• 제목/요약/키워드: Gas chromatography-mass spectrometry (GC/MS)

검색결과 662건 처리시간 0.024초

한국산(韓國産) Horseradish 뿌리의 휘발성 풍미 성분 (Volatile Compounds Characterizing the Flavor of Korean Horseradish Roots)

  • 김인숙;이미순
    • Journal of Nutrition and Health
    • /
    • 제18권4호
    • /
    • pp.293-300
    • /
    • 1985
  • Volatile components of Korean horseradish roots harvested at different dates were prepared by steam distillation. Samples were examined by gas chromatography (GC) and combined gas chromatography-mass spectrometry (GC-MS). The major pungent constituent, allyl isothiocyanate was confirmed add tended to increase with delayed harvest time. Pungent principles also included allyl thiocyanate, 2-phenethyl, 2-butyl, 4- pentenyl, benzyl and 3-methylthiopropyl isothiocyanates. Infrared (IR) spectroscopy study showed that allyl isothiocyanate - thiocyanate interconversion did not occur under the condition of this study.

  • PDF

참쑥(Artemisia Lavandulaefolia DC)의 방향성분 (Flavor Components of Artemisia Lavandulaefolia DC)

  • 최경숙;최봉영;박형국;김정한;박종세;윤창노
    • 한국식품과학회지
    • /
    • 제20권6호
    • /
    • pp.774-779
    • /
    • 1988
  • 참쑥(Artemisia lavandulaefolia DC)의 정유를 gas chromatogaphy/mass spectrometry(GC/MS)로 정성분석하고, 저장조건을 달리하여 정유성분의 변화를 살펴본 결과, 다음과 같은 결론을 얻었다. 1. 186 이상의 화합물이 검출되었으며, 그 중 1,8-cineol, camphor, ${\beta}-thujone$, caryophyllene, borneol, coumarin, linalool, terpineol, sabinene, 7-methoxy coumarin ${\alpha}-copaene$, humulene과phytol이 중요성분이었다. Artemisia species에서는 지금까지 밝혀진 바 없는 3,6,6-trimethyl norpinanol, ${\beta}-farnesene$, 7-methoxy coumarin, ${\alpha}-curcumene$ 등이 검출되었다. 2. 참쑥의 저장에 따른 색과 변화를 조사한 결과, 온도에 의해 갈색화와 성분의 증감이 있었다. 즉, 냉암소에 보관된 시료는 변화가 거의 없었으나, 상온방치한 시료는 Air와 질소에 상관없이 모두 변화가 있었다. 1,8-cineol, limonene, 2,2,4-trimethyl 1,3-dioxolane-4-ethanol, terpinene-4-ol 등은 감소하였으며, ${\beta}-phellandrene$, benzyl benzoate, broneol, ${\alpha}-terpineol$, humulene 등은 증가하였다.

  • PDF

Determination of 11 Phenolic Endocrine Disruptors using Gas Chromatography/Mass Spectrometry-Selected Ion Monitoring in Five Selected Wastewater Influents

  • Kim, Hyub
    • Environmental Engineering Research
    • /
    • 제13권4호
    • /
    • pp.216-223
    • /
    • 2008
  • An efficient method for the simultaneous determination of eleven phenolic endocrine-disrupting chemicals (EDCs) present in wastewater influent samples was described. The 11 phenolic EDCs including alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) following two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. The wastewater influent samples containing the 11 EDCs were adjusted to pH 2 with $H_2SO_4$ and then cleaned up with n-hexane. Next, they were subjected to solid-phase extraction (SPE) with XAD-4 resin and subsequently converted to isoBOC or TBDMS derivatives for sensitivity analysis with gas chromatography/mass spectrometry-selected ion monitoring (GC/MSSIM). Following isoBOC derivatization and TBDMS derivatization, the recoveries were 86.6-105.2% and 97.6-142.7%, the limits of quantitation (LOQ) for the 11 phenolic EDCs for SIM was 0.001-0.050 ng/mL and 0.003-0.050 ng/mL, and the SIM responses were linear with the correlation coefficient varying by 0.9717-0.9995 and 0.9842-0.9980, respectively. When these methods were applied to five selected wastewater influent samples, for isoBOC derivatization and TBDMS derivatization the ranges of concentration detected were 0.2-99.6 ng/mL and 0.4-147.4 ng/mL, respectively.

