• 제목/요약/키워드: Gas lines

검색결과 393건 처리시간 0.027초

Spitzer IRS mapping of L1251B

  • 이정은
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.58.2-58.2
    • /
    • 2010
  • L1251B, which was revealed as a small group of protostars by the Spitzer Space Telescope (SST), presents a great site of studying chemical evolution in gas and ice as well as various dynamical processes associated with star formation (infall, rotation, and outflow). We have mapped L1251B with the Infrared Spectrograph (IRS) aboard the SST to study the chemical distribution in the phases of gas and ice and the dynamical feature related to shock in the region. Various atomic lines and the $H_2$ pure rotational lines, which trace different shock velocities, were detected. In addition, the distribution of the water and $CO_2$ ices hints variety of the ice desorption mechanism in L1251B.

  • PDF

보호철판을 이용한 가스배관 유도전압대책에 관한 연구 (A Study on the Existing Induced Voltage Mitigation Method on Gas Pipelines using Steel Plate)

  • 하태현;이현구;배정효;김대경;이성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.354-356
    • /
    • 2001
  • The demand of the power and gas energy have been rapidly increasing with the industralization, therefore, the area where buried pipelines run parallel with the adjacent power lines and cross them increases in Seoul as well as other cities. These situation cause AC interference from the power lines. However, there aren't any standards to preserve the pipelines from AC interference in Korea. We just use other country's criteria directly. Other developed countries have used the various AC interference mitigation methods such as lumped grounding. cancellation wires and gradient control wires etc.. This paper introduces the steel plate method which is using for AC interference mitigation method in Korea and investigates the effects of mitigation methods through case study by computer simulation.

  • PDF

INFRARED [FE II] EMISSION LINES FROM RADIATIVE ATOMIC SHOCKS

  • KOO, BON-CHUL;RAYMOND, JOHN C.;KIM, HYUN-JEONG
    • 천문학회지
    • /
    • 제49권3호
    • /
    • pp.109-122
    • /
    • 2016
  • [Fe II] emission lines are prominent in the infrared (IR) and important as diagnostic tools for radiative atomic shocks. We investigate the emission characteristics of [Fe II] lines using a shock code developed by Raymond (1979) with updated atomic parameters. We first review general characteristics of the IR [Fe II] emission lines from shocked gas, and derive their fluxes as a function of shock speed and ambient density. We have compiled available IR [Fe II] line observations of interstellar shocks and compare them to the ratios predicted from our model. The sample includes both young and old supernova remnants in the Galaxy and the Large Magellanic Cloud and several Herbig-Haro objects. We find that the observed ratios of the IR [Fe II] lines generally fall on our grid of shock models, but the ratios of some mid-IR lines, e.g., [Fe II] 35.35 µm/[Fe II] 25.99 µm, [Fe II] 5.340 µm/[Fe II] 25.99 µm, and [Fe II] 5.340 µm/[Fe II] 17.94 µm, are significantly offset from our model grid. We discuss possible explanations and conclude that while uncertainties in the shock modeling and the observations certainly exist, the uncertainty in atomic rates appears to be the major source of discrepancy.

HCO+ Observations toward Compact Radio Continuum Sources Using the KVN 21-m Telescopes to Trace Dark Molecular Gas

  • Park, Geumsook;Koo, Bon-Chul;Kim, Kee-Tae;Byun, Do-Young;Heiles, Carl
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.52.3-53
    • /
    • 2015
  • It has been known that there is "dark gas" invisible either in 21-cm HI or 2.6-mm CO emission which are general tracers of atomic and molecular gas, respectively. Many researchers consider that the dark gas is "Dark Molecular Gas (DMG)" composed of CO-free $H_2$ in the intermediate zone between atomic and full-fledged molecular gas and that HCO+ and OH molecules are good tracers of the DMG since they can form in much lower $H_2$ column densities where CO does not. We have carried out HCO+ J=1-0 absorption observations toward nine bright extragalactic radio continuum sources using the KVN 21-m telescopes as single dishes. We detected HCO+ absorption lines toward two sources. We derive HCO+ and $H_2$ column densities or their limits, and discuss the implications of our results.

  • PDF

What Determines Star Formation Rates?

