• Title/Summary/Keyword: Gait Pattern Change

Search Result 46, Processing Time 0.033 seconds

Gait Study on the Normal and ACL Deficient Patients After Ligament Reconstruction Surgery Using Chaos Analysis Method (전방십자인대 재건수술 환자와 정상인의 보행 연구)

  • Ko Jae-Hun;Moon Byung-Young;Suh Jeung-Tak;Son Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.435-441
    • /
    • 2006
  • The anterior cruciate ligament(ACL) is an important stabilizer of knee joint. The ACL injury of knee is common and a serious ACL injury leads to ligament reconstruction surgery. Gait analysis is essential to identify knee condition of patients who display abnormal gait. The purpose of this study is to evaluate and classify knee condition of ACL deficient patients using a nonlinear dynamic method. The nonlinear method focuses on understanding how variations in the gait pattern change over time. The experiments were carried out for 17 subjects(l2 healthy subjects and five subjects with unilateral deficiency) walking on a motorized treadmill for 100 seconds. Three dimensional kinematics of the lower extremity were collected by using four cameras and KWON 3D motion analysis system. The largest Lyapunov exponent calculated from knee joint flexion-extension time series was used to quantify knee stability. The results revealed the difference between healthy subjects and patients. The deficient knee was significantly unstable compared with the contralateral knee. This study suggests an evaluation scheme of the severity of injury and the level of recovery. The proposed Lyapunov exponent can be used in rehabilitation and diagnosis of recoverable patients.

A Case Report of Korean Medical Treatment on Atypical Parkinsonism Patient Complaining of Gait Disturbance Using 3-Demensional Gait Analysis System (3차원 보행분석기를 통해 보행장애의 호전이 확인된 비정형 파킨슨증후군 환자 한방치험 1례)

  • Hye-Min Heo;Kyeong-Hwa Lee;Kyeong-Hwa Heo;Ye-Chae Hwang;Seung-Yeon Cho;Jung-Mi Park;Chang-Nam Ko;Seong-Uk Park
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.13-24
    • /
    • 2023
  • ■Objectives This case study is to report the effects of Korean medicine on parkinsonism patient's Gait Disturbance. ■Methods During 12 days of hospitalization, the patient was treated by acupuncture, pharmaco-acupuncture, moxibustion, herbal medicine, especially Cheongsimyeonjatang-gamibang. In order to assess the change of symptoms, we used a 3-Dimensional(3D) gait analysis system, Unified Parkinson's Disease Rating Scale(UPDRS), analysis of gait video and self-evaluation of discomfort. ■Results After treatment, The improvements of walking pattern were observed in both objective analysis results of gait analysis system and subjective video analysis. And the UPDRS score decreased, especially Part III score decreased more than minimal clinically important difference(MCID). In addition, There was improvement in self assessment of the patient. ■Conclusion This study suggests that Korean medical treatment might be effective in motor disorder of parkinsonism patient.

  • PDF

Method of Walking Surface Identification Technique for Automatic Change of Walking Mode of Intelligent Bionic Leg (지능형 의족의 보행모드 자동변경을 위한 보행노면 판별 기법)

  • Yoo, Seong-Bong;Lim, Young-Kwang;Eom, Su-Hong;Lee, Eung-Hyuk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.81-89
    • /
    • 2017
  • In this paper, we propose a gait pattern recognition method for intelligent prosthesis that enables walking in various environments of femoral amputees. The proposed gait mode changing method is a single sensor based algorithm which can discriminate gait surface and gait phase using only strain gauges sensor, and it is designed to simplify the algorithm based on multiple sensors of existing intelligent prosthesis and to reduce cost of prosthesis system. For the recognition algorithm, we analyzed characteristics of the ground reaction force generated during gait of normal person and defined gait step segmentation and gait detection condition, A gait analyzer was constructed for the gait experiment in the environment similar to the femoral amputee. The validity of the paper was verified through the defined detection conditions and fabricated instruments. The accuracy of the algorithm based on the single sensor was 95%. Based on the proposed single sensor-based algorithm, it is considered that the intelligent prosthesis system can be made inexpensive, and the user can directly grasp the state of the walking surface and shift the walking mode. It is confirmed that it is possible to change the automatic walking mode to switch the walking mode that is suitable for the walking mode.

