• Title/Summary/Keyword: GD

Search Result 1,153, Processing Time 0.027 seconds

Comparison between analytic and numerical approaches to calculate screening current induced field in HTS magnet

  • Bang, Jeseok;Kim, Seokho;Kim, Jaemin;An, Soobin;Im, Chaemin;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.2
    • /
    • pp.45-49
    • /
    • 2019
  • This paper reports comparison between analytic and numerical simulation approaches for calculation of screening current and screening current induced field in a high temperature superconductor magnet. Bean slab model is adopted to calculate screening current and SCF analytically, while the finite element method numerically. A case study of screening current and SCF calculation are conducted with a magnet, a 7 T 68 mm cold-bore multi-width no-insulation GdBCO magnet built and tested by Massachusetts Institute of Technology Francis Bitter Magnet Laboratory. In this study, we assume the magnet is dunked in liquid nitrogen at 77 K. Furthermore, the simulation results are compared in terms of computation time and accuracy. Finally, discussion on the different methods together with the comparison between the calculations and experiment is provided.

Implantation of DC Optical Current Sensor Based on Faraday Effect for HVDC (페러데이 효과를 이용한 특고압 직류전송용 광전류 센서 구현)

  • Kim, Kwang Taek;Chung, Dae Won;Kim, Young Soo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.187-190
    • /
    • 2019
  • We proposed and demonstrated DC(direct current) optical current sensor based on Faraday effect for HVDC(high voltage direct current). The RIG((Bi1.3Gd0.43Y1.27)Fe5O12) was adopted as Faraday device because of its high Verdet constant and good thermal stability. The differential amplification scheme for signal processing was present. The sensor showed high linear response for the input current. Measurement range of the sensor was 0~200A and measurement error was less than 1%.

Acute combined central and peripheral nervous system demyelination: a case report

  • Roh, Young Eun;Kim, Young Mi
    • Kosin Medical Journal
    • /
    • v.33 no.2
    • /
    • pp.257-262
    • /
    • 2018
  • Guillain-$Barr{\acute{e}}$ syndrome (GBS) and acute disseminated encephalomyelitis (ADEM) are demyelinating neurologic disorders with different target organs. Although they share similar pathogenetic mechanism, reports of simultaneous occurrence of the 2 disorders are rare. A 2 year 6 month old girl visited our hospital for fever, cough, and general weakness. Although the muscle power of extremities showed mild weakness and voiding difficulty, initial deep tendon reflex of both knees and ankles was normal. A nerve conduction study to evaluate the weakness revealed the absence of F waves. Cerebrospinal fluid analysis demonstrated pleocytosis with lymphocyte predominance and elevated protein levels. Magnetic resonance imaging showed abnormal T2 hyperintensity in pons, medulla and spinal cord. Serum anti-GD1b antibody was positive. Based on clinical findings, laboratory findings, nerve conduction study, and neuroimaging, the diagnosis of GBS and ADEM was made. This is the first case of GBS accompanied by ADEM in Korea.

The Impact of Board of Directors' Characteristics on Firm Performance: A Case Study in Jordan

  • KANAKRIYAH, Raed
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.3
    • /
    • pp.341-350
    • /
    • 2021
  • This study tested the effect of the board of directors' (BOD) characteristics on the corporate performance of the Jordanian industrial and service companies listed on the Amman Stock Exchange (ASE) during the period 2015-2019. The characteristics of the BOD were measured through the following variables: MO = managerial ownership; CEODU = CEO duality; BI = board independence; GD = gender diversity; ND = nationality diversity; AE = advanced education; BM = board meetings; BSIZ = board size; CSIZ = corporate size; CA = corporate age. The corporate performance was measured by return on assets (ROA) and return on equity (ROE). The corporate size and corporate age were used as control variables. The study sample consisted of 85 industrial and service companies with 425 observations to identify the nature of the effect of the BOD characteristics on performance. This study applied time-series data (panel data), and the multiple linear regression method was used to achieve study objectives. Results showed a positive effect of the study variables on performance, while the corporate age and the education level (BOD members) have a negative effect on performance.

