• Title/Summary/Keyword: Gamma (${\gamma}$)-ray

Search Result 1,793, Processing Time 0.025 seconds

What we have learned about Gamma-ray bright AGNs using the iMOGABA program

  • Lee, Sang-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.45.1-45.1
    • /
    • 2017
  • A Korean VLBI Network Key Science Program, the Interferometric Monitoring of Gamma-ray Bright AGNs (iMOGABA) program continues to aim at revealing the origins of the gamma-ray flares that are often detected in active galactic nuclei (AGNs). Here in this presentation, we would like to present what we have learned about the Gamma-ray bright AGNs based on the recent results of the Korean VLBI Network Key Science Program: the iMGOABA. The results will include a) the source properties of the whole samples obtained from a single-epoch observation, and b) some of scientific highlights for the iMOGAGBA on specific sources. From those highlighted works, we find that the Gamma-ray bright AGNs become fainter at higher frequencies, yielding optically thin spectra at mm wavelengths. Based on the studies on specific sources, taking into account the synchrotron self-absorption model of the relativistic jet, we estimated the magnetic field strength in the mas emission region during the observing period.

  • PDF

Region-wise evaluation of gamma-ray exposure dose in decontamination operation after a nuclear accident

  • Jeong, Hae Sun;Hwang, Won Tae;Han, Moon Hee;Kim, Eun Han;Lee, Jo Eun;Lee, Cheol Woo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2652-2660
    • /
    • 2021
  • The gamma-ray exposure doses in decontamination operation after a nuclear accident were evaluated with a consideration of various geometrical conditions and specific gamma-ray energies. The calculation domain is organized with three residence types and each form is divided into two kinds of geometrical arrangements. The position-wise air KERMA values were calculated with an assumption of evenly distributed gamma-ray source based on Monte Carlo radiation transport analysis using the MCNP code. The radioactivity is initially set to be unity to be multiplied by the deposition value measured in the actual accident condition. The workforce data set depending on the target object was determined by modifying the Fukushima report. The external exposure doses for decontamination workers were derived from the calculated KERMA values and the workforce analysis. These results can be used to efficiently determine the workforce required by the characteristics of the area and the structure to be decontaminated within the dose limits.

The Development of Beam Profiling System for the Analysis of Pulsed Gamma-ray Using the Electron Accelerator (전자빔가속기를 이용한 펄스감마선 출력특성 분석용 빔프로파일링 장치개발)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2410-2416
    • /
    • 2016
  • Recently, most countries in the world have pursued a denuclearization. So it has been of interest to increase to Nuclear weapon in such as North Korea's continued nuclear test. Pulsed gamma rays produced in the nuclear explosion and the space environment can give the big damage to the electronic device in a very short period of time. To confirm the extent of damage of these electronic devices, pulsed gamma irradiation facility that can occur in nuclear weapon or space environment are required. In this paper, we implemented the pulsed gamma-ray detection module and analyzed output of the irradiation test. We have experimented using an electron beam accelerator research facilities in Pohang Accelerator similar conditions to equip and Nuclear weapon. As a result, we confirmed that the pulsed gamma rays emitted by the gamma radiation and electron beam conversion device. The results of this paper will contribute to improve the reliability and accuracy of studies for utilizing pulsed gamma rays.

Influence of low dose ${\gamma}$ radiation on the physiology of germinative seed of vegetable crops (저선량 감마선이 채소 발아종자의 생리활성에 미치는 영향)

  • Kim, Jae-Sung;Lee, Eun-Kyung;Back, Myung-Hwa;Kim, Dong-Hee;Lee, Young-Bok
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.1
    • /
    • pp.58-61
    • /
    • 2000
  • This study was conducted to determine the effect of low dose ${\gamma}-ray$ on the germination rate and physiology of germinative seeds of welsh onion ( Allicm fistulosum L. cv. Sukchangwoidae ) and spinach ( Spinacia oleracea L. cv. Chungrok ). The germination rate of irradiation group was much higher than that of the control. Especially it was noticeably higher in 1 or 2 Gy irradiation groups in the sowing spinach seeds on paper towel. On the welsh onion, the germination rate of the 1 Gy irradiation group increased by 17% compared to that of the control. Ion leakage from seeds irradiated with low dose of ${\gamma}-ray$ was decreased compared to that from the control especially at the early stage of incubation when examined by means of electric conductance. This tendency was confirmed in seeds of welsh onion and spinach. Starch hydrolysis was stimulated by ${\gamma}-ray$ irradiation in welsh onion. Furthermore ${\gamma}-ray$ irradiation was beneficial to keeping the vitality of seeds as determined through decarboxylation of glutamic acid.

