• Title/Summary/Keyword: GOLD

Search Result 3,633, Processing Time 0.044 seconds

Quality Characteristics of Jelly Added with Pressed Kiwi(Actinidia chinensis var. 'Halla Gold') Juice (참다래 과즙을 첨가한 젤리의 품질 특성)

  • Oh, Hyun-Jeong;Back, Jin-Woo;Lee, Ju-Yeon;Oh, Young-Ju;Lim, Sang-Bin
    • Culinary science and hospitality research
    • /
    • v.19 no.5
    • /
    • pp.110-120
    • /
    • 2013
  • Five types of kiwi jelly were prepared with different rates of pressed kiwi juice and carrageenan, and their quality characteristics such as chemical composition, saccharinity, color, texture, and sensory attributes were measured. There were no significant changes in moisture, crude lipid, carbohydrate, but significant differences were shown in crude ash, crude protein, pH, and acidity. The pH decreased and acidity increased as the amount of added kiwi juice increased. The saccharinity of kiwi jelly increased with increased amount of added kiwi juice. Additionally, the total phenolic content, DPPH radical scavenging activity and content increased with increased amount of added kiwi juice. The hardness, gumminess, and chewiness increased with increased levels of carrageenan. As the amount of added carrageenan increased, the L values of kiwi jelly decreased. Based on the sensory evaluation test, kiwi jelly, JKJ(Jeju Kiwi Jelly)-3 was the best in the flavor, sweetness, texture, and overall acceptability. The chemical composition of JKJ-3 was as follows : moisture $75.1{\pm}0.5%$, carbohydrate $24.2{\pm}0.5%$, crude protein $0.29{\pm}0.05%$, and crude ash $0.44{\pm}0.02%$. The kiwi jelly, JKJ-3 of overall acceptability values in the sensory test for flavor, sweetness, hardness, texture and overall favorite were 3.65, 3.35, 3.35, 3.50 and 3.60, respectively, with the addition of 20% pressed kiwi juice and 2.3% carrageenan.

  • PDF

Characterization of the Stresses in the Luting Cement Layer Affected by Location of the Occlusal Points and Loading Direction on a Full Veneer Crown (유한요소법을 이용한 전부주조관의 교합점 위치와 하중방향이 시멘트층 내 응력에 미치는 영향)

  • Lee, Jung-Hoon;Lee, Kyu-Bok;Lee, Cheong-Hee;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.317-324
    • /
    • 2008
  • The objective of this study was to test effects of (1) where the occlusal contact points locate on a full veneer crown, and (2) which direction the contact forces are directed to, on the stresses within the luting cement layer that might suffer microfracture. A total of 27 finite element models were created for a mandibular first molar, combining 9 different locations of the occlusal contact points and 3 different loading directions. Type 3 gold alloy was used for crown material with a chamfer margin, and the luting cement material was glass ionomer cements in uniform thickness of $75{\mu}m$. Modeled crowns were loaded at 100 N. Different patterns in the cement stress were observed in the vicinity of the buccal and lingual margins. Whereas, the peak stress in buccal margin occurred approximately 0.5 mm away from the external surface, the highest stress in lingual margin was observed at approximately 1 mm. Significantly different distribution of stresses was recorded as a function either of the location of the occlusal contact points or of the loading direction. Higher stresses were produced by more obliquely acting load, and when the loaded point was in the vicinity of the cusp tip.

A literature review on implant abutment and soft tissue response (임플란트 지대주와 임플란트 주위 연조직의 반응에 관한 고찰)

  • Lee, Young-Hoon;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.263-273
    • /
    • 2016
  • In the implant prosthetic procedure, the soft tissue reaction was varied with the material and surface treatment of the abutment. It may be the cause of the peri-implantitis, and hence it can affect the long-term prognosis of the implant prosthesis. Titania and zirconia abutment presented superior biocompatibility and stable soft tissue reaction, while gold alloy abutment showed unfavorable reaction sometimes. A soft tissue reaction can be differed by the surface characteristics even in the same material type. Because rougher surface induces a bacterial attachment, the part contacting a soft tissue should have smooth surface. Additional surface treatment can enhance the cellular response without increasing bacterial attachment. Repeated removal and insertion of the abutment and the shape of the abutment may affect the soft tissue reaction, also. Ultrasonic cleaning and argon plasma cleaning are effective way to clean the retained micro-dust on the customized abutment.

