ANALYSIS OF CHARGE COLLECTION EFFICIENCY FOR A PLANAR CdZnTe DETECTOR

  • Kim, Kyung-O;Kim, Jong-Kyung;Ha, Jang-Ho;Kim, Soon-Young
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.723-728
    • /
    • 2009
  • The response property of the CZT detector ($5{\times}5{\times}5\;mm^3$), widely used in photon spectroscopy, was evaluated by considering the charge collection efficiency, which depends on the interaction position of incident radiation, A quantitative analysis of the energy spectra obtained from the CZT detector was also performed to investigate the tail effect at the low energy side of the full energy peak. The collection efficiency of electrons and holes to the two electrodes (i.e., cathode and anode) was calculated from the Hecht equation, and radiation transport analysis was performed by two Monte Carlo codes, Geant4 and MCNPX. The radiation source was assumed to be 59.5 keV gamma rays emitted from a $^{241}Am$ source into the cathode surface of this detector, and the detector was assumed to be biased to 500 V between the two electrodes. Through the comparison of the results between the Geant4 calculation considering the charge collection efficiency and the ideal case from MCNPX, an pronounced difference of 4 keV was found in the full energy peak position. The tail effect at the low energy side of the full energy peak was confirmed to be caused by the collection efficiency of electrons and holes. In more detail, it was shown that the tail height caused by the charge collection efficiency went up to 1000 times the pulse height in the same energy bin at the calculation without considering the charge collection efficiency. It is, therefore, apparent that research considering the charge collection efficiency is necessary in order to properly analyze the characteristics of CZT detectors.

양성자 빔을 이용한 3차원 마이크로 구조물 가공 (Manufacturing of Three-dimensional Micro Structure Using Proton Beam)

  • 이성규;권원태
    • 대한기계학회논문집B
    • /
    • 제39권4호
    • /
    • pp.301-307
    • /
    • 2015
  • MC-50 사이클로트론에서 방출되는 양성자 빔은 직경이 2-3 mm 의 가우시안 분포를 가진다. 이렇게 넓게 조사되는 양성자 빔은 작은 스팟과 정밀한 위치정밀도를 요구하는 반도체 식각, 마이크로 머시닝 등에는 사용될 수 없다. 본 연구에서는 좀 더 경제적인 대안으로 양성자 빔을 마이크로 홀에 통과시켜 수십 ${\mu}m$ 의 직경을 가지도록 조형하는 방법을 제시하였다. 양성자 빔의 조형을 위하여 평균 직경 $21{\mu}m$, 두께 9mm 의 세장비 428 의 마이크로 홀을 제작하였다. 마이크로 홀과 양성자 빔을 정밀하게 정렬하여 양성자 빔을 조형하였다. 이렇게 조형된 양성자 빔을 이용하여 수십 ${\mu}m$ 크기의 마이크로 구조물의 가공성 확인 실험을 실시하였다. 또한 GEANT4 를 이용한 전산모사를 이용하여 해석한 후, 실험결과와 비교하고 분석하였다. 본 연구를 통하여 MC-50 사이클로트론이 조형 장치와 함께 20 마이크론 대의 3 차원 구조물 제작을 위한 마이크로 공정기술에의 사용 가능성을 확인하였다.

A detector system for searching lost γ-ray source

  • Khan, Waseem;He, Chaohui;Cao, Yu;Khan, Rashid;Yang, Weitao
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1524-1531
    • /
    • 2020
  • The aim of this work is to develop a Geiger-Muller (GM) detector system for robot to look for a radioactive source in case of a nuclear emergency or in a high radiation environment. In order to find a radiation source easily, a detector system, including 3 detectors, was designed to search γ-ray radiation sources autonomously. First, based on GEANT4 simulation, radiation dose rates in 3 Geiger-Muller (GM) counters were simulated at different source-detector distances, distances between detectors and angles. Various sensitivity analyses were performed experimentally to verify the simulated designed detector system. A mono-energetic 137Cs γ-ray source with energy 662 keV and activity of 1.11 GBq was used for the observation. The simulated results were compared with the experimental dose rate values and good agreements were obtained for various cases. Only based on the dose rates in three detectors, the radiation source with a specific source activity and angle was localized in the different location. A method was adopted with the measured dose rates and differences of distances to find the actual location of the lost γ-ray source. The corresponding angles of deviation and detection limits were calculated to determine the sensitivity and abilities of our designed detector system. The proposed system can be used to locate radiation sources in low and high radiation environments.

