• Title/Summary/Keyword: Gas Leakage

Search Result 719, Processing Time 0.033 seconds

Study for Development of Nondestructive Inspection Device in Natural Gas Pipeline Using MFL Technology (MFL을 이용한 천연가스 배관용 비파괴 검사장비 개발에 관한 연구)

  • Cho S.H.;Kim D.K.;Park D.J.;Park S.S.;Yoo H.R.;Koo S.J.;Rho Y.W.;Kho Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.10-16
    • /
    • 2002
  • This paper introduces developed prototype intelligent pig which detects corrosion on pipeline by using Magnetic Flux Leakage technology. The 8 inch developed MFL(Magnetic Flux Leakage) pig is composed of 5 yokes which magnetize pipeline wall and 45 Hall sensors which detect MFL signal. The designed MFL modules are analyzed by using magnetic circuit method in order to confirm whether pipeline wall is fully saturated. A variety of artificial defects are manufactured on 8 inch diameter steel pipeline in order to acquire MFL signals. So leakage flux of the axial, radial and circumferential component was acquired as defects. The results of this paper show that design technique for 8 inch MFL pig can be applied to large diameter MFL pig and 0.5mm defect depth can be detected.

  • PDF

A Study on the Ventilation Schemes for Gas Leakage and Dispersion Controlling at the Backfilled Working Face in Large-Opening Underground Mine (대단면 지하광산 갱도내 뒷채움 작업장 가스유출 및 확산제어 통기방안 연구)

  • Nguyen, Vanduc;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.4
    • /
    • pp.372-386
    • /
    • 2018
  • The air quality near the backfilled site area is significantly deteriorated during and even after the curing period of the backfill materials. Hazardous gases such as NH3 and CO2 may leak out prolongedly from the mined-out sites backfilled with the composite carbonate-based material; leakage can be observed at the underground working sites as well as on the surface. At operating mines, underground gas leakage will severely aggravate the workplace environment. The ventilation schemes should supply sufficient air to dilute the contaminated air, and control the toxic gas leakage and dispersion. This study shows the applicability of pressurization ventilation system to control gas leakage and dispersion at the backfilled underground mine site.

Analysis of Risk Assessment Factors for Gas leakage and Dispersion in Underground Power Plant (지하복합발전플랜트 내의 가스 누출 및 확산에 의한 위험성 평가 인자 분석)

  • Choi, Jinwook;Li, Longnan;Park, Jaeyong;Sung, Kunhyuk;Lee, Seonghyuk;Kim, Daejoong
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.101-106
    • /
    • 2015
  • Gas leakage and dispersion in the underground LNG power plant can lead to serious fire and explosion accident. In this study, computational fluid dynamics simulation was applied to model the dynamic process of gas leakage and dispersion phenomena in a closed space. To analyze the risk assessment factor, such as the flammable volume ratio, transient simulations were carried out for different scenarios. The simulation results visualized the gas distribution with time in the closed space. The flammable volume ratio was introduced for quantitative analysis the fire/explosion probability.

Defect depth estimation using magnetic flux leakage measurement for in-line inspection of pipelines (자기 누설 신호의 측정을 이용한 배관의 결함 깊이 추정)

  • Moon, Jae-Kyoung;Lee, Seung-Hyun;Lee, In-Won;Park, Gwan-Soo;Lee, Min-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.328-333
    • /
    • 2006
  • Magnetic Flux Leakage (MFL) methods are widely employed for the nondestructive evaluation (NDE) of gas pipelines. In the application of MFL pipeline inspection technology, corrosion anomalies are detected and identified via their leakage filed due to changes in wall thickness. The gas industry is keenly interested in automating the interpretation process, because a large amount of data to be analyzed is generated for in-line inspection. This paper presents a novel approach to the tasks of data segmentation, feature extraction and depth estimation from gas pipelines. Also, we will show that the proposed method successfully identifying artificial defects.

A Study on Calculation of Leakage for LPG Explosion Accident using 3D Scan and CFD (3D 스캔과 CFD를 활용한 LPG 폭발사고의 누출량 산정에 관한 연구)

  • Cho, Wan Su;Kim, Eui Soo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.1-7
    • /
    • 2018
  • Recently, various engineering approaches have been widely used in the accident investigation field to identify the cause of the accident and to predict damage by accident. Computational analysis is the most commonly used method of accident investigation technique. This technique is mainly used to identify the mechanism of the accident generation and to determine the cause when it is difficult to reproduce the situation at the time of the accident or when it is impossible to perform a reproduction experiment. In this study, The gas explosion analysis for LPG explosion accident generated by defect of the blocking action was performed to determine the accident object, gas leakage amount and predicted the damage caused by the accident using 3D laser scanner and FLACS program. We can quantify the explosive power by LPG gas accident and predict the gas leakage amount, damage by accident and evaluate the stability of the structure through this study. In the future, This method can be widely used in the field of gas safety by improving the reliability and validity of the analysis.

