• Title/Summary/Keyword: Gas Discharge

Search Result 1,514, Processing Time 0.028 seconds

Analysis of Insulating Characteristics of Cl2-He Mixture Gases in Gas Discharges

  • Tuan, Do Anh
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1734-1737
    • /
    • 2015
  • Insulating characteristics of Cl2-He mixture gases in gas discharges were analysed to evaluate ability of these gases for using in medium voltage and many industries. These are electron transport coefficients, which are the electron drift velocity, density-normalized longitudinal diffusion coefficient, and density-normalized effective ionization coefficient, in Cl2-He mixtures. A two-term approximation of the Boltzmann equation was used to calculate the electron transport coefficients for the first time over a wide range of E/N (ratio of the electric field E to the neutral number density N). The limiting field strength values of E/N, (E/N)lim, for these binary gas mixtures were also derived and compared with those of the pure SF6 gas.

Analysis on the improvement of Luminous Efficiency by Adding a small amount of Ar Gas in plasma display (PDP에서의 Ar Gas첨가시 효율 개선 경로에 관한 분석)

  • Min, Byeong-Guk;Park, Heon-Geon;Lee, Seok-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.6
    • /
    • pp.483-488
    • /
    • 1999
  • The optimal mixing condition of four components gas(Ne,Xe,He,Ar) in PDPs was caculated by a numerical simulation method. The dominated reactions in which $Xe^*(^3P_1)$ is produced and decays were investigated in three components gas (Ne,Xe,He) and our new components gas (Ne,Xe,He,Ar). A peak point of $Xe^*$ density appears in the range of 0.1% to 2% of Ar mixture ratio. The results of simulation show that the direct exitation of Xe by electrons has the greatest influence on the inceasing $Xe^*$ density in both gas mixtures.

  • PDF

Gas pulsation analysis of large reciprocating compressor in parallel operation (병렬 운전되는 대형 왕복동 압축기의 가스맥동 분석)

  • Kim, Seong-Jun;Kim, Hyun-Cheol;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.910-915
    • /
    • 2009
  • For large reciprocating compressors in parallel operation, an analytical study has been carried out on the gas pulsation in associated discharge piping lines. Since the pressure pulsation at a valve, valve dynamics, and the gas flow rate through the valve are interrelated, affecting one another, these need to be solved simultaneously. Acoustic transfer matrix method, which relates acoustic pressure and velocity at one location to those at another location, has been adopted to calculate the effect of the gas flow at one valve location on the gas pulsation at other valve locations.

  • PDF

Gas Pulsation Analysis of Large Reciprocating Compressors in Parallel Operation (병렬 운전되는 대형 왕복동 압축기의 가스맥동 분석)

  • Kim, Seong-Jun;Kim, Hyun-Jae;Kim, Hyun-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • For large reciprocating compressors in parallel operation, an analytical study has been carried out on the gas pulsation in associated discharge piping lines. Since the pressure pulsation at a valve, valve dynamics, and the gas flow rate through the valve are interrelated, affecting one another, these need to be solved simultaneously. Acoustic transfer matrix method, which relates acoustic pressure and velocity at one location to those at another location, has been adopted to calculate the effect of the gas flow at one valve location on the gas pulsation at other valve locations.

Developement of Gas Detector Dissolved In Transfomer Oil (변압기 절연유중 수소 가스의 검지 시스템 설계)

  • Hwang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.207-210
    • /
    • 2004
  • In oil-filled equipment such as transformers, partial discharge or local overheating will make insulating material(oil, kraft paper, proclain and wood) be stressed and generate many sort of gases($CO,\;CO_2,\;H_2,\;C_2H_4$) which are dissolved in transformer oil. The ratio of this gas can make diagnostic tecchniques of the lifetime of transfomer so, it is important to monitoring $H_2$ gas continuously. This paper developes a system of detecting about $H_2$ gas by using $H_2$ gas sensor, and we describe operation and performance of this system

  • PDF

A Study on the Thrust Throttling Using Gas Injection in Swirl Injectors (기체주입을 이용한 와류형 분사기들에서의 가변추력 연구)

  • Lee, Wongu;Yoon, Youngbin;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.23 no.4
    • /
    • pp.159-168
    • /
    • 2018
  • Thrust throttling in a liquid rocket engine can be implemented via several ways such as high pressure drop injector, dual manifold, multiple chamber, pintle injector, and gas injection. Thrust throttling using gas injection controls thrust by usually injecting inert gas into propellant through an aerator to reduce the propellant's bulk density. In this study, the outside-in aerator was used in the propellant line to create two phase flow. Closed-type, open-type, and screw-type bi-swirl coaxial injectors were utilized for investigating throttling characteristics such as pressure drop, mixture density, and discharge coefficient according to gas-liquid mass ratio.

