• Title/Summary/Keyword: G code

Search Result 856, Processing Time 0.028 seconds

Extending the Shelf-life of Yukwa Using Secondary Packaging (이차포장을 통한 유과의 저장성 연장)

  • Jung, Jun-Jae;Lee, Keun-Taik
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.452-458
    • /
    • 2010
  • This study aimed at improving the packaging technology of Yukwa to improve the quality and extend the shelflife using secondary packaging. After packaging the Yukwa using an OPP film, P2, P3, and P4 packaging materials were applied secondarily. Various films including (1) P1: OPP (oriented polypropylene), (2) P2: P1+OPP/LLDPE (linear low density polyethylene), (3) P3: P1+PET (polyethylene terephthalate)/NY (nylon)/CPP (cast polypropylene) and (4) P4: P1+PET/AL (aluminum)/NY/CPP (P4) were used for packaging Yukwa. The experiment was conducted at $25^{\circ}C$ for 12 weeks. P1 showed the highest acid value score (1.26 mg KOH/g), and P3 had the highest peroxide value score (32.91 meq/kg) among all packaging groups. Nevertheless, these values did not exceed the guideline values of 2.0 g KOH/g and 40 meq/kg specified in the Korean food code. The overall color difference showed a tendency for decreasing Hunter 'L' values and increasing 'a' and 'b' values; however, no noticeable difference in the outer appearance was observed in any of the packaging treatments except in the P1 for greater than 10 weeks of storage. Some texture defects were observed in the Yukwa when the moisture contents dropped below 5%. The P4 packaging treatment had the lowest moisture permeability and showed the least rheological deterioration change, followed by P3 and P2. In conclusion, the use of a secondary packaging with less gas and moisture permeability was more effective for maintaining the quality and extending the shelf-life of Yukwa than other types of packaging material.

Making Aids of Magnetic Resonacnce Image Susing 3D Printing Technology (3D 프린트를 활용한 자기공명영상검사 보조기구 제작)

  • Choi, Woo jeon;Ye, Soo young;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.403-409
    • /
    • 2016
  • MRI scan is a useful method in the diagnosis of musculoskeletal excellent contrast of the organization. Depending on the patient's musculoskeletal examinations state the type of aids provided the aid is used there is also challenging as well as the costs do not vary. This study was produced by the use of 3D printing technology, an MRI aids. Aids in the production process, then through 3D modeling and then convert stl files using (3D MAX.2014, Fusion360) slicing programs (Cubicreater 2.1ver., Cura 15.4ver) converted to G-code printed on the FDM scheme (Cubicon Style, output was MICRO MAKE). Output is, but in the FDM to evaluate the SNR on the MRI images were compared to the test is the case before use, and then to produce a Water Phantom case of a PLA, ABS, a TPU thickness 3mm, using aids before, It was evaluated in a clinical image after qualitatively. Obtaining an image of SNR Warter Phantom appeared to have been evaluated as T1 NON $123.778{\pm}28.492$, PLA $123.522{\pm}28.373$, ABS $124.461{\pm}25.716$, TPU $124.843{\pm}27.272$. T2 NON $127.421{\pm}26.949$, was rated as PLA $124.501{\pm}27.768$, ABS $128.663{\pm}26.549$, TPU $130.171{\pm}25.998$. The results did not show statistically significant differences. The use of assistive devices before and after images Clinical evaluation method palliative $3.20{\pm}0.88$, $3.95{\pm}0.76$ after using the aids used to aid improved the quality of the image. Production of the auxiliary mechanism using a future 3D printing is expected are thought to be used clinically, it can be an aid making safe and comfortable than the inspection of the patient is an alternative to improve the problems of the aids used in the conventional do.