Change of Gait Pattern of Patients with Ataxic Gait by Cerebellar Infarction in Comparison to Corticospinal Tract Stroke Patients (소뇌경색 환자의 운동기능 회복에 따른 보행 척도의 변화 관찰 연구 : 피질척수로 손상환자와의 비교를 중심으로)

  • Chu, Hongmin;Lee, Young-ung;Kim, Kwang-ho;Lim, Hyeon-seo;Ryu, Ho-sun;Park, Shin-hyeok;Kim, Cheol-hyun;Sung, Kang-keyng;Lee, Sang-kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.2
    • /
    • pp.194-203
    • /
    • 2020
  • Objectives: This study aimed to compare the gait patterns of cerebellar infarction patients with those of corticospinal tract stroke patients through a follow-up of patients with ataxic gait due to cerebellar infarction and corticospinal tract stroke. Methods: We investigated two cases of patients with cerebellar infarction and two cases each of acute or chronic corticospinal tract stroke who were hospitalized at Wonkwang University Gawangju Medical Center from September 1, 2017 to February 15, 2020 based on medical records and gait analyses. The spatiotemporal gait parameters of each patient were measured three times at 2-week intervals except those of the chronic corticospinal tract stroke patients, which were measured twice at a 1-month interval. Results: Spatiotemporal gait parameters, which include velocity, cadence, step length, stride length, and single support, were consistently increased in the cerebellar infarction patients in comparison to the corticospinal tract stroke patients. The stance phase was decreased in all the patients. Conclusions: The cerebellar infarction patients' gait spatiotemporal parameters were found to consistently improve. Moreover, gait analysis can be used to effectively measure improvement of ataxic gait.

Experimental Study on Modifiable Walking Pattern Generation for Handling Infeasible Navigational Commands

  • Hong, Young-Dae;Lee, Bumjoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2368-2375
    • /
    • 2015
  • To accommodate various navigational commands, a humanoid should be able to change its walking motion in real time. Using the modifiable walking pattern generation (MWPG) algorithm, a humanoid can handle dynamic walking commands by changing its walking period, step length, and direction independently. If the humanoid is given a command to perform an infeasible movement, the algorithm substitutes the infeasible command with a feasible one using binary search. The feasible navigational command is subsequently translated into the desired center-of-mass (CM) state. Every sample time CM reference is generated using a zero-moment-point (ZMP) variation scheme. Based on this algorithm, various complex walking patterns can be generated, including backward and sideways walking, without detailed consideration of the feasibility of the navigational commands. In a previous study, the effectiveness of the MWPG algorithm was verified by dynamic simulation. This paper presents experimental results obtained using the small-sized humanoid robot platform DARwIn-OP.

Differences in the Length Change Pattern of the Medial Gastrocnemius Muscle-Tendon Complex and Fascicle during Gait and One-legged and Two-legged Vertical Jumping (보행과 한발·두발 수직점프 수행 시 내측비복근 근-건 복합체와 근섬유다발의 길이 변화 패턴의 차이)

