• Title/Summary/Keyword: Gallium arsenide

Search Result 58, Processing Time 0.026 seconds

Effects of Low Power Laser Irradiation on the Spinal Cord for the Functional Regeneration of Crushed Sciatic Nerve in Rats (흰쥐 좌골신경 압좌손상 후 척수분절의 저강도 레이저 조사가 운동기능 회복에 미치는 영향)

  • Kim, Souk-Boum;Kim, Dong-Hyun;Song, Ju-Min;Nam, Ki-Won;Kwon, Young-Shil;Kim, Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.569-578
    • /
    • 2001
  • The purpose of the present study was to examine the functional recovery of the crushed sciatic nerve of rats after low-power laser irradiation applied to the corresponding segments of the spinal cord. After a crushed injury on the left sciatic nerve in rats. low-power laser irradiation was applied transcutaneously to corresponding segments of the spinal cord immediately after suture the wound by using 2000 mW, 2000Hz, 830 nm CaAIAs(Gallium-aluminum-arsenide) semiconductor diode laser. The laser treatment was performed with 10 minutes daily for 4 successive weeks. Functional recovery was evaluated per weekly following injury by sciatic function index(SFI),using data obtained by walking track analysis. For four weeks after crush injury, experimental group had significantly greater functional improvement than control group(${\alpha}$=0.05). In a experimental group, SFI was significantly increased for three weeks, but control group not increased for two weeks. This study suggests that low-power laser irradiation applied directly to the spinal cord can improve functional recovery of the crushed sciatic nerve in rats.

  • PDF

Clinical Effect Of Low Level Laser Therapy In The Treatment Of Dentin Hypersensitivity Following Periodontal Surgery (치주수술 후 상아질 지각과민증에 대한 저수준 레이저 처치의 임상적 효과)

  • Kim, Nam-Yun;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.230-243
    • /
    • 1996
  • Root surface exposure due to gingival recession after periodontal surgery, dentin exposure after root planing elicit pain response when exposed to mechanical, heat, chemical or osmotic stimulation. Especially, patients treated with periodontal surgery, show high frequency and there have been reports showing the 1 out of 7 patients have dentin hypersensitivity. There have been many studies on the clinical effects of various materials on the treatment of dentin hypersensitivity. but, none could provide absolute clinical efficacy. In this study, 45 teeth from 30 patients, who had had periodontal surgery and showed dentin hypersensitivity after surgery were chosen for the experimental group and they were illuminated with laser, 15teeth were chosen for the control group and they were not exposed to laser. After this dentin hypersensitivity was elicited by tactile, compressed air, cold water and then, the degree was evaluated using NRS(Numerical Rating Scale). And during LLLT(Low Level Laser Therapy) semiconductor laser using Gallium - Arsenide as a diode was illuminated for 180 seconds at a frequency of 7(500Hz). This therapy was done 10 times, and each time the changes in dentin hypersensitivity was evaluated using NRS. The results were as follows : 1. After treat with LLLT on dentin hypersensitivity due to periodontal surgery, 22.2% showed total loss of dentin hypersensitivity, 60.0% showed loss of tactile dentin hypersensitivity, 48.8% showed loss of compressed air dentin hypersensitivity, 22.2% showed loss of cold water dentin hypersensitivity. 2. As a result of clinical evaluation of dentin hypersensitivity using NRS, there was significant increase in improvement of dentin hypersensitivity in the experimental group compare to the control group(P<0.05). And there was almost no natural loss of dentin hypersensitivity in the control group. 3. In comparison of the stages of evaluation, there was significant difference in between experimental and control group. after the second visit(P<0.05), and the difference increased with each visit.

  • PDF

Effects of GaAIAs Diode Laser for the Expression of TGF-$\beta$ on Lumbar Spinal Cord after Extensor Digitorum Muscle Crush Injury (GaAlAs 다이오드 레이저 조사가 장지신근 압좌손상 후 요수분절의 TGF-$\beta$ 발현에 미치는 영향)

  • Kim Souk-Boum;Nam Ki-Won;Koo Hyun-mo;Lee Sun-Min;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.87-94
    • /
    • 2002
  • Low intensity laser irradiation is potential physical agent that triggers the muscle regeneration by previous study. In muscle regeneration, a number of growth factors also promotes that is triggered in response to muscle damage. The transforming growth factor(TGF)-$\beta$ is involved in the activation of cell proliferation and the inhibition of cell differentiation in muscle regeneration. This is secreted not only autocrine system but also paracrine and endocrine. Therefore, We investigated that effects of Gallium aluminum arsenide(GaAlAs) diode laser for the expression of TGF-$\beta$ on lumbar spinal cord after extensor digitorum muscle crush injury. After laser irradiation, the immunoreactivity of TGF-$\beta$ was increased bilaterally in gray mater of spinal cord. Especially, in 1 day, experimental group was highed than control, and in 3 day, lateral motor nucleus were storong immunoreactivy of TGF-$\beta$. Also, in 1 and 2 day, TGF-$\beta$ was showed in white mater as well as gray mater, but in 3 day, only showed in gray mater. These data may suggests to the establishment of laser irradiation on spinal cord for skeletal muscle injury.