Organic Acid Profiling Analysis in Culture Media of Lactic Acid Bacteria by Gas Chromatography-Mass Spectrometry

  • Lee, Jae-Yeon;Nguyen, Duc-Toan;Park, Young-Shik;Hwang, Kyo-Yeol;Cho, Yong-Seok;Kang, Kyung-Don;Yoon, Jae-Hwan;Yu, Jun-Dong;Yee, Sung-Tae;Ahn, Young-Hwan;Lee, Gwang;Seong, Su-Il;Paik, Man-Jeong
    • Mass Spectrometry Letters
    • /
    • 제3권3호
    • /
    • pp.74-77
    • /
    • 2012
  • Organic acid (OA) profiling analysis was performed in culture media from Lactobacillus pentosus K34 (L. pentosus K34) and Pediococcus lolli PL24 (P. lolli PL24) by gas chromatography-mass spectrometry (GC-MS) following methoxime/tert-butyldimethylsilyl derivatives. 12 OAs were positively identified in culture media. Most of OA levels from L. pentosus K34 of hetero lactic fermentation were found to be higher when compared with those from P. lolli PL24 of homo lactic fermentation, which may explain different OA metabolism in each strain. In addition, the distorted dodecagonal star patterns were readily distinguishable, and the characteristics of each strain were well represented. The present study demonstrates that the OA metabolic profiling method by GC-MS combined with star pattern recognition is useful for the monitoring study of characteristic OA metabolism in various microorganisms.

단기숙성치즈 및 EMC 치즈의 휘발성 풍미성분 신속분석방법으로서 Pyrolysis/GC-Mass Spectrometry의 이용 (Pyrolysis/GC-Mass Spectrometry Analysis for Rapid Identification of Volatile Flavour Compounds of Accelerated Ripened Cheddar Cheese and Enzyme-Modified Cheese)

  • 박승용;허강칠;신중엽
    • 한국축산식품학회지
    • /
    • 제21권3호
    • /
    • pp.256-264
    • /
    • 2001
  • Pyrolysis/GC-mass spectrometry(Hewlet-Packard 5890GC/mass selective detector, 5971 BMSD), interfaced to a CDS Pyroprobe 1500 was optimized for rapid analysis of flavour compounds in Cheddar cheese. Twenty flavour compounds, including aldehydes(4), ketones(4), fatty acids(10), alcohol(1), and hydrocarbon(1), were identified from Cheddar cheeses. In total, Twenty-three flavour compounds aldehydes(2), ketones(8), alcohols(3), fatty acids(7), lactone(1), benzene derivative(1) and amide(1) were identified from two samples of accelerated-ripened Cheddar cheese treated with the proteolytic enzymes of Lactobacillus casei LGY. In total, Twenty-one flavour compounds; aldehydes(2), ketones(5), alcohols(2), fatty acids(11), and lactone(1) were identified from enzyme-modified cheese(EMC) treated with the combination of the proteolytic enzymes of Lactobacillus casei LGY and commercial endopeptidase or lipase. However, All the flavour compounds identified by pyrolysis/GC/MS in samples of ARC and EMC were not determined whether they are recognized as typical Cheddar flavour or not. More studies were requested on the development of methods for a rapid and convienent analysis of dairy fermented products using pyrolysis/GC-mass spectrometry.

  • PDF

Trifluralin in aquatic products: QuEChERS and Gas chromatography-tandem mass spectrometry for trace amount detection

  • Le-Thi Anh-Dao;Do Minh-Huy;Vo Hong-Phong;Nguyen Cong-Hau
    • 분석과학
    • /
    • 제36권5호
    • /
    • pp.205-215
    • /
    • 2023
  • In the present study, an analytical method was proposed for detecting trifluralin in aquatic products at trace concentrations. The method employed QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) and gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) as the sample preparation and measurement, respectively. The effect of the aqueous phase volume used in the QuEChERS was demonstrated, and the ratio of 10:10 (mL) between water and acetonitrile phase was used for 5 g of sample. Besides, dSPE using C18 and primary-secondary amine (PSA) was applied to remove the potential interferences from the food matrices, indicating no remarkable analyte loss. The linear range was built up from 0.50 ㎍ L-1 to 3.0 ㎍ L-1 (R2 = 0.9993). Other criteria, i.e., repeatability (RSDr = 0.86-1.96 %), reproducibility (RSDR = 1.09-2.01 %), and recovery (over 90 %), were in accordance with Appendix F of AOAC (2016) for method performance. Although no trifluralin was detected for the commercial samples (fish, shrimp, and breaded shrimp), the spiked samples performed favorable recoveries and precision.

Determination of Persistent Organochlorine Pollutants in Rat Hair by Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang;Pyo, Hee-Soo;Park, Song-Ja
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권10호
    • /
    • pp.1489-1494
    • /
    • 2004
  • A gas chromatography/mass spectrometric assay method was developed for the determination of persistent organochlorine pollutants (POPs) in hair. For the exact extraction study was used hair of rat exposed with POPs. Sonication of the hair matrix with 3 M HCl solution in methylene chloride of the extraction methods studied was the most efficient and rapid sample preparation method. After sonication of rat hair was achieved clean up with a solid phase extraction procedure using silica gel-florisil. Elution was performed with 8 mL of methylene chloride. The eluate was concentrated to approximately 100 ${\mu}L$ and analyzed by gas chromatography-mass spectrometry (GC-MS). Detection limits of POPs were in the concentration range of 0.6-1.2 ng/g in rat hair. Aldrin, dieldrin, p,p-DDT and mirex were dosed rat for 4 weeks at concentration of 0.01 mg/L in drinking water and detected in rat hair at concentration of 2.8, 11.3, 7.9 and 15.6 ng/g, respectively. Aldrin and p,p-DDT were metabolized to dieldrin and p,p-DDE, which were detected in concentration of 9.7 and 2.9 ng/g in rat hair, respectively. The developed method may be valuable to be used to analyze POPs in human hair.

Validation of an analytical method for cyanide determination in blood, urine, lung, and skin tissues of rats using gas chromatography mass spectrometry (GC-MS)

  • Shin, Min-Chul;Kwon, Young Sang;Kim, Jong-Hwan;Hwang, Kyunghwa;Seo, Jong-Su
    • 분석과학
    • /
    • 제32권3호
    • /
    • pp.88-95
    • /
    • 2019
  • This study was conducted to establish the analytical method for the determination of cyanide in blood, urine, lung and skin tissues in rats. In order to detect or quantify the sodium cyanide in above biological matrixes, it was derivatized to Pentafluorobenzyl cyanide (PFB-CN) using pentafluorobenzyl bromide (PFB-Br) and then reaction substance was analyzed using gas chromatography mass spectrometer (GC/MS)-SIM (selected ion monitoring) mode. The analytical method for cyanide determination was validated with respect to parameters such as selectivity, system suitability, linearity, accuracy and precision. No interference peak was observed for the determination of cyanide in blank samples, zero samples and lower limit of quantification (LLOQ) samples. The lowest limit detection (LOD) for cyanide was $10{\mu}M$. The linear dynamic range was from 10 to $200{\mu}M$ for cyanide with correlation coefficients higher than 0.99. For quality control samples at four different concentrations including LLOQ that were analyzed in quintuplicate, on six separate occasions, the accuracy and precision range from -14.1 % to 14.5% and 2.7 % to 18.3 %, respectively. The GC/MS-based method of analysis established in this study could be applied to the toxicokinetic study of cyanide on biological matrix substrates such as blood, urine, lung and skin tissues.

교반막대 추출법과 GC/MS-MS를 이용한 수중의 자외선 차단제 분석 (Analysis of UV Filters in Water using Stir Bar Sorptive Extraction (SBSE) and GC/MS-MS)

  • 서창동;손희종;정종문;최진택;장성호
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1037-1047
    • /
    • 2014
  • A highly sensitive analytical method based on stir bar sorptive extraction (SBSE) technique and gas chromatography/tandem mass spectrometry (GC/MS-MS) has been developed, allowing the simultaneous multi-analyte determination of seven UV filters in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 40 mL of water sample at pH 3 and stirred at 1,100 rpm for 120 min. Other SBSE parameters (salt effect and presence of organic solvent) were optimised. The method shows good linearity (coefficients > 0.990) and reproducibility (RSD < 12.9%). The extraction efficiencies were above 84% for all the compounds. The limits of detections (LOD) and limits of quantification (LOQ) were 2.1~8.6 ng/L and 6.8~27.5 ng/L, respectively. The developed method offers the ability to detect 8 UV filters at ultra-low concentration levels with only 40 mL of sample volume. Matrix effects in tap water, river water, wastewater treatment plant (WWTP) final effluent water and seawater were investigated and it was shown that the method is suitable for the analysis of trace level of 7 UV filters except of benzophenone (BP). The method developed in the present study has the advantage of being rapid, simple, high-sensitive and both user and environmentally friendly.