GAGG 섬광체 물질을 적용한 감마카메라 영상의 유용성 평가: 몬테카를로 시뮬레이션 연구 (Usefulness of New GAGG Scintillation Detector for Gamma Camera : A Monte Carlo Simulation Study)

  • 김정수;박찬록
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.511-515
    • /
    • 2020
  • 본 연구의 목적은, 새롭게 제안된 Gadolinium Aluminum Gallium Garnet (GAGG) 기반 감마카메라를 Geant 4 Application for Tomographic Emission (GATE) 모사 도구(simulation tool)를 통해 설계하고, National Electrical Manufacturers Association International Electrotechnical Commission에서 제작한 몸통 팬텀 모사를 통해 기존의 사용되고 있는 NaI(Tl) 섬광체 기반 감마카메라 시스템과 99mTc 방사성동위원소를 이용해 900 초 동안 영상을 획득했다. Contrast to noise ratio (CNR) 과 Coefficient of variation (COV) 의 정량분석 방법을 사용해 해당 관심영역에 대해 영상을 평가하였다. CNR 과 COV 결과에 따라, 결과적으로 GAGG 기반 감마 영상의 질이 우수함을 확인하였다.

치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구 (Feasibility study of insertable miniature x-ray source for dental imaging)

  • 조성호;김소영;안소현;임수미;이레나
    • 한국방사선학회논문지
    • /
    • 제6권1호
    • /
    • pp.39-45
    • /
    • 2012
  • 기존 구내 치근단 촬영용 장치는 환자 피폭선량, 촬영시 고통 등의 문제점을 지니고 있다. 본 연구에서는 이러한 문제점을 해결하기 위한 신개념의 삽입형 초소형 X선 시스템의 가능성을 검증하였다. 먼저 초소형 X선 튜브에 사용될 콜리메이터와 필터를 설계하기 위하여 Geant4를 이용하여 최적의 콜리메이터 두께와 필터 두께를 결정하였으며 CdTe 검출기와 PX4 모듈을 이용하여 결정된 두께에서의 X선 스펙트럼을 확인하였다. 또한 기존 상용화된 치근단 촬영장치와 XOFT사의 초소형 X선 튜브를 이용하여 제작된 치아 팬텀에 대한 영상을 획득하였다. 그 결과 제안된 신개념의 삽입형 초소형 X선 시스템은 기존 시스템과 유사한 영상의 질을 나타내었다. 이는 향후 치근단 촬영용 장치를 비롯하여 다양한 응용부위에 활용할 수 있음을 나타낸다.

Measurement of Neutron Production Double-differential Cross-sections on Carbon Bombarded with 430 MeV/Nucleon Carbon Ions

