• Title/Summary/Keyword: Gas Recovery

Search Result 1,095, Processing Time 0.028 seconds

Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열교환 성능 분석(농업시설))

  • 서원명;강종국;윤용철;김정섭
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF

A Study on the Optimal Conditions of the Biogas Sorting by Using the Polysulfone Membrane (다공성 분리막을 이용한 최적의 Bio-gas 분리인자 도출)

  • Lee, Seung-Won;Jeong, Chang-Hoon;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.1011-1019
    • /
    • 2011
  • The objective of this research is to evaluate optimal conditions of permeability and selectivity on the polysulfone membrane for efficiency of separation of $CH_4$ by checking four factors which are temperature, pressure, gas compositions and gas flow rates. When higher pressure was applied at the input, lower efficiency of recovery of $CH_4$ and higher efficiency of separation of $CH_4$ were shown. It has the tendency to show lower efficiency of recovery of $CH_4$ and higher efficiency of separation of $CH_4$ at the output as higher temperature at input. The lower flow rates make higher efficiency of recovery of $CH_4$ and lower efficiency of separation of $CH_4$. Finally, over 90% efficiency for $CH_4$ separation and recovery conditions are temperature ($-5^{\circ}C$), pressure (8 bar), gas composition rate (6:4) ($CH_4:CO_2$) and gas flow rate ($5\ell$/min). These conditions make higher separation and recovery efficiency such as 90.1% and 92.1%, respectively.

A Study on Urinary Trans, Trans-Muconic acid, Hippuric acid of gas station worker according to the use of gasoline vapor recovery system (유증기 회수설비 유무에 따른 주유소 근로자들의 요중 trans, trans-Muconic acid, Hippuric acid에 관한 연구)

  • Choi, Jaejun;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.152-159
    • /
    • 2014
  • Objectives: This study aims to investigate the excretion aspect of urinary t, t-MA and hippuric acid by measuring concentrations of urinary metabolites according to the use of gasoline vapor recovery system. Materials:In order to analyze urinary metabolites, samples from the 23 gas station workers ten gas stations in the Seoul and Gyeonggi Province area were collected once daily after work. In addition, a survey was conducted on work factors and lifestyle habits as factors affecting the concentration of urinary metabolites. Results: The average concentrations of t, t-MA and hippuric acid after work were $0.124{\pm}0.177mg/g$ creatinine and $0.557{\pm}0.251g/g$ creatinine among workers at gas stations where gasoline vapor recovery systems were installed. The average concentrations of t, t-MA and hippuric acid were $0.160{\pm}0.113mg/g$ creatinine and $0.682{\pm}0.619g/g$ creatinine among workes at gas stations where gasoline vapor recovery systems were not installed. Average concentrations were higher at gas stations where a gasoline vapor recovery system was not installed, but the differences were not statistically significant differences. Urinary t, t-MA and hippuric acid average concentrations of smokers and non-smokers were higher in the gas stations where gasoline a vapor recovery system was not installed. T, t-MA as a factor evaluation affecting the concentration of urinary metabolites was not statistically significant in all factors, while hippuric acid was statistically significant only for age(p=0.024). Conclusions: The average concentrations of urinary t, t-MA and hippuric acid were higher in gas stations where gasoline vapor recovery systems were not installed compared to gas stations where such a system was installed. There needs to be an assessment of biological monitoring according to refueling activity considering skin absorption of benzene and toluene and presence of gasoline vapor recovery system.

Analysis of Thermal Recovery Characteristics for Nozzle of SF6 GCB Considering Nozzle Ablation (노즐용삭을 고려한 SF6 가스차단기 노즐의 열적회복특성 해석)

  • Lee Byeong-Yoon;Song Ki-Dong;Chong Jin-Kyo;Park Kyong-Yop
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • In this paper, a method for analyzing the thermal recovery characteristics of the nozzle of gas circuit breaker was described. In order to obtain thermal recovery characteristics, the transient simulation of SF6 arc plasma within the nozzle was carried out. In particular, the nozzle ablation was taken into account by simultaneously solving the PTFE concentration equation with the governing equations such as continuity, momentum and energy equation. After that, post arc current calculation was performed with the rate of rise of recovery voltage changed. From the calculated post arc current, it was possible to suggest the thermal recovery characteristics of the nozzle of gas circuit breaker.

