Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

Monte Carlo simulation of spatial resolution of lens-coupled LYSO scintillator for intense pulsed gamma-ray imaging system with large field of view

  • Guoguang Li;Liang Sheng;Baojun Duan;Yang Li;Dongwei Hei;Qingzi Xing
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2650-2658
    • /
    • 2024
  • In this paper, we use a Monte Carlo (MC) simulation based on Geant4 to investigate the influence of four parameters on the spatial resolution of the lens-coupled lutetium yttrium orthosilicate (LYSO) scintillator, including the thickness of the LYSO scintillator, the F-number and minification factor of the lens, and the incident position of the gamma-rays. Simulation results show that when the gamma-rays are incident along the lens axis, the smaller the thickness, the larger the F-number, the larger the minification factor, the higher the spatial resolution, with an isotropic point spread function (PSF). As the incident position of the gamma-rays deviates from the lens axis, the spatial resolution decreases, and the PSF becomes anisotropic. In addition, by analyzing the whole physical process of the lens-coupled LYSO scintillator from gamma-rays to secondary electrons to fluorescence photons, we aim to provide a detailed analysis of the influence of each parameter on the spatial resolution. The results show that the PSF of the secondary electrons energy deposition is almost constant in the simulation, which determines the upper limit of the spatial resolution. Meanwhile, the dispersion process of the fluorescence photons can explain the reason why each parameter affects the spatial resolution.

영상처리기반 감마선원 거리탐지 고속화 및 가시화 연구 (The Visualization and the Fast Detection of Gamma Radiation Source using Stereo Image Processing)

  • 황영관;이남호
    • 한국정보통신학회논문지
    • /
    • 제20권10호
    • /
    • pp.2001-2006
    • /
    • 2016
  • 감마선 공간 탐지 장치는 감마선원을 스캔하여 영상화 한 후 스테레오 영상처리기술을 적용하여 탐지선원까지의 거리를 측정한다. 또한 실제 공간의 방사선원에 대한 분포 정보를 제공해 준다. 본 논문에서는 감마선 탐지장치가 3차원 공간상에서 장치로부터 선원을 찾기 위해 스캔하는 탐지 시간을 단축 시킬 수 있도록 감마선 탐지 고속화 알고리즘을 구현하였다. 그리고 감마선 조사 시험장에서 실험을 통해 그 성능을 검증하였다. 탐지시험 결과 고속 탐지를 위한 알고리즘을 적용할 경우 단일선원을 탐지할 경우 좌 우 스테레오 영상 획득 시보다 약 35% 의 탐지 시간을 단축시킬 수 있음을 확인하였다. 또한 사용자에게 방사선 공간분포 정보를 효율적으로 전달하기 위한 감마선원 분포의 입체 가시화를 구현하여 방사선원에 대한 정보를 제공할 수 있도록 하였다.

PRELIMINARY FEASIBILITY STUDY OF THE SOLAR OBSERVATION PAYLOADS FOR STSAT-CLASS SATELLITES

  • Moon, Yong-Jae;Cho, Kyung-Seok;Jin, Ho;Chae, Jong-Chul;Lee, Sung-Ho;Seon, Kwang-Il;Kim, Yeon-Han;Park, Young-Deuk
    • Journal of Astronomy and Space Sciences
    • /
    • 제21권4호
    • /
    • pp.329-342
    • /
    • 2004
  • In this paper, we present preliminary feasibility studies on three types of solar observation payloads for future Korean Science and Technology Satellite (STSAT) programs. The three candidates are (1) an UV imaging telescope, (2) an UV spectrograph, and (3) an X-ray spectrometer. In the case of UV imaging telescope, the most important constraint seems to be the control stability of a satellite in order to obtain a reasonably good spatial resolution. Considering that the current pointing stability estimated from the data of the Far ultraviolet Imaging Spectrograph (FIMS) onboard the Korean STSAT-1, is around 1 arc minutes/sec, we think that it is hard to obtain a spatial resolution sufficient for scientific research by such an UV Imaging Telescope. For solar imaging missions, we realize that an image stabilization system, which is composed of a small guide telescope with limb sensor and a servo controller of secondary mirror, is quite essential for a very good pointing stability of about 0.1 arcsec. An UV spectrograph covering the solar full disk seems to be a good choice in that there is no risk due to poor pointing stability as well as that it can provide us with valuable UV spectral irradiance data valuable for studying their effects on the Earth's atmosphere and satellites. The heritage of the FIMS can be a great advantage of developing the UV spectrograph. Its main disadvantage is that two major missions are in operation or scheduled. Our preliminary investigations show that an X-ray spectrometer for the full disk Sun seems to be the best choice among the three candidates. The reasons are : (1) high temporal and spectral X-ray data are very essential for studying the acceleration process of energetic particles associated with solar flares, (2) we have a good heritage of X-ray detectors including a rocket-borne X-ray detector, (3) in the case of developing countries such as India and Czech, solar X-ray spectrometers were selected as their early stage satellite missions due to their poor pointing stabilities, and (4) there is no planned major mission after currently operating Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI) mission. Finally, we present a preliminary design of a solar X-ray spectrometer covering soft X-ray (2 keV) to gamma ray (10 MeV).

