• 제목/요약/키워드: Gamma-ray source

검색결과 273건 처리시간 0.028초

Efficiency calibration of a coaxial HPGe detector-Marinelli beaker geometry using an 152Eu source prepared in epoxy matrix and its validation by efficiency transfer method

  • Yucel, Haluk;Zumrut, Senem;Nartturk, Recep Bora;Gedik, Gizem
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.526-532
    • /
    • 2019
  • In this study, an in-house $^{152}Eu$ calibration source was produced from a custom epoxy matrix with a density of ${\rho}=1.14g\;cm^{-3}$, which is chemically stable and durable form after its solidification. The homogeneity of $^{152}Eu$ in matrix was obtained better than 98%. For a Marinelli beaker geometry, an efficiency calibration procedure was applied to a n-type, coaxial, 78.5% relative efficient HPGe detector in the energy range of 121.7-1408.0 keV by using in-house $^{152}Eu$ calibration source. Then the measured efficiencies for Marinelli geometry were compared with the results calculated by MEFFTRAN and ANGLE softwares for the validation. Although MEFFTRAN and ANGLE have two different efficiency transfer algorithms to calculate the efficiencies, they usually need to use a reliable and accurate reference efficiency values as input data. Hence, reference efficiency values were obtained experimentally from a multinuclide standard source for the same detector-Marinelli geometry. In the present source characterization, the corrections required for self-absorption and true coincidence summing effects for $^{152}Eu$ gamma-rays were also obtained for a such close counting geometry condition. The experimental results confirmed the validity of efficiency calculations obtained by MEFFTRAN and ANGLE softwares that are calculation tools.

Luminescence properties and compositions of contaminating inorganic minerals separated from gamma-irradiated fresh and white ginsengs from different areas

  • Ahn, Jae-Jun;Akram, Kashif;Jeong, Mi-Seon;Kwak, Ji-Young;Park, Eun-Joo;Kwon, Joong-Ho
    • Journal of Ginseng Research
    • /
    • 제37권4호
    • /
    • pp.483-490
    • /
    • 2013
  • Gamma-irradiation (0-7 kGy) of ginseng is permitted in Korea for the purpose of microbial decontamination; with strict labeling, traceability and monitoring requirements. An identification study was conducted to determine the photostimulated-luminescence (PSL) and thermoluminescence (TL) properties of gamma-irradiated fresh and white ginsengs cultivated in different areas. Dose- dependent PSL-based screening was possible for white ginseng samples; however, inappropriate results from non-irradiated fresh ginseng samples were obtained, showing intermediate (700 to 5,000) or positive ($T_2$ >5,000, irradiated) PSL counts due to the abundance of minerals on the surfaces of the samples. TL analysis of separated minerals from all non-irradiated samples gave TL glow curves of low intensity with a maximum peak after $300^{\circ}C$. However, well-defined irradiation-specific (high intensity with a maximum peak at about $200^{\circ}C$) glow curves were observed for all the irradiated samples, regardless of their type and origins. TL ratios (first glow curve /second glow curve) were also determined to confirm the irradiated (>0.1) and non-irradiated (<0.1) results. SEM-EDX (scanning electron microscope-energy dispersive X-ray) and XRD (X-ray diffraction) spectroscopic analyses showed that feldspar and quartz minerals were the main source for the typical radiation-specific luminescence properties.

안티몬 차폐시트의 감마선 차폐 성능평가 (Performance Evaluation of Gamma ray Shielding of Antimony Shielding Sheet)

  • 한상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.135-140
    • /
    • 2018
  • In this study, the dose of antimony shielding sheet was measured and the shielding rates according to the distance between the radioisotopes and the detector was analyzed according to the type of $^{99m}Tc$, $^{18}F$, $^{201}Tl$, $^{131}I$, $^{123}I$ using the antimony shielding sheet. The detector was used with an inspector. Six sheets of 0.25 mmPb were prepared with 20 cm width and length. Measurement results using $^{99m}Tc$, $^{201}Tl$, and $^{123}I$ showed that as the thickness of the sheet became thicker, the farther the distance from the source to the sheet was, the smaller the transmitted dose amount was measured. It was analyzed that a thickness of 1.50 mm or more was required to obtain a shielding rates of 90% or more. In the experiments of $^{18}F$ and $^{131}I$, the dose value was highest when 0.25 mm sheet was used, and the shielding rates was negative, unlike the results of other radioisotopes. Since $^{201}Tl$ are used when using antimony sheet and $^{18}F$ and $^{131}I$ have no shielding effect, it is thought that it is effective to reduce dose by repeating training and simulation training so that work can be done in a short time.

