• 제목/요약/키워드: GT file

검색결과 22건 처리시간 0.028초

모형레진 근관에서 엔진 구동용 니켈-타이타늄 파일의 경사도의 차이에 따른 근관성형력의 비교 (COMPARISON OF SHAPING ABILITY OF NICKEL-TITANIUM ROTARY FILES WITH DIFFERENT TAPER IN SIMULATED RESIN CANALS)

  • 금기연;임경란;정일영;이승종;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.78-84
    • /
    • 2000
  • The aim of this study was to compare shaping ability of nickel-titanium rotary files with different taper in simulated resin canals. The instruments used in this study were GT with .04 taper ProFile with ISO-sized tip, .04 taper ProFile with ISO-sized tip alone, and .02 taper Naviflex file and all canals were prepared by crown-down technique. A total of 30 composite images were made from pre- and post-canal scanned images using Scanjet 4C scanner and Corel photopaint 8.0 and then, prevalence of canal aberrations was measured. The amount of coronal substance the instruments removed was also calculated two-dimensionally on digitized images with the Brain C software to compare the relative enlarging efficiency. Finally, the prepared internal canal form was evaluated three-dimensionally with impression technique. The results were as follows; 1. The incidence of zipping in Naviflex group was significantly high compared to the other two groups(P<.05). 2. The amount of coronal substance the GT combined group removed was significantly larger than the other two groups(P<.05). 3. The GT combined group produced canals with good taper and flow. Under the conditionas of this study, the combined use of larger tapered nickel-titanium rotary files prepared simulated canals safely, efficiently and with good three-dimensional form.

  • PDF

근관 내 불규칙 확장부에서 sealer 적용방법에 따른 충전 효과 평가 (AN IN-VITRO EVALUATION OF SEALER PLACEMENT METHODS IN SIMULATED ROOT CANAL EXTENSIONS)

  • 김성용;이미정;문장원;이세준;유미경
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.31-37
    • /
    • 2005
  • 본 실험은 resin 시편을 이용하여 미리 제작한 근관 내 불규칙 확장부에서 근관 충전용 sealer의 적용 방법에 따른 충전 효과를 평가해 보았다. Endo-training Bloc을 절단하여 사십 개의 규격화된 resin 블록 시편을 획득하였다. 각각의 시편에 $\#20$, 08taper GT 파일을 사용하여 근관을 형성하였고 근관에 손상이 가지 않도록 시편을 양분한 후 양분된 시편의 한 쪽 근관 벽에 다양한 근관 내 확장부를 표현하는 구를 형성하였다. 양분된 시편을 결찰하고 절단 부위를 밀봉하였으며 AH26 sealer를 사용하여 단일 cone 충전법으로 근관을 충전하였다. 네 가지의 근관 충전용 sealer의 적용방법을 이용하였다: A군, $\#20$ K-file : B군, ultrasonic file : C군, lentulo spiral: D군. EZ-Fill bi-directioanl spiral. 모든 시편은 $37^{\circ}\;100\%$ 상대습도에서 1주일간 보관한 후 각 시편을 근단에서 3mm, 4mm, 5mm 부위에서 수평으로 절단하고 각각의 절단면을 위상차현미경과 디지털 카메라를 이용하여 30배율로 관찰하고 촬영하였다. 관찰된 절단면은 scoring system을 이용하여 점수를 산정하였고 각 군 간의 통계적인 유의성 유무는 Fisher's Exact Test를 이용하여 시행하였다.

An in-vitro evaluation of sealer placement methods in simulated root canal extensions

  • Kim, Sung-Young;Lee, Se-Jun;Lee, Kwang-Won
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.579-579
    • /
    • 2003
  • I. Objectives The aim of this study was to evaluate and compare the effectiveness of sealer placement in simulated root canal extensions using the K file, ultrasonic file, lentulo spiral and EZ-Fill. II. Materials and Methods Forty resin blocks were attained from cutting Endo-training Bloc with diamond saw. In each parallelepiped block, the simulated root canal was made with #20, 08taper GT file. After each block was longitudinally split into two halves using mallet and chisel, a standardized groove of 4mm in length, located 2mmapart from the root apex, was prepared on one wall of two halves using the custom-made knife to simulate the canal extensions with various irregularities.(omitted)

  • PDF

네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력 (Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone)

