• Title/Summary/Keyword: Gas Station

Search Result 474, Processing Time 0.033 seconds

TNT Explosion Demonstration and Computational Fluid Dynamics for Safety Verification of Protection Wall in Hydrogen Refueling Station (수소충전소 방호벽 안전성 검증을 위한 TNT 폭발실증 및 전산유동 해석)

  • Yun-Young Yang;Jae-Geun Jo;Woo-Il Park;Hyon Bin Na
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.102-109
    • /
    • 2023
  • In realizing a hydrogen society, it is important to secure the safety of the hydrogen refueling station, which is the facility where consumers can easily meet hydrogen. The hydrogen refueling station consists of compressed gas facilities that store high-pressure hydrogen, and there is a risk that the high-pressure compressed gas facility will rupture due to a fire explosion due to hydrogen leakage in the facility or the influence of surrounding fires. Accordingly, the Korea Gas Safety Corporation is making every effort to find out risk factors from the installation stage, reflect them in the design, and secure safety through legal inspection. In this study, a TNT explosion demonstration test using a protection wall was conducted to confirm the safety effect of the protection wall installed at the hydrogen refueling station, and the empirical test results were compared and verified using FLACS-CFD, a CFD program. As a result of the empirical test and CFD analysis, it was confirmed that the effect of reducing the explosion over-pressure at the rear end of the protection wall decreased from 50% to up to 90% depending on the location, but the effect decreased when it exceeded a certain distance. The results of the empirical test and computer analysis for verifying the safety of the protection wall will be used in proposals for optimizing the protection wall standards in the future.

An empirical study on the effect of choice factors of gas station on repurchase intention (소비자의 주유소 선택요인이 재구매의도에 미치는 영향에 관한 실증적 연구)

  • Lee, Seon-Gyu;Lee, Ung-Hui
    • 한국디지털정책학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.191-204
    • /
    • 2007
  • This research investigates the present situation of petroleum market and the potential strategy which help gas stat ion obtain compel it ive advantages. Specifically, this research chooses five factors (product quality, service, price, multi-function, easy entrance) which are believed to be extensively related to repurchasing intent ion. The findings are as follows ; First, four factors associated wi th gas stat ion choice (product quality, service, price, multi-function) are related to repurchase intent ion except easy entrance. Second, sex and age have moderating effects between factors and repurchase intention. To keep and preoccupy new customers, the administrators of petroleum industry and gas station should establish sales/administration strategies considering these above.

  • PDF

Investigation of Ventilation Efficiency for the Natural Gas High Pressure Release in an Underground Valve Station (지하 공급관리소내 천연가스 고압분출시 환기효율성 검증)

  • Ha J. M.;Lee J. H.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.74-80
    • /
    • 2002
  • This study was carried out for the purpose of safety evaluation about the ventilation system (according to the structure of confined room, the position and size of vent window, the amount of blowing air, e.t.c.), which is equipped in one of KOGAS underground valve stations. Particularly, the effect of the fans placed in the upper region was focused in detail. Numerical simulation was conducted in order to predict the features of flow pattern and the diffusion of natural gas concentration. This work examined the ventilation system and resulted in proposing an optimal design of ventilation system.

  • PDF

A Study on the Transaction Volume Calculation model for Improving the Measurement Accuracy of Hydrogen Fuelling Station (수소충전소 계량 정확도 향상을 위한 거래량 산출 모델 연구)

  • JINYEONG CHOI;HWAYOUNG LEE;SANGSIK LIM;JAEHUN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.692-698
    • /
    • 2022
  • With the expansion of domestic hydrogen fuelling station infrastructure, it is necessary to secure reliability among hydrogen traders, and for this, technology to accurately measure hydrogen is important. In this study, 4 types of hydrogen trading volume calculation models (model 1-4) were presented to improve the accuracy of the hydrogen trading volume. In order to obtain the reference value of model 4, and experiment was conducted using a flow rate measurement equipment, and the error rate of the calculated value for each model was compared and analyzed. As a result, model 1 had the lowest metering accuracy, model 2 had the second highest metering accuracy and model 3 had the highest metering accuracy until a certain point. But after the point, model 2 had the highest metering accuracy and model 3 had the second metering accuracy.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

A Study on Exposure to Volatile Organic Compounds at Gas Stations in Korea (국내 일부 주유소 내에서의 휘발성 유기화합물 노출에 관한 연구)

  • Song, Sang Hwan;Paik, Nam Won;Ha, Kwon Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.58-73
    • /
    • 2000
  • Objectives : This study was performed to evaluate BTEX exposure to gas station service attendants and the critical affect of benzene and MtBE airborne concentration. Methods : the degree of exposure to airborne BTEX and MtBE was examined in the service attendants at seven gas stations across the country during a summer season. The TWAs(time-weighted averages) of atmospheric concentration of substances in personal and area samples, were calculated. The component ratio of BTEX and MtBE in the samples of bulk gasoline from each station studied was also measured. Results : The airborne concentrations of BTEX and MtBE showed a lognormal distribution and The TWA concentrations of benzene in personal samples from each station were 0.089 ppm - 0.18 ppm, and those of toluene were 0.097 ppm - 0.2 ppm. The average TWA concentrations of xylene and ethyl benzene was 0.03 ppm and 0.001 ppm, respectively. The TWA concentrations of MtBE were 0.4 ppm - 1.3 ppm. The volume concentrations of MtBE, toluene, ethyl benzene and xylene in the bulk gasoline samples were 3 - 7.4 %, 3 - 12 %, 0.64 % and 1.5 - 10 %, respectively. Conclusions : The benzene concentration was detected to exceed the ACGIH threshold benzene level of 0.5 ppm, in one of 74 personal and area samples. MtBE, a substitute for aromatic compounds such as benzene in gasoline, was found to bring about a greater chance of exposure to carcinogen, due to its high vapor pressure and carcinogenicity.

  • PDF

Self-Service Model Considering Learning Effect : Self-Service Gas Station (학습효과를 고려한 셀프서비스 모델 : 셀프서비스 주유소 분석)

  • Jung, Sung Wook;Yang, Hongsuk;Kim, Soo Wook
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.37 no.4
    • /
    • pp.73-93
    • /
    • 2012
  • In recent years, service delivery systems employing a self-service approach have been rapidly spreading. Since a self-service system provides a lower product price, it attracts more customers. However, some system managers are still hesitant to accept a self-service system, because there is no systematic model to predict its performance. Therefore, this research attempts to provide a systematic and quantitative model to predict the performance of a self-service system, focused specifically on a self-service gas station. Under this model, the traditional queuing theory was adopted to describe the general self-service process, but it is also assumed that some changes occur in both the customer arrival rate and the service performance rate. In particular, the price elasticity was introduced to capture the change in the customer arrival rate, and the existence of learning effect and helpers were assumed to design the changed service performance rate. Under these assumptions, a simulation model for a self-service gas station is established, and three performance measurements, such as average number of customers, average waiting time, and Utilization are observed, depending on the changes in price difference and helper-operating time. In this research, the optimal operation strategy for price differentiation and helper-operating time is proposed in accordance with the level of the customer learning rate. Although this research confines the scope of the study to the self-service gas station model, the results of this research can be applied to any type of self-service system.

The Hazard Assessment of Release and Dispersion of CNG Service Station (CNG 충전소의 누출$\cdot$확산에 대한 위험성 평가)

  • Choi Jong-Woon;Lee Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.53-58
    • /
    • 2000
  • It was carried out consequence analysis(CA) of CNG (compressed natural gas) service station and we compared the results of CA of CNG service station with LPG service station which was installed by high Pressure gas law. The results of CA were that distance of CNG LFL was 1.5 times than the length of LPG LFL. Thermal radiation effect about CNG may not be showed damage of process facilities, but in the case of LPG, it was enough to have an large damage effect on a downtown. The thermal radiation of 37.5 $kw/m^2$ extended 12.6 m. Also, in the case of 12.5 $kw/m^2$ which was able to burn wood, the radiation effect of LPG is 3 times than CNG.

  • PDF

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station (II) - Flow Analysis and Required Effective Discharge Area of Safety Valve - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석 (II) - 안전밸브 유동 해석 및 필요분출면적 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.105-109
    • /
    • 2008
  • A safety valve has a valve mechanism for the automatic release of gas from piping system when the pressure exceeds preset limit cause of a defect of a pressure regulator, condensation of water in a pipe. Therefore, for the safety of pressure regulating station, it is essential to study the flow regime and characteristics of safety valve. This article presents the numerical analysis on the flow analysis, the ejection capacity and required effective discharge area of the safety valve that is established in pressure regulating station. Then, the results are compared and analyzed with domestic and foreign regulations such as API(America Petroleum Institute), EN(European Standard), and NF(Norme Francise). Moreover, the installation number of safety valve is considered by using domestic and foreign regulations and maximum reguired effective discharge area of safety valve.

  • PDF