  • PDF

The Effects of Low Power Laser for the Expression of Epithelial Growth Factor in the Burned Skin of the Rats (흰쥐의 피부화상 후 저강도 레이저 조사가 표피성장인자의 발현에 미치는 영향)

  • Lee Sun-Min;Koo Hyun-Mo;Nam Ki-Won;Kim Souk-Boum;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.226-237
    • /
    • 2002
  • This study was performed to investigate the effect of low power laser irradiation on epidermal growth factor(EGF) expression in the burned skin of the rats. Burns of about 3cm in diameter were created with 75'c water on the back of the rats, and the lesion of experimental group were irradiated on days 1, 2, and 3 postwounding. Control tensions were not irradiated. After burns, low power laser irradiation was applied by using 1000Hz, 830nm GaAlAs (Gallium-aluminum- arsenide) semiconductor diode laser. The expression of epidermal growth factor evaluated immunohistochemistry on mouse anti-EGF. The results of this study were as follows 1. In expression of EGF, the lesion of experimental group made EGF to more induce significantly than control tensions. 2. EGF immunoreactivity in burned skin were increased markedly 3 days after burns, and increased gradually from 1 day to 2 days in burns which is laser irradiation These data suggest that low power laser have wound healing effect in the burned skin of the rats.

  • PDF

Prediction of Chemical Composition in Distillers Dried Grain with Solubles and Corn Using Real-Time Near-Infrared Reflectance Spectroscopy

  • Choi, Sung Won;Park, Chang Hee;Lee, Chang Sug;Kim, Dong Hee;Park, Sung Kwon;Kim, Beob Gyun;Moon, Sang Ho
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.33 no.3
    • /
    • pp.177-184
    • /
    • 2013
  • This work was conducted to assess the use of Near-infrared reflectance spectroscopy (NIRS) as a technique to analyze nutritional constituents of Distillers dried grain with solubles (DDGS) and corn quickly and accurately, and to apply an NIRS-based indium gallium arsenide array detector, rather than a NIRS-based scanning system, to collect spectra and induce and analyze calibration equations using equipment which is better suited to field application. As a technique to induce calibration equations, Partial Least Squares (PLS) was used, and for better accuracy, various mathematical transformations were applied. A multivariate outlier detection method was applied to induce calibration equations, and, as a result, the way of structuring a calibration set significantly affected prediction accuracy. The prediction of nutritional constituents of distillers dried grains with solubles resulted in the following: moisture ($R^2$=0.80), crude protein ($R^2$=0.71), crude fat ($R^2$=0.80), crude fiber ($R^2$=0.32), and crude ash ($R^2$=0.72). All constituents except crude fiber showed good results. The prediction of nutritional constituents of corn resulted in the following: moisture ($R^2$=0.79), crude protein ($R^2$=0.61), crude fat ($R^2$=0.79), crude fiber ($R^2$=0.63), and crude ash ($R^2$=0.75). Therefore, all constituents except for crude fat and crude fiber were predicted for their chemical composition of DDGS and corn through Near-infrared reflectance spectroscopy.

Characteristics of Power Amplifier for Energy Efficient Broadcasting Services (에너지 효율적 차세대 방송망 구축을 위한 증폭기 특성과 신호 모델)

  • Han, Jae-Shin;Jeon, Sungho;Choi, Jeong-Min;Seo, Jong-Soo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.6
    • /
    • pp.884-894
    • /
    • 2013
  • In this paper, we investigate the characteristics of power amplifiers and simplified memoryless non-linear power amplifier models for energy efficient communication system. First, we present the transfer function of GaAs FET (Gallium Arsenide Field Effect Transistor) that is widely used for high power amplifier. From those investigations, we introduce the instantaneous efficiencies and methods of amplification by assuming that the saturated current is constant, while perfect linearity is exploited under knee voltage. Then, we discuss four non-linear power amplifier models in a baseband signal processing. Finally, we explain the specified total power consumption model in a base station to achieve the resonable analysis for energy efficient communication.