Combined X-ray CT-SPECT System with a CZT Detector

  • Kwon, Soo-Il;Koji Iwata;Hasegawa, B-H
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.379-381
    • /
    • 2002
  • A single CdZnTe detector is tested for suitability in a prototype CT/ SPECT system designed to acquire both emission and transmission data. The detector has the size of 1${\times}$l-cm$^2$ with 4${\times}$4 1.5${\times}$l.5mm$^2$ pixellated anodes. Since the detector is smaller than imaged object, we translated it in an arc centered at the x-ray tube to image larger objects. Pulse counting electronics with very short shaping time (50 ns) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3${\times}$10$\^$5/ counts per second per detector element is achieved. The energy resolution of 122-keV gamma-ray is measured to be 14%. We have characterized the system performance by scanning a radiographic resolution phantom .and the Hoffman brain phantom. The spatial resolution of CT and SPECT are about 1 mm and 7 mm, respectively.

  • PDF

CZT검출기를 이용한 CT/SPECT 조합영상시스템 (Combined X-ray CT/SPECT System with a Common CZT Detector)

  • 권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.229-233
    • /
    • 2002
  • CdZnTe 검출기를 제작하고 CT/SPECT 조합영상 시스템에 설치하여 엑스선 및 감마선검출기로서의 응용가능성을 타진해 보았다. 검출기의 크기는 10$\times$10$\times$5 ㎣ 이었다. 양극은 4$\times$4 픽셀로 설계하였으며 각 픽셀의 크기는 $1.5\times$l.5 $\textrm{mm}^2$ 이었다. 음극은 Au로 전극을 만들어 주었다. 시스템의 성능을 조사하기 위해서 방사선촬영용 분해능팬텀과 호프만 뇌 팬텀을 사용하였다. X선 영상에서 고광자방출율을 만족시키기 위해서 shapping time은 50ns 로 하었으며, 3$\times$$10^{5}$ counts/s 까지 선형성이 유지되었다. Tc-99m의 140 keV 감마선에 대한 에너지 분해능은 50 ㎱와 2 $\mu\textrm{s}$ shaping time을 걸어주었을 때 각각 10.4%와 5.3%이었다. CT와 SPECT의 공간분해능은 각각 1 mm와 9 mm 이었다. 광피이크 효율은 50 ㎱와 2 $\mu\textrm{s}$일 때 각각 41.0%와 72.5%이었다.

  • PDF

휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발 (Development of a Portable Device Based Wireless Medical Radiation Monitoring System)

  • 박혜민;홍현승;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.150-158
    • /
    • 2014
  • 각 의료기관 내 방사선 관련 종사자나 방사선 치료환자들은 진단 및 치료 시 필연적으로 의료상 피폭을 수반하게 된다. 국제방사선방호위원회(ICRP) 권고나 국제원자력기구(IAEA)의 기준에 따라 기준선량 제약치를 적용 및 권고 받고 있지만 1차 피폭대상자인 종사자나 환자들의 피폭최적관리를 위해서는 잠재적인 피폭대상자들에게 기존의 피폭관리 시스템보다 직접적이고 가용성이 높은 측정 및 분석 방법이 필요하다. 따라서 본 연구에서는 기존에 구비된 휴대용 단말과 연동하여 원거리에서 실시간으로 방사선 모니터링이 가능한 시스템을 개발하였다. 모니터링 시스템은 검출부, 영상부, 통신부 세 부분으로 구성되었다. 검출부는 시스템의 소형화를 위해 실리콘 광증배소자(silicon photomultiplier) 기반 섬광검출기를 설계하였으며, 영상부는 무선 CCD (charge-coupled device)카메라 모듈을 사용하여 검출부와 함께 Bluetooth 통신모듈을 통해 휴대용 단말로 측정된 방사선 정보와 영상이 전송된다. 제작된 시스템은 성능 평가를 위해 진단용 X-ray 발생장치와 $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, $^{90}Sr$ 선원을 사용하였다. 측정결과를 통해 개발된 시스템은 gamma, beta, X-ray에 대해서 검출 반응성을 확인하였고, 방사선 세기에 따른 응답 선형성과 MCNPX 전산코드를 이용한 측정 거리에 따른 시스템의 검출 정확도 평가 시 3% 내외의 오차범위를 확인하였다. 본 연구의 결과는 방사선 검출 시스템 구성의 비용절감 효과와 개인피폭정도관리에 기여할 것으로 기대한다.

