Comparison of Ammonia Mass Flow Rate between Two Ammonia Injection Positions in DeNOx system of a Horizontal HRSG (수평형 HRSG의 탈질설비에서 암모니아 분사위치 변동에 따른 암모니아 유량비교)

  • Park, Jae-Hyun;Yoo, Hoseon
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.48-54
    • /
    • 2018
  • As the emission limits for NOx in power generation facilities were strengthened, HRSGs installed in the 1990s became necessary to install additional DeNOx system. However, since there is no space in the HRSG for installing the entire the catalyst and ammonia injection grid, as an alternative, the catalyst was installed inside of the HRSG and the ammonia injection device was installed in the exhaust duct of the gas turbine. Experiments were conducted in horizontal HRSG of Incheon combined cycle power plant. Experimental results show that the ammonia injection method in the gas turbine exhaust duct is 1.2 times higher than the HRSG internal ammonia injection method. However when operating a HRSG for 30 years as its life span, ammonia injection method in the gas turbine exhaust duct is more economical than the cost of new HRSG construction.

  • PDF

A Study on the Reinforcement Plan for the Local Government to Respond to the Climate Change through the Survey of Residents Consciousness - Focused on the Gangnam-gu - (주민 의식 조사를 통한 지자체 기후변화 대응 강화 방안에 관한 연구 - 강남구를 중심으로 -)

  • Choi, Bong Seok;Park, Kyung Eun;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.5 no.1
    • /
    • pp.83-94
    • /
    • 2014
  • Gangnam-gu, where the survey of residents' consciousness has been made in this study, is the district shows the highest rate of the energy consumption and greenhouse gas emission per unit area except some industrial districts such as Gwangyang, Ulsan, and Pohang. The greenhouse gas emission amount of Gangnam-gu is 4,863,765 $tCO_2$ which accounts for 10 % of the total discharging amount of Seoul, 50,330,356 $tCO_2$, which is ranked the top greenhouse gas emission rate in the commercial category and the 2nd place in the household category. The average recognition rate for the 5 subjects of the global warming phenomenons has indicated to be 83.58%. A survey questioning about the main agent to reduce the greenhouse gas, in all age groups except 20s have replied that it should be done by themselves, the residents of Gangnam-gu. For the question of the role of local government to respond to the climate change, the necessity of establishing infrastructure which is suitable for walking and biking. For the other question about the educational facilities to cope with the climate change, many answered the relevant education should be processed from the middle and high schools. For the practical activities in daily life to respond to the climate change, many replies have shown that the energy and resource conservation has been practiced pretty well broadly, but the ecomileage (former carbon mileage) has not been practiced well. Also, many replies have pointed that there were no benefits or rewards for the people who practiced the eco-mileage in their daily lives, which indicates that a kind of incentive is necessary for the efforts to respond to the climate change from the local government to execute the policy substantially and effectively. This study has the purpose to search the political countermeasures to improve the potentiality to reduce the green house gas emission rate through the residents conscious survey about climate change and the political solution by the local government to improve the certain items which showed the lower awareness rate.

Driving Methology for Smart Transportation under Longitudinal and Curved Section of Freeway (스마트교통시대의 종단 및 횡단 복합도로선형 구간에서의 가감속 시나리오별 최적주행 방법론)

  • Yoon, Jin su;Bae, Sang hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.3
    • /
    • pp.73-82
    • /
    • 2017
  • As of December 2016, the number of registered automobiles in Korea exceeds 21million. As a result, greenhouse gas emission by transportation sector are increasing every year. It was concluded that the development of the driving strategy considering the driving behavior and the road conditions, which are known to affect the fuel efficiency and the greenhouse gas emissions, could be the most effective fuel economy improvement. Therefore, this study aims to develop a fuel efficient driving strategy in a complex linear section with uphill and curved sections. The road topography was designed according to 'Rules about the Road Structure & Facilities Standards'. Various scenarios were selected. After generating the speed profile, it was applied to the Comprehensive Modal Emission Model and fuel consumption was calculated. The scenarios with the lowest fuel consumption were selected. After that, the fuel consumption of the manual driver's driving record and the selected optimal driving strategy were compared and analyzed for verification. As a result of the analysis, the developed optimal driving strategy reduces fuel consumption by 21.2% on average compared to driving by manual drivers.

