning logic for simultaneous nitrogen gas purge and water condensate drainage in a fuel cell vehicle system. Configuration of condensate drainage pipe, purge valve and level sensor is considered and optimized in physical integration. As a key factor, discharge time is considered and optimized based on the test result of constant-current operation with various operating temperature in logic development. Consequently, derived optimal values are applied and verified in actual vehicle drive mode test. Increase of system design flexibility, weight reduction and cost reduction are anticipated with this study. Additional study for physical and logical improvement is currently being implemented.

Comparison between Head Space Gas Sampling and Purge & Trap Sampling in Water Analysis

  • Nagayanagi, Yutaka;Nakagawa, Katsuhiro;Saito, Yoshihiro;Kim, Poongzag
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.739-744
    • /
    • 1995
  • The two main methods to prepare water samples for analyzing volatile organic compounds(VOC's) were investigated. One is the purge and trap(PT) method and another is the head space(HS) sampling method. Both methods were effective to transfer the low boiling point components from the water sample onto the capillary column. The cryo-focusing at the top of the main capillary column was an effective way to obtain the sharpness of the chromatographic peaks but could be avoided when a semi-wide bore column was used. The recovery from the same amount of the sample was better in PT than in HS but a larger sample volume in HS method could compensate the lower efficiency. Therefore PT is suitable to the analysis of drinking water where the very low concentration must be determined. HS is suitable to waste water analysis because of the easiness of the operation. The repeatability was good and similar in both methods. For the contamination of the former sample, both methods were tough and could be used without any problems. The matrix effect which could change the equilibrium parameters in HS method was find negligible in many components. The actual samples such as tap water and river water were analyzed with both methods concerning 16 components regulated in Korea.

  • PDF

Performance Enhancement and Recovery Method of Open Cathode PEMFC (오픈 캐소드형 고분자전해질 연료전지의 성능향상과 회복기법)

  • Lee, Kitaek;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.28 no.1
    • /
    • pp.118-124
    • /
    • 2017
  • An air cooling, open cathode type polymer electrolyte membrane fuel cell (PEMFC) has the advantages of system simplification and cost effectiveness. Open cathode PEMFC could suffer from reduced performance due to the membrane dehydration in low humidity of air. Effects of the cathode air flow rate, anode purge interval and long term storage on PEMFC performance were investigated in this work. Fan voltage is an important factor on air cooling PEMFC performance because the cathode air flow rate and stack temperature were controlled by fan voltage. The dead ended anode (DEA) method was applied to increase hydrogen usage. Periodical purge was used to discharge accumulated water and gas. The influence of long term non-operating condition on PEMFC performance degradation due to the membrane dehydration was also studied and the quick recovery method was developed.

MEMBRANE-BASED GAS AND VAPOR SEPARATIONS

  • Wijmans, Hans
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.3-6
    • /
    • 2004
  • Industrial gas separation by membranes began in 1980 with the introduction of hollow-fiber polysulfone membrane systems by Permea, at that time a division of Monsanto. This first application was the recovery of hydrogen from ammonia reactor purge gas and was soon followed by the generation of nitrogen from air. Today, membrane gas separation ranks second behind cryogenic distillation in terms of nitrogen production, and this application has drawn the industrial gas companies into the membrane field.(omitted)

  • PDF

Characterization of $CO_2$ Separation in Landfill Gas by Using Adsorbent (흡착제를 이용한 매립지가스 내 $CO_2$ 분리 특성)

  • Heo, Rye-Hwa;Yoo, Young-Don;Kim, Mun-Hyun;Kim, Hyung-Taek;Choi, Ik-Hwan
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.46-51
    • /
    • 2009
  • The purpose of this study is to investigate selective adsorption of $CO_2$ from LFG (Landfill gas) by using commercialized NaX-type zeolite adsorbent under the ambient temperature and pressure. The experiment of $CO_2$ adsorption was carried out by using simulated LFG. The $CO_2$ adsorption capacity and separation efficiency of NaX-type adsorbent were investigated by analyzing gas flow rate and gas composition at inlet and outlet of the adsorption reactor. The adsorbed $CO_2$ were desorbed under decompression condition which 0.5 Torr or by air purge. Through the result to use simulated LFG, when the method of VSA was used, 73.2~75.3 mg of $CO_2$ was adsorbed per 1 g commercial adsorbent, when the method of air purge was used, 78.4~83.2 mg of $CO_2$ was adsorbed per 1 g of commercial adsorbent.

  • PDF

Novel Polypyrrole composite membrane with high gas selectivity and permeability

  • Son, Won-Il;Kim, Byoung-Sik;Hong, Jae-Min
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.147-152
    • /
    • 2004
  • Gas separation membrane technology is useful for a variety of applications [1, 2]. such as hydrogen recovery from reactor purge gas, nitrogen and oxygen enrichment, water vapor removal from air, stripping of carbon dioxide from natural gas. etc. Although membrane separations are attractive because of low energy costs and simple operation, low permeabilities and/or selectivity often limit membrane applications [3, 4].(omitted)

  • PDF

A Study on the Welds Characteristics of Stainless Steel 316L Pipe using Orbital Welding Process (오비탈 용접법을 적용한 STS 316L 파이프 소재의 용접부 특성에 관한 연구)

  • Lee, B.W.;Joe, S.M.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.71-77
    • /
    • 2010
  • This paper was studied on microstructure, mechanical properties and corrosion characteristics of 316L stainless steel pipe welds was fabricated by orbital welding process. S-Ar specimen was fabricated by using Ar purge gas and S-$N_2$ specimen was fabricated by using $N_2$ purge gas. Ferrite was not detected in weld metal of S-$N_2$ specimen but the order of 0.13 Ferrite number(FN) was detected in weld metal of S-Ar specimen. Oxygen and Nitrogen concentration of S-$N_2$ specimen was higher than S-Ar specimen on HAZ and inner bead. The welds microstructural characteristics of S-Ar and S-$N_2$ specimens are similar. The microvickers hardness values of S-Ar and S-$N_2$ specimens welds were similar and average values of each regions were in the range of 174~194. The microstructures of S-Ar and S-$N_2$ weld metal were full austenite by primary austenite solidification. The Solidification structures of S-Ar and S-$N_2$ weld metal were formed directional dendrite toward bead center. The potentiodynamic polarization curve of STS 316L pipe welds exhibited typical active, passive, transpassive behaviour. Corrosion current density$(I_{corr.})$ and corrosion rate values of S-Ar specimen in 0.1M HCl solution were $0.95{\mu}A/cm^2$ and $0.31{\mu}A$/year respectively. The values of S-$N_2$ specimen were $1.4{\mu}A/cm^2$ and $0.45{\mu}m$/year.