• 제목/요약/키워드: G/K-system

검색결과 8,652건 처리시간 0.038초

장애물 추정 및 클러스터링을 위한 장애물 데이터베이스 관리 모듈 개발: G-eye 관리 시스템 (Development of Obstacle Database Management Module for Obstacle Estimation and Clustering: G-eye Management System)

  • 민성희;오유수
    • 한국멀티미디어학회논문지
    • /
    • 제20권2호
    • /
    • pp.344-351
    • /
    • 2017
  • In this paper, we propose the obstacle database management module for obstacle estimation and clustering. The proposed G-eye manager system can create customized walking route for blind people using the UI manager and verify the coordinates of the path. Especially, G-eye management system designed a regional information module. The regional information module can improve the loading speed of the obstacle data by classifying the local information by clustering the coordinates of the obstacle. In this paper, we evaluate the reliability of the walking route generated from the obstacle map. We obtain the coordinate value of the path avoiding the virtual obstacle from the proposed system and analyze the error rate of the path avoiding the obstacle according to the size of the obstacle. And we analyze the correlation between obstacle size and route by classifying virtual obstacles into sizes.

퍼지제어기를 이용한 태양광발전 시스템의 출력특성 (Output Characteristics of PV System Using Fuzzy Controller)

  • 임홍우;김성결;최연옥;서진연;오금곤;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.140-143
    • /
    • 2003
  • In order to improve the system utility efficiency of energy conversion, it is desirable to operate the PV system at maximum power point of solar cell under versable condition. This paper describes the experimental results of the PV system that contains a solar modules and DC-DC converter(boost type chopper). The Simulation results show that the PV system always operate at maximum power point of solar cells having stabilize output voltage waveform with relatively small ripple component.

  • PDF

기상청 전지구 수치예보모델을 이용한 전지구 한국형 항공난류 예측시스템(G-KTG) 개발 (Development of the Global-Korean Aviation Turbulence Guidance (Global-KTG) System Using the Global Data Assimilation and Prediction System (GDAPS) of the Korea Meteorological Administration (KMA))

  • 이단비;전혜영
    • 대기
    • /
    • 제28권2호
    • /
    • pp.223-232
    • /
    • 2018
  • The Global-Korean aviation Turbulence Guidance (G-KTG) system is developed using the operational Global Data Assimilation and Prediction System of Korea Meteorological Administration with 17-km horizontal grid spacing. The G-KTG system provides an integrated solution of various clear-air turbulence (CAT) diagnostics and mountain-wave induced turbulence (MWT) diagnostics for low [below 10 kft (3.05 km)], middle [10 kft (3.05 km) - 20 kft (6.10 km)], and upper [20 kft (6.10 km) - 50 kft (15.24 km)] levels. Individual CAT and MWT diagnostics in the G-KTG are converted to a 1/3 power of energy dissipation rate (EDR). 12-h forecast of the G-KTG is evaluated using 6-month period (2016.06~2016.11) of in-situ EDR observation data. The forecast skill is calculated by area under curve (AUC) where the curve is drawn by pairs of probabilities of detection of "yes" for moderate-or-greater-level turbulence events and "no" for null-level turbulence events. The AUCs of G-KTG for the upper, middle, and lower levels are 0.79, 0.69, and 0.63, respectively. Comparison of the upper-level G-KTG with the regional-KTG in East Asia reveals that the forecast skill of the G-KTG (AUC = 0.77) is similar to that of the regional-KTG (AUC = 0.79) using the Regional Data Assimilation and Prediction System with 12-km horizontal grid spacing.

