• 제목/요약/키워드: Gamma Energy Spectrum

검색결과 170건 처리시간 0.023초

용융 아연과 WC-Co 코팅층 내 코발트의 반응거동에 미치는 아연욕 중의 Al 첨가 영향 (Effect of Al Addition on the Reaction Behavior of Pure Cobalt with Molten Zinc)

  • 성병근;김규영;권성희;이기안
    • 한국표면공학회지
    • /
    • 제40권1호
    • /
    • pp.23-31
    • /
    • 2007
  • The objective of this study is to investigate the effect of Al addition on the reaction behavior of cobalt with molten zinc. Pure cobalt specimen was immersion tested in the three kinds of molten zinc (pure, 0.12%Al added and 0.24%Al added) baths at $460^{\circ}C,\;490^{\circ}C\;and\;520^{\circ}C$. For the understanding of degradation processes, specimens were analyzed with scanning electron microscope (SEM) and energy dispersive spectrum (EDS), and electrochemical stripping method. When 0.12% and 0.24% Al was added in molten zinc baths, three intermetallic compounds layers of ${\gamma},\;{\gamma}_1,\;and\;{\gamma}_2$ were formed on the Co matrix and ${\beta}_1$ layer was not formed between the Co matrix and the ${\gamma}$ layer. Particles of CoAl intermetallic compound were formed at the interface between the ${\gamma}_2$ layer and zinc melt and they did not adhere to the Co-Zn intermetallic layer. Weight loss of the Co specimen increased as Al content in the molten zinc increased and the relationship of weight loss vs. immersion time followed parabolic rate law. Rate controlling process for the reaction rate of Co with Al added molten zinc was analyzed as the diffusion process of Al atom through a boundary layer between the ${\gamma}_2$ layer and the Al added zinc melt.

감마선(60Co) 조사에 의한 항진균 세균의 돌연변이체 유도 (Mutant Induction of Several Antifungal Bacteria by Gamma Radiation (60Co))

  • 정혜영;김재성;조규성;이영복;이영근
    • 한국환경농학회지
    • /
    • 제21권3호
    • /
    • pp.216-222
    • /
    • 2002
  • 항진균 세균의 특성 및 기능변화 가능성을 조사하기 위하여 버섯폐배지, 온천수, 해조류 및 삼림토양으로부터 식물병원성 진균에 대한 8종의 항진균 활성 균주를 분리하였고 감마선($^{60}Co$)을 이용하여 $LD_{95}$에서 돌연변이체를 유도하였다. Bacillus circulans K1, Burkholderia gladioli K4와 Bacillus subtilis YS1은 12 종의 식물병원성 진균에 대해 항진균 활성을 보였다. 이들 균주의 방사선감수성 조사결과 B. gladioli K4는 감마선에 대한 높은 감수성을 보였으며, $D_{10}$ 값은 0.11 kGy 였다. 감마선에 의해 유도된 K1-1004와 YS1-1009는 Botryosphaeria dothidea에 대해 항진균 활성이 증가되었다. B. subtilis YS1의 돌연변이체인 YS1-1006과 YS1-1009는 tebuconazol과 copper hydroxide에 대해 농약 저항성을 나타냈다. SAR535, SAR5108 과 SAR5l18 돌연변이체는 야생형 균주인 Streptomyces sp. SAR01에 비해 5 종의 식물병원성 진균에 대해 항진균 활성이 없었다. 연구결과, 방사선을 이용하여 다양한 기능의 돌연변이체 유도가 가능하였다. 이를 이용하여 항진균 활성 관련 유전자 연구 및 균주개량이 가능할 것으로 사료된다.

Detection of DNA Instability Induced from Tissue Culture and Irradiation in Oryza sativa L. by RAPD Analysis

  • Kim, Dong-Sub;Lee, In-Sok;Hyun, Do-Yoon;Jang, Cheol-Seong;Song, Hi-Sup;Seo, Yong-Weon;Lee, Young-Il
    • Journal of Plant Biotechnology
    • /
    • 제5권1호
    • /
    • pp.25-31
    • /
    • 2003
  • As a consequence of tissue culture of rice, RAPD analysis was peformed to determine whether extended culture periods as undifferentiated calli affected the subsequent genetic constancy, and whether any resulting DNA rearrangements could be detected between sibling plants produced from the same callus. Somaclonal variation was induced at the initial stage of tissue culture and it increased with the length of culture maintenance. Of the 192 total bands, the number of polymorphic bands was 22 (11.5%), 33 (17.2%), and 49 (25.5%) in the callus of 1,3, and 6 months culture, respectively. A significantly higher level of genotypic polymorphisms between regenerants from two different somaclones was also detected, although all the regenerants were derived from a single genotype. In comparison of DNA polymorphisms between regenerants from non-irradiated and from irradiated calli, a scope of variation spectrum by gamma ray irradiation was larger than that by tissue culture. Consideration must be given to this genomic variation where attempts are to be made to use desirable somaclonal variants for plant breeding purpose and in genetic engineering program.

중성자방사화분석에 의한 Algae중의 독성미량원소의 정량 및 실험실간 비교검증 (Data intercomparison and determination of toxic and trace elements in Algae using Instrumental Neutron Activation Analysis)

  • 정용삼;문종화;박광원;이길용;윤윤열
    • 분석과학
    • /
    • 제12권4호
    • /
    • pp.346-353
    • /
    • 1999
  • For the non-destructive multi-elemental analysis of environmental and biological materials, instrumental neutron activation analysis (INAA) was applied for the determination of toxic and trace elements in a set of three Algae samples provided by the International Atomic Energy Agency (IAEA). The analytical quality control was evaluated by comparing the analytical results of two standard reference materials of the National Institute of Standards and Technology (NIST); Oyster Tissue (SRM 1566a) and Citrus Leaves (SRM 1572). According to given analytical procedure, the concentration of 15-25 elements including spiked elements such as As, Cd, Cr and Hg in Algae samples were determined. To identify and validate these results, a data intercomparison program using more than 35 analytical methods in 150 laboratories was carried out and the estimated statistical data are summarized. Result of INAA is favorable, therefore, it is illustrated that can be applied for routine analysis of essential and toxic elements in algae samples as well as analytical quality assurance.

  • PDF

Comparison of Environmental Radiation Survey Analysis Results in a High Dose Rate Environment Using CZT, NaI(Tl), and LaBr3(Ce) Detectors

  • Sungyeop Joung;Wanook Ji;Eunjung Lee;Young-Yong Ji;Yoomi Choi
    • 방사성폐기물학회지
    • /
    • 제21권4호
    • /
    • pp.543-558
    • /
    • 2023
  • Currently, Japan is undertaking a nationwide project to measure and map radioactive contamination around Fukushima, as part of the efforts to restore normalcy following the nuclear accident. The Japan Atomic Energy Agency (JAEA) manages the Fukushima Environmental Safety Center, located approximately 20 km north of the Fukushima Daiichi nuclear power plant in Minamisōma City, Fukushima Prefecture. In collaboration with the JAEA, this study involved conducting comparison experiments and analyses with radiation detectors in high radiation environments, a challenging task in Korean environments. Environmental radiation surveys were conducted using three types of detectors: CZT, NaI(Tl), and LaBr3(Ce), across two contaminated areas. Dose rate values were converted using dose rate conversion factors for each detector type, and dose rate maps were subsequently created and compared. The detectors yielded similar results, demonstrating their feasibility and reliability in high radiation environments. The findings of this study are expected to be a crucial reference for enhancing the verification and supplementation of procedures and methods in future radiation measurements and mobile surveys in high-radiation environments, using these three types of radiation instruments.

7-Diethylamino-4-methylcoumarin 기반 섬광체 제작 및 방사능 검출특성평가 (Fabrication of 7-Diethylamino-4-methylcoumarin-based Scintillator for Gamma Radiation Detection)

  • 민수정;노창현;서범경;홍상범
    • 방사선산업학회지
    • /
    • 제17권1호
    • /
    • pp.69-73
    • /
    • 2023
  • Commercially used organic scintillation materials (1,4 di[2-(5phenyloxazolyl)] benzene) have low solubility in solvents and a wide emission energy range, which causes a decrease in detection efficiency. In this study, an organic liquid scintillator with improved detection efficiency was developed using 7-Diethylamino-4-methylcoumarin material to compensate for the disadvantages of existing organic scintillation detectors. And to evaluate the applicability of radiation measurement, the performance of a commercial plastic detector was compared. As a result of analyzing the 60Co detection characteristics by applying 7-Diethylamino-4-methylcoumarin as an alternative to 1,4 di[2-(5phenyloxazolyl)] benzene, the detection efficiency was improved around 2% compared with commercial scintillator when the 7-Diethylamino-4-methylcoumarin content was 0.04 wt%. Based on the results of this study, the possibility of improving detection efficiency through scintillator material modification was confirmed. In addition, since it is possible to discriminate nuclide through the spectrum correction algorithm, it will be possible to inspect and classify various decommissioning wastes generated during the decommissioning process.