Analysis of Greenhouse Gas Reduction according to Different Scenarios of Zero Food Waste Residential Buildings (음식물류폐기물 제로화 주거단지 구축 시나리오별 비용 및 환경효과 분석)

  • Oh, Jeong-Ik;Yoon, Eun-Joo;Park, Ire;Kim, Yeong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.353-363
    • /
    • 2016
  • In this study, traditional treatment scenario of food wastes that collected and transported food waste is recycled in large treatment facilities and suggested treatment scenario of onsite zero discharge system that food waste is treated in housing complex were supposed. The scenarios were compared and analyzed by capital expenditure, oil consumption, $CO_2$ emission quantity, operating expenditure and management expenses. The capital expenditure, oil consumption and $CO_2$ emission quantity of small scale dispersion dealing method is the lowest compared to traditional treatment method. As a results, it is possible to obtain the effect that operating expenditure was reduced by 91% and management expenses was reduced by 40% with suggested treatment method. The treatment method that have low capital expenditure is tend to lower oil consumption and $CO_2$ emission quantity. The small scale dispersion dealing method have the lowest capital expenditure, oil consumption and $CO_2$ emission quantity and the linked method with sewage treatment have the highest expenditure and $CO_2$ emission quantity. Eventually, the optimal model of onsite zero discharge system in housing complex is small scale dispersion dealing method.

A Survey on Current State of Odor Emission and Control from Livestock Operations (축산농장의 악취 발생과 관리에 관한 실태조사)

  • Kim, Doo-Hwan;Lee, In-Bok;Choi, Dong-Yoon;Song, Jun-Ik;Jeon, Joong-Hwan;Ha, Duk-Min
    • Journal of Animal Environmental Science
    • /
    • v.19 no.2
    • /
    • pp.123-132
    • /
    • 2013
  • This survey was conducted to investigate the current state of odor emission and control from 48 site of Hanwoo, dairy, swine and poultry farms in Korea. On-site complex odors assessment by the method of 6 step direct sensory evaluation and ammonia concentrations by portable gas detector on the boundary line of farms were evaluated and detected as 1.11 & 2.78 ppm, 1.67 & 2.56 ppm, 1.91 & 2.89 ppm, 1.8 & 2.4 ppm and 1.33 & 2.33 ppm, respectively. Almost of Hanwoo, dairy and poultry farms were nothing the complaints occurred for the last 2 years, however as 60% of swine farms were suffered odor complain. All of livestock operations were used the additives for improving the farm environment and spent the considerable costs for odor reduction. There were several plans almost farms, as a fortify maintenance, keep clean, tree planting, expansion facilities for manure treatment or odor reduction.

Evaluating Performance of Energy Conservation Measures for Remodeling Educational Facilities - Focused on Deteriorated Middle School Buildings - (교육시설 리모델링을 위한 에너지 절감 요소기술의 성능 평가 - 노후 중학교 건물 중심으로 -)

  • Lhee, Sang-Choon;Choi, Young-Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.105-110
    • /
    • 2012
  • Recently, all of the world are facing with a serious environmental crisis of global warming due to excessive energy consumptions. The Korean Government, taking over 97% of dependence on foreign energy, has made various efforts on reducing energy and greenhouse gas emission under the motto of "Low-Carbon Green Growth". Since the building sector takes 24% of domestic energy consumption, many design standards and regulations on saving energy in new buildings have been established. However, applications of energy saving designs and techniques on the remodeling process at deteriorated buildings including educational ones have been lack. Under a situation where the number of deteriorated schools accounts for up to 50%, this paper evaluated the performances of factors for reducing energy at deteriorated middle school buildings through an energy simulation tool on a standard school model. As a result, among factors of insulation, window's SHGC, southern louver, indoor setup temperature, and system efficiency, all other factors except window's SHGC and southern louver proved contribute to reduce energy at deteriorated middle school buildings, compared with the baseline energy consumption.

