• 제목/요약/키워드: GacA

검색결과 237건 처리시간 0.031초

A Study on DNA Sequences and Mutation of Integrase Region of Korean-type Bovine Leukemia Virus (BLV) pol Gene

  • Kwon, Oh-Sik;Kang, Jung-Soon;Park, Hyun-Jin;Yoo, Min
    • 대한의생명과학회지
    • /
    • 제10권1호
    • /
    • pp.55-63
    • /
    • 2004
  • Bovine leukemia virus (BLV) is a causative agent for lymphoma disease in cattle including cows worldwide. BLV shares similar virion structure and characteristics with other retroviruses. The pol gene of the BLV genome produced reverse transcriptase (RT) and integrase (IN) for important roles for BLV genome integration into host cell chromosomes that is known to be coded in the 3' side of the BLV pol gene (one third portion). In this study, we have sequenced 978 bp in the 3' side of the BLV pol gene from BLV 10C3 in order to determine the BLV IN region of it. And we compared it to the nucleotide sequences of an Australian BLV isolate. As a result, nucleotide sequences of the IN region of the Korean-type BLV pol gene were mutated at a rate of 3.7%. We can confirm that the typical mutations are such as Arg (AGG) $\rightarrow$ Lys (AAG), Thr (ACG) $\rightarrow$ Met (ATG), Ile (ATT) $\rightarrow$ Val (GTT), Asn (ACC) $\rightarrow$ His (CAC), Phe (TTT) $\rightarrow$ Leu (TTG) and Asn (ACC) $\rightarrow$ Asp (GAC). From the analysis of the sequencing data, we were able to determine the zinc-finger-like "HHCC" motif in the amino terminus of BLV IN, that was H-$X_3$-H-$X_{25}-C-X_2$-C. It was also found the DD35E motif in the IN catalytic domain as D-$X_{56}$-D-$X_{35}$-E. It fits very well to the consensus sequences of retroviral IN as well as HHCC motif.

  • PDF

A Homeotic Gene, Hoxc8, Regulates the Expression of Proliferating Cell Nuclear Antigen in NIH3T3 Cell

  • ;;김명희
    • 대한의생명과학회지
    • /
    • 제13권3호
    • /
    • pp.239-244
    • /
    • 2007
  • Hoxc8 is one of the homeotic developmental control genes regulating the expression of many downstream target genes, through which animal body pattern is established during embryonic development. In previous proteomics analysis, proliferating cell nuclear antigen (PCNA) which is also known as cyclin, has been implied to be regulated by Hoxc8 in F9 murine embryonic teratocarcinoma cell. When the 5' upstream region of PCNA was analyzed, it turned out to contain 20 Hox core binding sites (ATTA) in about 1.17 kbp (kilo base pairs) region ($-520{\sim}-1690$). In order to test whether this region is responsible for Hoxc8 regulation, the upstream 2.3 kbp fragment of PCNA was amplified through PCR and then cloned into the pGL3 basic vector containing a luciferase gene as a reporter. When the luciferase activity was measured in the presence of effector plasmid (pcDNA : c8) expressing murine Hoxc8, the PCNA promoter driven reporter activity was reduced. To confirm whether this reduction is due to the Hoxc8 protein, the siRNA against Hoxc8 (5'-GUA UCA GAC CUU GGA ACU A-3' and 5'-UAG UUC CAA GGU CUG AUA C-3') was prepared. Interestingly enough, siRNA treatment up regulated the luciferase activity which was down regulated by Hoxc8, indicating that Hoxc8 indeed regulates the expression of PCNA, in particular, down regulation in NIN3T3 cells. These results altogether indicate that Hoxc8 might orchestrate the pattern formation by regulating PCNA which is one of the important proteins involved in several processes such as DNA replication and methylation, chromatin remodeling, cell cycle regulation, differentiation, as well as programmed cell death.