POLARIZATION AND POLARIMETRY: A REVIEW

  • Trippe, Sascha
    • 천문학회지
    • /
    • 제47권1호
    • /
    • pp.15-39
    • /
    • 2014
  • Polarization is a basic property of light and is fundamentally linked to the internal geometry of a source of radiation. Polarimetry complements photometric, spectroscopic, and imaging analyses of sources of radiation and has made possible multiple astrophysical discoveries. In this article I review (i) the physical basics of polarization: electromagnetic waves, photons, and parameterizations; (ii) astrophysical sources of polarization: scattering, synchrotron radiation, active media, and the Zeeman, Goldreich-Kylafis, and Hanle effects, as well as interactions between polarization and matter (like birefringence, Faraday rotation, or the Chandrasekhar-Fermi effect); (iii) observational methodology: on-sky geometry, influence of atmosphere and instrumental polarization, polarization statistics, and observational techniques for radio, optical, and $X/{\gamma}$ wavelengths; and (iv) science cases for astronomical polarimetry: solar and stellar physics, planetary system bodies, interstellar matter, astrobiology, astronomical masers, pulsars, galactic magnetic fields, gamma-ray bursts, active galactic nuclei, and cosmic microwave background radiation.

3차원 정보 제공을 위한 X-선 검색장치의 기하학적 모델링 (The Geometric Modeling for 3D Information of X-ray Inspection)

  • 이흥호;이승민
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1151-1156
    • /
    • 2013
  • In this study, to clearly establish the concept of a geometric modeling I apply for the concept of Pushbroom, limited to two-dimensional radiation Locator to provide a three-dimensional information purposes. Respect to the radiation scanner Pushbroom modeling techniques, geometric modeling method was presented introduced to extract three-dimensional information as long as the rotational component of the Gamma-Ray Linear Pushbroom Stereo System, introduced the two-dimensional and three-dimensional spatial information in the matching relation that can be induced. In addition, the pseudo-inverse matrix by using the conventional least-squares method, GCP(Ground Control Point) to demonstrate compliance by calculating the key parameters. Projection transformation matrix is calculated for obtaining three-dimensional information from two-dimensional information can be used as the primary relationship, and through the application of a radiation image matching technology will make it possible to extract three-dimensional information from two-dimensional X-ray imaging.

Sentinel lymph node mapping using tri-modal human serum albumin conjugated with visible dye, near infrared fluorescent dye and radioisotope

  • Kang, Se Hun;Kim, Seo-il;Jung, So-Youn;Lee, Seeyoun;Kim, Seok Won;Kim, Seok-ki
    • 대한방사성의약품학회지
    • /
    • 제1권1호
    • /
    • pp.62-73
    • /
    • 2015
  • We developed an evans blue-indocyanine green-$^{99m}Tc$-human serum albumin conjugate for sentinel lymph node mapping and we describe its unique potential usage for clinical implications. This conjugate has combined the strengths of visible blue dye, near-infrared fluorescence and radioisotope into one single conjugate without any additional weakness/disadvantage. All the components of evans blue-indocyanine green-$^{99m}Tc$-human serum albumin are safe and of low cost, and they have already been clinically used. This conjugate was stable in the serum, it showed a long retention time in the lymphatic system and the lymph nodes showed a much higher signal-to-noise ratio after the conjugate was injected intradermally into the paw of mice. Both the single-photon emission computed tomography and near-infrared fluorescent images of the mice were successfully obtained at the same time as the excised sentinel lymph nodes showed blue color. The visual color, near-infrared fluorescence and gamma ray from this agent could be complementary for each other in all the steps of sentinel lymph node sampling: exploring and planning sentinel lymph node before excision with visualization of the exact sentinel lymph node location during an operation. Therefore, the triple modal agent will possibly be very ideal for sentinel lymph node mapping because of the high signal-to-noise ratio for non-invasive imaging and its complementary multimodal nature, easy preparation and safety. It is promising for clinical applications and it may have great advantages over the traditional single modal methods.