• Title/Summary/Keyword: Gamma-ray Spectroscope

Search Result 4, Processing Time 0.022 seconds

Development of One-channel Gamma ray spectroscope for Automatic Radiopharmaceutical Synthesis System (방사성 의약품 자동합성장치용 단채널 감마선 분광기 보드의 설계 및 제작)

  • Song, Kwanhoon;Kim, Kwangsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.193-200
    • /
    • 2014
  • In this paper, the prototype of one-channel gamma-ray spectroscope for automatic radiopharmaceutical systhesis system was designed and characterized. The prototype employed CZT (CdZnTe) spear detector for gamma-ray detection and employed analog-type signal processing method. A radioactive sample Co-60 was used for measuring performance of the gamma-ray spectroscope and energy spectrum is gained with bandwidth of 1173keV. The analog board is made up of SF (shaping filter) and PHA (peak and hold amplifier) for shaping CZT output signal appropriately and ADC (analog to digital converter) and FPGA (field programmable gate array) for drawing gamma-ray spectrum by counting the digitalized gamma-ray signal data.

A Study on the Fabrication and Detection of Cd$_{80}$ Zn$_{20}$Te Gamma-ray detector with MIM Structure (Cd$_{80}$ Zn$_{20}$Te를 사용한 MIM 구조의 감마선 탐지 소자 제작 및 탐지 특성에 관한 연구)

  • 최명진;왕진석
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.4
    • /
    • pp.47-53
    • /
    • 1997
  • We fabricated gamma radiation detector using high resistive p-Cd$_{80}$Zn$_{20}$Te grown by high pressure bridgman method and forming au thin film electrode by chemically electroless deposition method. The device of Au/Cd$_{80}$Zn$_{20}$Te/Au is a typical MIM structure. The characteristic of current-voltage showed good linearity to 3kV/cm but it depend on the square of electric field over 3kV/cm. As the results of rutherford backscattering spectroscope(RBS) and auger spectroscope on the Au/Cd$_{80}$Zn$_{20}$Te, Au penetrated to the surface of Cd$_{80}$Zn$_{20}$Te detector absorbed slightly high energy radiation like a few hundred keV and showed good performance to detect low energy gamma ray.mma ray.

  • PDF

The wettability of Sn-Xwt%Cu solder (Sn-Xwt%Cu 솔더의 젖음성에 관한 연구)

  • Lee, Jong-Beom;No, Bo-In;Jeong, Seung-Bu
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.199-201
    • /
    • 2006
  • The wetting balance test was carried out to compare the wettability of Sn-Xwt%Cu($0{\sim}3$wt%) solders. And, IMCs which were formed at interface between solders and substrates were investigated by using XRD(x-ray diffractometer), SEM(scanning electron microscope) and EDS(energy dispersive spectroscope). The value of ${\gamma}_[fl}$ and(${\gamma}_{fs}-{\gamma}_{ls}$) had a tendency to increase with increasing wetting temperature. The activation energy that was calculated between the bare Cu substrate and flux was increased in the following order Sn-0.7wt%Cu(68.42 kJ/mol);Sn-3.0wt%Cu(72.66 kJ/mol);100wt%Sn solder(94.53 kJ/mol).

  • PDF

Geostatistical Interpretation of Cs-137 and K-40 Result of the Lithosphere in the Vicinity of Youngkwang Nuclear Power Plant (지구통계학적 방법에 의한 영광원전주변 토층내 Cs-137 및 K-40 측정 결과의 해석)

  • 김경웅;이재석;문승현;박철승;고일원;고은정;조병옥;정철영;전수열
    • Economic and Environmental Geology
    • /
    • v.35 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • In order to investigate the influence of nuclear power plant operation on its nearby environment, soil, stream and marine sediment samples were collected in the vicinity of the Youngkwang Nuclear Power Plant in Korea, and analyzed for artificial and natural radionuclide radioactivity. From the analytical result, Cs-137 was detected in most soil samples. but it may have been derived fiom past nuclear weapon tests because Cs-134 having short half-live was not detected. The radioactivities of Cs-137 in the sediment samples were also detected which are within the normal range in the sediments based upon the published literature between 1997 and 1999. For the quality control of radioactivity analysis of environmental samples, sets of marine sediments in the Gamami area were analyzed using two HPGe Gamma-ray Spectroscopes (30% and 45%) according to the geostatistical sampling strategy, and Cs-137 and K-40 results were interpreted by analysis of variance (ANOVA). In the two-way ANOVA, variances derived from the geochemical variation were significant, but errors from sampling and analytical procedures are negligible. In conclusion. all the radioanalytical procedures of this study including sampling are validated to be acceptable.