A Study on a Quality Characteristics of Pressure Leak Test of Process Piping for Offshore Plant (해양플랜트 프로세스 배관 Pressure Leak Test의 품질 특성에 관한 연구)

  • Park, Chang-Soo;Kim, Hyungwoo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.429-437
    • /
    • 2018
  • The process gas piping of the offshore plant can cause a massive explosion if the gas leakage occurs during operation. For the purpose of precaution of gas leakage accident, an air pressure test is performed on the process equipment tests using a test pump as much as the power to the piping inner side, mix 99% nitrogen gas and 1% helium gas. The purpose of the air pressure test is to check the work conformity process by handling and regulation for initial piping process, assembly, installation of module, welding, center alignment of the pipes assembling flange gasket in an unrestrained free state. In this paper, the regulation of the problematic air pressure test was analyzed and the solution criteria were established. And leakage tests of existing equipment were performed applying these solution methods. As a result, it was confirmed that there was no problem.

Analysis for Cause of Corrosion and Gas Leakage on LP-Gas Cylinder (LP가스 용기의 부식 및 가스누출 원인 분석)

  • Choi S. C.;Jo Y. D.;Kweon J. R.;Kim J. Y.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.52-59
    • /
    • 2001
  • Factors to cause accidents were investigated through a systematic analysis of leakage accidents in welded LP-gas cylinder between 199 and 1999. As a result It was showed that most of leakage accident occurred at the pin-hole due to the localized corrosion on welded zone in cylinder. Accordingly, in this paper, we suggested that the problems of heat treatment condition in two-piece welded cylinder and substitute proposal for preventing the tearing of T zone in three-piece welded cylinder. Furthermore, corrosion rate on the weldment and base metal of welded LP-gas cylinder was evaluated using the electrochemical tests in acid rain and $3.5\%NaCl$ solution, Also, the poor adhesion and defects of film which was produced by electrostatic powder spray painting, while the LP-gas cylinder was manufactured, were analyzed using SEM(Scanning Electron Microscopy). And we proposed a optimum coating thickness of the cylinder.

  • PDF

Numerical Analysis of Gas Leakage and Diffusion Behavior in Underground Combined Cycle Power Plant (지하 복합발전 플랜트 내에서의 가스 누출 및 확산 거동에 관한 수치해석 연구)

  • Bang, Joo Won;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.118-124
    • /
    • 2017
  • In this study, a numerical simulation was performed using commercial code Fluent(v.17.1). The underground Combined Cycle Power Plant (CCPP) was simplified to analyze the methane gas leakage with the crack size and position. In addition, extensive numerical simulations were carried out for different crack sizes from 10 mm to 20 mm. The crack position is the gas leakage, which is assumed to be near the pipe elbow and the gas turbine. A total of 4 cases were compared and analyzed. To analyze the gas leakage, the concept of the Lower Flammable Limit (LFL) was applied. The leakage distance was defined in the longitudinal direction, and the transverse direction was estimated and quantitatively analyzed. As a result, the leakage distance in the longitudinal direction varies by 52.3 % depending on the crack size at the same crack position. Moreover, the maximum difference was 34.8 % according to the crack position when the crack sizes are identical. As jet flow impacts on the obstacle and changes its direction, the recirculation flows are formed. These results are expected to provide useful data to optimize the location and number of gas detections in confined spaces, such as underground CCPP.

Fault Tree Analysis for Risk Assessment of CO2 Leakage from Geologic Storage (지중 저장 이산화탄소의 누출 위험도 평가를 위한 결함수 분석)

  • Lee, Sang Il;Lee, Sang Ki;Hwang, Jin Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.359-366
    • /
    • 2009
  • CCS (Carbon Capture and Storage) is considered as the most promising interim solution to deal with the greenhouse gas such as $CO_2$ responsible for global warming. Even though carefully chosen geologic formations are known to contain stored gas for a long time period, there are potential risks of leakage. Up to now, applicable risk assessment procedures for the leakage of $CO_2$ are not available. This study presents a basis for risk analysis applicable to a complex geologic storage system. It starts with the classification of potential leakage pathways. Receptors and the leakage effect on them are identified and quantified. Then, a fault tree is constructed, which yields the minimum cut set (i.e., the most vulnerable leakage pathway) and quantifies the probability of the leakage risk through the cut set. The methodology will provide a tool for risk assessment in a CCS project. The outcomes of the assessment will not only ensure the safety of the CCS system but also offer a reliable and efficient monitoring plan.

Development of Multi Channel Gas Leakage Detector for Large Facility (대규모 시설을 위한 다채널 가스 누설 경보기 개발)

  • Jeong, Kyu-Won
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.1-7
    • /
    • 2008
  • As a clean fuel, LNG or LPG is widely used in large restaurants or plants instead of coal. These fuels are easy to use and cheap. However, they are inflammable very much and easily exploded at the worst. So there are many laws and regulations legislated for the handling and usage of the gas facilities. Nevertheless, very harsh explosions occurred in several domestic or foreign places. In this paper a gas detection and alarm system was developed for large facilities. A new concept for connecting many gas detectors was proposed and based upon that a system including hardware and software have been developed and tested. Although up to 16 gas detectors apart 1 km from main controller can be connected currently, this system can be easily expanded for more detectors because each gas detector receiver communicates with main controller using industrial standard RS-485 multi drop technique. Furthermore several additive functions was included for the installation and maintenance convenience.