  • PDF

A STUDY ON THE MICROSTRUCTURES OF THE AMALGAM ALLOYS AND AMALGAMS (치과용 아말감합금 및 아말감의 마세구조에 관한 연구)

  • Yeon, Sang-Heum;Lee, Chung-Sik;Lee, Myung-Jong;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.87-105
    • /
    • 1996
  • The purpose of this study is to investigate the characteristics of the compositions and phases of amalgam alloys and amalgams by using EMPA and X-ray diffractometer. Each specimen was made from Caulk Fine Cut Clow copper lathe cut amalgam), Caulk Spherical (low copper spherical amalgam), Tytin (high copper unicorn position amalgam), Dispersally (high copper admixed amalgam) and Valiant (Palladium enriched amalgam). For preparing amalgam alloys, Tytin and Valiant were used as powder forms and the others were used as tablet forms after being polished with polishing machine. For preparing amalgams, each amalgam alloy and Hg were measured, and triturated by mechanical amalgamater according to user's instructions. After triturating, the triturated mass was inserted to cylindrical metal mold and simultaneously adapted by cylindrical condenser with same diameter and condensed by Instron universal testing machine with 80kg pressure & 1mm/min speed. Each specimen was removed from the metal mold and stored at room temperature for a week. The specimen was polished with the same polishing machine for amalgam alloy. For observation of microstructure and analysis of composition of amalgam alloys and amalgams, EMPA was used to get secondary electron images, backscattered images and characteristic X-ray images of Ag, Sn, Cu, Zn, Hg. To analyze compositions of amalgam alloys and amalgams, X-ray diffractometer was used. Amalgam alloys were scanned at the range of 2${\theta}$ of 30-$85^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line and amalgams were scanned at the range of 2${\theta}$ of 28-$44^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line. By comparing obtained d(distance between surfaces) and d of expected phases and atoms in amalgam alloys and amalgams in ASTM card, phases and atoms were identified. The results were as follows, 1. In Caulk Fine Cut amalgam alloy typical ${\gamma}$ phase was shown, and in amalgam, ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phases were observed. 2. In Caulk Spherical amalgam alloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, ${\gamma}_2$ and $\eta$ phases were observed. 3. In Tytin amalgam alloy ${\gamma}$, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 4. In Dispersalloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 5. In Valiant alloy ${\gamma}$, Cu and e phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed.

  • PDF

Plasmid DNA damage by neutron and ${\gamma}$-ray in the presence of BSH (BSH 존재시 중성자 및 ${\gamma}$-ray 조사에 따른 plasmid DNA의 손상)

  • Chun, Ki-Jung;Seo, Won-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.2
    • /
    • pp.65-68
    • /
    • 2006
  • In this study, the extent of plasmid DNA damage was observed according to concentration of BSH(Boron Sulfhydryl Hydride) and irradiation doses of neutron and ${\gamma}$-ray. The plasmid used was both pBR 322 (2870 bp) and ${\Phi}X174$ RF(5386 bp) DNA. Plasmid DNA damage by irradiation in the presence of BSH was analyzed by agarose gel electrophoresis. In the neutron experiment, DNA damage of both plasmid DNAs was increased according to increasing the concentration of BSH and neutron doses. But in the ${\gamma}$-ray experiment, there appeared no dose dependency as compared to the neutron experiment. The extent of the plasmid DNA damage in the presence of BSH was somewhat different according to irradiation by neutron or ${\gamma}$-ray.

