• Title/Summary/Keyword: Gas accident

Search Result 627, Processing Time 0.022 seconds

Numerical study of progressive collapse in reinforced concrete frames with FRP under column removal

  • Esfandiari, J.;Latifi, M.K.
    • Advances in concrete construction
    • /
    • v.8 no.3
    • /
    • pp.165-172
    • /
    • 2019
  • Progressive collapse is one of the factors which if not predicted at the time of structure plan; its occurrence will lead to catastrophic damages. Through having a glance over important structures chronicles in the world, we will notice that the reason of their collapse is a minor damage in structure caused by an accident like a terrorist attack, smashing a vehicle, fire, gas explosion, construction flaws and its expanding. Progressive collapse includes expanding rudimentary rupture from one part to another which leads to total collapse of a structure or a major part it. This study examines the progressive collapse of a 5-story concrete building with three column eliminating scenarios, including the removal of the corner, side and middle columns with the ABAQUS software. Then the beams and the bottom of the concrete slab were reinforced by (reinforcement of carbon fiber reinforced polymer) FRP and then the structure was re-analyzed. The results of the analysis show that the reinforcement of carbon fiber reinforced polymer sheets is one of the effective ways to rehabilitate and reduce the progressive collapse in concrete structures.

Study on quantitative danger evaluation technique about frequency and strength of occurrences through accident analysis of laboratories (실험실의 사고분석을 통한 발생빈도 및 강도의 정량적 위험성 평가 기법에 관한 연구)

  • Kim, Jong-In;Rie, Dong-Ho;Choi, Soon-Young
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.11a
    • /
    • pp.623-631
    • /
    • 2008
  • In this study, with the objects of 173 institutions of university and research institutions, investigation was carried out through visit investigation and questionnaire investigation. Frequency and strength of occurrences was acquired mainly through universities and research institutions which have reported occurrences of accidents to the Ministry of Education, Science, and Technology. Quantitative danger evaluation was conducted through frequency and strength of occurrences. Case study was carried out by selecting bio science laboratory of university and as the result of this study, degree of danger among the inspection objects of bio science laboratories, laboratory work place was evaluated as the most dangerous with the scores of 155.00 and as the result of average danger level, compression gas cylinder was evaluated as the most dangerous with the scores of 6.4000.

  • PDF

The effect of international oil price on LNG price in South Korea and Japan

  • Kwon, Hyukdong;Cho, Hong Chong
    • Geosystem Engineering
    • /
    • v.21 no.6
    • /
    • pp.297-308
    • /
    • 2018
  • In this paper, we investigate the differences between LNG price of South Korea and Japan. Although S. Korean and Japanese LNG markets have similar structures, there are some differences in the price formation. From DCC-MGARCH, we confirm that Japan LNG price have less persistence of disturbance on time than S. Korean LNG price. The conditional correlation also shows linkage effects between LNG prices and impacts of S-curve and DS-curve. Moreover, ARDL estimation result shows that there is co-integration in all models and that impacts of Fukushima accident and LNG volumes are responsible for the increase in Japanese LNG price. Also, adjustment speed of error correction term shows that Japan's deviation from long-run equilibrium disappears faster than S. Korea does, indicating relatively strong Japanese linkage between LNG price and oil price.

Evaluation of temperatures and flow areas of the Phebus Test FPT0

  • Koji Nishida;Naoki Sano;Seitaro Sakurai;Michio Murase
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.886-892
    • /
    • 2024
  • The cladding temperatures and axial mass distribution computed by MAAP5 were compared with their measured values in the test bundle of the Phebus Test FPT0. The computed cladding temperatures were in good agreed with the measured values in the pre-transient phase. In the transient heat-up phase, the computed temperatures were overestimated by the Baker-Just correlation in MAAP5, but the computed temperatures could simulate the subsequently measured values. The computed mass distribution in the axial direction was in qualitative agreement with the measured one for post-test fuel damage observations. The calculated flow areas of inner and outer regions in the test bundle were compared with the photographic observations. MAAP5 computed them at the height of 0.2 m where the molten pool formed was in qualitative agreement with the photographic observations. It was found that the remaining steam flow paths might be caused by the gas-liquid two-phase flow counter-current flow limitation.