Comparative Analysis of Peptide Nucleic Acid (PNA)-Mediated Real-Time PCR Clamping and DNA Direct Sequencing for EGFR Mutation Detection (EGFR 돌연변이 검출에 있어 PNA-Mediated Real-Time PCR Clamping과 직접 염기서열 분석법의 비교 분석)

  • Kim, Hee-Joung;Kim, Wan-Seop;Shin, Kyeong-Cheol;Lee, Gwan-Ho;Kim, Mi-Jin;Lee, Jeong-Eun;Song, Kyu-Sang;Kim, Sun-Young;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.1
    • /
    • pp.21-27
    • /
    • 2011
  • Background: Although the gold standard method for research trials on epidermal growth factor receptor (EGFR) mutations has been direct sequencing, this approach has the limitations of low sensitivity and of being time-consuming. Peptide nucleic acid (PNA)-mediated polymerase chain reaction (PCR) clamping is known to be a more sensitive detection tool. The aim of this study was to compare the detection rate of $EGFR$ mutation and EGFR-tyrosine kinase inhibitor (TKI) responsiveness according to $EGFR$ mutation status using both methodologies. Methods: Clinical specimens from 112 NSCLC patients were analyzed for $EGFR$ mutations in exons 18, 19, 20, and 21. All clinical data and tumor specimens were obtained from 3 university hospitals in Korea. After genomic DNA was extracted from paraffin-embedded tissue specimens, both PNA-mediated PCR clamping and direct-sequencing were performed. The results and clinical response to $EGFR$-TKIs were compared. Results: Sequencing revealed a total of 35 (22.9%) mutations: 8 missense mutations in exon 21 and 26 deletion mutations in exon 19. PNA-mediated PCR clamping showed the presence of genomic alterations in 45 (28.3%) samples, including the 32 identified by sequencing plus 13 additional samples (6 in exon 19 and 7 in exon 21). Conclusion: PNA-mediated PCR clamping is simple and rapid, as well as a more sensitive method for screening of genomic alterations in $EGFR$ gene compared to direct sequencing. This data suggests that PNA-mediated PCR clamping should be implemented as a useful screening tool for detection of $EGFR$ mutations in clinical setting.

Development of 4D CT Data Generation Program based on CAD Models through the Convergence of Biomedical Engineering (CAD 모델 기반의 4D CT 데이터 제작 의용공학 융합 프로그램 개발)

  • Seo, Jeong Min;Han, Min Cheol;Lee, Hyun Su;Lee, Se Hyung;Kim, Chan Hyeong
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.4
    • /
    • pp.131-137
    • /
    • 2017
  • In the present study, we developed the 4D CT data generation program from CAD-based models. To evaluate the developed program, a CAD-based respiratory motion phantom was designed using CAD software, and converted into 4D CT dataset, which include 10 phases of 3D CTs. The generated 4D CT dataset was evaluated its effectiveness and accuracy through the implementation in radiation therapy planning system (RTPS). Consequently, the results show that the generated 4D CT dataset can be successfully implemented in RTPS, and targets in all phases of 4D CT dataset were moved well according to the user parameters (10 mm) with its stationarily volume (8.8 cc). The developed program, unlike real 4D CT scanner, due to the its ability to make a gold-standard dataset without any artifacts constructed by modality's movements, we believe that this program will be used when the motion effect is important, such as 4D radiation treatment planning and 4D radiation imaging.

INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON THE PRELOAD OF IMPLANT ABUTMENT SCREWS (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구)

  • Choi Jin-Uk;Jeong Chang-Mo;Jeon Young-Chan;Lim Jang-Seop;Jeong Hee-Chan;Eom Tae-Gwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.229-242
    • /
    • 2006
  • Statement of problem: In order to increase preload with reducing the friction coefficient, abutment screws coated with pure gold and Teflon as dry lubricant coatings have been introduced. But the reported data indicate that if screw repeated tightening and loosening cycle, an efficiency of increasing preload was decreased by screw surface wearing off. Purpose: This study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on the preload of abutment screws and the stability of coating surface after repeated closures. Material and method: The rotational values of abutment screws and the compressive forces between abutment and fixture were measured in implant systems with three different joint connections, one external butt joint and two internal cones. Moreover the stability and the alteration of coating surface were examined by comparison of the compressive force and the removable torque values during 10 consecutive trials, observation with scanning electron microscope and analyzed the elemental composition with energy dispersive x-ray spectroscopy Results and conclusion: 1. Application of coating resulted in significant increase of compressive force in all implant systems(P<.05). The increasing rate of compressive force by coating in external butt joint was gloater than those in internal cones (P<.05). 2. Coated screw showed the significant additional rotation compared to non-coated screw in all implant systems (P<.05). There were no significant differences in the increasing rate of rotation among implant systems (P>.05). 3. Removable torque values were greater with non-coated screw than that with coated screw (P<.05). 4. Coated screw showed insignificant variations in the compressive forces during 10 consecutive trials(P>.05) 5. After repeated trials, the surface layer of coated screw was maintained relatively well. However surface wearing and irregular titanium fragments were found in non-coated screw.

THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS (주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구)

  • Oh Su-Yeon;Vang Mong-Sook;Yang Hong-So;Park Sang-Won;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

A STUDY ON THE STRESS DISTRIBUTION OF CANTILEVER BRIDGE UNDER MAXIMUM BITE FORCE AND FUNCTIONAL BITE FORCE USING THREE DIMENSIONAL FINITE ELEMENT METHOD (최대교합 및 기능교합시 하악구치부 연장가공의치에 발생하는 응력에 대한 삼차원 유한요소법적 연구)

  • Park Chang-Keun;Lee Sun-Hyung;Chung Hun-Young;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.4
    • /
    • pp.484-514
    • /
    • 1994
  • Cantilever bridge is widely used by mny clinicians, but its worst mechanical character, so called Class I lever system, makes dentists hesitate to restore the missing tooth with it. Therefore it is important to study stress of the cantilever bridge. In this study, two models of cantilever bridges that restores the missing mandibular second molar with two abutment teeth were constructed. One model was a type of cantilever bridge supported by a normal alveolar bone, the other one was supported by an alveolar bone resorbed to its 1/3 of root length. Maximum bite force(550N) and funtional maximum bite force(300N) were vertically applied to the distal end of the pontic, distal 1/3, and distal half of the pontic. And each force was also applied to centric occlusal contacts as a distributed force. Total 16 loading cases were compared and analyzed with 3-dimensional finite element method. The results were as follows: 1. The stress was concentrated on the joint of the pontic and the retainer, grooves, and distal cervical margin of the posterior retainer. 2. In case of maximum bite force(550N) at the end of the pontic, the risk of fracture at the joint of the pontic and the retainer was high. 3. In case of distributed force in centric occlusion and functional maximum bite force(300N), the stresses were less than the yield strength of the type VI gold for any loading cases. 4. In case of alveolar bone resorption, the occlusal force to the cantilever pontic caused more stress on the root apex and less stress on the alveolar crest region of the distal surface of the posterior abutment. 5. In case of alveolar bone resorption, the displacement was larger than that of normal alveolar bone in all loading cases.

  • PDF

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

The Effects of Self-Efficacy Promoting Pulmonary Rehabilitation Program in Out-Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 외래환자에서 자기효능감증진 호흡재활프로그램의 효과)

  • Jung, Jang Hee;Kim, Jung Youp
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.6
    • /
    • pp.533-546
    • /
    • 2006
  • Background: The aim of this study was to determine the effectiveness of self-efficacy promoting pulmonary rehabilitation in patients with chronic obstructive pulmonary disease (COPD). Methods: thirty six patients, with clinically stable COPD were randomly assigned: 18 to a rehabilitation group and another 18 as a control group, The subjects participated in a the self-efficacy promoting pulmonary rehabilitation program for 8 weeks. This program consisted of education, breathing retraining, exercise training, relaxation and counseling. The control group received education only. The outcome variables were self-efficacy, dyspnea, exercise endurance, pulmonary function, and quality of life. Dyspnea was measured using the modified Borg scale. Exercise endurance was measured by the six minute walking distance. The quality of life was measured by the quality of life index for pulmonary disease patients. Results: In the rehabilitation group after performing the self-efficacy promoting pulmonary rehabilitation program, the self-efficacy score, exercise endurance, and quality of life score were higher than the control group (p=0.007, p=0.038, and p=0.039, respectively). and the exertional dyspnea score was significantly lower than controls(p=0.045). However, the dyspnea score and FEV1 were similar after performing the self-efficacy promoting pulmonary rehabilitation program. Conclusion: The self-efficacy promoting pulmonary rehabilitation program is effective to in improve self-efficacy, exertional dyspnea, exercise endurance and quality of life in patients with COPD.