  • Evans, Neal
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.29.4-29.4
    • /
    • 2016
  • The relations between star formation and properties of molecular clouds are studied based on a sample of star forming regions in the Galactic Plane. Sources were selected by having radio recombination lines to provide identification of associated molecular clouds and dense clumps. Radio continuum and mid-infrared emission were used to determine star formation rates, while 13CO and submillimeter dust continuum emission were used to obtain masses of molecular and dense gas, respectively. We test whether total molecular gas or dense gas provides the best predictor of star formation rate. We also test two specific theoretical models, one relying on the molecular mass divided by the free-fall time, the other using the free-fall time divided by the crossing time. Neither is supported by the data. The data are also compared to those from nearby star forming regions and extragalactic data. The star formation "efficiency," defined as star formation rate divided by mass, spreads over a large range when the mass refers to molecular gas; the standard deviation of the log of the efficiency decreases by a factor of three when the mass of relatively dense molecular gas is used rather than the mass of all the molecular gas.

  • PDF

병렬 운전되는 대형 왕복동 압축기의 가스맥동 분석 (Gas pulsation analysis of large reciprocating compressor in parallel operation)

  • 김성준;김현철;김현진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.910-915
    • /
    • 2009
  • For large reciprocating compressors in parallel operation, an analytical study has been carried out on the gas pulsation in associated discharge piping lines. Since the pressure pulsation at a valve, valve dynamics, and the gas flow rate through the valve are interrelated, affecting one another, these need to be solved simultaneously. Acoustic transfer matrix method, which relates acoustic pressure and velocity at one location to those at another location, has been adopted to calculate the effect of the gas flow at one valve location on the gas pulsation at other valve locations.

  • PDF

Revealing ionized gas kinematics at the center of nearby Seyfert galaxies

  • Kim, Eun Chong;Woo, Jong-Hak
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.43.2-43.2
    • /
    • 2014
  • We investigate the ionized gas kinematics at the center of 6 nearby Seyfert galaxies, using the integral field spectroscopy data from the Calar Alto Legacy Integral Field spectroscopy Area survey Data Release 1. To understand the kinematic nature of the ionized gas in the narrow-line regions (NLRs), we measured the flux, velocity, and velocity dispersion of the [OIII] $5007{\AA}$ and Ha $6563{\AA}$ emission lines, after subtracting a best-fit stellar population model representing the stellar features. At the same time, we measured stellar velocity as a reference for the systemic velocity, and stellar velocity dispersion. We spatially resolved the velocity structure of the ionized gas using each emission line and compared it to that of stars. In this poster we present the flux, velocity, and velocity dispersion maps of the ionized gas and stars, and discuss the nature of the ionized gas outflows in the central kiloparsec scale.

  • PDF

병렬 운전되는 대형 왕복동 압축기의 가스맥동 분석 (Gas Pulsation Analysis of Large Reciprocating Compressors in Parallel Operation)

  • 김성준;김현재;김현진
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.97-103
    • /
    • 2010
  • For large reciprocating compressors in parallel operation, an analytical study has been carried out on the gas pulsation in associated discharge piping lines. Since the pressure pulsation at a valve, valve dynamics, and the gas flow rate through the valve are interrelated, affecting one another, these need to be solved simultaneously. Acoustic transfer matrix method, which relates acoustic pressure and velocity at one location to those at another location, has been adopted to calculate the effect of the gas flow at one valve location on the gas pulsation at other valve locations.

철도차량에 의한 배기가스 배출량 예측에 관한 기초연구 (A Basic Study on the Estimation of Exhaust Emission Rates by Railroad Vehicles)

  • 박덕신;정우성;정병철;김태오
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.392-397
    • /
    • 2001
  • As the air pollution caused by diesel vehicles goes worse, so non-road vehicles exhaust gas standard is strict in an foreign countries. In this paper, we calculate the amount of emission rates from Korean railroad lines and train kinds. Air pollutants emissions are calculated using by US EPA baseline in-use emission rates which is divided line-haul and switch mode. The calculated HC emissions on the railroad diesel vehicles are 1,209.1 t from Korean railroad lines.

  • PDF

정밀기기의 낙뢰서지 대책에 관한 연구 (Protecting electronic equipment against lightning surge)

  • 임순재;이주광;이완규;최만용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.358-362
    • /
    • 1995
  • Precision electronic equipments are composed of sophisticated microcircuits that are extremely vulnerable to lightning-caused voltage spike. This transient voltage spike may cause upset, latent failure or interference on electronic equipments. In order to develop efficient lightning protection measures on AC power lines for a road traffic controller, experimental surge immunity tests were conducted according to IEC standard 801-5. The combination of gas tube arrester and metal-oxide varistor was installed at the input of AC power lines and the silicon avalanche suppressor installed at the output of DC power supply as lightning protection measures.

  • PDF