Effect of gadolinium and boron addition on the texture development and magnetic properties of 23Cr-10NiCu duplex stainless steels

  • Baik, Youl;Kang, Bo Kyeong;Choi, Yong;Woo, Wan Chuck
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1887-1892
    • /
    • 2021
  • The effect of gadolinium and boron on the texture development and magnetic properties of the texture controlled 23Cr-10NiCu duplex stainless steels were studied to develop a high performance neutron and electromagnetic shielding material. The 23Cr-10NiCu base alloy is composed of 60% of austenite and 40% of ferrite, whereas, the 23Cr-10NiCu-0.5Gd-0.8B modified alloy is composed of 66% of austenite, 27% of ferrite and 7% of CrFeB intermetallic compounds. The gadolinium and boron addition to the 23Cr-10NiCu base alloy increased mechanical properties. Microstructure observation showed that the small addition of 0.5 wt% gadolinium and 0.8 wt% boron to the alloy retarded to form texture at the same hot rolling conditions, and improved the maximum magnetism, residual magnetism and coercive force about 3%, 122% and 120%, respectively.

The study on Luminescent properties of Red Emitting phosphor for plasma display panel (PDP용 적색형광체의 발광특성에 관하여)

  • Choe, J.I.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.6
    • /
    • pp.665-670
    • /
    • 1999
  • PDP용 적색형광체는 penning가스(Ne 및 5% Xe혼합가스)에 의해 방출되는 147nm파장에서 쉽게 여기되어 논은 양자효율을 주는 물질로 이루어지는데 본 실험은 발광효율을 높이기 위하여 $Y_2$$O_3$:Eu, $(Y,Gd)_2$$O_3$:Eu 및 $(Y,Cd)BO_3$:Eu를 공침법으로 합성하여 부활제인 $Bu^{3+}$ /의 농도, Flux첨가에 따른 미시조직의 변화등을 여기 방출 스펙트럼을 통해 발광효율을 조사하여 다음과 같은 결론을 얻었다. $Y_2$$O_3$:Eu 형광체 합성시 최적조정은 $Y_2$$O_3$에 대한 $Eu_2$$O_3$의 몰비는 5:1, $BaCO_3$ 첨가시 몰비는 15:1로 나타났으며 2차 소성시 $1200^{\circ}C$이상에서 1~3$\mu\textrm{m}$의 구형입상이 형성되었으며 입자의 크기, 형상은 발광특성에 영향을 미쳤다. 또 $Eu^{ 3+}$ 농도는 7wt%가 최적조건으로 나타났다.

  • PDF

REE Mineralization and Geology of Chulmasan Area, Taean, Chungchungnamdo (충남 태안 철마산 일대의 지질 및 희토류 광화작용)