Radiological Dose Analysis to the Public Resulting from the Operation of Daedeok Nuclear Facilities (대덕부지 원자력관련시설 운영에 따른 주민피폭선량 현황분석)

  • Jeong, Hae Sun;Kim, Eun Han;Jeong, Hyo Joon;Han, Moon Hee;Park, Mi Sun;Hwang, Won Tae
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.38-45
    • /
    • 2014
  • This paper describes the results of assessment of radiological dose resulting from operation of the Daedeok nuclear facilities including the HANARO research reactor, which has been performed to assure whether or not to comply with the regulation standards of the radioactive effluents releases. Based on the meteorological data and the radiation source term, the maximum individual doses were evaluated from 2010 to 2012. The atmospheric dispersion and the deposition factors of gaseous effluents were calculated using the XOQDOQ computer code. ENDOS-G and ENDOS-L code systems were also used for maximum individual dose calculation from gaseous and liquid effluents, respectively. The results were compared with the regulation standards for the radioactive effluents presented by the Nuclear Safety and Security Commission (NSSC). The effective doses and the thyroid doses of the maximum individual were calculated at the maximum exposed point in the Daedeok site, and contributions of exposure pathways to the radiological doses resulting from gaseous and liquid radioactive effluents were evaluated at each facility of the Daedeok site. As a result, the maximum exposed age was analysed to be the child group, and the operation of HANARO research reactor had a major effect more than 90% on the individual doses. The main exposure pathways for gaseous radioactive effluent were from ingestion and inhalation. The effective doses and the thyroid doses were considerably influenced by tritium and iodine, respectively. The gaseous radioactive effluents contributed more than 90% on the total doses, whereas the contributions of the liquid radioactive effluents were relatively low. Consequently, the maximum individual dose due to radioactive effluents from the nuclear facilities within the Daedeok site were less than 3% of the regulation standard over 3 years; therefore, it can be concluded that radioactive effluents from the nuclear facilities were well managed, with the radiation-induced health detriment for residents around the site being negligible.

A Study on the Medium Designator In Non-book Materials (비도서자료의 매체표시에 관한 연구)

  • Nam Tae Woo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.15
    • /
    • pp.119-140
    • /
    • 1988
  • This paper is the study on the Medium Designator in Non-book materials. Main contents of this study were as follows; 1. The medium designator serves to indicate the class of material to which an item belongs. This is used to give an 'early warning' ;to the catalogue user. 2. This medium designator may be further divided into two elements ; a general material designation (GMD), for example video-recording, and a specific material designation (SMD), for example, videodisc. 3. GMD: In cataloging, a term indicating the broad class of material to which a bibliographic item belongs, such as 'motion picture', and SMD : In descriptive cataloging, a term indicating the special class of material (usually the class of physical object) to which a biblographic item belongs, such as videocassette. 4. Locating the medium designator after the title proper was not prescribed until ISBD(G) and AACR2. In pre-ISBD(G) codes, the ,early, warning type of medium designator was placed after all title information. But in AACR2, the medium designator is placed after the title proper, but before parellel title and other title information. 5. In Terminology, Two separate lists of designations are given in AACR2, l.1C1, one for British and one for North American use. The British list contains fewer terms, and uses generic categories to group together some of the North American list. 6. The problem of where to place the medium designator might be circumvented by using some kind of early alerting device other than a formal element of biblliographic description. Various alternatives have been suggested. A more popular device is the provision of symbols or 'media code' which are part of the call number and indicate the porticular medium type. 'Colour-coding' the use of used by some libraries but is now longly discouraged. 7. According to Frost. The medium designatorhas been generally reeognized as serving three functions; 1) as a statement of the nature or basic format of the item cataloged and thus as a meant of informing the user as to the type of material at hand; 2) as a description of the physical charaetistics of medium and as a means of alerting the user to equipment needed to make use of the item. 3) as a device to distinguish different physical formats which share the same title. 8. AACR2 raises some problems which decision makers have neet had to face preriously It provides a GMD for every item in the collection including books and it makes the application of any or all GMD's optional.