Optimum Design on the Mixed Ratio of Injection Gas with CO2/N2 in Enhanced Coalbed Methane Recovery (석탄층 메탄가스 회수증진공법에서 CO2/N2 주입가스의 혼합 비율 최적 설계)

  • Yoo, Hyun-Sang;Kim, Young-Min;Lee, Jeong-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.2
    • /
    • pp.1-9
    • /
    • 2017
  • Enhanced coalbed methane recovery (ECBM), as injecting $CO_2$ or $N_2$ into the coalbed methane (CBM) reservoir for increasing methane recovery, takes center stage in these days. ECBM makes a better recovery than the conventional production method, it called dewatering process. However the characteristics of injection gas affect to methane recovery, thus analysis on the mixed ratio of injection gas should be required. In this study, CBM reservoir model was built to estimate the methane recovery of ECBM method by different mixed ratio of injection gas. Additionally, to consider the characteristics of injection gas such as carbon captured storage, nitrogen re-injection, etc. economic analysis was performed. The results showed that ECBM cases produced methane almost twice as much as dewatering case and $CO_2$ 10% and $N_2$ 90% case resulted in the highest methane recovery among the mixed gas cases. On the other hand, the results of economic analysis showed that $CO_2$ 20% and $N_2$ 80% case made the highest total production profit. Therefore, both the recovery of methane and economical efficiency should be considered to apply ECBM process.

Fast Responding Gas Sensors Using Sb-Doped SnO2 Nanowire Networks (Sb-첨가 SnO2 나노선 네트워크를 이용한 고속응답 가스센서)

  • Kwak, Chang-Hoon;Woo, Hyung-Sik;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.302-307
    • /
    • 2013
  • The Sb-doped $SnO_2$ nanowire network sensors were prepared by thermal evaporation of the mixtures between tin and antimony powders. Pure $SnO_2$ nanowire networks showed high sensor resistance in air ($99M{\Omega}$), similar gas responses to 4 diffferent gases (5 ppm $C_2H_5OH$, CO, $H_2$, and trimethylamine), and very sluggish recovery speed (90% recovery time > 800 s). In contrast, 2 wt% Sb-doped $SnO_2$ showed the selective detection toward $C_2H_5OH$ and trimethylamine, relatively low resistance ($176k{\Omega}$) for facile measurement, and ultrafast recovery speed (90% recovery times: 6 - 18 s). The change of gas sensing charactersitics by Sb doping was discussed in relation to gas sensing mechanism.

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF

A Study on the Calculation Method of VOCs Emissions Using Equation of State in the Gas Station Tank (상태방정식을 이용한 주유소 탱크에서의 유증기 배출량 산정법에 관한 연구)

  • Park, Taejoon;Oh, Wheesung;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.42-48
    • /
    • 2015
  • This study was investigated the estimation of VOCs (Volatile Organic Compounds) emission from a gas station tank. To improve the atmosphere environmental quality near the gas station, the installation of vapor recovery system has been expanded recently. Therefore, it was necessary to calculate VOCs emissions from the gas station tank with vapor recovery systems for evaluation of their performance. The VOCs emissions are difficult to measure directly because of various sources and irregularly emission by pressure rise. In this study, VOCs emissions were estimated by simple calculation based on the equation of state for measured pressure, temperature and volume of a gasoline tank at a gas station. The result confirmed that the present national emission factor did not have significant discrepancy with the calculated value.

Evaluation Method II of the Small Current Breaking Performance of SF$_6$-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$가스차단기의 소전류 차단성능 해석기술 II)

  • 송기동;이병윤;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.384-391
    • /
    • 2001
  • The insulation strength between contacts after current interruption to the transient recovery voltage i.e., the dielectric recovery strength should be estimated for the evaluation of the small capacitive current interruption capability. Many authors have used theoretical and semi-experimental approaches to evaluate the transient breakdown voltage after the current interruption. Moreover, an empirical equation, which is obtained from a series of tests, has been used to estimated the dielectric recovery strength. Un this paper, the theoretical method which is generated from the streamer theory has been applied to real circuit breakers in order to evaluated the interruption capability. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

[ $CO_2$ ] Sequestration on Various Structures of Natural Gas Hydrate Layer for Effective Recovery of $CH_4$ Gas

  • Park, Young-June;Choi, Suk-Jeong;Shin, Kyu-Chul;Seol, Ji-Woong;Lee, Hu-En
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.410-411
    • /
    • 2006
  • On the continental margins and in permafrost regions, natural gas, which has been expected to replace petroleum energy, exists In solid hydrate farm. World hydrate reserves Including natural gas are estimated at about twice as much as the energy contained In total fossil fuel reserves. Because of its vast quantities, the efficient recovery of natural gas from natural gas hydrate becomes the most important factor on evaluating the economic feasibility in the sense of commercialization. It has been noted that carbon dioxide, one of the well-known green house gases, possibly can be stored in the ocean floor as a carbon dioxide hydrate. If the natural gas hydrate could be converted into carbon dioxide hydrate, natural gas hydrate deposits would serve as energy sources as well as carbon dioxide storage sites in the deep ocean sediments. In this study, we first attempted to examine the real swapping phenomenon occurring between guest molecules and various structures of gas hydrate through spectroscopic identification such as NMR spectroscopy.

  • PDF