Analysis of Benzophenone in Sediment and Soil by Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석기에 의한 저질 및 토양시료 중 벤조페논의 분석법 연구)

  • 권오승;김은영;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.3
    • /
    • pp.121-126
    • /
    • 2001
  • Analytical method of benzophenone (BP) in sediment and soil was developed by gas chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). The ultrasonic extraction of US EPA (method 3550B) method and liquid-liquid extraction for sediment and soil samples were used for the analysis of BP from sediment and soil. BP was extracted with n-hexane. Organic layer was washed with 5% sodium chloride solution. 1∼2 l of the concentrated solution of organic layer was applied to GC/MSD. The retention time of BP peak was 11.10 min. Recovery (%) of BP by ultrasonication from sediment and soil samples was 96.0∼100.6% and 40.0∼83.0%, respectively. Recovery of BP by liquid-liquid extraction was 51∼59% in soil samples. The detection limit of BP in sediment and soil samples were determined to 0.1 ng/g.

  • PDF

A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector (열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가)

  • 박정근;유기호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

A Rapid and Convenient Method for the Determination of Fatty Acid by Gas Chromatography-Flame Photometric Detector (가스크로마토그라피-염광광도검출기를 이용한 지방산의 신속간편한 정량)

  • 조영현;박만기;이숙연
    • YAKHAK HOEJI
    • /
    • v.29 no.5
    • /
    • pp.227-233
    • /
    • 1985
  • A new method of determination of fatty acid using gas chromatography-flame photometric detector (GC-FPD) is described. Fatty acid was methylthiomethyl-esterified with methylthiomethy chloride in 1,8-diazabicyclo [5,4,0]-undec-7-ene catalyst and its concentration measured by GC-FPD with 3%OV-1 or 3% FS-1 column. The FPD responses of thirteen fatty acid methylthiomethyl esters were examined and were proportional to the concentration of the esters without regard to their chemical structures. Consequently it was possible to determine various fatty acid using one standard calibration curve by GC-FPD. We could rapidly and conveniently determine varous fatty acids using one standard calibration curve by GC-FPD. We could rapidly and conveniently determine 13 fatty acids in Ginseng Radix alba by this method.

  • PDF

Multi-Pesticide Residue Method for Analysis of Organochlorine and Organophosphorus Pesticide

  • Bonghun Lee;Woo
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.37-39
    • /
    • 1997
  • Pesticide residues were extracted with 70% acetone and transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil and alumina-N, The final extract was analyzed by gas chromatography with electron-capture detector(GC/ECD) and nitrogen-phosphorus detector(GC/NPD). Recoveries of the 17 organochlorine pesticides were ranged from 60.8 to 84.9% and those of 15 organophosphorus pesticides, from 70.5 to 100.0%(except phosmet and azinphos-methyl). The minimum detectable levels of this analytical method were low (0.021-0.058 mg/kg).

  • PDF

폐기물 매립지 토양에서의 PCBs 분석법

  • Lee Jeong-Hwa;Jeon Chi-Wan;Jeong Yeong-Uk
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.199-201
    • /
    • 2005
  • This paper describes a simple procedure for the quantitative analysis of 7 PCBs (polychlorinated biphenyls) in soils on the waste reclaimed land, The procedure involved sample clean up using silicagel column, acetonitrile partition and sulfuric acid procedures. The instrumental technique is applied GC/PDD(gas chromatography/pulsed discharge detector) and GC/ECD(gas chromatography/electron capture detector). Concentration of $sub-{\mu}g/g$ level was attainable with 20g soils on the waste reclaimed land.

  • PDF

Evaluation of QuEChERS Method for Determination of pesticide Residues Using GC/NPD and GC/ECD (GC/NPD와 GC/ECD를 이용한 잔류농약 정량 분석법으로써의 QuEChERS의 평가)

  • Cho, Tae Hee;Park, Young Hye;Park, Hye Won;Hwang, Lae Hwong;Cho, In Soon;Kim, Min Jung;Kim, Hyun Jeong;Kim, Mu Sang;Chae, Young Zoo
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.1
    • /
    • pp.65-71
    • /
    • 2013
  • The modified QuEChERS method was evaluated for rapid determination of pesticide residues in spinach by gas chromatography-nitrogen phosphorous detector (NPD) and electron capture detector (ECD). Fifty GC-amenable pesticides which were most frequently detected in monitoring were selected in the current study. Matrix-matched calibration was performed. The detector response for all pesticides was linear with determination coefficients higher than 0.995. LODs for most compounds ranged between 0.001 and 0.1 ug/g, and about 90% of the compounds had LODs of less than 0.05 ug/g. LOQs ranged from 0.001 to 0.32 ug/g, which were well below the MRLs permitted for most of pesticides. In the majority of cases, the recoveries (80-120%) and relative standard deviations (RSDs) (less than 20%) were within acceptable levels except for dichlorvos, propamocarb, chlorothalonil, dichlofluanid, cyhalothrin and fenvalerate. Also, this method which is applied to routine samples showed good results when comparing with traditional multi-residue method.