  • 최석동;진명욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.446-453
    • /
    • 2004
  • 하악 대구치 근심치근의 danger zone에서 수종의 전동 니켈-티타늄 파일의 근관성형력을 근관성형 전후 치질 두께의 변화를 측정하여 평가하고자 하였다. 기구에 따라 총 40개의 하악 대구치를 10개씩 $Profile^{\circledR}$, GT Rotary file, Quantec 및 ProTaper 4개 군으로 나누고 각 치아당 2개의 근관을 straight up-and-down과 anticurvature 군으로 나누어 근단부 근관을 모두 30번 크기로 일정하게 확대하였다. 수정된 Bramante법을 사용하였으며 술전 및 술후의 근관 상아질 두께를 치수저 하방 1, 3 및 5 mm지점에서 측정, 이원변량분석법으로 통계분석하였다. 모든 군의 danger zone과 safe zone에서의 straight up-and-down 동작과 anticurvature 동작 사이에는 치근상아질 두께변화에 현저한 차이를 나타내지 않았다 (p > 0.05). ProTaper는 danger zone과 safe zone 모두에서 다른 기구에 비해 많은 량의 근관상아질 삭제를 보였으며 특히 분지부 3 mm 수준에서 현저하였다(p < 0.05).

An in-vitro investigation of appearance of smear layer removal depending on application times and temperature of EDTA

  • Shin, Jang-Shik;Cho, Yong -Bum
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.574.2-574
    • /
    • 2001
  • The objective of this study was to evaluate the effect of EDTA irrigant depending on application times and temperatures. 31 human mature extracted teeth with a single canal and a closed apex were sectioned with microtome in 3mm thickness. They were distributed randomly into 6 groups of 10 specimens each and control group of 2 specimens. Each specimen was prepared with $GT^{TM}$ rotary file (Dentsply, Maillefer Co., Swiss) and irrigated with 3ml sodium hypochlorite every minute. Then smear layer wasn removed with EDTA solution ($PULPDENT^{\circledR}$, PULPDENT Co., USA.) except two control specimens. Specimens of each group were irrigated with 17% EDTA.(omitted)

  • PDF

A comparison of shaping ability of four nickel-titanium rotary instruments in simulated root canals

  • Yun, Hyung-Hwa;Park, Jung-Won;Kim, Sung-Kyo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.588.1-588
    • /
    • 2001
  • The purpose of this study was to compare the root canal shaping ability of four nickel-titanium rotary instruments. Forty eight simulated curved root canals were instrumented in plastic with the Crown-down technique using the $ProTaper^{TM}$ , the ProFile, the $GT^{TM}$, and the Quantec. Canals were instrumented until apical canal were up to size 30 by one operator. Each instrument was used only once and instrumentation time was measured.(omitted)

  • PDF

Comparison of apical seal with or without the use of dentin adhesive system

  • Lee, Min-Jo;Choi, Kyoung-Kyu;Choi, Gi-Woon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.600-600
    • /
    • 2003
  • I. Objectives Effective endodontic obturation must provide a complete, three-dimensional filling of the root canal system, preventing the communication of fluids between root canal and surrounding periapical tissues. The objective of this study was to compare the apical leakage with or without the use of dentin adhesive system. II. Materials and Methods Forth extracted human teeth with single canals were decoronated. Root canals were instrumented using GT rotary files and Profile .04 file up to #40, 1mm short of the apex. After each instrumentation, copious irrigation with 5.25% sodium hypochlorite solution and confirmation of apical patency were performed.(omitted)

  • PDF

수동과 엔진구동형 기구를 이용한 난원형 근관의 형성에 관한 주사전자현미경적 관찰 (A SEM OBSERVATION ON THE EFFICIENCY PREPARATION OF OVAL CANALS USING HAND AND ENGINE-DRIVEN INSTRUMENTS)

