• 제목/요약/키워드: Gas Sampling System

검색결과 119건 처리시간 0.028초

천연가스의 열용량을 측정하기 위한 촉매가스센서의 특징 (Characterization of A Catalystic Gas Sensor for Measuring Heat Content of Natural Gas)

  • 이기용
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 1997년도 추계학술발표회 논문집
    • /
    • pp.229-235
    • /
    • 1997
  • A low power (300 mW) catalytic bead combustible gas sensor is developed and utilized with a computer controlled sampling system for measuring heat content of natural gas. The heat content of gas is proportional to the change in the energy required to exposure to the sample of combustible gas. The heat content of natural gas samples ranging 36.30 - 39.88 MJ/$m^3$ is measured in the range of approximately $1\%$ error, which is comparable to its nominal heat content. Each gas has a slightly different curve of sensitivity vs. sensor temperature. Thus there Is no temperature at which all sensitivities are equal. In calibration process the choice of a optimum operating temperature is an important factor that influences the overall performance of the measurement system.

  • PDF

비분산 적외선 분광법을 이용한 Co2농도 고속 분석기의 Sampling Module 특성에 관한 실험적 연구 (An Experimental Investigation into the Characteristics of Sampling Module for East-Response Co2 Concentration Analyzer with NDIR)

  • 김우석;손덕영;박영무;유재석;이종화
    • 대한기계학회논문집B
    • /
    • 제27권3호
    • /
    • pp.398-405
    • /
    • 2003
  • A fast response analyzer for measuring carbon dioxide concentration has been developed for transient characteristic and researches tested on internal combustion engine. The analyzer uses the well known NDIR(Non-Dispersive Infrared) method with miniaturized detection system, giving a time constant of approximately 30 microsecond, and sampling module consists of capillary tube. Since the transit time and the time constant of the sampling system depend on the sampling conditions, it is necessary to investigate the characteristics of sampling system before applied to exhaust gas measurement in engine. A unique method was designed to study the influence of the diameter of transfer sample line and operating conditions of the FRNDIR on transit time and time constant. A database of transit time and time constant was built up for different measured and simulated pressure conditions. The database can be used for correcting eventual $CO_2$ concentration measurement.

고온로를 이용한 매연발생장치 (Soot Generation System Utilizing High-Temperature Furnace)

  • 조상환;박선호;남연우;최유열;이원남
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.55-58
    • /
    • 2013
  • A new soot particle generation system has been developed and tested. The soot generation system consists of two sections, a fuel supply and a soot production. In the fuel supply module, either liquid fuel precisely controlled by a syringe pump is mixed with preheated carrier gas and rapidly evaporated or gaseous fuel controlled by a MFC is diluted with dilution gas. The soot production module contains a heater that can raise the gas/fuel temperature up to $1400^{\circ}C$. The physical and chemical properties of produced soot particles depend on the type and concentration of fuel, the residence time, and temperature in the soot production section. The soot generation system will be utilized to produce well-defined soot particles for soot studies such as the evaluation of experimental sampling and analysis processes for the quantitative assessment of PM and BC from ships and the adverse health effects on pulmonary and cardiovascular systems of human body.

  • PDF

테플론 여과지를 이용한 미세입자 무기이온 성분 측정에서의 오차 정량 (Quantification of Sampling Artifacts in PM2.5 Inorganic Ion Species using Teflon Filter)

  • 김정연;김용표
    • 한국대기환경학회지
    • /
    • 제23권1호
    • /
    • pp.74-83
    • /
    • 2007
  • Artifacts due to inter-particle and gas-particle interactions during PM2.5 sampling were quantified by comparing the measurement results between the annular denuder-filterpack system and the filterpack system without denuder. Measurements were carried in Seoul for 10 days in each season; Nov. 2004, Jan. 2005, Mar. 2005, and Jul. 2005, respectively. In each day, two 12-h samples were obtained. The concentrations of nitrate and chloride showed seasonal variations mainly due to the availability of ammonium to neutralize nitrate or chloride. Nitrates and chloride losses were prominent in summer. Since most of ammonia was used to neutralize sulfuric acid and formed ammonium sulfate in summer, nitrate and chloride could not exist in particles and ammonium loss was smaller than other seasons.

