• Title/Summary/Keyword: GROUND FIRE

Search Result 346, Processing Time 0.024 seconds

The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer (345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발)

  • An, Y.H.;Park, J.B.;Song, T.S.;Han, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

Dynamic Voltage Compensator using Series and Shunt Inverters (직.병렬 인버터를 이용한 동적전압보상기)

  • Park, Deok-Hui;Lee, Jun-Gi;Han, Byeong-Mun;So, Yong-Cheol;Kim, Hyeon-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.655-662
    • /
    • 1999
  • This paper describes controller design and simulation-model development of a dynamic voltage compensator using series and shunt inverters. The control system was designed using PI controller and vector relationship between the supply voltage and load voltage. A simulation model with EMTP was developed to analyze performance of the controller and the whole system. The simulation and experiment results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system, such as single-line-ground fault, three-line-to-ground fault, and line-to-line fault.

  • PDF

An Analysis of the Tactical Information Exchange between Unmanned Air Vehicles and Ground Fighting Vehicles (무인기 체계와 지상전투차량 간 전술정보 연동 검토)

  • Choi, Il-Ho;Lim, Kyung-Mee;Baek, In-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.794-802
    • /
    • 2017
  • Unmanned Aerial Vehicles (UAVs) have been considered as valuable aerial reconnaissance systems and our army wants capability-enhanced UAVs installed in our territory, hoping that the UAVs will provide enemy information in detail. The enemy information acqcuired by UAVs would be shared by our army's legacy systems. In this article, we made a research on the interoperability between UAVs and Ground Fighting Vehicles (GFVs), laying emphasis on what kinds of tactical information could be exchanged by two different weapon systems. Also, it needs to be addressed that their upper-level commanding systems play a significant role in such operation.

Quantitative Risk Assessment Method for Deep Placed Underground Spaces (대심도지하공간의 정량적위험성 평가기법)

  • Lee, Chang-wook
    • Journal of the Society of Disaster Information
    • /
    • v.6 no.1
    • /
    • pp.92-119
    • /
    • 2010
  • As the necessity to utilize deep-placed underground spaces is increasing, we have to seriously consider the safety problems arising from the U/G spaces which is a restricted environment. Due to the higher cost of land compensation for above ground area and environmental issues, the plan to utilize deep-placed U/G spaces is currently only being established for the construction of U/G road network and GTX. However it is also expected that the U/G spaces are to be used as a living space because of the growing desires to change the above ground areas into the environmentally green spaces. Accordingly it is necessary to protect the U/G environments which is vulnerable against desasters caused by fire, explosion, flooding, terrorism, electric power failure, etc. properly. We want to introduce the principles of the Quantitative Risk Assessment(QRA) method for preparedness against the desasters arising from U/G environments, and also want to introduce an example of QRA which was implemented for the GOTTHARD tunnel which is the longest one in Europe.

Thermal Conductivity Measurement of Sand-Water Mixtures Used for Backfilling Materials of Vertical Boreholes or Horizontal Trenches (지중열교환기 수직 보어홀 및 수평 트렌치 뒤채움재로서 모래-물 혼합물의 열전도도 측정)

  • Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.342-350
    • /
    • 2008
  • This paper presents the results of a laboratory study on the thermal conductivity of sand (silica, quartzite, limestone and masonry sand)-water mixtures used in ground heat exchanger backfilling materials. Nearly 150 tests were performed in a thermal conductivity measuring system (TPSYS02) to characterize the relationships between the thermal conductivity of mixtures and the water content. The results show that the thermal conductivity of mixtures increases with increasing dry density and with increasing water content. The results also show that for constant water contents and a dry density value, the thermal conductivity of mixtures increases with increasing thermal conductivity of solid particles. The measurement results were also compared with the most widely used empirical prediction models for the thermal conductivity of soils.