Gamma-ray Emission from Globular Clusters

  • Tam, Pak-Hin T.;Hui, Chung Y.;Kong, Albert K. H.
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • Over the last few years, the data obtained using the Large Area Telescope (LAT) aboard the Fermi Gamma-ray Space Telescope has provided new insights on high-energy processes in globular clusters, particularly those involving compact objects such as MilliSecond Pulsars (MSPs). Gamma-ray emission in the 100 MeV to 10 GeV range has been detected from more than a dozen globular clusters in our galaxy, including 47 Tucanae and Terzan 5. Based on a sample of known gammaray globular clusters, the empirical relations between gamma-ray luminosity and properties of globular clusters such as their stellar encounter rate, metallicity, and possible optical and infrared photon energy densities, have been derived. The measured gamma-ray spectra are generally described by a power law with a cut-off at a few gigaelectronvolts. Together with the detection of pulsed γ-rays from two MSPs in two different globular clusters, such spectral signature lends support to the hypothesis that γ-rays from globular clusters represent collective curvature emission from magnetospheres of MSPs in the clusters. Alternative models, involving Inverse-Compton (IC) emission of relativistic electrons that are accelerated close to MSPs or pulsar wind nebula shocks, have also been suggested. Observations at >100 GeV by using Fermi/LAT and atmospheric Cherenkov telescopes such as H.E.S.S.-II, MAGIC-II, VERITAS, and CTA will help to settle some questions unanswered by current data.

A study on the aquatic eco-risk assessment of antibiotics treated by radiation (방사선으로 처리된 항생물질의 수서 생태위해성 평가)

  • Kang, Seon-Hong;Chang, Jae-Goo;Ka, Soon-Kyu;Kim, Hyun-Young;Kim, Sang-Don;Lee, Myun-Joo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.373-381
    • /
    • 2012
  • Antibiotics have been issued recently in water environments because of potential impacts on ecosystem and public health. This study was aimed to investigating the degradation of antibiotics such as tetracycline, lincomycin, sulfamethazine and cephradine using gamma ray irradiation. And the toxicity before and after irradiation on antibiotics was tested in order to examine the aquatic eco-risk assessment by aquatic organisms. In addition, comparing tests on toxicity for gamma ray and UV irradiated antibiotics was conducted. Four different antibiotics were prepared by concentration of 30 mg/L with demi-water respectively. The absorption dose of gamma ray was ranged from 0.2 to 2 kGy. The concentration of four antibiotics was gradually decreased corresponding to the increase of the absorption dose. A method for toxicity assessment using Pseudokirchneriella subcapitata was evaluated to the most acceptable compared with methods by Daphnia magna and Microtox$^{(R)}$ in terms of sensibility. It showed that the reduction of toxicity on antibiotics treated by gamma ray was superior comparing to the test results obtained from UV treatment. By-products from antibiotics treated by gamma ray were easily decomposed by microorganism and their toxicity was also evaluated to low.

On the change of glucose and phosphorus of the silkworm eggs Bombyx, mori. L. during it development and the effect of ${\gamma}$-ray irradiation. (가잠란배자발육과정에서 Glucose와 phosphorus의 변동 및 방사선에 의한 영향)

  • 김원경;임영우
    • Journal of Sericultural and Entomological Science
    • /
    • v.10
    • /
    • pp.63-66
    • /
    • 1969
  • As a result of analyzing the change of material substance of all sorts biochemically and comparing the control with ${\gamma}$-ray irradiation (800r, 400 min), incubating the silkworm egges (bombyx. mori. L.) as the objective in the process of growth of embryo shortly before hatching, the following conclusion has been found. 1. Glucose has shown the increase of 281.2 mg/g in control during the pigment stage and it has shown the increase of 179.6 mg/g in ${\gamma}$-ray irradiation during the same period. The difference in quantity between the former and the latter is due to the fact that the growth of embryo has been influenced by the radio active. Glucose has changed with phosphorus the other way round. 2. Control organic phosphorus has shown the increase of 5.23 mg/g during the Byong B or KI A in which organ and tissue in the embryo has been formed. Organic phosphorus in ${\gamma}$-ray irradiation has shown the increase of 5.73 mg/g during KI B. Inorganic Phosphorus has shown only a little change in the control and ${\gamma}$-ray irradiation. The phosphorus in both has shown a little quantity in the ${\gamma}$-ray irradiation in early period of incubation. After the Ki A embryo, it has increased rapidly and it has increased till the hatching more continually than in control. The about results of the research will be helpful and instructive to the betterment and improvement, breeding and management of animals and plants.

  • PDF

Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline (단열배관의 온라인 두께측정시스템 개발)

  • Jang, Ji-Hun;Kim, Byeong-Ju;Jo, Gyeong-Sik;Kim, Gi-Dong
    • 연구논문집
    • /
    • s.32
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF