• Title/Summary/Keyword: Gas channel

Search Result 471, Processing Time 0.023 seconds

Heat/Mass Transfer on Effusion Plate with Circular Pin Fins for Impingement/Effusion Cooling System with Intial Crossflow (초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 원형핀이 설치된 유출면에서의 열/물질전달 특성)

  • Hong Sung Kook;Rhee Dong-Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.828-836
    • /
    • 2005
  • Impingement/effusion cooling technique is used for combustor liner or turbine parts cooling in gas turbine engine. In the impingement/effusion cooling system, the crossflow generated in the cooling channel induces an adverse effect on the cooling performance, which consequently affects the durability of the cooling system. In the present study, to reduce the adverse effect of the crossflow and improve the cooling performance, circular pin fins are installed in impingement/effusion cooling system and the heat transfer characteristics are investigated. The pin fins are installed between two perforated plates and the crossflow passes between these two plates. A blowing ratio is changed from 0.5 to 1.5 for the fixed jet Reynolds number of 10,000 and five circular pin fin arrangements are considered in this study. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The results show that local distributions of heat/mass transfer coefficient are changed due to the installation of pin fins. Due to the generation of vortex and wake by the pin fin, locally low heat/mass transfer regions are reduced. Moreover, the pin fin prevents the wall jet from being swept away, resulting in the increase of heat/mass transfer. When the pin fin is installed in front of the impinging let, the blockage effect on the crossflow enhances the heat/mass transfer. However, the pin fin installed just behind the impinging jet blocks up the wall jet, decreasing the heat/mass transfer. As the blowing ratio increases, the pin fins lead to the higher Sh value compared to the case without pin fins, inducing $16\%{\~}22\%$ enhancement of overall Sh value at high blowing ratio of M=1.5.

Modeling and Performance Analysis of SCR $DeNO_X$ Catalyst for Reducing $NO_X$ Emissions in Diesel Engine (디젤엔진의 $NO_X$ 저감을 위한 SCR $DeNO_X$ 촉매의 모델링 및 성능해석)

  • Kim, Young-Deuk;Kim, Woo-Seung;Lee, Chun-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.137-145
    • /
    • 2009
  • The steady-state kinetics of the selective catalytic reduction (SCR) of $NO_X$ with $NH_3$ has been investigated over a commercial ${V_2}{O_5}/TiO_2$ catalyst. In order to account for the influence of transport effects the kinetics are coupled with a fully transient two-phase 1D+1D monolith channel model. The Langmuir-Hinshelwood (L-H) mechanism is adopted to describe the steady-state kinetic behavior of the ${V_2}{O_5}/TiO_2$ catalyst. The reaction rate expressions are based on previously reported papers and are modified to fit the experimental data. The steady-state chemical reaction scheme used in the present mathematical model has been validated extensively with experimental data of selective $NO_X$ reduction efficiency for a wide range of inlet conditions such as space velocity, oxygen concentrations, water concentration, and $NO_2/NO$ ratio. The parametric investigations are performed to examine how the $NH_3$ slip from a SCR $DeNO_X$ catalyst and the conversion of $NO_X$ are affected by the reaction temperature, $NH_3/NO_X$ feed ratio, and space velocity for feed gas compositions with $NO_2/NO_X$ ratios of 0 and 0.5.

The Effect of Sohabhyangwon(蘇合香元) on Regional Cerebral Blood Flow and Area of Cerebral Infarction in the Experimentally induced Cerebral Infarction in Rats (소합향원(蘇合香元)이 실험적(實驗的) 뇌경색(腦梗塞) 흰쥐의 국소뇌혈류량(局所腦血流量) 및 경색(梗塞) 면적에 미치는 영향(影響))

  • Choi, Eun-Jeong;Shin, Gil-Cho;Lee, Won-Chul
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.456-469
    • /
    • 1997
  • The cerebral infarction arised from occulsion of cerebral artery has a high mortality rate and fatal sequelae. Sohabhyangwon(蘇合香元) is generally regarded to have a effect of walking up the patient from unconsiousness and promoting the flow of Qj(氣) by warming channel. METHOD The purpose of this study is to find out the effections of Sohabhyangwon(蘇合香元) on regional cerebral blood flow and relative cerebral infarction area in the experimentally induced infartion in rats In this experiment, 12 Spraque-Dawley rats weighting 280-350g were used. Cerebral ischemia induced by intraluminal suture technique of Kozumi's and Zea-Longer's method. $Co_{2},\;O_2$, pH, arterial blood pressure in rats were checked by Blood Gas Analyzer every 30 minutes for 2 hours. And regional cerebral blood flow were checking by hydrogen clearance technique, cerebral infarcted area was megsured by Image Analysis System. RESULTS 1. During the experiment, $CO_{2},\;O_2$, pH, arterial blood pressure in rats had no change in both sample group and control group. 2. Cortical cerebral blood flow decreased at same rate in both sample group and control group after inducing cerebral infarction. 3. On comparison of relative cerebral infarcted area, Sohabhyangwon(蘇合香元) perfused group showed a significant decrease. CONCLUSION According to the result above, Sohabhyangwon has a protection effect on cranial nerve and-has no effect on cerebral blood flow.