Microstructure Observation of the Grain Boundary Phases in ATF UO2 Pellet with Fission Gas Capture-ability (핵분열 기체 포획 기능을 갖는 사고저항성 UO2 펠렛에서 형성되는 입계상의 미세구조 관찰)

  • Jeon, Sang-Chae;Kim, Dong-Joo;Kim, Dong Seok;Kim, Keon Sik;Kim, Jong Hun
    • Journal of Powder Materials
    • /
    • v.27 no.2
    • /
    • pp.119-125
    • /
    • 2020
  • One of the promising candidates for accident-tolerant fuel (ATF), a ceramic microcell fuel, which can be distinguished by an unusual cell-like microstructure (UO2 grain cell surrounded by a doped oxide cell wall), is being developed. This study deals with the microstructural observation of the constituent phases and the wetting behaviors of the cell wall materials in three kinds of ceramic microcell UO2 pellets: Si-Ti-O (STO), Si-Cr-O (SCO), and Al-Si-Ti-O (ASTO). The chemical and physical states of the cell wall materials are estimated by HSC Chemistry and confirmed by experiment to be mixtures of Si-O and Ti-O for the STO; Si-O and Cr-O for SCO; and Si-O, Ti-O, and Al-Si-O for the ASTO. From their morphology at triple junctions, UO2 grains appear to be wet by the Si-O or Al-Si-O rather than other oxides, providing a benefit on the capture-ability of the ceramic microcell cell wall. The wetting behavior can be explained by the relationships between the interface energy and the contact angle.

A Study on Workers' Risk-Aware Smart Bands System in Explosive Areas (폭발위험지역 근로자 위험 인지형 스마트밴드시스템에 대한 연구)

  • Lee, Byong-Kwon
    • Journal of Internet of Things and Convergence
    • /
    • v.5 no.2
    • /
    • pp.73-79
    • /
    • 2019
  • Research is underway on services and systems that provide real-time alerts for suffocating gases and potentially explosive materials, but currently smart bend type services are lacking. This study supports real-time identification of explosion hazards due to static electricity in the workplace and immediate elimination of accident occurrence factors, real-time monitoring of worker status and workplace hazards (oxygen, hazardous chemical concentration), and immediate warning and data in case of danger. We propose a method of establishing an accident prevention system through analysis. In this way, various accidents that may occur in industrial sites are monitored using IoT-based intelligent sensor nodes, wireless network technology, data processing middleware, and integrated control system, and real-time risk information at the industrial sites is prevented and accidents are prevented. By supporting a safe working environment, the company can significantly reduce costs compared to post-procurement costs.

Adverse Effects on Crops and Soils Following an Accidental Release of Hydrogen Fluoride and Hydrofluoric Acid

  • Kang, Dae-Won;Kim, Hyuck-Soo;Kunhikrishnan, Anitha;Kim, Da-In;Lee, Seul;Park, Sang-Won;Yoo, Ji-Hyock;Kim, Won-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.6
    • /
    • pp.651-654
    • /
    • 2016
  • A number of accidents relating to highly toxic hydrogen fluoride (HF) or hydrofluoric acid (HA) release have occurred over fast few decades in Korea. Thus, this study was conducted to investigate the fluoride (F) concentrations in paddy soil and brown rice from 2 different areas where the soils were exposed to HF and HA. In the first case, the HF leakage accident that occurred in 2012 affected the surrounding soils and crops and consequently, crops (rice) affected by HF were unavailable for forage even though F did not accumulate in the soil. For example, at the time of accident, F concentrations in brown rice samples were $33.0-1,395mg\;kg^{-1}$, while F concentrations in soil samples were $155-295mg\;kg^{-1}$ which were less than the Korean standard guideline values of $400mg\;kg^{-1}$. However, after a year, F concentrations in brown rice were observed below the detection limit ($1mg\;kg^{-1}$), although F concentrations in soils were similar with those in 2012. Also, large amounts of wastewater discharges containing HA occurred in 2013 and some agricultural soils exceeded the Korean standard guideline values for F ($400mg\;kg^{-1}$), but soil-plant F transfer was not observed. In conclusion, it was observed that soil to plant transfer of F is unlikely although HF and HA as gas or liquid form can cause direct damage to plants.