Electrical Characteristics and Discharge Condition of Ceramic Metal Halide Lamp with Operating Property (구동특성에 따른 세라믹 메탈 할라이드 램프의 전기적 특성 및 방전현상에 관한 연구)

  • Jang, Hyeok-Jin;Kim, Nam-Gon;Yang, Jong-Kyung;Kim, Woo-Young;Park, Hyung-Jun;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.388-389
    • /
    • 2009
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp's properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical characteristics and gas insulation destroy time are analyzed by comparing magnetic ballast with electronic ballast.

  • PDF

A Study on Removal Performance of $NH_3$ Odor Gas Using High Frequency Surface Discharge Body (고주파 연면방전체를 이용한 $NH_3$ 처리성능에 관한 연구)

  • 이주상
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 1996
  • The purpose of this study was to evaluate the decomposition efficiency of $NH_3$ odor gas using high frequency surface discharge body. The results from this study are as follows; 1, Voltage and frequency of electric elements have effects on removal of $NH_3$ odor. The higher these two elements were set up, the more efficiently deodorizing processing worked. In this experiment, the optimum voltage and frequency applicable were observed around AC 6.0 kVp-p and 24.0 kHz respectively. 2. The temperature, humidity and residence time were observed strong variables for NH$_3$ removal process. Its performance had limits at high temperature and humidity conditions. The longer the residence time continued, the more efficiently deodorization process worked. The experimental results showed that the deodorization was efficiently processed under such conditions as $30.0^{\circ}C$ in temperature, 60rh% in humidity and 0.3 sec in residence time. 3. It was observed that in deodorization experiment, $NH_3$ odor gas was perfectly decomposed under the concentration condition below 15.0ppm. Moreover it was considered as economic and practical in terms of maintenance cost when compared with other deodorization methods.

  • PDF

Structural and discharge characteristics of MgO films prepared by Arc Ion Plating (AIP) method

  • Kim, Jong-Kuk;Kim, Do-Geun;Lee, Eun-Sung;Lee, Sung-Hun;Lee, Gun-Hwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.625-627
    • /
    • 2002
  • MgO thin films were deposited on glass and (100) Si substrates by an Arc Ion Plating (AIP) equipment using a magnesium metal target at various oxygen gas flow. In this work, we investigated the relationship between the structural properties and the discharge characteristics of MgO coating layers. X-ray diffraction and AFM have been used to study behaviors of the structure and surface morphology. The optical transmittance and the ion induced secondary electron emission coefficient of the MgO films have been also measured. The resistivity of the deposited MgO films was gradually increased from 0.17 G ohm/${\square}$ to 0.35 G ohm/${\square}$ with the oxygen gas flow. The growth rate of the MgO coating layer was decreased with increasing the oxygen gas flow, while the optical transmittance was improved.

  • PDF

Manufacture and Measurement Uncertainty Analysis of a Venturi Pipe for Airflow Measurement in Altitude Engine Test (엔진 고공 시험에서 공기 유량 측정용 벤투리 파이프의 제작 및 측정 불확도 분석)

  • Yang, In-Young;Oh, Joong-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.36-41
    • /
    • 2010
  • Design, manufacture and calibration procedures of a venturi pipe flowmeter for airflow measurement in altitude engine test were discussed. Altitude engine test using venturi pipe was given as an example. The venturi was designed per the ISO standard of ISO5167, and was intented to include the entire airflow range in the test envelope of the gas turbine engine. Measurement uncertainty analysis was performed in the design procedure to investigate the effect of venturi geometry and sensor specification upon the measurement uncertainty. Manufacturing process was designed to minimize the deviation from the geometry of design. Calibration was performed to get the relationship between the discharge coefficient and the pipe Reynolds number. Then the uncertainty was assessed again using real data acquired during engine test. Through these procedures, it was possible to maintain the uncertainty of airflow measurement under 1 % for most of the operating envelope of the gas turbine engine. The discharge coefficient of the venturi pipe showed agreement with the value suggested in the ISO standard ISO5167-4 within 0.6 %.