  • PDF

정수처리공정 중 자연유기물질의 분자량 분포 및 형광특성 변화 모니터링 (Monitoring of Changes in Molecular Weight Distribution and Fluorescence Properties of Dissolved Matter (DOM) in Water Treatment Processes)

  • 박민혜;허진
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.843-849
    • /
    • 2007
  • Monitoring of NOM characteristics is important for improving removal efficiency of natural organic matter (NOM) in water treatment processes. In this study, several NOM characteristics, which include specific UV absorbance (SUVA), total carbonate content, molecular weight distribution, and fluorescence properties, were measured using samples collected from a pilot-scale water treatment plant consisting of coagulation/flocculation (C/F), filtration, ozonation and granular activated carbon (GAC) processes. The highest removal of NOM was observed in C/F and filtration processes as demonstrated by the reduction of dissolved organic carbon (DOC) by 25% and 21%, respectively. Despite nearly no change in DOC, however, the lowest SUVA value and the highest total carbohydrate content were observed in the sample from ozonation process. This indicates that non-degradable aromatic compounds become depleted and biodegradable organic compounds are enriched during the process. Comparison of synchronous fluorescence spectra of the samples showed that ozoation process increased protein-like fluorescence while it decreased fulvic-like and terrestrial humic-like fluorescence. Consistently, a slight peak of protein-like fluorescence was observed in the sample from ozonation process. The greatest change in molecular weight distributions of the samples was observed in C/F process. Comparison of size exclusion chromatogram of the samples revealed that NOM fractions with the molecular weight greater than 2000 Da were reduced by over 90% after C/F process. SUVA values and total carbohydrate content of the samples were well correlated with a ratio of protein-like fluorescence and terrestrial humic-like fluorescence intensities with the correlation coefficients of 0.99 and 0.91, respectively. This suggests that synchronous fluorescence properties of NOM could be used as useful tolls for monitoring changes of some NOM characteristics during water treatment processes.

Frequency and Type of Disputed rpoB Mutations in Mycobacterium tuberculosis Isolates from South Korea

  • Jo, Kyung-Wook;Lee, Soyeon;Kang, Mi Ran;Sung, Heungsup;Kim, Mi-Na;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • 제80권3호
    • /
    • pp.270-276
    • /
    • 2017
  • Background: A disputed rpoB mutation is a specific type of rpoB mutation that can cause low-level resistances to rifampin (RIF). Here, we aimed to assess the frequency and types of disputed rpoB mutations in Mycobacterium tuberculosis isolates from South Korea. Methods: Between August 2009 and December 2015, 130 patients exhibited RIF resistance on the MTBDRplus assay at Asan Medical Center. Among these cases, we identified the strains with disputed rpoB mutation by rpoB sequencing analysis, as well as among the M. tuberculosis strains from the International Tuberculosis Research Center (ITRC). Results: Among our cases, disputed rpoB mutations led to RIF resistance in at least 6.9% (9/130) of the strains that also exhibited RIF resistance on the MTBDRplus assay. Moreover, at the ITRC, sequencing of the rpoB gene of 170 strains with the rpoB mutation indicated that 23 strains (13.5%) had the disputed mutations. By combining the findings from the 32 strains from our center and the ITRC, we identified the type of disputed rpoB mutation as follows: CTG511CCG (L511P, n=8), GAC516TAC (D516Y, n=8), CTG533CCG (L533P, n=8), CAC526CTC (H526L, n=4), CAC526AAC (H526N, n=3), and ATG515GTG (M515V, n=1). Conclusion: Disputed rpoB mutations do not seem to be rare among the strains exhibiting RIF resistance in South Korea.

소석회와 CO2를 이용한 상수관로의 부식제어(II) - 관종별 부식특성 평가 (Corrosion Control in Water Distribution System using Lime and Carbon Dioxide(II) - Evaluation on the Characteristics of Corrosion as a Function of Pipe Material)