The Communication Method at the Auto-Startup System using TCP/IP and VXI and Expert System(G2)

  • Kim, Jung-Soo;Joon Lyon
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제1권2호
    • /
    • pp.141-146
    • /
    • 1999
  • This paper describes the communication method of an auto-startup system. The Auto-Startup system is designed to operate a nuclear power plant automatically during the startup operation . In general , the operations during startup in existing plant have only been manually controlled by the operator. The manual operation caused to the operator mistake. The Auto-Startup system consists of the Distributed Control System(DCS) and G2 (Expert System). Also, Functional Test Facility(FTF) provides the plant's real-data for an Auto-Startup system. So, it is necessary to develop the communication method between these systems. We developed two methods ; one is a network and the other is a hardwire line. To communicate between these systems (DCS-G2 and DCS-FTF) , we developed the communication program. In case of DCS-FTF, we used the TCP/IP and VXI. BUt, in case of DCS-G2 , we , what it called , developed the bridge program using the GSI(G2 Standard Interface). We test to check the function of the important parameter, in time, for analysis of the developed communication method. The results are a good performance when we check the communication time of important parameter. We conclude that Auto-startup system could save heat-up time about at least 5 hours and reduced the change of the reactor operation and trip.

  • PDF

BINDING NUMBER AND HAMILTONIAN (g, f)-FACTORS IN GRAPHS

  • Cai, Jiansheng;Liu, Guizhen
    • Journal of applied mathematics & informatics
    • /
    • 제25권1_2호
    • /
    • pp.383-388
    • /
    • 2007
  • A (g, f)-factor F of a graph G is Called a Hamiltonian (g, f)-factor if F contains a Hamiltonian cycle. The binding number of G is defined by $bind(G)\;=\;{min}\;\{\;{\frac{{\mid}N_GX{\mid}}{{\mid}X{\mid}}}\;{\mid}\;{\emptyset}\;{\neq}\;X\;{\subset}\;V(G)},\;{N_G(X)\;{\neq}\;V(G)}\;\}$. Let G be a connected graph, and let a and b be integers such that $4\;{\leq}\;a\;<\;b$. Let g, f be positive integer-valued functions defined on V(G) such that $a\;{\leq}\;g(x)\;<\;f(x)\;{\leq}\;b$ for every $x\;{\in}\;V(G)$. In this paper, it is proved that if $bind(G)\;{\geq}\;{\frac{(a+b-5)(n-1)}{(a-2)n-3(a+b-5)},}\;{\nu}(G)\;{\geq}\;{\frac{(a+b-5)^2}{a-2}}$ and for any nonempty independent subset X of V(G), ${\mid}\;N_{G}(X)\;{\mid}\;{\geq}\;{\frac{(b-3)n+(2a+2b-9){\mid}X{\mid}}{a+b-5}}$, then G has a Hamiltonian (g, f)-factor.

Influence of the Central Benzodiazepinergic System on Peripheral Cardiovascular Regulation

  • Koh, Jeong-Tae;Ju, Jeong-Min;Shin, Dong-Ho;Cho, Han-Ho;Choi, Bong-Kyu;Kim, Jae-Ha
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제2권3호
    • /
    • pp.287-295
    • /
    • 1998
  • Diazepam is known to have cardiovascular depressive effects through a combined action on benzodiazepinergic receptor and the GABA receptor-chloride ion channel complex. Moreover, it is known that barbiturates also have some cardiovascular regulatory effects mediated by the central GABAergic system. Therefore, this study was undertaken to delineate the regulatory actions and interactions of these systems by measuring the responses of the cardiovascular system and renal nerve activity to muscimol, diazepam and pentobarbital, administered intracerebroventricularly in rabbits. When muscimol $(0.03{\sim}0.3\;{\mu}\;g/kg)$, diazepam $(10{\sim}100\;{\mu}\;g/kg)$ and pentobarbital $(1{\sim}10\;{\mu}\;g/kg)$ were injected into the lateral ventricle of the rabbit brain, there were similar dose-dependent decreases in blood pressure (BP) and renal nerve activity (RNA). The relative potency of the three drugs in decreasing BP and RNA was muscimol > pentobarbital > diazepam. Muscimol and pentobarbital also decreased the heart rate in a dose-dependent manner; however, diazepam produced a trivial, dose-independent decrease in heart rate. Diazepam $(30\;{\mu}g/kg)$ augmented the effect of muscimol $(0.1\;{\mu}g/kg)$ in decreasing blood pressure and renal nerve activity, but pentobarbital $(3\;{\mu}g/kg)$ did not. Bicuculline $(0.5\;{\mu}g/kg)$, a GABAergic receptor blocker, significantly attenuated the effect of muscimol in decreasing BP and RNA, either alone or with diazepam, and that of pentobarbital in decreasing BP and RNA, either alone or with muscimol. We inferred that the central benzodiazepinergic and barbiturate systems help regulate peripheral cardiovascular function by modulating the GABAergic system, which adjusts the output of the vasomotor center and hence controls peripheral sympathetic tone. Benzodiazepines more readily modulate the GABAergic system than barbiturates.

  • PDF

조선대학교 기숙사 전원용 PV 시스템의 운전특성 (Operating Characteristics of Photovoltaics System for Chosen University Dormitory)

  • 박정민;최연옥;이강연;오금곤;조금배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.564-566
    • /
    • 2006
  • This paper presents experimental operation with utility interactive 50kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for dormitory.

  • PDF

AWS기반 3G 통합환경센서 모듈을 이용한 실시간 환경 모니터링 시스템 개발 (Development of Real-time Environment Monitoring System Using 3G Integrated Environmental Sensors Based on AWS)

  • 천승만;이승준;윤장규;석수영
    • 대한임베디드공학회논문지
    • /
    • 제13권2호
    • /
    • pp.101-107
    • /
    • 2018
  • As indoor pollutants such as carbon dioxide and dust mainly affect the respiratory and circulatory systems, there is an increasing need for real-time indoor / outdoor environmental monitoring. In this paper, we have developed a real - time environmental monitoring system using the cloud-based 3G integrated environmental sensor module for environmental monitoring. A highly reliable environmental information monitoring system requires various IT technologies such as infrastructure (server, commercial software, etc.), service application software, security, and authentication. A real-time environment monitoring system based on cloud service that can provide reliable service satisfying these configuration requirements is proposed and implemented. It is expected that this system can be applied to various technologies such as indoor automatic window opening/closing system based on the Internet.

Utilization of biofilter/photo-catalytic reactor system for the simultaneous treatment of hydrogen sulfide and toluene from waste-air

  • Lim, Kwang-Hee;Ping, Wang Zhi;Lim, Dong-Joon;Lee, Eun-Ju
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.287-292
    • /
    • 2005
  • Hybrid시스템의 운전결과 황화수소의 removal efficiency는 황화수소의 inlet load가 $200g/m^{3}/h$에서 removal efficiency가 급격히 감소하여 약 60%의 수준을 유지하였다. 또한 톨루엔에 대한 removal efficiency는 거의 100%를 유지하다가 톨루엔의 inlet load가 $644g/m^{3}/h$로 증가할 때에는 약 60%로 감소하였다. 이와 같은 Hybrid시스템 운전결과로 부터 바이오필터만을 이용하여 황화수소와 톨루엔을 동시처리할 때보다 removal efficiency가 제고되었음이 관찰되었다.

  • PDF

A Performance Analysis Model of PC-based Software Router Supporting IPv6-IPv4 Translation for Residential Gateway

  • Seo, Ssang-Hee;Kong, In-Yeup
    • Journal of Information Processing Systems
    • /
    • 제1권1호
    • /
    • pp.62-69
    • /
    • 2005
  • This paper presents a queuing analysis model of a PC-based software router supporting IPv6-IPv4 translation for residential gateway. The proposed models are M/G/1/K or MMPP-2/G/1/K by arrival process of the software PC router. M/G/1/K is a model of normal traffic and MMPP-2/G/1/K is a model of burst traffic. In M/G/1/K, the arriving process is assumed to be a Poisson process, which is independent and identically distributed. In MMPP-2/G/1/K, the arriving process is assumed to be two-state Markov Modulated Poisson Process (MMPP) which is changed from one state to another state with intensity. The service time distribution is general distribution and the service discipline of the server is processor sharing. Also, the total number of packets that can be processed at one time is limited to K. We obtain performance metrics of PC-based software router for residential gateway such as system sojourn time blocking probability and throughput based on the proposed model. Compared to other models, our model is simpler and it is easier to estimate model parameters. Validation results show that the model estimates the performance of the target system.