  • Yoo, Bong Chul
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.127-143
    • /
    • 2019
  • The geology of the Chulmasan area consists of Precambrain Sogeunri formation, granitic gneiss, foliated biotite granite, foliated mica granite, basic dyke and acidic dyke. REE mineralization in the area occurs at granitic gneiss and foliated mica granite. Minerals with minor amounts of REE and Th from granitic gneiss and foliated mica granite are zircon ($Y_2O_3$ 0.00~1.18 wt.%, $Gd_2O_3$ 0.00~0.59 wt.%, $Er_2O_3$ 0.00~0.22 wt.%, $Yb_2O_3$ 0.00~0.34 wt.%, $Lu_2O_3$ 0.00~0.48 wt.%, $ThO_2$ 0.00~0.33 wt.%), thorianite ($Nd_2O_3$ 0.00~0.24 wt.%, $Lu_2O_3$ 0.00~0.26 wt.%), berthierine ($La_2O_3$ 0.04~0.26 wt.%, $Nd_2O_3$ 0.00~0.20 wt.%, $Tb_2O_3$ 0.04~0.12 wt.%, $Dy_2O_3$ 0.17~0.26 wt.%, $Er_2O_3$ 0.33~0.44 wt.%, $Lu_2O_3$ 0.00~0.19 wt.%, $ThO_2$ 0.61~0.93 wt.%), chlorite ($La_2O_3$ 0.44~0.68 wt.%, $Ce_2O_3$ 0.12~0.13 wt.%, $Nd_2O_3$ 0.31~0.44 wt.%, $Eu_2O_3$ 0.03~0.08 wt.%, $Dy_2O_3$ 0.09~0.21 wt.%, $Ho_2O_3$ 0.04~0.14 wt.%, $Er_2O_3$ 0.18~0.32 wt.%, $Lu_2O_3$ 0.07~0.21 wt.%, $ThO_2$ 0.00~0.97 wt.%), biotite ($Nd_2O_3$ 0.02~0.08 wt.%, $Gd_2O_3$ 0.07~0.08 wt.%, $Tb_2O_3$ 0.02~0.07 wt.%, $Dy_2O_3$ 0.35~0.43 wt.%, $Ho_2O_3$ 0.15~0.26 wt.%, $Er_2O_3$ 0.24~0.28 wt.%, $Yb_2O_3$ 0.06~0.18 wt.%, $ThO_2$ 0.00~0.12 wt.%), orthoclase ($Dy_2O_3$ 0.05~0.12 wt.%, $Ho_2O_3$ 0.05~0.06 wt.%, $Er_2O_3$ 0.28 wt.%, $Yb_2O_3$ 0.06~0.12 wt.%) and plagioclase ($Ho_2O_3$ 0.01~0.03 wt.%, $Er_2O_3$ 0.10~0.27 wt.%, $ThO_2$ 0.11~0.13 wt.%). REE minerals (bastnaesite and fergusonite) were sealed fractures in mainly fledspar, mica, zircon, apatite and ilmenite. Therefore, bastnaesite and fergusonite from the Chulmasan area were formed from redissolution/reconcentration of REE-and Th-bearing minerals from granitic gneiss and foliated mica granite at late stage by several igneous activies and metamorphism.

N- and P-doping of Transition Metal Dichalcogenide (TMD) using Artificially Designed DNA with Lanthanide and Metal Ions