  • 송욱;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.141-146
    • /
    • 2004
  • The purpose of this study was to evaluate the efficiency of the preparation of oval canals using hand and engine-driven instruments with SEM observation. Thirty single-rooted teeth with oval canal were used in this study. The teeth were divided into 3 groups. In group A the teeth were instrumented up to a size 35 K-file using RC-prep and irrigated with 5% NaOCl between each file size. In group B. the teeth were instrumented with Profile according to the manufacture's instructions using RC-Prep and irrigated with 5% NaOCl between each file size. In group C. the teeth were instrumented with GT file according to the manufacture's instructions using RC-prep and irrigated with 5% NaOCl between each file size. Then. in all teeth. a final flush of 5ml of distilled water delivered for 30s. Canals were dried with sterile standardized paper points. After preparing the canals, the teeth were sectioned along their mesial and diatal surfaces by using low-speed diamond disc. chisel and mallet. Each root section was then dehydrated in graded concentration of alcohol (70, 80, 90, 100%). mounted on an aluminum stub. sputter-coated with gold-palladium and observed with scanning electron microscope (HITACHI S-4200) in middle and apical area. The results of this study were as follows: 1. In the middle area. group B and group C showed less smear layer than group A and it was statistically significant (p < 0.05). 2. In the middle area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 3. In the apical area, group C showed less smear layer than group A. and it was statistically significant (p < 0.05). 4. In the apical area. group A showed greater smear layer than group B. but it was not statistically significant (p > 0.05). 5. In the apical area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 6. In all groups. the middle area was less smear layer than the apical area. and it was statistically significant (p < 0.05).

모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향 (Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal)

  • 성혜진;하정홍;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.380-386
    • /
    • 2010
  • 연구목적: 니켈-티타늄 금속을 근관치료기구에 도입함으로써 근관형성과정이 매우 단순화되었다. 그러나 이러한 새로운 기구는 단점도 함께 가지고 있는데 그 중 하나가 근관내로 기구가 빨려 들어가는 경향이다. 본 연구에서는 니켈-티타늄 전동파일의 경사도가 screw-in effect에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 총 20개의 S-자형 투명레진블록 (Dentsply-Maillefer) 근관에서 두 군으로 나누어 실험하였는데 Profile군에서는 0.02, 0.04 그리고 0.06 경사도의 Profile (Dentsply-Maillefer)과 0.08, 0.10 그리고 0.12의 경사도의 GT Rotary file (Dentsply-Maillefer)을 사용하였고 K3군에서는 같은 경사도의 K3 file SybronEndo)을 사용하였으며, 분당 300회전의 일정한 속도에서 단일 pecking 동작으로 기구조작을 하였다. 특수한 장치를 고안하였으며 장치내 dynamometer를 이용하여 screw-in effect를 측정하여 one-way ANOVA로 통계처리하고 Tuckey's multiple range test로 사후검정하였다. 결과: Profile 군에서는 큰 경사도의 기구가 더 큰 screw-in force를 나타내었고 (p < 0.05), K3군에서는 0.08, 0.10. 및 0.12 경사도의 기구가 0.04 경사도의 기구에 비해, 0.08 및 0.12 경사도의 기구가 0.06 경사도의 기구에 비해 더 큰 screw-in force를 나타내었다 (p < 0.05). 결론: 기구의 경사도가 클수록 screw-in force가 많이 발생하는 것으로 생각되며, 경사도가 큰 전동화일을 사용시에는 screw-in force를 억제하기 위해 더 많은 주의가 요구될 것으로 생각된다.

Comparison of root canal preparation by three Ni-Ti instruments

  • Shibutani, Takuya;Ozaki, Kazumi;Matsuo, Takashi
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.547-547
    • /
    • 2003
  • The aim of this study was to compare the effects of three Ni-Ti instruments on leaning ability by evaluating the volumetric and morphological changes in the apical 6mm of the root canals before and after preparation, using three-dimensionally reconstructed root canals of extracted human teeth. Forty-five teeth were used in this study. They were opened the chambers and removed the all pulp remnants ultrasonically. Subsequently, the canal wall was coated with silver paste and prepared using ProTaper, ProFile and GT rotary files according to the manufacturers instructions. Before and after root canal preparation, all the specimens were scanned with micro computed tomography and examined the differences in dentine volume removed, canal straightening, the proportion of the unchanged area and canal transportation. Quantitative analysis revealed that instrumentation increased in canal volume ranging between 0.081 and $1.866{\;}\textrm{mm}^3$. On average, the large apical preparation produced by ProTaper demonstrated smaller proportions of unchanged surface areas compared to the two other instruments in small canals. But in large canals like maxillary central incisor, the preparation of ProTaper instruments was not enough. ProTaper instrument was tended to increase more in canal volume as compared with the other two instruments but unchanged area was no significant difference. These results showed that three instruments had similar preparation ability and micro computed tomography in combination with the coated wall of root canal using silver paste is a nondestructive and valuable tool to study root canal geometry and changes after preparations in detail.

  • PDF