Multifrequency polarization monitoring of a blazar 3C279

  • Kang, Sincheol;Lee, Sang-Sung;Byun, Do-Young;Han, Myounghee
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.60.1-60.1
    • /
    • 2014
  • In the center of an Active Galactic Nuclei(AGN) is a supermassive black hole which accretes matter from its surroundings. The radio-loud AGN launch two relativistic jets perpendicular to the accretion disk which terminates into radio lobes located up to megaparsec away. Blazars form a small subset of radio-loud AGNs with one of two relativistic jets pointing toward the observer's line of sight. Many blazars often show flares at different frequencies. And these flares at different frequencies are known that they often correlate with each other. In 2013 December, there was a gamma-ray flare in 3C 279, one of the brightest blazars, Dec 2013. So we want to reveal that whether this flare correlates with radio flare or not, and where the flare originate. With polarization observation at radio frequencies, we can study the physical properties of the magnetic field in the innermost regions of the relativistic jets. Therefore, we have conducted polarization monitoring of this source from Dec. 2013 to Jun. 2014 with KVN(Korea VLBI Network) radio telescopes at 22, 43 and 86GHz. Here we present the initial results of the monitoring of 3C 279. We prospect that we can reveal the origin of this gamma-ray flare by comparing with our radio data.

  • PDF

EXPERIMENTAL VALIDATION OF THE BACKSCATTERING GAMMA-RAY SPECTRA WITH THE MONTE CARLO CODE

  • Hoang, Sy Minh Tuan;Yoo, Sang-Ho;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • 제43권1호
    • /
    • pp.13-18
    • /
    • 2011
  • In this study, simulations were done of a 661.6 keV line from a point source of $^{137}Cs$ housed in a lead shield. When increasing the scattering angle from 60 to 120 degrees with a 6061 aluminum alloy target placed at angles of 30 and 45 degrees to the incident beam, the spectra showed that the single scattering component increases and that the multiple scattering component decreases. The investigation of the single and multiple scattering components was carried out using a MCNP5 simulation code. The component of the single Compton scattering photons is proportional to the target electron density at the point where the scattering occurs. The single scattering peak increases according to the thickness of the target and saturates at a certain thickness. The signal-to-noise ratio was found to decrease according to the target thickness. The simulation was experimentally validated by measurements. These results will be used to determine the best conditions under which this method can be applied to testing electron densities or to assess the thickness of samples to locate defects in them.

우리별 1호에서의 총 방사선 측정 실험 (RESULTS OF THE TOTAL DOSE EXPERIMENT ON KITSAT-1)

  • 이대희;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • 제14권1호
    • /
    • pp.80-86
    • /
    • 1997
  • 지구 주변의 방사선대에 존재하는 고에너지 입자들은 위성계의 전자 재료, 부품, 및 집적 회로 등에 일시적 또는 장기적인 영향을 준다. 따라서 이러한 고에너지 입자들에 의한 우주 방사선 환경에 대한 정보를 아는 것은 매우 중요하다. 총 방사선의 양을 측정하는 장치로서 MOSFET을 개량한 RADFET을 많이 사용하는데, 본 연구에서는 $Co^{60}{\gamma}-ray$를 이용하여 TOT500 RADFET을 보정하였다. 그 결과, 방사선에 대한 RADFET의 특성 곡선 변화가 온도의 변화에 매우 민감한 것을 확인하였다. 또한, 우리별 1호에서의 TDERUF과를 위성의 온도와 비교하였으며, 그 결과 TDE 실험에 나타난 특이한 형상은 지구에 의한 위성의 식 현상에서 비롯된 온도 변화가 주된 원인이었음을 확인하였다.