Design of Improved Detection Instrumentation for the Annulus Gas System for Wolsong 2

  • Kim, Seog-Nam;Koo, Jun-Mo;Chang, Ik-Ho;Jung, Ho-Chang;Han, Sang-Joon
    • Nuclear Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.423-430
    • /
    • 1996
  • The improved and advanced Annulus Gas System(AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board(AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. no improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided.

  • PDF

Modeling and Simulation for PIG with Bypass Flow Control in Natural Gas Pipeline

  • Nguyen, Tan-Tien;Kim, Sang-Bong;Yoo, Hui-Ryong;Park, Yong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제15권9호
    • /
    • pp.1302-1310
    • /
    • 2001
  • This paper introduces modeling and simulation results for pipeline inspection gauge (PIG) with bypass flow control in natural gas pipeline. The dynamic behaviour of the PIG depends on the different pressure across its body and the bypass flow through it. The system dynamics includes: dynamics of driving gas flow behind the PIG, dynamics of expelled gas in front of the PIG, dynamics of bypass flow, and dynamics of the PIG. The bypass flow across the PIG is treated as incompressible flow with the assumption of its Mach number smaller than 0.45. The governing nonlinear hyperbolic partial differential equations for unsteady gas flows are solved by method of characteristics (MOC) with the regular rectangular grid under appropriate initial and boundary conditions. The Runge-Kuta method is used for solving the steady flow equations to get initial flow values and the dynamic equation of the PIG. The sampling time and distance are chosen under Courant-Friedrich-Lewy (CFL) restriction. The simulation is performed with a pipeline segment in the Korea Gas Corporation (KOGAS) low pressure system, Ueijungboo-Sangye line. Simulation results show us that the derived mathematical model and the proposed computational scheme are effective for estimating the position and velocity of the PIG with bypass flow under given operational conditions of pipeline.

  • PDF

프로판 엔진의 배기 포트에서 탄화수소 산화율 추정 (Estimation of Hydrocarbon Oxidation by Measuring He Concentrations in an SI Engine Exhaust Port)

  • 이형승;박종범;민경덕;김응서
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.660-667
    • /
    • 2000
  • In order to investigate the exhaust structure and secondary oxidation of unburned hydrocarbon (HC) in the exhaust port, concentrations of individual HC species were measured in exhaust process, the degree of oxidation were obtained. Using a solenoid-driven fast sampling system on single-cylinder research engine fueled with 94% propane, the profiles of unburned hydrocarbons (HCs) and non-fuel HCs with a propane fueled engine were obtained from several locations in the exhaust port during the exhaust process. The sampled gases were analyzed using a gas chromatography of HC species with 4 or lesser carbon atoms. The change of total HC concentration and HC fractions of major components through the exhaust port were discussed. The results showed that non-uniform distribution of HC concentration existed around the exhaust valve and changed with time, and that the exhaust gas exhibited nearly uniform concentration profile at port exit, which was due to mixing and oxidation. Also it could be known that bulk gas with relatively high HC concentration came out through the bottom of the exhaust valve. To estimate the mass-based degree of HC oxidation in the exhaust port from measured HC concentrations, a 3-zone diagnostic cycle simulation and plug flow modeling were used. The degree of oxidation ranged between 26 % and 36 % corresponding to the engine operation conditions.