  • PDF

Establishment of Hanwoo(Korean Cattle, Bos taurus, Linn.) Traceability System Using Radio Frequency Identification(RF-ID) (전자식별칩(RF-ID)을 이용한 한우 생산이력추적시스템 도입)

  • Seo, K. S.;Kim, S.;Lee, J.G.;Sohn, Y.G.;Salces, A.J.;Choi, T.J.
    • Journal of Animal Science and Technology
    • /
    • v.50 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study was conducted to develop a traceability system for systematic animal identifi- cation to increase efficiency of animal production, post production and processing to ensure that quality and sanitary meat products reach the consumers of the entire country. The new animal identification traceability system was designed for easy management, data collection and storage considering bar code, registration number and farm number.Specifically the system aimed 1) To provide standard radio frequency technology identification (RF-ID) for livestock management, standard of ear tag, microchip and ear tag identification equipment, 2) To guarantee meat product label thereby safeguarding the consumers 3) To give incentives to farmers for producing quality meat products and 4) To provide unified system for national livestock management.Results of the research which started in July 2003 which was used by several farmers’ cooperatives and Department Store revealed the feasibility of using the RF-ID system although much will be done to conform to global nomenclatures.

Reduction Factor for the Site Coefficient of a Building built on a Poor-backfilled Embedded Foundation (뒷채움이 부실한 묻힌기초 위에 세워진 건축물의 지반증폭계수에 대한 저감계수)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • In this paper, the reduction factors to calculate the site coefficients of an embedded foundation are estimated, considering the effect of a poor backfill for the seismic design of a building built on an embedded foundation. This is determined by utilizing in-house finite element software, P3DASS, which has the capability of horizontal pseudo 3D seismic analysis with nonlinear soil. The 30m thick soil on stiff rock was assumed to be homogeneous, elastic, viscous and isotropic, and equivalent circular rigid foundations with radii of 10-70m were assumed to be embedded 0, 10, 20, and 30 m in the soil. Seismic analyses were performed with 7 bedrock earthquake records de-convoluted from the outcrop records; the scaling of the peak ground accelerations were to 0.1 g. The study results show that the site coefficients of a poor-backfilled foundation are gradually reduced as the foundation embedment ratio increases, except in the case of a small foundation embedded deeply in the weak soft soil. In addition, it was found that the deviation of the site coefficients due to the foundation size was not significant. Therefore, the typical reduction factors of an embedded foundation with poor backfill are proposed in terms of the shear wave velocity and site class. This is in order to find the site coefficients of an embedded foundation by multiplying the reduction factor by a site coefficient of a surface foundation specified in the design code. They can then be interpolated to determine the intermediate shear wave velocity.

Seismic and Stress Analysis of 72.5kV GIS for Technical Specification of KEPCO (72.5kV GIS 전력 장비의 KEPCO 기준 내진 및 응력 해석)

  • Lee, Jae-Hwan;Kim, Young-Joong;Kim, So-Ul;Bang, Myung-Suk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.207-214
    • /
    • 2017
  • High voltage electric power transmitter GIS(Gas Insulated Switchgear) above 72.5kV needs to satisfy domestic Korean peninsular standard(ES-6110-0002) in KEPCO with respect to normal and special operation conditions which include internal gas pressure, dead weight, wind and seismic load. Some other requirements not described in Korean standard can be applied from other international standards such as IEC(International Electronical Committee) 62271-203 and 62271-207. The GIS is a kind of pressure vessel structure made of aluminum and filled with SF6 gas of internal pressure 0.4~0.5MPa. Finite element analysis of GIS is performed with such operational loads including seismic loading and the stability and reliability is determined according to ASME BPVC(Boiler and Pressure Vessel Code) SEC. VIII standard where the allowable stress level of the pressure vessel is suggested. The result shows that the stress of GIS is satisfied the allowable stress level and the safety factor is about 2.3 for Korean peninsular standard.

Reduction Factor of the Site Coefficient due to the Foundation Embedment in the Soft Soil Layer for the Seismic Analysis of a Building (건축물의 지진해석을 위한 연약지반에 묻힌 기초로 인한 지반증폭계수에 대한 저감계수)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.1-15
    • /
    • 2010
  • In this study, the reduction factor of the code-defined site coefficient due to the embedment of a foundation was estimated for the seismic analysis of a building built on a soft soil site. This was done by utilizing the in-house finite element software P3DASS, which has the capability of pseudo 3D seismic analysis with nonlinear soil layers. A 30m thick soft soil site laid on the rock was assumed to be homogeneous, elastic, viscous and isotropic, and equivalent circular rigid foundations with radii of 10-70m were considered to be embedded at 0, 10, 20 and 30m in the soil layer. Seismic analyses were performed with 7 bedrock earthquake records deconvoluted from the outcrop records of which the effective ground acceleration was scaled to 0.1g. The study results showed that the site coefficients are gradually reduced except in the case of a small foundation embedded deeply in the weak soil layer, and it was estimated that the deviation of the site coefficients due to the foundation size was not significant. The standard reduction factor due to the foundation embedment were calculated adding the standard deviation to the average of 5 reduction factors calculated for 5 different foundation radii. Standard reduction factors for the site amplification factor were proposed for the practical amplification and the codes of KBC, etc., in accordance with the average shear wave velocity of the site, and the site class.

Analysis of Bacterial Community Structure in the Soil and Root System by 168 rRNA Genes (16S rDNA를 이용한 토양, 작물근계의 세균군집 구조해석)

  • Kim, Jong-Shik;Kwon, Soon-Wo;Ryu, Jin-Chang;Yahng, Chang-Sool
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.4
    • /
    • pp.266-274
    • /
    • 2000
  • Understanding of microbial community structure in soil-root system is necessary to use beneficial soil and rhizosphere microbes for improvement of crop production and biocontrol. The knowledge of behavior and function of microbes in soil-root system plays a key role for the application of beneficial inocula. Because the majority of the intact bacteria in soil are unable to grow on nutrient media, both culturable and nonculturable bacteria have to be studied together. In our study, culture-independent survey of bacterial community in the soil-root system of red pepper fields was conducted by the sequence analysis of three universal clone libraries of genes which code for small-subunit rRNA (rDNA). Universal small subunit rRNA primers were used to amplify DNA extracted from each sample and PCR products were cloned into pGEM-T. Out of 27 clones sequenced, 25 clones were from domain bacteria. Two of the rDNA sequences were derived from eukaryotic organelles. Within the domain bacteria, several kingdoms were represented : the Proteobacteria (16 clones). Cytophyga-Flexibacter-Bacteroides group (2 clones). the high G+C content gram-positive group(1 clone) and 4 unknown clones.

  • PDF

Organ Dose Conversion Coefficients Calculated for Korean Pediatric and Adult Voxel Phantoms Exposed to External Photon Fields

  • Lee, Choonsik;Yeom, Yeon Soo;Griffin, Keith;Lee, Choonik;Lee, Ae-Kyoung;Choi, Hyung-do
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.69-75
    • /
    • 2020
  • Background: Dose conversion coefficients (DCCs) have been commonly used to estimate radiation-dose absorption by human organs based on physical measurements of fluence or kerma. The International Commission on Radiological Protection (ICRP) has reported a library of DCCs, but few studies have been conducted on their applicability to non-Caucasian populations. In the present study, we collected a total of 8 Korean pediatric and adult voxel phantoms to calculate the organ DCCs for idealized external photon-irradiation geometries. Materials and Methods: We adopted one pediatric female phantom (ETRI Child), two adult female phantoms (KORWOMAN and HDRK Female), and five adult male phantoms (KORMAN, ETRI Man, KTMAN1, KTMAN2, and HDRK Man). A general-purpose Monte Carlo radiation transport code, MCNPX2.7 (Monte Carlo N-Particle Transport extended version 2.7), was employed to calculate the DCCs for 13 major radiosensitive organs in six irradiation geometries (anteroposterior, posteroanterior, right lateral, left lateral, rotational, and isotropic) and 33 photon energy bins (0.01-20 MeV). Results and Discussion: The DCCs for major radiosensitive organs (e.g., lungs and colon) in anteroposterior geometry agreed reasonably well across the 8 Korean phantoms, whereas those for deep-seated organs (e.g., gonads) varied significantly. The DCCs of the child phantom were greater than those of the adult phantoms. A comparison with the ICRP Publication 116 data showed reasonable agreements with the Korean phantom-based data. The variations in organ DCCs were well explained using the distribution of organ depths from the phantom surface. Conclusion: A library of dose conversion coefficients for major radiosensitive organs in a series of pediatric and adult Korean voxel phantoms was established and compared with the reference data from the ICRP. This comparison showed that our Korean phantom-based data agrees reasonably with the ICRP reference data.