The Effect of Representative Dataset Selection on Prediction of Chemical Composition for Corn kernel by Near-Infrared Reflectance Spectroscopy (예측알고리즘 적용을 위한 데이터세트 구성이 근적외선 분광광도계를 이용한 옥수수 품질평가에 미치는 영향)

  • Choi, Sung-Won;Lee, Chang-Sug;Park, Chang-Hee;Kim, Dong-Hee;Park, Sung-Kwon;Kim, Beob-Gyun;Moon, Sang-Ho
    • Journal of Animal Environmental Science
    • /
    • v.20 no.3
    • /
    • pp.117-124
    • /
    • 2014
  • The objectives were to assess the use of near-infrared reflectance spectroscopy (NIRS) as a tool for estimating nutrient compositions of corn kernel, and to apply an NIRS-based indium gallium arsenide array detector to the system for collecting spectra and analyzing calibration equations using equipments designed for field application. Partial Least Squares Regression (PLSR) was employed to develop calibration equations based on representative data sets. The kennard-stone algorithm was applied to induce a calibration set and a validation set. As a result, the method for structuring a calibration set significantly affected prediction accuracy. The prediction of chemical composition of corn kernel resulted in the following (kennard-stone algorithm: relative) moisture ($R^2=0.82$, RMSEP=0.183), crude protein ($R^2=0.80$, RMSEP=0.142), crude fat ($R^2=0.84$, RMSEP=0.098), crude fiber ($R^2=0.74$, RMSEP=0.098), and crude ash ($R^2=0.81$, RMSEP=0.048). Result of this experiment showed the potential of NIRS to predict the chemical composition of corn kernel.

Low-level laser therapy affects osseointegration in titanium implants: resonance frequency, removal torque, and histomorphometric analysis in rabbits

  • Kim, Jong-Ryoul;Kim, Sung-Hee;Kim, In-Ryoung;Park, Bong-Soo;Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.1
    • /
    • pp.2-8
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the effects of low-level laser therapy (LLLT) with a diode gallium-aluminum-arsenide (Ga-Al-As) low-level laser device on the healing and attachment of titanium implants in bone. Materials and Methods: Thirteen New Zealand white male rabbits weighing $3.0{\pm}0.5kg$ were used for this study. Dental titanium implants (3.75 mm in diameter and 8.5 mm in length, US II RBM plus fixture; Osstem, Seoul, Korea) were implanted into both femurs of each rabbit. The rabbits were randomly divided into a LLLT group and a control group. The LLLT was initiated immediately after surgery and then repeated daily for 7 consecutive days in the LLLT group. Six weeks and 12 weeks after implantation, we evaluated and compared the osseointegration of the LLLT group and control group, using histomorphometric analysis, removal torque testing, and resonance frequency analysis (RFA). The results were statistically significant when the level of probability was 0.05 or less based on a non-parametric Mann-Whitney U-test. Results: The implant survival rate was about 96%. Histologically and histomorphometrically, we observed that the titanium implants were more strongly attached in LLLT group than in control group. However, there was no significant difference between the LLLT group and control group in removal torque or RFA. Conclusion: Histologically, LLLT might promote cell-level osseointegration of titanium implants, but there was no statistically significant effects.

Multi-Junction Space Solar Cell Health Checking Method using Electroluminescence Phenomena (전계발광현상을 이용한 우주용 다접합 태양전지의 건전성 평가기법)

  • Park, Je-Hong;Chang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1017-1026
    • /
    • 2009
  • The solar cell system operates by facing the sun-light. Minor cracks, static discharge, and thermal shock that can happen during production/testing phase can lead to degradation in performance during operation, since solar cells are exposed to extreme thermal/mechanical environment in space. In order to detect small cracks and internal damages in the solar cells due to thermal shocks, which are the core units of a solar cell system, expensive equipment, complicated test process, and much time are required. Therefore, a qualitative method for easily and quickly testing the 'health' of solar cell functionality is required. This dissertation describes a theoretical and technical grounds for quickly and easily evaluating the health of solar cells using electroluminescence effect of Gallium-Arsenide solar cells that are most widely used by spacecrafts in recent years. Also described in the dissertation is the technical issues and constraining factors for applying the proposed method to actual space-rated solar cell systems.

Effects of Low Power Laser for the Expression of EGF after Muscle Crush Injury (저강도레이저 조사가 근육압좌손상 후 척수분절의 EGF 발현에 미치는 영향)

  • Kim Souk-Boum;Kim Dong-Hyun;Nam Ki-Won;Lee Sun-Min;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.16-25
    • /
    • 2002
  • Low energy laser irradiation(LELI) therapy in physical therapy is widespread but the mechanisms are not fully understood. The purpose of the present study was to examine the epidermal growth factor(EGF)'s expression within lumbar spinal cord which corresponding with crushed extensor digitorum longus(EDL) of rats after low-power laser irradiation applied. After a crushed injury on the right EDL, low-power laser irradiation was applied by using 2000mW, 2000Hz, 830nm GaAlAs(Gallium-aluminum-arsenide) semiconductor diode laser. The laser treatment was performed with 10 minutes daily for 3days. After EDL crush injury, EGF immunoreactive positive neurons in experimental group were progressively decreased from the first to third days. Especially 1 day subgroup is highly expressed in dorsal horn(Lamina I, II, III) and around of central cannal of spinal cord(Lamina VII). Control group was only expressed slightly at 3 days. This study suggests that LELI stimulate that release and migration of EGF in spinal cord, which distict to wound site, therfore promote wound healing of EDL crush injury.

  • PDF