전처리 방법에 따른 더덕(Codonopsis lanceolata)의 휘발성 향기성분 비교 분석 (Comparative Sampling Procedures for the Volatile Flavor Components of Codonopsis lanceolata)

  • 김정한;김경례;김재정;오창환
    • 한국식품과학회지
    • /
    • 제24권2호
    • /
    • pp.171-176
    • /
    • 1992
  • 더덕(Codonopsis lanceolata)의 휘발성 향기성분을 분석하기 위해 gas co-distillation(GCD), solvent extraction/fractionation(SLF), headspace sampling(HSS) 방법을 사용하여 향기성분을 분리농축하고 분석 비교한 결과 SEF와 HSS 방법으로 얻은 농축물들의 향이 원래의 더덕향과 가장 유사했으며 gas chromatogram들의 양상도 비슷했으나 peak들의 크기에 있어서 차이를 보였다. SEF 농축물에서는 달콤한 향을 기리고 HSS 농축물에서는 풋내를 비교적 강하게 느낄 수 있었으나 GCD 농축물의 경우 일정 증류시간이 지나면 한악취를 느낄 수 있었다. SEF와 HSS 방법은 GCD에 비해서 적은 조작 단계로 손쉽게 빠른 시간내에 분리 농축이 가능했다. 농축한 향기성분은 GC-MS와 극성이 다른 두 column을 사용한 GC-RI system을 이용하여 확인하였다. 특히 GC-RI는 isomer의 확인에 효과적이었으며 극성 FFAP column은 극성 화합물의 확인에 보다 적합했다. 35가지의 향기성분들을 동정하였는데 그중 24개의 성분들은 simultaneous distillation extraction 농축물에서는$^{(5)}$ 확인되지 않았던 향기성분들이다. 화인된 성분들중 trans-2-hexenal, cis-3-hexen-1-ol, trans-2-hexen-1-ol, hexanol은 더덕의 풋내를, 1-octen-3-ol은 신선한 풍미를 그리고 amyl propionate를 비롯한 다수의 에스터 화합물 등은 더덕 특유의 달콤한 향에 복합적으로 작용할 것으로 추정된다.

  • PDF

2행정 디젤기관의 소기 효율 평가에 관한 연구 (A Study on the Evaluation of Scavenging Efficiency in a Two-Stroke Diesel Engine.)

  • 조규백;강건용;이진욱;정용일
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.49-58
    • /
    • 1998
  • 포핏밸브형 2행정 기관의 소기 시스템 형상 변화에 따른 소기유동 및 소기효율의 개선 효과를 해석하기 위해, 각 흡기포트 형상별 소기 유동 가시화와 소기효율 정량화 연구를 수행하고자 한다. 소기시스템의 형상은 기계연구원에서 독자 개발한 RSSV(Rotatable Shrouded Scavenging Valve)의 슈라우드 각도를 변화시켰으며, 소기 효율 정량화를 위해 정상상태하에서 등유와 착색된 물을 사용한 single-cycle method. 동적모사장치(dynamic simulatior)에서 $CO_2$$O_2$가스를 사용한 가스추출법(gas sampling method)을 적용하였으며 실제 기관에서의 소기 효율을 측정하기 위해 압력 선도를 해석하였다. 위 실험들의 결과로부터 $90^circ$슈라우드 밸브가 가장 높은 효율을 가지는 것으로 판명되었으며, 특히 이들 실험방법들은 2행정 엔진 개발에 있어 시간과 비용을 절감하는데 아주 유용한 기법임을 알 수 있었다.

  • PDF

Feasibility study of a resistive-type sodium aerosol detector with ZnO nanowires for sodium-cooled fast reactors

  • Jewhan Lee;Da-Young Gam;Ki Ean Nam;Seong J. Cho;Hyungmo Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2373-2379
    • /
    • 2023
  • In sodium systems, leakage is one of the safety concerns; it can cause chemical reactions, which may result in fires. There are contact and non-contact types of leak detectors, and the conventional method of non-contact type detection is by gas sampling. Because of the complexity of this method, there has always been a need for a simple gas sensor, and the resistive-type nanostructure ZnO sensor is a promising option with various advantages. In this study, a ZnO sensor was fabricated, and the concept was tested as a leak detector using a dedicated experiment facility. The experiment results showed distinctive changes in resistance with the presence of sodium aerosol under various conditions. Replacing the conventional gas sampling with the ZnO sensors is expected to enable identification of the leakage location if used as a point-wise instrumentation and to greatly reduce the total cost, making the system simple, light, and effective. For further study, more tests will be performed to evaluate the sensitivity of key parameters under various conditions.