  • 이두진;김영일;송영일;박현아
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.379-387
    • /
    • 2008
  • The pH & alkalinity adjustment method by lime and carbon dioxide($CO_2$) for corrosion control in water distribution system was investigated to evaluate the corrosion characteristics of metal pipes, such as galvanized iron, copper, stainless steel, and carbon steel. When the pH in sand filtered and ozone+GAC treated water was increased with lime and $CO_2$ from 7.5 to 8.0, the concentration of residual chlorine decreased at higher pH and longer reaction time; the concentration of trihalomethane increased. The corrosion rate of coupons with corrosion control using lime and carbon dioxide was showed much smaller than those without corrosion control using pilot-scale simulated distribution system. The galvanized iron was corroded much faster than carbon steel, copper, and stainless steel. Especially, copper and stainless steel coupons were hardly corroded. The galvanized iron and carbon steel coupons with corrosion control were produced the corrosion products less than those without corrosion control by the results of environmental scanning electron microscope(ESEM) and energy dispersive x-ray spectroscopy(EDS) analyses. The galvanized iron coupon with pH and alkalinity adjustment by lime and carbon dioxide was detected about 30 percent of zinc, when the carbon steel was detected about 30 percent of calcium by calcium carbonate products formation. For the results of X-ray diffraction(XRD) analyses, the goethite(${\alpha}$-FeOOH) was identified as primary corrosion product of galvanized iron without corrosion control, while the Zinc oxide(ZnO) was found on corrosion products of galvanized iron coupon with corrosion control as the results of EDS analyses. However, the carbon steel corrosion products regardless of corrosion control were composed predominantly of maghemite(${\gamma}-Fe_2O_3$) and hematite(${\alpha}-Fe_2O_3$).

제주도 삼양 수원지 RO 시설 도입 연구 (A Study on the Introduction of RO Facility for Jeju Samyang Water Source)

  • 김우찬;김진근
    • 상하수도학회지
    • /
    • 제29권6호
    • /
    • pp.601-608
    • /
    • 2015
  • Pollutants removal efficiency in pretreatment(GAC filter, multi-media filter, disk filter) and RO facilities was investigated for the Jeju Samyang spring water source where raw water intake has been stopped due to sea water intrusion. In addition, preliminary feasibility analysis was conducted between RO and groundwater intake systems. Turbidity removal in 4 different pretreatment processes was less than 25% due to low concentration of turbidity(i.e., less than 0.21 NTU), while multi-media filter is recommended for the pretreatment facility based on the low organic content in raw water as well as cheaper operation and maintenance cost. The average concentration of $Cl^-$ in raw water was 691.4 mg/L, while that of RO permeate was 9.1 mg/L(i.e., removal efficiency was 98.4%). In addition, TDS removal efficiency was 98.1%, which was quite high. The production cost for RO system($Q=4,000m^3/d$) was $362.1won/m^3$ considering installation, operation and maintenance cost for 30 years. While that of groundwater was $262.6won/m^3$ which was low compared to the RO system. However, it is recommended to introduce RO system for Samyang water source rather than new groundwater development because Samyang water source has been discharged to the sea without any usage, while groundwater can be used for other purpose as a sustainable water source.

수용액 중의 염료 제거를 위한 폐수처리공정의 특성(2) - 반응성염료의 오존산화 및 섬유상활성탄 흡착 처리 - (Characteristics of The Wastewater Treatment Processes for The Removal of Dyes in Aqueous Solution(2) - Ozonation or ACF Adsorption Treatment of Reactive Dyes -)

  • 한명호;허만우
    • 한국염색가공학회지
    • /
    • 제19권3호
    • /
    • pp.26-36
    • /
    • 2007
  • This study was carried out to treat the aqueous solutions containing reactive dyes(RB19, RR120 and RY179) by the Ozone demand flask method and adsorption process using activated carbon fiber(ACF) which are one of the main pollutants in dye wastewater. Ozone oxidation of three kinds of the reactive dyes was examined to investigate the reactivity of dyes with ozone, competition reaction and ozone utilization on various conditions for single- and multi-solute dye solution. Concentration of dyes was decreased continuously with increasing ozone dosage in the single-solute dye solutions. Competition quotient values were calculated to investigate the preferential oxidation of individual dyes in multi-solute dye solutions. Competition quotients(CQi) and values of the overall utilization efficiency, ${\eta}O_3$, were increased at 40mg/l of ozone dosage in multi-solute dye solutions. ACF(A-15) has much larger specific surface area$(1,584m^2/g-ACF)$ in comparison with granular activated carbon adsorbent (F400, $1,125m^2/g-GAC$), which is commonly used, and most of pores were found to be micropores with pore radius of 2nm and below. It was found that RB19 was most easily adsorbed among the dyes in this study. In the case of PCP (p-chlorophenol) and sucrose, which are single component adsorbate, adsorption capacities of ACF(A-15) were in good agreement with the batch adsorption measurement, and saturation time predicted of ACF columns for these components was also well agreed with practically measured time. But in the case of reactive dyes, which have relatively high molecular weight and aggregated with multi-components, adsorption capacities or saturation time predicted were not agreed with practically measured values.