PARAMETRIC STUDIES ON THERMAL HYDRAULIC CHARACTERISTICS FOR TRANSIENT OPERATIONS OF AN INTEGRAL TYPE REACTOR

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Song, Chul-Hwa;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.185-194
    • /
    • 2006
  • Transient operations for an integral type reactor, SMART-P, have been experimentally investigated using a thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), in order to verify the system design and performance of the SMART-P, a pilot plant of SMART. The VISTA facility was subjected to various accident conditions such as feedwater increase and decrease, loss of coolant flow, and control rod withdrawal accidents in order to elucidate the thermal-hydraulic responses following such accidents and finally to verify the system design of the SMARTP. Full functional control logics have been implemented in the VISTA facility in order to control the required control action for an accident simulation. As one of the sensitivity tests to verify the PRHRS performance, the effects of the initial water level in the compensation tank are experimentally investigated. When the initial water level is 16%, the water is quickly drained and nitrogen gas is then introduced into the PRHR system, resulting in deterioration of the PRHRS performance. It is thus found that nitrogen ingression should be prevented to ensure stable PRHRS operation.

Accident Prevention in Confined Space Using IoT Technology (IoT 기술을 활용한 밀폐공간에서의 사고 예방 연구)

  • Choi, Yoo-jung;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.9
    • /
    • pp.1159-1164
    • /
    • 2018
  • Recently, Internet use is increasing in various fields. Especially in the sudden disaster area, the role of Internet of things that can continuously monitor is getting bigger. In this study, the characteristics of the confined space and the environmental hazards are examined, and the Internet of the object which is being commercialized will be reviewed. Accidents in confined spaces are very high compared to other places, and it is very difficult to predict accidents. Recently, various attempts have been made to prevent accidents in confined spaces using the Internet of things. Especially, it detects the various gases that can occur in the closed space using sensors and sends them to the workers in real time, so that the risk can be detected in advance to minimize the risk. In this paper, we propose an effective disaster prevention plan using the Internet of things through the case study of the Internet for the prevention of accidents in a confined space.

Enhancement of Pool Boiling Heat Transfer in Water Using Sintered Copper Microporous Coatings

  • Jun, Seongchul;Kim, Jinsub;Son, Donggun;Kim, Hwan Yeol;You, Seung M.
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.932-940
    • /
    • 2016
  • Pool boiling heat transfer of water saturated at atmospheric pressure was investigated experimentally on Cu surfaces with high-temperature, thermally-conductive, microporous coatings (HTCMC). The coatings were created by sintering Cu powders on Cu surfaces in a nitrogen gas environment. A parametric study of the effects of particle size and coating thickness was conducted using three average particle sizes (APSs) of $10{\mu}m$, $25{\mu}m$, and $67{\mu}m$ and various coating thicknesses. It was found that nucleate boiling heat transfer (NBHT) and critical heat flux (CHF) were enhanced significantly for sintered microporous coatings. This is believed to have resulted from the random porous structures that appear to include reentrant type cavities. The maximum NBHT coefficient was measured to be approximately $400kW/m^2k$ with APS $67{\mu}m$ and $296{\mu}m$ coating thicknesses. This value is approximately eight times higher than that of a plain Cu surface. The maximum CHF observed was $2.1MW/m^2$ at APS $67{\mu}m$ and $428{\mu}m$ coating thicknesses, which is approximately double the CHF of a plain Cu surface. The enhancement of NBHT and CHF appeared to increase as the particle size increased in the tested range. However, two larger particle sizes ($25{\mu}m$ and $67{\mu}m$) showed a similar level of enhancement.