Binding energy study from photocurrent signal inphotoconductive a $ZnIn_2S_4$ thin films

  • Hong, Kwang-Joon
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.380-380
    • /
    • 2010
  • The chalcopyrite $ZnIn_2S_4$ epilayers were grown on the GaAs substrate by using a hot-wall epitaxy (HWE) method. The crystal field and the spin-orbit splitting energies for the valence band of the $ZnIn_2S_4$ have been estimated to be 0.1541 eV and 0.0129 eV, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}so$ definitely exists in the $\Gamma_5$ states of the valence band of the $ZnIn_2S_4$/GaAs epilayer. The three photocurrent peaks observed at 10 K are ascribed to the $A_{1^-}$, $B_{1^-}$, and $C_1$-exciton peaks for n = 1. Also, we obtained the $A_{\infty^-}$ and B-exciton peaks from the PC spectrum at 293 K.

  • PDF

조직 등가 섬광체를 이용한 계수형 선량계의 개발과 특성 평가 (Development and Characterization of a Dosimeter Using Tissue-Equivalent Scintillator by Photon-Counting Method)

  • 천종규;김성환;김홍주
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.29-34
    • /
    • 2014
  • A dosimeter using tissue-equivalent scintillator by photon-counting method was developed and evaluated in its performance. The dosimeter is portable and can be operated by low power from lap-top computer. A data-acquisition software of the dosimeter system was developed by Labwindows/CVI based on Windows. The energy to channel ratio for energy calibration was 0.839 keV/ch. obtained from pulse height spectrum of $^{137}Cs$ and $^{60}Co$ gamma-ray. Using the dosimeter system, the absorbed dose of environmental radiation in Gyungju was 0.18 ${\mu}Sv/h$.

A SPECTROSCOPIC STUDY OF THE SEYFERT GALAXY MCG-2-58-22

  • Choi, Chul-Sung;Dotani, Tadayasu;Chang, Heon-Young
    • 천문학회지
    • /
    • 제38권3호
    • /
    • pp.339-344
    • /
    • 2005
  • We present analysis results of the energy spectra of MCG-2-58-22 associated with occasional flares which appear in a long-term X-ray light curve. We measure an intrinsic power-law slope of this object to be ${\Gamma}=1.74{\pm}0.02$ in the energy range of ${\sim}1-5keV$ and find that this slope is little affected by flares. We confirm that there exists a broad excess emission above 5 keV to the power-law continuum. The excess emission is less variable compared with a flux variation of flare and tends to be relatively weak during flares. A soft X-ray spectrum is also found to change, implying the presence of a variable soft component. We discuss the implications of these spectral variations.

Neutron diagnostics using nickel foil activation analysis in the KSTAR

  • Chae, San;Lee, Jae-Yong;Kim, Yong-Soo
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3012-3017
    • /
    • 2021
  • The spatial distribution and the energy spectrum of the neutron yield were investigated with the neutron activation analysis and MCNP simulation was carried out to verify the analysis results and to extend the results to a 3D mapping of the neutron yield distribution in the KSTAR. High purity Ni specimen was selected in the neutron activation analysis. Total neutron yields turned out to be 3.76 × 1012 n/s - 7.56 × 1012 n/s at the outer vessel of the KSTAR, two orders of magnitude lower than those at the inner vessel of the KSTAR, which demonstrates the attenuation of neutron yield while passing through the different structural materials of the reactor. Based on the fully expanded 3D simulation results, 2D cross-sectional distributions of the neutron yield on XY and ZX planes of KSTAR were examined. The results reveal that the neutron yield has its maximum concentration near the center of blanket and decreases with increasing proximity to the vacuum vessel wall.