  • PDF

a-C:H Films Deposited in the Plasma of Surface Spark Discharge at Atmospheric Pressure. Part I: Experimental Investigation

  • Chun, Hui-Gon;K.V. Oskomov;N.S. Sochungov;Lee, Jing-Hyuk;You, Yong-Zoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.5
    • /
    • pp.357-363
    • /
    • 2003
  • The aim of this work is the synthesis of a-C:H films from methane gas using surface spark discharge at the atmospheric pressure. Properties of these films have been investigated as functions of energy W delivered per a methane molecule in the discharge. The method enables the coatings to be deposited with high growth rates (up to $100 \mu\textrm{m}$/hour) onto large-area substrates. It is shown that the films consist of spherical granules with diameter of 20∼50 nm formed in the spark channel and then deposited onto the substrate. The best film characteristics such as minimum hydrogen-to-carbon atoms ratio H/C=0.69, maximum hardness $H_{v}$ =3 ㎬, the most dense packing of the granules and highest scratch resistance has been obtained under the condition of highest energy W of 40 eV. The deposited a-C:H coatings were found to be more soft and hydrogenated compared to the diamond-like hydrogenated (a-C:H) films which obtained by traditional plasmaenhanced chemical vapor deposition methods at low pressure (<10 Torr). Nevertheless, these coatings can be potentially used for scratch protection of soft plastic materials since they are of an order harder than plastics but still transparent (the absorption coefficient is about $10^4$$10^{5}$ $m^{-1}$ At the same time the proposed method for fast deposition of a-C:H films makes this process less expensive compared to the conventional techniques. This advantage can widen the application field of. these films substantially.y.

Monitoring and Controlling Uniformity of Plasma Emission Intensity for IGZO Sputtering Process (IGZO박막 증착 공정에서 플라즈마 방출광 모니터링 및 플라즈마 균일도 제어)

  • Choi, Jinwoo;Hwang, Sang Hyuk;Kim, Woo Jae;Shin, Gi Won;Kwon, Heui Tae;Jo, Tae Hoon;Woo, Won Gyun;Cha, Sung Duk;An, Byung Chul;Park, Wan Woo;Do, Jae Chul;Kwon, Gi-Chung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.4
    • /
    • pp.27-32
    • /
    • 2016
  • In recent years, various researches have been conducted to improve process yields in accordance with miniaturization of semiconductor. APC(Advanced Process Control) is considered one of the methods to increase in process yields. APC is a process control technology that maintains optimal process conditions and improves the reliability of results by controlling and formulating the relationship among the various process parameters and results. We built up an optical diagnostic system with a three-channel spectrometer. The system detects signals those represent the changes of specific emission peaks intensity versus each reference and converts it into MFC control signals to get back the changes to the reference state. Controlling the MFC continues until the specific peak intensity changes into the normal state. Through this device, we tested a APC automatically responding to process changes during the plasma process. We could control gas flow while sputtering process on going and improve uniformity of plasma intensity with this system. Finally, we have got results those enhance the plasma intensity non-uniformity to 7.7% from 15.5%. Also, found unexpected oxygen flow what is estimated to be come out from IGZO target.

The effect of Volume Expansion on the Propagation of Wrinkled Laminar Premixed Flame

  • Chung, E.H.;Kwon, Se-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.139-154
    • /
    • 1998
  • Under certain circumstance, premixed turbulent flame can be treated as wrinkled thin laminar flame and its motion in a hydrodynamic flow field has been investigated by employing G-equation. Past studies on G-equation successfully described certain aspects of laminar flame propagation such as effects of stretch on flame speed. In those studies, flames were regarded as a passive interface that does not influence the flow field. The experimental evidences, however, indicate that flow field can be significantly modified by the propagation of flames through the volume expansion of burned gas. In the present study, a new method to be used with G -equation is described to include the effect of volume expansion in the flame dynamics. The effect of volume expansion on the flow field is approximated by Biot-Savart law. The newly developed model is validated by comparison with existing analytical solutions of G -equation to predict flames propagating in hydrodynamic flow field without volume expansion. To further investigate the influence of volume expansion, present method was applied to initially wrinkled or planar flame propagating in an imposed velocity field and the average flame speed was evaluated from the ratio of flame surface area and projected area of unburned stream channel. It was observed that the initial wrinkling of flame cannot sustain itself without velocity disturbance and wrinkled structure decays into planar flame as the flame propagates. The rate of decay of the structure increased with volume expansion. The asymptotic change in the average burning speed occurs only with disturbed velocity field. Because volume expansion acts directly on the velocity field, the average burning speed is affected at all time when its effect is included. With relatively small temperature ratio of 3, the average flame speed increased 10%. The combined effect of volume expansion and flame stretch is also considered and the result implied that the effect of stretch is independent of volume release.