Analysis of Volatile Organic Compounds in Kinnchi Absorbed in SPME by GC-AED and GC-MSD (SPME로 포집한 김치 휘발성분의 GC-AED및 GC-MSD에 의한 동정)

  • 하재호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.3
    • /
    • pp.543-545
    • /
    • 2002
  • The volatile compounds in kimchi adsorbed with solid phase microextraction (SPM) were analyzed by using a gas chromatograph-atomic emission detector (GC-AED) and a gas chromatograph-mass spectrometer (GC-MSD). The volatile compounds were effectively adsorbed in SPME. Twenty five compounds such as dimethyl-sulfide were identified by GC-MSD and some of these were further confirmed to contain a sulfur and a nitrogen by GC-AED.

Monitoring and risk assessment of pesticide in school foodservice products in seoul, Korea (서울지역 학교급식 식재료의 잔류농약 위해성 평가)

  • Seo, Young-Ho;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.21 no.1
    • /
    • pp.69-74
    • /
    • 2014
  • We tested for residual pesticide levels in school foodservice agricultural products in Seoul, Korea from 2010 to 2012. A total of 316 samples of 23 different types of agricultural products were analyzed via gas chromatography-nitrogen phosphate detector (GC-NPD), an electron capture detector (GC-${\mu}ECD$), a mass spectrometry detector (GC-MSD), and a high performance liquid chromatography-ultraviolet detector (HPLC-UV). We used multi-analysis methods to analyze 185 different pesticide types. Among the selected agricultural products, residual pesticides were detected in 26 samples (8.2%), of which 6 samples (1.9%) exceeded the Korea Maximum Residue limits (MRLs). We detected pesticide residue in more than 65% of the Chwinamul, while 6 among 9 analyzed samples contained pesticide residue, and 1 sample exceeded the Korea MRLs. Among the 185 kinds of pesticides that we have tested, 18 were detected, while 7 of them were detected more than twice. Data obtained were then used for estimating the potential health risks associated with the exposures to these pesticides. The most critical commodity is carbofuran in the perilla leaves, which has contributed 3.8% to the hazard index (HI). These results showed that the detected pesticides could not be considered as a serious public health problem. Nevertheless, constant supervision is recommended.

Comparison of Solid Phase Microextraction-Gas Chromatograph/Pulsed Flame Photometric Detector (SPME-GC/PFPD) and Static Headspace-Gas Chromatograph/Pulsed Flame Photometric Detector (SH-GC/PEPD) for the Analysis of Sulfur-Containing Compounds (Solid phase microextraction-gas chromatograph/pulsed flame photometric detector(SPME-GC/PFPD)와 static headspace-gas chromatograph/pulsed flame photometric detector(SH-GC/PEPD)를 이용한 황 함유 화합물들의 분석 방법 비교)

  • Yang, Ji-Yeon;Kim, Young-Suk
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.695-701
    • /
    • 2005
  • Efficient method was established for analysis of sulfur-containing compounds, including dimethyl disulfide, dimethyl trisulfide, 3-methyl thiophene, allyl mercaptan, 2-methyl-3-furanthiol, and methional. Sulfur-containing compounds were extracted through solid phase microextraction (SPME) or static headspace extraction (SH), and quantified using gas chromatograph equipped with pulsed flame photometric detector. All sulfur compounds, except ally mercaptan, showed higher detection response when dissolved in hexane than in dichloromethane. Linear range was $10^2-10^4$. Dimethyl trisulfide showed lowest limit of detection (LOD) value of 15.2 ppt, and methional highest of 70.5 ppb. Highest extraction efficiency for sulfur-containing compounds, particularly polar and small molecular weight compounds, was observed in 75mm carboxen/polydimethylsiloxane fiber, followed by 65mm polydimethylsiloxane/divinylbenzene and 100mm polydimethylsiloxane. Compared to SPME, less sulfur-containing compounds could be analyzed by SH, mainly due to its low extraction efficiency, although lower amount of artifacts were formed during sample preparation.