• Title/Summary/Keyword: Gamma spectra

Search Result 264, Processing Time 0.027 seconds

Characteristics of Thermally Stimulated Current in the ZnO varister (ZnO 바리스터의 TSC 특성)

  • 안용모;이성일;이상석;박춘배;이준용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1989.06a
    • /
    • pp.101-104
    • /
    • 1989
  • Thermal Electet of the Zinc Oxide varistor has been studied in the temperature range of -130~200[$^{\circ}C$] and the electric field of 6[kV/m]. It appears that there are four peaks of thermally stimulated current; $\alpha$, $\beta$, ${\gamma}$ and $\delta$ spectra appearing at the temperature range of 160, 130, 20 and -30[$^{\circ}C$], respectively. It seems that the origin of $\alpha$, $\beta$, ${\gamma}$ and $\delta$ peaks are associated with the depolarization of donor ions in the depletion layer, the detrapping of trapped electron in the surface, the detrapping of trapped electron in the donor level and the detrapping of trapped electron between grain and intergranular, respectively.

  • PDF

SYNTHESIS OF SILICA-COATED Au WITH Ag, Co, Cu, AND Ir BIMETALLIC RADIOISOTOPE NANOPARTICLE RADIOTRACERS

  • Jung, Jin-Hyuck;Jung, Sung-Hee;Kim, Sang-Ho;Choi, Seong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.971-976
    • /
    • 2012
  • Silica-coated Au with Ag, Co, Cu, and Ir bimetallic radioisotope nanoparticles were synthesized by neutron irradiation, after coating $SiO_2$ onto the bimetallic particles by the sol-gel St$\ddot{o}$ber process. Bimetallic nanoparticles were synthesized by irradiating aqueous bimetallic ions at room temperature. Their shell and core diameters were recorded by TEM to be 100 - 112 nm and 20 - 50 nm, respectively. The bimetallic radioisotope nanoparticles' gamma spectra showed that they each contained two gamma-emitting nuclides. The nanoparticles could be used as radiotracers in petrochemical and refinery processes that involve temperatures that would decompose conventional organic radioactive labels.

Thermal Electret of the ZnO varistor (ZnO 바리스터의 열 일렉트렛트)

  • Ahn, Y.M.;Lee, S.S.;Park, S.H.;Hong, J.W.;Lee, S.P.;Lee, J.U.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.817-820
    • /
    • 1988
  • Thermal Electet of the Zinc Oxide varistor has been studied in the temperature range of -130${\sim}200[^{\circ}C]$ and the electric field of 6[kV/m]. It appears that there are four peaks of thermally stimulated current; ${\alpha},\;{\beta},\;{\gamma}$ and ${\delta}$ spectra appearing at the temperature range of 160, 130, 20 and $-30[^{\circ}C]$, respectively. It seems that the origins of ${\alpha},\;{\beta},\;{\gamma}$ and ${\delta}$ peaks are associated with the depolarization of donor ions in the depletion layer, the detrapping of trapped electron in the surface, the detrapping of trapped electron in the donor level and the detrapping of trapped electron between grain and intergranular, respectively.

  • PDF

Surface-enhanced Raman Spectroscopy of Ethephone Adsorbed on Silver Surface

  • Lee, Chul-Jae;Kim, Hee-Jin;Karim, Mohammad Rezaul;Lee, Mu-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.545-548
    • /
    • 2006
  • We investigated the Surface-enhanced Raman Spectroscopy (SERS) spectrum of ethephone (2-chloroethylphosphonic acid). We observed significant signals in the ordinary Raman spectrum for solid-state ethephone as well as when it was adsorbed on a colloidal silver surface, strong vibrational signals were obtained at a very low concentration. The SERS spectra were obtained by silver colloids that were prepared by the $\gamma$-irradiation method. The influence of pH and the influence of anion $(Cl^-,\;Br^-,\;I^-)$ on the adsorption orientation were investigated. Two different adsorption mechanisms were deduced, depending on the experimental conditions. The chlorine atom or the chlorine and two oxygen atoms were adsorbed on the colloidal silver surface. Among halide ions, $Br^-$ and $I^-$ were more strongly adsorbed on the colloidal silver surfaces. As a result, the adsorption of ethephone was less effective due to their steric hinderance.

Effects of Electron-Beam Irradiation on Color and Organoleptic Qualities of Ginseng Powders (Electron Beam 조사가 인삼분말의 색도 및 관능적 품질에 미치는 영향)

  • Lee, Mi-Gyeong;Gwon, Jung-Ho;Do, Jae-Ho
    • Journal of Ginseng Research
    • /
    • v.22 no.4
    • /
    • pp.252-259
    • /
    • 1998
  • Electron beam, electrically produced from an electron accelerator, was compared with gamma energy in terms of its influence on color and organoleptic qualities of ginseng powders when exposed to the energy used for their microbial decontamination. Hunter color L and b values were suitable for measuring color characteristics of ginseng powders, which were not significantly changed by the exposure to 5 to 7.5 kGy electron beam and gamma energy. Fifty percent ethanol extracts of irradiated ginseng powders at 10 key showed negligible differences from the non-irradiated control in the pattern of absorption spectra at 280∼800 am, but showed increased values in overall color difference (AE) as compared with powdered samples. Irradiation more than 10 kGy and storage at ambient temperature for 4 months caused browning of powdered samples. Irradiation at more than 10 kGy of electron beam was found a critical level to bring about appreciable changes (p<0.05) in or-ganoleptic qualities such as color and odor of sterilized samples, and red ginseng powder was more susceptible than white one to organoleptic changes by irradiation.