  • Lee, Hae-Dong;Han, Bo-Ram;Kim, Jin-Sun;Oh, Jeong-Hoon;Cho, Han-Yeop;Yoon, So-Ya
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.175-182
    • /
    • 2015
  • Objective : The purpose of this study was to investigate difference in fascicle behavior of the medial gastrocnemius during the locomotion with varying intensities, such as gait and one-legged and two-legged vertical jumping. Methods : Six subjects (3 males and 3 females; age: $27.2{\pm}1.6yrs.$, body mass: $62.8{\pm}9.8kg$, height: $169.6{\pm}8.5cm$) performed normal gait (G) at preferred speed and maximum vertical jumping with one (OJ) and two (TJ) legs. While subjects were performing the given tasks, the hip, knee and ankle joint motion and ground reaction force was monitored using a 8-infrared camera motion analysis system with two forceplates. Simultaneously, electromyography of the triceps surae muscles, and the fascicle length of the medial gastrocnemius were recorded using a real-time ultrasound imaging machine. Results : Comparing to gait, the kinematic and kinetic parameters of TJ and OJ were found to be significantly different. Along with those parameters, change in the medial gastrocnemius (MG) muscle-tendon complex (MTC) length ($50.57{\pm}6.20mm$ for TJ and $44.14{\pm}5.39mm$ for OJ) and changes in the fascicle length of the MG ($18.97{\pm}3.58mm$ for TJ and $20.31{\pm}4.59mm$ for OJ) were observed. Although the total excursion of the MTC and the MG fascicle length during the two types of jump were not significantly different, however the pattern of length changes were found to be different. For TJ, the fascicle length maintained isometric longer during the propulsive phase than OJ. Conclusion : One-legged and two-legged vertical jumping use different muscle-tendon interaction strategies.

Optimal Electrode Displacement for Motion Analysis using Bio-impedance (임피던스 방식의 동작분석을 위한 최적전극 선정)

  • 송철규;변용훈;윤대영;이명권;김거식;송창훈;김경섭;김수찬;김덕원
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2887-2890
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh, knee, and foot, and two potential electrodes are applied to the lateral, medial, and posterior position of lower leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for ankle, knee and hipjoint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements -0.87, 0.957 and 0.80. respectively. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed possibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

  • PDF

A Study on Random Forest-based Estimation Model for Changing the Automatic Walking Mode of Above Knee Prosthesis (대퇴의족의 자동 보행 모드 변경을 위한 랜덤 포레스트 기반 추정 모델 개발에 관한 연구)

  • Na, Sun-Jong;Shin, Jin-Woo;Eom, Su-Hong;Lee, Eung-Hyuk
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.9-18
    • /
    • 2020
  • The pattern recognition or fuzzy inference, which is mainly used for the development of the automatic walking mode change of the above knee prosthesis, has a disadvantage in that it is difficult to estimate with the immediate change of the walking environment. In order to solve a disadvantage, this paper developed an algorithm that automatically converts the walking mode of the next step by estimating the walking environment at a specific gait phase. Since the proposed algorithm should be implanted and operated in the microcontroller, it is developed using the random forest base in consideration of calculation amount and estimated time. The developed random forest based gait and environmental estimation model were implanted in the microcontroller and evaluated for validity.

Optimal Electrode Selection for Detection of Human Leg Movement Using Bio-Impedance (생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정)

  • 송철규;윤대영;이동헌;김승찬;김덕원
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.506-509
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

A Case Report of Korean Medical Treatment on Parkinsonism Patient Complaining of Motor Disorder and Aphonia (한방치료로 운동 기능장애와 실성증이 호전된 파킨슨증후군 환자 치험 1례)

  • Hye-Min, Heo;Kyeong-Hwa, Lee;Ye-Chae, Hwang;Gyu-Ri, Jeon;Seung-Yeon, Cho;Seong-Uk, Park;Jung-Mi, Park;Chang-Nam, Ko
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.13-24
    • /
    • 2022
  • ■Objectives This case study is to report the effectiveness of Korean medicine in Parkinsonism patient's treatment. ■Methods We used the acupuncture, electro-acupuncture, moxibustion, cupping therapy, herbal medicine, especially Palmulgunja-tang to the Parkinsonism patient with motor disorder such as Postural Instability and Gait Difficulty(PIGD) and aphonia. Unified Parkinson's Disease Rating Scale(UPDRS), analysis of gait pattern, voice dB and self-evaluation of speed and volume were used to assess the change of symptoms. ■Results ‌After treatment, the UPDRS score decreased in overall category and the walking pattern has improved. In addition, the improvement was observed in voice volume and in self assessment of the patient. ■Conclusion This case suggests the effect of Korean medical treatment on motor disorder and aphonia in Parkinsonism.