  • Kang, Dong-Ho;Park, Jin-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.292-292
    • /
    • 2016
  • Transition metal dichalcogenides (TMDs) with a two-dimensional layered structure have been considered highly promising materials for next-generation flexible, wearable, stretchable and transparent devices due to their unique physical, electrical and optical properties. Recent studies on TMD devices have focused on developing a suitable doping technique because precise control of the threshold voltage ($V_{TH}$) and the number of tightly-bound trions are required to achieve high performance electronic and optoelectronic devices, respectively. In particular, it is critical to develop an ultra-low level doping technique for the proper design and optimization of TMD-based devices because high level doping (about $10^{12}cm^{-2}$) causes TMD to act as a near-metallic layer. However, it is difficult to apply an ion implantation technique to TMD materials due to crystal damage that occurs during the implantation process. Although safe doping techniques have recently been developed, most of the previous TMD doping techniques presented very high doping levels of ${\sim}10^{12}cm^{-2}$. Recently, low-level n- and p-doping of TMD materials was achieved using cesium carbonate ($Cs_2CO_3$), octadecyltrichlorosilane (OTS), and M-DNA, but further studies are needed to reduce the doping level down to an intrinsic level. Here, we propose a novel DNA-based doping method on $MoS_2$ and $WSe_2$ films, which enables ultra-low n- and p-doping control and allows for proper adjustments in device performance. This is achieved by selecting and/or combining different types of divalent metal and trivalent lanthanide (Ln) ions on DNA nanostructures. The available n-doping range (${\Delta}n$) on the $MoS_2$ by Ln-DNA (DNA functionalized by trivalent Ln ions) is between $6{\times}10^9cm^{-2}$ and $2.6{\times}10^{10}cm^{-2}$, which is even lower than that provided by pristine DNA (${\sim}6.4{\times}10^{10}cm^{-2}$). The p-doping change (${\Delta}p$) on $WSe_2$ by Ln-DNA is adjusted between $-1.0{\times}10^{10}cm^{-2}$ and $-2.4{\times}10^{10}cm^{-2}$. In the case of Co-DNA (DNA functionalized by both divalent metal and trivalent Ln ions) doping where $Eu^{3+}$ or $Gd^{3+}$ ions were incorporated, a light p-doping phenomenon is observed on $MoS_2$ and $WSe_2$ (respectively, negative ${\Delta}n$ below $-9{\times}10^9cm^{-2}$ and positive ${\Delta}p$ above $1.4{\times}10^{10}cm^{-2}$) because the added $Cu^{2+}$ ions probably reduce the strength of negative charges in Ln-DNA. However, a light n-doping phenomenon (positive ${\Delta}n$ above $10^{10}cm^{-2}$ and negative ${\Delta}p$ below $-1.1{\times}10^{10}cm^{-2}$) occurs in the TMD devices doped by Co-DNA with $Tb^{3+}$ or $Er^{3+}$ ions. A significant (factor of ~5) increase in field-effect mobility is also observed on the $MoS_2$ and $WSe_2$ devices, which are, respectively, doped by $Tb^{3+}$-based Co-DNA (n-doping) and $Gd^{3+}$-based Co-DNA (p-doping), due to the reduction of effective electron and hole barrier heights after the doping. In terms of optoelectronic device performance (photoresponsivity and detectivity), the $Tb^{3+}$ or $Er^{3+}$-Co-DNA (n-doping) and the $Eu^{3+}$ or $Gd^{3+}$-Co-DNA (p-doping) improve the $MoS_2$ and $WSe_2$ photodetectors, respectively.

  • PDF

Clinical Usefulness of Thyrotropin Binding Inhibitor Immunoglobulin (TBII) Assay by the Comparative Method (측정법에 따른 갑상선자극호르몬 결합억제면역글로블린(TBII)의 임상적 유용성 검토)

  • Park, Hee-Won;Shin, Hee-Jung;Kim, Tae-Hoon;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • Purpose: Detection of TSH-binding inhibitor immunoglobulin (TBII) in patients with hyperthyroidism is an important result of Graves' disease (GD) and hyperthyroidism treatment. This has been made out an inspection by commercial radio-receptor assays. To increase the sensitivity and the specificity of the assay, many results of the assay were reported. In this study we evaluated the clinical usetulness of TBII assays by the Comparative method. Material and Methods: We were measured by using healthy control group (n=30, male=20, female=10) of Seoul National University Hospital Healthcare System Gangnam Center from January to March in 2009. Similarly, We were measured by using hyperthyroid (TSH<$0.05\;{\mu}IU/mL$, FT4>1.80 ng/dL) experimental group (n=58, male=14, female=44) of division of endocrinology and metabolism department of internal medicine Seoul National University Hospital from January to March in 2009. We made a comparative study of each two assays from the first generation to the third generation. We were used of TSAb assay as a measurement of GD diagnostic technique. Results: The specificity of healthy control group was 100% according to the generation. (Specificity=100%, n=30) The sensitivity of hyperthyroid experimental group were the first generation RSR<%> (79.3%, n=58), RSR (51.7%, n=58), the second generation RSR-CT (93.1%, n=58), BRAHMSCT (98.3%, n=58), the third generation ELISA (94.6%, n=56), ECLIA (97.7%, n=58) and TS-Ab<%> (93.5%, n=46). Conclusion: We were used of TSAb assay as a measurement of GD diagnostic technique, The result of data showed a high correlation between the third generation TBII assay and the second generation TBII assay ($R^2$=0.923). Instead of the first generation assay, the second generation assay can be more useful in clincal diagnosis.

  • PDF

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF