• 제목/요약/키워드: Fuzzy factor

검색결과 432건 처리시간 0.023초

직교배열표를 이용한 다목적 퍼지제어 알고리즘 및 능동자기베어링 시스템에의 응용 (Fuzzy Control Algorithm for Multi-Objective Problems using Orthogonal Array and its Application to an AMB System)

  • 김추호;이종원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.449-454
    • /
    • 2000
  • A new fuzzy logic control design algorithm suitable for multi-objective control problems is proposed based on the orthogonal array which is widely used for design of experiments in statistics and industrial engineering. The essence of the algorithm is to introduce Nth-certainty factor defined from the F-value of the ANOVA(analysis of variance) table, in order to effectively exclude the less confident rules. The proposed algorithm with multi-objective decision table(MODT) is found to be capable of the detection of inconsistency and the rule classification, reduction and modification. It is also shown that the algorithm can be successfully applied to the fuzzy controller design of an active magnetic bearing system.

  • PDF

절삭가공에서 퍼지알고리즘을 이용한 칩형상 예측 (Chip Form Prediction using Fuzzy Logic in Turning)

  • 최원식
    • 한국산업융합학회 논문집
    • /
    • 제4권2호
    • /
    • pp.127-132
    • /
    • 2001
  • In turning, the chip may be produced in the form of continuous chip or discontinuous chip. The continuous chips are dangerous to the operator and difficult to be handled at high speed machining. The signal of AE(Acoustic Emission) is found out to be related to cutting conditions, tool materials, test conditions and tool geometry in turning. In this study, the relationship between AE signal and chip form was experimentally investigated. The experimental results show that the types of chip form are possible to be classified from the AE signal using fuzzy logic.

  • PDF

불확실한 비선형시스템을 위한 고장검출 시스템 설계 (A Fault Detection system Design for Uncertain Nonlinear Systems)

  • 류석환;최병재
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2006년도 추계학술대회 학술발표 논문집 제16권 제2호
    • /
    • pp.356-361
    • /
    • 2006
  • 본 연구에서는 T-S 퍼지시스템으로 모델된 불확실한 시변 파라메터를 갖는 비선형 시스템의 고장검출 시스템 설계법을 제안한다. 이를 위하여 퍼지시스템에 대한 소인수 분해를 정의하고 좌 소인수를 이용하여 오차발생기를 설계한다. 오차 발생기의 출력으로부터 고장검출을 판정하는 검출기준을 제시한다. 제시된 방법의 효용성을 입증하기 위하여 역도립 진자시스템에 적용하여 컴퓨터 모의실험을 수행한다.

  • PDF

A Fuzzy Logic Based Software Development Cost Estimation Model with improved Accuracy

  • Shrabani Mallick;Dharmender Singh Kushwaha
    • International Journal of Computer Science & Network Security
    • /
    • 제24권6호
    • /
    • pp.17-22
    • /
    • 2024
  • Software cost and schedule estimation is usually based on the estimated size of the software. Advanced estimation techniques also make use of the diverse factors viz, nature of the project, staff skills available, time constraints, performance constraints, technology required and so on. Usually, estimation is based on an estimation model prepared with the help of experienced project managers. Estimation of software cost is predominantly a crucial activity as it incurs huge economic and strategic investment. However accurate estimation still remains a challenge as the algorithmic models used for Software Project planning and Estimation doesn't address the true dynamic nature of Software Development. This paper presents an efficient approach using the contemporary Constructive Cost Model (COCOMO) augmented with the desirable feature of fuzzy logic to address the uncertainty and flexibility associated with the cost drivers (Effort Multiplier Factor). The approach has been validated and interpreted by project experts and shows convincing results as compared to simple algorithmic models.

ELM 기반의 지능형 알고리즘과 퍼지 소속함수를 이용한 유입변압기 고장진단 기법 (Diagnosis Method for Power Transformer using Intelligent Algorithm based on ELM and Fuzzy Membership Function)

  • 임재윤;이대종;지평식
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.194-199
    • /
    • 2017
  • Power transformers are an important factor for power transmission and cause fatal losses if faults occur. Various diagnostic methods have been applied to predict the failure and to identify the cause of the failure. Typical diagnostic methods include the IEC diagnostic method, the Duval diagnostic method, the Rogers diagnostic method, and the Doernenburg diagnostic method using the ratio of the main gas. However, each diagnostic method has a disadvantage in that it can't diagnose the state of the power transformer unless the gas ratio is within the defined range. In order to solve these problems, we propose a diagnosis method using ELM based intelligent algorithm and fuzzy membership function. The final diagnosis is performed by multiplying the result of diagnosis in the four diagnostic methods (IEC, Duval, Rogers, and Doernenburg) by the fuzzy membership values. To show its effectiveness, the proposed fault diagnostic system has been intensively tested with the dissolved gases acquired from various power transformers.

한국어 퍼지 언어변수를 이용한 리스크 평가의 논리적 일관성 (Logical Consistency in Risk Assessment using the Korean Fuzzy Linguistic Variables)

  • 임현교;변상훈
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.120-125
    • /
    • 2016
  • Usually, a risk can be expressed as a product of likelihood and consequence of a hazard factor. Therefore, conventional risk assessment is carried out by frequency analysis and severity analysis, in turns. However, it is well known that intuitive thinking is another excellent way of thinking of human beings. This study aimed to confirm whether there exist any difference in risk assessment results derived by two different procedures - intuitive and analytical. Thus, the present study showed 10 different illustrations to 30 undergraduate students. Their responses were organized as fuzzy membership functions, and summarized as risk assessments, and compared. The results were also verified with the help of statistical hypothesis testing, which showed no significant difference. On the contrary, however, similarity measure used in fuzzy set theory was not credible as anticipated. Many cases failed to satisfy statistical hypothesis even with similarity measure higher than 0.60 so that only a trend could be accepted. In addition, a subject showed a somewhat consistent logical discrepancy in his response, which implied the necessity of sincere analysis in fuzzy formulations.