  • PDF

Development of Spectroscopy Toolkit for Spectrum Measurement Experiments Using a CsI(Tl)/PIN Diode Detector

  • Nam, Young-Mi;Kim, Han-Soo;Ha, Jang-Ho;Lee, Jae-Hyung
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.77-80
    • /
    • 2010
  • The spectroscopy toolkit has been developed and tested. The toolkit consists of a CsI(Tl)/PIN diode detector, integrated electronics, and a multi.channel.analyzer and its size was 40 cm(width) by 20 cm(length) by 6 cm(high). It is compact, very portable and simpler and cheaper compared to the conventional spectroscopy system. The gamma energy resolutions of the toolkit were 7.9% for the 660 keV of $^{137}Cs$ and 4.9% for 1,332 keV of $^{60}Co$ respectively. The linearity for gamma energies was good. When the energy spectrum of a ceramic sample containing $^{232}Th$ was measured with the spectroscopy toolkit for 20 minutes, there were significant peaks of the heavy metal. These results show that the resolution of the spectroscopy toolkit is sufficient to accumulate a quality spectrum in a few minutes by using weak, encapsulated commercial sources. Furthermore a toolkit experiment that how to measure energy spectra using the toolkit, and how to identify specific isotopes in a pottery piece, could be widely adopted for education and even for more sophisticated and higher level experiments.

GESS-A Code for Verification of Shielding Integrity by Monte Carlo Method (몬테칼로 방법에 의한 차폐체 건전성 검증코드 개발)

  • Lee, Tae-Young;Ha, Chung-Woo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 1986
  • GESS-a computer code for simulation of energy spectra for gamma-ray in NaI(T1) scintillator has been developed. The Monte Carlo method was employed to simulate physical behaviours of particle transport in a medium. In the processes of simulation, all the interaction processes such as Rayleigh and Compton scattering, photoelectric effect and pair production were considered. The resulting electron slowing down spectrum was also considered with the CSDA model. For the purpose of verification of the code, a measurement gamma spectrum for incident gamma energy of 1.33 MeV was performed. The measured values appeared to be slightly higher than the theoretically calculated values.

  • PDF

A Study on Dosimetric Characterization of Direct Yellow 12 Dye at High Radiation γ-Dose

  • Batool, Javaria;Shahid, Shaukat Ali;Ramiza, Ramiza;Akhtar, Nasim;Naz, Afshan;Yaseen, Maria;Ullah, Inam;Nadeem, Muhammad;Shakir, Imran
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2265-2268
    • /
    • 2012
  • Aqueous solution of oxygenated Direct yellow 12 dye has been evaluated spectrophotometrically as a possible gamma rays dosimeter. The neutral (pH-7), alkaline (pH-12.5) and acidic (pH-5.5) aqueous solution of the dye were prepared and exposed to various gamma doses. Absorption spectra of unirradiated and irradiated solutions were recorded at 400 nm peak. The increase in absorbance with the increase in irradiation dose was observed from 1 to 6 kGy. The stability response of the dye solution for different environmental conditions such as temperature (low & high), light and darkness were investigated during post irradiation storage for ten days. The dye solution showed high stability in darkness for the studied period. The optical density of the dye solution was found to be decreased at high temperature storage.

Basic characterization of uranium by high-resolution gamma spectroscopy

  • Choi, Hee-Dong;Kim, Junhyuck
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.929-936
    • /
    • 2018
  • A basic characterization of uranium samples was performed using gamma- and X-ray spectroscopy. The studied uranium samples were eight types of certified reference materials with $^{235}U$ enrichments in the range of 1-97%, and the measurements were performed over 24 h using a high-resolution and high-purity planar germanium detector. A general peak analysis of the spectrum and the $XK_{\alpha}$ region of the uranium spectra was carried out by using HyperGam and HyperGam-U, respectively. The standard reference sources were used to calibrate the spectroscopy system. To obtain the absolute detection efficiency, an effective solid angle code, EXVol, was run for each sample. Hence, the peak activities and isotopic activities were determined, and then, the total U content and $^{234}U$, $^{235}U$, and $^{238}U$ isotopic contents were determined and compared with those of the certified reference values. A new method to determine the model age based on the ratio of the activities of $^{223}Ra$ and $^{235}U$ in the sample was studied, and the model age was compared with the known true age. In summary, the present study developed a method for basic characterization of uranium samples by nondestructive gamma-ray spectrometry in 24 h and to obtain information on the sample age.

Improving light collection efficiency using partitioned light guide on pixelated scintillator-based γ-ray imager

  • Hyeon, Suyeon;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1760-1768
    • /
    • 2022
  • When gamma-camera sensor modules, which are key components of radiation imagers, are derived from the coupling between scintillators and photosensors, the light collection efficiency is an important factor in determining the effectiveness with which the instrument can identify nuclides via their derived gamma-ray spectra. If the pixel area of the scintillator is larger than the pixel area of the photosensor, light loss and cross-talk between pixels of the photosensor can result in information loss, thereby degrading the precision of the energy estimate and the accuracy of the position-of-interaction determination derived from each active pixel in a coded-aperture based gamma camera. Here we present two methods to overcome the information loss associated with the loss of photons created by scintillation pixels that are coupled to an associated silicon photomultiplier pixel. Specifically, we detail the use of either: (1) light guides, or (2) scintillation pixel areas that match the area of the SiPM pixel. Compared with scintillator/SiPM couplings that have slightly mismatched intercept areas, the experimental results show that both methods substantially improve both the energy and spatial resolution by increasing light collection efficiency, but in terms of the image sensitivity and image quality, only slight improvements are accrued.