  • PDF

Development and Characterization of Helium Microwave Plasma Torch (헬륨 마이크로파 플라즈마 토치의 개발과 특성에 관한 연구)

  • Jo, Kyung Hyun;Pak, Yong Nam
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.573-580
    • /
    • 2000
  • MPT, which has been developed recently, is very tolerant to aqueous samples. Several types of MPT have been investigated and is found that the double concentric tube could sustain a stable plasma at a low plasma gas flow rate. However, the tip of torch is easily ruined. Triple concentric torch has shown the best stability and the plasma shape, much like that of ICP, especially when the central channel is quartz. The plasma is exposed and mixed with air as is suggested from the background spectrum, which leads to quenching of He MPT. Sensitivity of helium MPT equipped with a membrane desolvator has shown 10 times lower than that of Argon MPT for most of elements except for the ones with relatively high excitation energy. He MPT requires small plasma flow rate (about 1.6 L/min), stable and simple to use. Excitational temperature and electron number density measured are 4950 K and 3.28 ${\times}$ $10^{14}cm^{-3}$, respectively.

  • PDF

An experimental study on the performance improvement of dead-end type PEMFC with pulsating effect (맥동 효과를 이용한 dead-end type 연료전지의 성능향상에 대한 실험적 연구)

  • Choi, Jong-Won;Seo, Jeong-Hoon;Hwang, Yong-Sheen;Lee, Dae-Heung;Cha, Suk-Won;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.567-571
    • /
    • 2008
  • PEM Fuel Cell operation mode can be classified into dead-end mode or open mode by whether the outlet port is blocked or not. Generally, dead-end type fuel cell has some merits on the pressure drop and system efficiency because it can generate more power than the open type fuel cell due to high operating pressure condition. However, the periodic purging process should be done for removing water which is formed as product of a reaction in the gas diffusion layer. In this study, cathode side dead-end type operation has been conducted. Moreover, pulsating flow generator at the outlet of cathode side has been suggested for increasing the period to purge the formed water because the pulsating flow can make formed water scattered uniformly over the whole channel. As a result, the purging period with pulsation increased by 1.5-2 times longer than that without pulsating.

  • PDF

Analysis of Tropospheric Carbon Monoxide in the Northeast Asia from MOPITT

  • Lee, Sang-Hee;Choi, Gi-Hyuk;Lim, Hyo-Suk;Lee, Joo-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.3
    • /
    • pp.217-221
    • /
    • 2003
  • The Measurement of Pollution in the Troposphere (MOPITT) instrument is an eight-channel gas correlation radiometer that launched on the Earth Observing System (EOS) Terra spacecraft in 1999. Its main objectives are to measure carbon monoxide (CO) and methane (CH4) concentrations in the troposphere. This study analyzes tropospheric carbon monoxide distributions using MOPITT data and compare with ozone distributions in Northeast Asia. In general, seasonal CO variations are characterized by a peak in spring and decrease in summer. Also, this study revealed that the seasonal cycles of CO are maximum in spring and minimum in summer with average concentrations ranging from 118ppbv to 170ppbv. The monthly average of CO shows a similar profile to those of O3. This fact clearly indicates that the high concentration of CO in spring is caused by two possible causes: the photochemical CO production in the troposphere, or the transport of the CO in the northeast Asia. The CO and $O_3$ seasonal cycles in the Northeast Asia are influenced extensively by the seasonal exchange of the different types of air mass due to the Asian monsoon. The continental air masses contain high concentrations of $O_3$ and CO due to higher continental background concentrations and sometimes due to the contribution of regional pollution. In summer the transport pattern is reversed. The Pacific marine air masses prevail over Korea, so that the marine air masses bring low concentrations of CO and $O_3$, which tend to give the apparent minimum in summer.

A study on the friction head loss in flat aluminum micro multi tubes with nonazeotropic refrigerant mixtures R-410A (비공비 혼합냉매 R-410A를 적용한 납작한 알루미늄 마이크로 멀티 튜브에서의 마찰손실에 관한 연구)

  • Lee, Jeong-Kun;Min, Kyung-Ho
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.37-43
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer friction loss headby using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat enhancement factor and pressure drop penalty factor. 1) The friction head loss showed an increase as the vapor quality and mass flux increased. In case of saturation temperature, it shows an increase as it gets lower. These factors are the reason occurring as the lower the saturation temperature is, the higher the density of refrigerant vapor gets. The influence of heat flux is similar as the dryness is low, but as it gets higher, it lowers in heat flux, and as the high temperature of high heat flux, it is a factor that occurs as the density gets lower. 2) RMS error of the in case of friction head loss, it showed to be predicted as 0.45~0.67 by Chisholm, Friedel, Lockhart and Martinelli. 3) As forfriction head loss penalty factor, the smaller the aspect ratio is, the larger the penalty factor gets, and as for the effect of micro-fin, the penalty factor increased because it decreases to the gas fluid the way groove for the refrigerant's flow.