퍼지근사추론에 의한 폐터널의 보강방식 선정 (Determination of Reinforcement Method for Abandoned Tunnel by Fuzzy Approximate Reasoning)

  • 조만섭
    • 터널과지하공간
    • /
    • 제14권4호
    • /
    • pp.275-286
    • /
    • 2004
  • 본 논문에서는 신규 터널노선과 교차하는 폐터널의 보강방식을 결정하기 위하여 의사결정기법을 검토하였고, 여러 가지 의사결정기법들 중에서 설문조사의 과정을 최소화 하고, 조사항목 별 정성적ㆍ정량적 특성을 모두 반영할 수 있도록 쌍대비교와 퍼지근사추론을 이용하여 폐터널의 보강방식에 대한 적정성을 평가하여 보았다. 페터널 보강방식을 선정하기 위하여 4개의 주 요인들 즉, 시공성, 경제성, 안전성, 유지관리성을 평가의 수단으로 사용하였고, 간단한 설문조사와 쌍대비교행렬을 이용하여 4가지 주 요인들의 가중치를 결정하였다. 퍼지근사추론은 4개의 주 요인별 평가점수를 산정 하는데 사용되어졌고, 이 결과들에 가중치를 반영하여 최종적인 폐터널의 보강방식을 선정할 수 있었다.

Modeling, Control, and Optimization of Activated Sludge Processes

  • Bae, Hye-on;Kim, Bong-chul;Kim, Sung-shin;Kim, Chang-won;Kim, Sang-hyun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제1권1호
    • /
    • pp.56-61
    • /
    • 2001
  • Activated sludge processes are broadly used in the biological wastewater treatment processes. The activated sludge processes are complex systems because of the many factors such as the variation of influent flowrate and ingredients, the complexity of biological reactions, and the various operation conditions. The main motivation o this research is to develop an intelligent control strategy for activated sludge process (ASP). ASP is a complex and nonlinear dynamic system owing to the characteristic of wastewater, the change in influent flowrate, weather conditions, and so on. The mathematical model of ASP also includes the uncertainty which is a ignored or unconsidered factor from process designers. The ASP model based on Matlabⓡ/Simulinkⓡ is developed in this paper. And the model performance is examined by IWA (International Water Association) and COST (European Cooperation in the filed of Scientific and Technical Research) data. The model tests derive steady-state results of 14 days. In this paper, fuzzy logic control approach is applied to handle DO concentrations. The fuzzy logic controller includes two inputs and one output to adjust air flowrate. The objective function for the optimization, in the implemented evolutionary strategy, is formed with focusing on improving the effluent quality and reducing the operating cost.

  • PDF

Systematic Elicitation of Proximity for Context Management

  • Kim Chang-Suk;Lee Sang-Yong;Son Dong-Cheul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제6권2호
    • /
    • pp.167-172
    • /
    • 2006
  • As ubiquitous devices are fast spreading, the communication problem between humans and these devices is on the rise. The use of context is important in interactive application such as handhold and ubiquitous computing. Context is not crisp data, so it is necessary to introduce the fuzzy concept. The proxity relation is represented by the degree of closeness or similarity between data objects of a scalar domain. A context manager of context-awareness system evaluates imprecise queries with the proximity relations. in this paper, a systematic proximity elicitation method are proposed. The proposed generation method is simple and systematic. It is based on the well-known fuzzy set theory and applicable to the real world applications because it has tuning parameter and weighting factor. The proposed representations of proximity relation is more efficient than the ordinary matrix representation since it reflects some properties of a proximity relation to save space. We show an experiments of quantitative calculate for the proximity relation. And we analyze the time complexity and the space occupancy of the proposed representation method.

유전자 알고리즘과 합성 성능지수에 의한 최적 퍼지-뉴럴 네트워크 구조의 설계 (The Design of Optimal Fuzzy-Neural networks Structure by Means of GA and an Aggregate Weighted Performance Index)

  • 오성권;윤기찬;김현기
    • 제어로봇시스템학회논문지
    • /
    • 제6권3호
    • /
    • pp.273-283
    • /
    • 2000
  • In this paper we suggest an optimal design method of Fuzzy-Neural Networks(FNN) model for complex and nonlinear systems. The FNNs use the simplified inference as fuzzy inference method and Error Back Propagation Algorithm as learning rule. And we use a HCM(Hard C-Means) Clustering Algorithm to find initial parameters of the membership function. The parameters such as parameters of membership functions learning rates and momentum weighted value is proposed to achieve a sound balance between approximation and generalization abilities of the model. According to selection and adjustment of a weighting factor of an aggregate objective function which depends on the number of data and a certain degree of nonlinearity (distribution of I/O data we show that it is available and effective to design and optimal FNN model structure with a mutual balance and dependency between approximation and generalization abilities. This methodology sheds light on the role and impact of different parameters of the model on its performance (especially the mapping and predicting capabilities of the rule based computing). To evaluate the performance of the proposed model we use the time series data for gas furnace the data of sewage treatment process and traffic route choice process.

  • PDF