Development of Vegetation Structure after Forest Fire in the East Coastal Region, Korea (동해안 산불 피해지에서 산불 후 경과 년 수에 따른 식생 구조의 발달)

  • 이규송;정연숙;김석철;신승숙;노찬호;박상덕
    • The Korean Journal of Ecology
    • /
    • v.27 no.2
    • /
    • pp.99-106
    • /
    • 2004
  • We developed the estimation model for the vegetation developmental processes on the severely burned slope areas after forest fire in the east coastal region, Korea. And we calculated the vegetation indices as a useful parameter for the development of land management technique in the burned area and suggested the changes of the vegetation indices after forest fire. In order to estimate the woody standing biomass in the burned area, allometric equations of the 17 woody species regenerated by sprouter were investigated. According to the our results, twenty year after forest fire need for the development to the normal forest formed by 4 stratum structure, tree, sub-tree, shrub and herb layer. The height of top vegetation layer, basal area and standing biomass of woody species show a tendency to increase linearly, and the ground vegetation coverage and litter layer show a tendency to increase logarithmically after forest fire. Among vegetation indices, Ive and Ivcd show a tendency to increase logarithmically, and Hcl and Hcdl show a tendency to increase linearly after forest fire. The spatial variation of the most vegetation factors was observed in the developmental stages less than the first 5 years which were estimated secondary disaster by soil erosion after forest fire. Among vegetation indices, Ivc and Ivcd were the good indices for the representation of the spatial heterogeneity in the earlier developmental stages, and Hcl and Hcdl were the useful indices for the long-term estimation of the vegetation development after forest fire.

Pattern Template Construction of Buried Pipes and Cavities (매립 파이프 및 공동의 패턴 템플레이트 구축)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.80-86
    • /
    • 2017
  • The purpose of this study is to construct a pattern database of pipes and cavities buried in the ground to prevent ground subsidence. To do this, it developed a pattern template algorithm using Open CV and applied it to the results of GPR detection results of tank. As a result, proper pattern database construction was possible. Since the results of this study are based only on limited experimental results, it is expected that more realistic data will be constructed if various field data and detection results of large test beds are supplemented in the future.

Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault (지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구)

  • Kim, Jin-Tae;Lee, Seung-Yong;Park, Sang-Jin;Cha, Han-Ju;Kim, Soo-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

The Change in Fuel Moisture Contents on the Forest Floor after Rainfall

  • Songhee Han;Heemun Chae
    • Journal of Forest and Environmental Science
    • /
    • v.39 no.4
    • /
    • pp.235-245
    • /
    • 2023
  • Forest fuel moisture content is a crucial factor influencing the combustion rate and fuel consumption during forest fires, significantly impacting the occurrence and spread of wildfires. In this study, meteorological data were gathered using a meteorological measuring device (HOBO data logger) installed in the south and north slopes of Kangwon National University Forest, as well as on bare land outside the forest, from November 1, 2021, to October 31, 2022. The objective was to analyze the relationship between meteorological data and fuel moisture content. Fuel moisture content from the ground cover on the south and north slopes was collected. Fallen leaves on the ground were utilized, with a focus on broad-leaved trees (Prunus serrulata, Quercus dentata, Quercus mongolica, and Castanea crenata) and coniferous trees (Pinus densiflora and Pinus koraiensis), categorized by species. Additionally, correlation analysis with fuel moisture content was conducted using temperature (average, maximum, and minimum), humidity (average, minimum), illuminance (average, maximum, and minimum), and wind speed (average, maximum, and minimum) data collected by meteorological measuring devices in the study area. The results indicated a significant correlation between meteorological factors such as temperature, humidity, illuminance, and wind speed, and the moisture content of fuels. Notably, exceptions were observed for the moisture content of the on the north slope and that of the ground cover of Prunus serrulata and Castanea crenata.

Design Considerations for Concrete High-Rise Buildings

  • Chung, Kwangryang;Park, Chulho;Kim, Dohun
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.3
    • /
    • pp.187-193
    • /
    • 2016
  • Busan's Haeundae Resort project, which is currently being constructed by POSCO E&C, comprises the 101-story Landmark Tower and two 85-story residential towers. Presently, foundation and basement construction is complete, with a final completion date set for 2019. Considerations about the construction and design of the three reinforced concrete high-rise buildings will be discussed in this paper.