분말 바이오-숯으로부터 중금속 오염수 처리용 바이오-숯 비드 제조 및 적용 (Production Method of Biochar-bead from Biochar Powder and Its Application for the Removal of Heavy Metal)

  • 최유림;노훈;이규범;신복수;주완호;김남국;김진홍;양재규;;조성희;장윤영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권6호
    • /
    • pp.127-132
    • /
    • 2015
  • In this study, biochar-bead, prepared from biochar powder derived from woody biomass, was used for removal cadmium ion in aqueous solution. Various mixing ratios of alginate solution and biochar powder were used for the production of round shape biochar-bead. An optimum mixing ratio was selected as 1.5% alginate solution and 20 wt% biochar. The produced biochar-bead was characterized by SEM, FT-IR, and XRD analyses. The adsorption capacity of Cd(II) by biochar-bead was found to be 9.72 mg/g which was higher than that by GAC and PAC. According to this study, round shape biochar-bead is expected to be used as a media for reactive barrier or water filtration.

과산화수소와 티오황산나트륨을 이용한 정수처리공정에서의 잔류오존 제거 (Removal of residual ozone in drinking water treatment using hydrogen peroxide and sodium thiosulfate)

  • 권민환;김서희;안용태;정유미;조우현;이경혁;강준원
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.481-491
    • /
    • 2015
  • The aim of this study was to evaluate the chemical quenching system for residual ozone and to determine the operating condition for the quenching system. Hydrogen peroxide ($H_2O_2$) and sodium thiosulfate ($Na_2S_2O_3$) were investigated as quenching reagents for ozone removal, and the tendency of each chemical was notably different. In the case of $H_2O_2$, the degradation rate of ozone was increased as the concentration of $H_2O_2$ increase, and temperature and pH value have a significant effect on the degradation rate of ozone. On the other hand, the degradation rate of ozone was not affected by the concentration of $Na_2S_2O_3$, temperature and pH value, due to the high reactivity between the ${S_2O_3}^{2-}$ and ozone. This study evaluates the decomposition mechanism of ozone by $H_2O_2$ and $Na_2S_2O_3$ with consideration for the water quality and reaction time. Furthermore, the removal test for the quenching reagents, which can be remained after reaction with ozone, was conducted by GAC process.

2-Methylisoborneol(2-MIB)제거를 위한 산화 및 흡착공정의 특성 (The Characteristics of Oxidation and Adsorption Processes for 2-Methylisoborneol(2-MIB) Removing)

  • 최근주;김상구;류동춘;신판세;손인식;오광중
    • 한국환경과학회지
    • /
    • 제11권3호
    • /
    • pp.241-246
    • /
    • 2002
  • One of the Musty and earthy smell compounds in raw water is generally attributed to 2-methylisoborneol (2-MIB). It is well known that activated carbon and oxidants such as $O_3$, Cl $O_2$, are effective ways to control 2-MIB. In isotherm equilibrium experiments, 2-MIB in distilled water was much more adsorbed to the activated carbon(A/C) than raw water containing dissolved organic carbon (DOC). The Freundlich constants(k) of distilled water and raw water were 3.36 and 0.049, and 1/n values were 0.80 and 0.42, respectively. The 2-MIB residual rate were Y = $e^{-0}$.55x/~ $e^{-0}$.54x/ with Ozone( $O_3$) dose by 5 minutes contact time at the 241 and 353 ng/L initial concentrations. The 2-MIB residual rate were Y = $e^{-0}$.32x/~ $e^{-0}$.35x/ with Chlorine dioxide(Cl $O_2$) dose by 15 minutes contact time at the 89 and 249 ng/L initial concentrations. 2-MIB was decreased from 1911 ng/L to 569ng/L by post-ozonation(70%removal efficiency) and removal efficiencies of 2-MIB by the following 4 kinds Granular Activated Carbon(GAC) process such as coal base, coconut base, wood base and zeolite+carbon base were 95.8, 89.5, 88.4, and 93.7% respectively.ely.