  • PDF

코발트-60 감마선의 전자 오염에 관한 연구 (Study on the Reduction of Electron Contamination with A Cobalt-60 Gamma Ray)

  • 김태규;전하정;이명자
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.293-297
    • /
    • 1989
  • Electron contamination due to the interaction between radiation beam and material was analyzed for the factors such as source-skin distance (SSD), field size, tray characteristics and position of filter, which can affect the surface dose in Cobalt teletherapy. Surface dose in open beam was more influenced by SSD with increasing field size. Relative surface charge (RSC) increased with the use of tray (solid, circular hole, slotted), compared with open beam, which is thought to be due to increased electron contamination of the tray. To reduce the surface dose, 0.4mm thick Lipowitz metal filter was used. Compared with open beam, RSC decreased by 8.8%, 11.3%, 13.3%, 16.6%, 19.3% and 21.7% for the field size of $5{\times}5$, $10{\times}10$, $15{\times}15$, $20{\times}20$, $25{\times}25$ and $30{\times}30cm^2$, respectively. On the contrary, use of Lipowitz metal filter increased RSC at 60cm or less SSD. Surface dose was effectively reduced with Lpowitz metal filter placed right below solid tray in Cobalt teletherapy.

  • PDF

Development of gamma ray scanning coupled with computed tomographic technique to inspect a broken pipe structure inside laboratory scale vessel

  • Saengchantr, Dhanaj;Srisatit, Somyot;Chankow, Nares
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.800-806
    • /
    • 2019
  • This paper presents a laboratory experiment on data acquisition technique that applied to the gamma radiation scanning coupled with computed tomography (CT) technique for inspection of broken nozzle inside the vertical vessel. The acquisition technique was developed to inspect a large diameter vessel when suspicious problem location is not easily accessed. This technique allows the installation of gamma radiation source (Cesium 137, Cs-137), and detectors (Sodium Iodine. NaI(Tl)) from the accessible location to the required location and performs the scanning by designed pattern. To demonstrate the designed technique, top opened tank which installed with six cut steel pipes diameter of 76.2 mm (3") at a certain position was selected. They were assumed to be a gas riser pipes inside the vessel. Three studied cases were performed, (a) projection of well installed six pipes, (b) projection of one out of six broken pipe and (c) one of nozzle was assumed to be failure and fell down until one out of six pipes was broken and obstructed by nozzle. Results clearly indicated the capability of developed technique to distinguish between normal situation case and abnormal situation cases.

Novel polyvinyl alcohol film dosimeter containing 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide dye for high dose application

  • Khalid A. Rabaeh;Ahmed A. Basfar;Issra' M.E. Hammoudeh
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3383-3387
    • /
    • 2023
  • A new dyed polyvinyl alcohol (PVA) film dosimeter based on 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MMT) tetrazolium dye is proposed in this study for measuring high gamma radiation dose. Gamma cell irradiator that contains Co-60 gamma-ray source was used to expose the novel MMT-PVA films to different doses up to 25 kGy. The changed in optical property of irradiated and unirradiated films were characterized by UV-Vis spectrophotometer. The results show that the dose sensitive and the linear range of irradiated films were increased considerably with increase of MMT concentration from 1 to 5 mM. The dose response of dyed PVA film changed substantially with changing relative humidity (12-74%) as well as irradiation temperature (10-40 ℃). The absorbance of the unirradiated films does not change up to 10 days in dark while a significant increase in their absorbance was reported for similar films under fluorescent light. The irradiated dosimeters that kept in dark showed a perfect stability for 54 days. It was found that no obvious impact of dose rate on the irradiated MMT-PVA film dosimeters.

밀도검층 이격 보정을 위한 기준선과 이격선의 특성 연구 (A Study on Spine and Rib Properties for Standoff Compensation, Density Log)

  • 김영화;김종만
    • 지구물리와물리탐사
    • /
    • 제15권4호
    • /
    • pp.190-198
    • /
    • 2012
  • 밀도가 알려진 4개의 모형시험공에서 이격실험을 하고 얻어진 비이격 및 이격 측정 자료를 분석함으로서 기준선과 이격선의 특성을 파악할 수 있었다. 특히 선원을 출발하여 검출기에 도달하기까지의 감마선 경로의 형태, 기준선과 이격선의 궤적 특성, 궤적에 미치는 밀도 및 검출기 조합의 영향을 추적할 수 있었으며 이격보정을 위한 최적의 검출기 조합까지 확인할 수 있었다. 기준선과 이격선의 기울기 모두 검출기 조합별 긴거리와 짧은거리 간의 선원-검출기 거리비에 비례하는 함수의 형태로 표시될 수 있음을 확인하였다. 이 연구는 기준선 및 이격선의 기울기에 대한 기본 개념 이해에도 효과적으로 적용되었다.