  • Itashiki, Yutaro;Imahayashi, Youichi;Shigyo, Nobuhiro;Uozumi, Yusuke;Satoh, Daiki;Kajimoto, Tsuyoshi;Sanami, Toshiya;Koba, Yusuke;Matsufuji, Naruhiro
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.344-349
    • /
    • 2016
  • Background: Carbon ion therapy has achieved satisfactory results. However, patients have a risk to get a secondary cancer. In order to estimate the risk, it is essential to understand particle transportation and nuclear reactions in the patient's body. The particle transport Monte Carlo simulation code is a useful tool to understand them. Since the code validation for heavy ion incident reactions is not enough, the experimental data of the elementary reaction processes are needed. Materials and Methods: We measured neutron production double-differential cross-sections (DDXs) on a carbon bombarded with 430 MeV/nucleon carbon beam at PH2 beam line of HIMAC facility in NIRS. Neutrons produced in the target were measured with NE213 liquid organic scintillators located at six angles of 15, 30, 45, 60, 75, and $90^{\circ}$. Results and Discussion: Neutron production double-differential cross-sections for carbon bombarded with 430 MeV/nucleon carbon ions were measured by the time-of-flight method with NE213 liquid organic scintillators at six angles of 15, 30, 45, 60, 75, and $90^{\circ}$. The cross sections were obtained from 1 MeV to several hundred MeV. The experimental data were compared with calculated results obtained by Monte Carlo simulation codes PHITS, Geant4, and FLUKA. Conclusion: PHITS was able to reproduce neutron production for elementary processes of carbon-carbon reaction precisely the best of three codes.

Geant4를 활용한 국제우주정거장 내의 조직등가비례계수기 모의 실험 (SIMULATION OF THE TISSUE EQUIVALENT PROPORTIONAL COUNTER IN THE INTERNATIONAL SPACE STATION WITH GEANT4)

  • 표정현;이재진;남욱원;김성환;김현옥;임창휘;박귀종;이대희;박영식;문명국
    • 천문학논총
    • /
    • 제27권3호
    • /
    • pp.81-86
    • /
    • 2012
  • The International Space Station (ISS) orbits the Earth within the inner radiation belt, where high-energy protons are produced by collisions of cosmic rays to the upper atmosphere. About 6 astronauts stay in the ISS for a long period, and it should be important to monitor and assess the radiation environment in the ISS. The tissue equivalent proportional counter (TEPC) is an instrument to measure the impact of radiation on the human tissue. KASI is developing a TEPC as a candidate payload of the ISS. Before the detailed design of the TEPC, we performed simulations to test whether our conceptual design of the TEPC will work propertly in the ISS and to predict its performance. The simulations estimated that the TEPC will measure the dose equivalent of about 1:1 mSv during a day in the ISS, which is consistent with previous measurements.

Geant4를 이용한 STEIN 검출기의 입자 분리 검출 모의실험 예비 결과 분석

  • 박성하;김용호;우주;선종호;진호;이동훈
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.212.2-212.2
    • /
    • 2012
  • 지구 자기권에 존재하는 플라즈마 입자의 다중관측을 목적으로 개발된 초소형 탑재체 STEIN (SupraThermal Electron, Ion, Neutral) 은 경희대학교와 UC Berkeley가 공동으로 개발 중인 3대의 초소형 과학위성 TRIO-CINEMA (TRiplet Ionosphere Observatory - Cubesat for Ion, Neutral, Electron and MAgnetic fields) 에 탑재될 입자 검출기이다. 32개의 픽셀로 이루어진 STEIN 검출기는 2~300 keV의 전자, 4~300 keV의 이온과 중성입자(Energetic Neutral Atom: ENA) 를 분리 계측할 목적으로 설계되었으며, 하전입자가 정전장 편향기를 통과하여 서로 다른 검출기 픽셀에 도달함으로써 전자와 이온, 중성입자를 분리하여 계측할 수 있도록 하였다. 한편, STEIN 구조물에서 발생한 2차 입자의 검출을 방지하기 위해 정전 편향기 사이에 차단날(blade)을 설계하였다. 본 연구에서는 STEIN 모의실험 예비 결과로써 전기장에 크기 및 차단날에 의한 하전입자의 궤적과 이에 따른 분리 계측 성능을 알아보고자 Geant4 (GEometry ANd Tracking)를 사용하여 검출기 픽셀에 입사하는 전자의 초기 위치를 분석하였다. 전자의 입사 위치는 검출기로부터 5 cm 전방에서 6 mm * 20 mm 범위 내에서 무작위로 생성하여 검출기의 방향으로 수직 입사하였다. 분석 결과 전자들은 전기장의 방향에 따라 편향되는 결과를 보였으며, 저에너지 전자는 강한 전기장의 영향으로 차단날에 의해 차폐되어 검출되지 않았다. 따라서 전기장의 크기와 차단날에 따른 입자 분리 검출이 가능함을 본 모의실험을 통해 확인하였으며, STEIN 운용 시 입자 분리 검출 및 결과 분석 기반으로 본 연구 결과를 사용될 수 있을 것으로 기대된다.