Improving Energy Self-sufficiency in Municipal Wastewater Treatment Plant using Renewable Energy Production (능동적 신재생에너지 생산을 통한 하수처리장 에너지자립화 향상)

  • Kang, Ji-Hoon;Chae, Kyu-Jung;Kim, Dong-Soo;Yang, Hee-Jung;An, Yeong-Seop;Kim, Won-Kyoung;Kim, Jeong-Hyeon;Park, Dong-Eul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.643-643
    • /
    • 2012
  • Increasing energy prices and growing concerns about global warming address the need to improve energy self-sufficiency in many industrial and municipal sectors. Wastewater treatment plants (WWTPs) are representative of energy-consuming facilities in Korea, accounting for 5% of national energy consumption. We present renewable energy technologies and energy self-sufficiency scenarios in a municipal WWTP ($30,000m^3d^{-1}$) located in Yongin, South Korea. By employing photovoltaics (PV, 135 kW), small hydropower turbine (10 kW), and thermal energy from treated effluent (25 RT: refrigeration ton) within the WWTP, a total of 142 tonne of oil equivalent (toe) of energy was estimated to be generated, accounting for $365ton\;CO_2\;yr^{-1}$ of greenhouse gas emission reduction. Core renewable technologies under consideration include 1) hybrid solar PV system consisting of fixed PV, dual-axis PV, and building integrated PV, 2) low-head small hydropower plant specifically designed for treated effluent, 3) effluent heat recovery system for heating and air conditioning. In addition to these core technologies, smart operation and management scheme will be presented for enhancing overall energy savings and distribution within the WWTP.

  • PDF

Research of Efficient Environmental Policy Instruments for the Reduction of SO2-Emissions from Stationary Sources (고정오염원에서 발생하는 SO2 배출량 저감을 위한 효율적인 환경정책수단의 연구)

  • Lee, Yeong Jun
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.339-347
    • /
    • 2004
  • This paper asks the question: what choice of environmental policy instruments is efficient to reduce sulfur dioxide from stationary sources\ulcorner: In Korea, command and control has been a common way of controlling $SO_2-emissions.$ When compared to the non-incentive environmental policy instrument such as command and control, economic incentive environmental policy instrument has been the advantage of making polluter himself flexibly deals with in marginal abatement cost to develop environmental technology in the long view. Therefore, the application possibility of the incentive environmental policy instrument was studied in this research to realize the countermeasure for controlling of $SO_2-emissions.$ As a result, enforcement of the countermeasure such as flue gas desulfurizer by command and control would be suitable because power generation is performed by the public or for the public in source of air pollution and thus, economic principle is not applied to the polluter. In the source of industrial pollution, enforcement of fuel tax is found to be suitable for the countermeasure for the use of low sulfur oil in terms of the flexibility of demand for the price in the long tenn. For the permissible air pollution standards applicable to all air pollutant emitting facilities, enforcement of incentive environmental policy such as bubble, off-set, banking policy or tradeable emission penn its would be ideal in long terms according to the regional characteristics and the number and scale of air pollutant emitting facilities.

A Study on the Environmental Carrying Capacity Assessment of Chongju City (도시 환경용량평가에 관한 연구 -청주시를 사례로-)

  • Lim, Jae-Ho;Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.11 no.1
    • /
    • pp.25-36
    • /
    • 2002
  • The purpose of this study is to assess the environmental carrying capacity of Chongju City for the environmental management and the urban growth management. The urban environmental carrying capacity assessment of the city by the index of ecological footprint(EF), shows that the ecosystem of the city has been overloaded and most of the deficiencies has come from outside of the city. The EF index, the area of land per capita required for production and consumption in the city, was 1.731 ha per capita in 1989 and 1.901 ha per capita in 1999. On the other side, the ecologically productive land is 0.0175 ha per capita. It means that every citizen owes 1.88 ha per capita to the ecosystem in 1999. The land consumption of the city has increased by 0.1705 ha per capita during the last 10 years. The capacity of infrastructure and the service supply estimated by the Onishi model does not exceed the demand of the city in 1999. But the rapidly increasing population and fast urban growth need the expansion of the capacity. The water supply capacity of the city appears to be sufficient in 1999, but the water supply demand will increase in the future. The capacity of sewage treatment facilities seems to be sufficient, but the higher level of sewage treatment facilities should be adopted for the improvement of water quality as the generation of sewage will increase and its characteristics will also make the wastewater treatment difficult. Due to the decrease of solid waste generated, the land fill capacity for solid waste disposal is not insufficient at present, but the capacity will be saturated in the near future. Therefore, the scientific management system of solid wastes should be introduced. The air quality of the city meets both the national air quality standard and WHO recommendation standard, but the strong regulation and control of automobile emission gas such as CO, $CO_2$, NOx and HC is required for clean air.

Radon Removal Efficiency of Activated Carbon Filter from Coconut (코코넛 기반 활성탄 필터의 라돈 제거 효율)

  • Yun-Jin Ahn;Gi-Sub Kim;Tae-Hwan Kim;Sang-Rok Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.