  • PDF

Analysis of Dose Distribution According to the Initial Electron Beam of the Linear Accelerator: A Monte Carlo Study

  • Park, Hyojun;Choi, Hyun Joon;Kim, Jung-In;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.10-19
    • /
    • 2018
  • Background: Monte Carlo (MC) simulation is the most accurate for calculating radiation dose distribution and determining patient dose. In MC simulations of the therapeutic accelerator, the characteristics of the initial electron must be precisely determined in order to achieve accurate simulations. However, It has been computation-, labor-, and time-intensive to predict the beam characteristics through predominantly empirical approach. The aim of this study was to analyze the relationships between electron beam parameters and dose distribution, with the goal of simplifying the MC commissioning process. Materials and Methods: The Varian Clinac 2300 IX machine was modeled with the Geant4 MC-toolkit. The percent depth dose (PDD) and lateral beam profiles were assessed according to initial electron beam parameters of mean energy, radial intensity distribution, and energy distribution. Results and Discussion: The PDD values increased on average by 4.36% when the mean energy increased from 5.6 MeV to 6.4 MeV. The PDD was also increased by 2.77% when the energy spread increased from 0 MeV to 1.019 MeV. In the lateral dose profile, increasing the beam radial width from 0 mm to 4 mm at the full width at half maximum resulted in a dose decrease of 8.42% on the average. The profile also decreased by 4.81% when the mean energy was increased from 5.6 MeV to 6.4 MeV. Of all tested parameters, electron mean energy had the greatest influence on dose distribution. The PDD and profile were calculated using parameters optimized and compared with the golden beam data. The maximum dose difference was assessed as less than 2%. Conclusion: The relationship between the initial electron and treatment beam quality investigated in this study can be used in Monte Carlo commissioning of medical linear accelerator model.

다양한 두께의 부가 여과판을 적용한 X-선 영상에서의 Total Variation 알고리즘 적용 : GATE 시뮬레이션 연구 (Application of Total Variation Algorithm in X-ray Phantom Image with Various Added Filter Thickness : GATE Simulation Study)

  • 박태일;장수종;이영진
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.773-778
    • /
    • 2019
  • X-선을 이용한 영상은 진단에 필수적인 요소지만 영상에서의 noise발생이 불가피하다. 이를 보완하기 위해 환자의 피폭선량은 낮추면서 영상의 질은 높여주는 total variation (TV) 알고리즘이 제시되었다. 본 연구의 목적은 시뮬레이션을 통해 부가 여과판의 두께에 따라 방사선 영상 촬영 시 영상의 화질에 미치는 영향을 확인하고, TV 알고리즘의 유용성을 평가하는 것이다. 부가 여과판의 두께변화에 따른 각 알고리즘 적용 시 Geant4 Application for Tomographic Emission (GATE) 시뮬레이션 영상을 이용하여 Polymethylmethacrylate(PMMA) 팬텀의 실제 크기, 모양과 재질을 동일하게 하고 대조도 대 잡음비 (contrast to noise ratio, CNR)과 변동계수 (coefficient of variation, COV)값을 비교하였으며 그 결과 TV 알고리즘 적용 시 CNR 값이 가장 높고 COV 값이 가장 낮다는 것을 확인할 수 있었다. 또한, 모든 알고리즘에서 0 mmAl을 사용할 경우 가장 우수한 CNR과 COV값을 얻을 수 있었다.