• Title/Summary/Keyword: Fusion Weight

Search Result 257, Processing Time 0.024 seconds

Enhanced dissolution rates of piroxicam from the ground mixtures with chitin or chitosan

  • Koh, Ik-Bae;Shin, Sang-Chul;Lee, Yong-Bok
    • Archives of Pharmacal Research
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1986
  • To increase the dissolution rate of piroxicam, chitin and chitosan which are widely occurring biodegradable natural materials were used as drug carriers. The ground mixtures of piroxicam with chitin or chitosan were prepared by grinding in a ball mill. The dissolution rates of piroxicam from the ground mixtures were enhanced markedly than that from the physical mixtures or from intact piroxicam. The X-ray diffraction peaks disappeared in the ground mixture indicating the production of the amorphous form. The comparison of infrared spectra of the physical mixture and the ground minture showed an interaction such as association between the functional groups of piroxicam and chitin or chitosan in the molecular level. The weight losses in TGA curves shoed all the same patterns. However, in the ground mixture by DTA curve, the undothermic peak due to the fusion of piroxicam was disappeared indicating the different thermal property.

  • PDF

Solitary Lymphoblastic Lymphoma of the Thoracic Spine

  • Park, Dong Am;Park, Sang Gon;Kim, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.6
    • /
    • pp.564-566
    • /
    • 2012
  • Non-Hodgkin's lymphoma rarely originates from bone, and even more infrequently from a vertebral body. Lymphoblastic lymphoma is a rare type of non-Hodgkin's lymphoma, and results from an abnormality in adaptive immune cells. A 27-year-old man presented with a two-month history of night sweats, weight loss, and severe back pain. Radiological studies demonstrated an osteolytic lesion compressing the subarachnoid space at the T11 level. Posterolateral fusion with decompression was performed and a pathologic examination confirmed lymphoblastic lymphoma of the B-cell precursor type. To our knowledge, this is the first report of solitary lymphoblastic lymphoma from B-cell precursors in of the thoracic spine. Herein, we discuss the presenting symptoms and the management of this rare case of lymphoblastic lymphoma.

Study on Physicochemical Characteristics and Bioavailability of Fenbufen Suppositories (Fenbufen 좌제(坐劑)의 물리화학적(物理化學的) 성상(性狀) 및 생체이용률(生體利用率)에 관(關)한 연구(硏究))

  • Kim, Johng-Kap;Hong, Soun-Uk
    • Journal of Pharmaceutical Investigation
    • /
    • v.14 no.2
    • /
    • pp.55-61
    • /
    • 1984
  • This investigation was designed to determine the release of fenbufen from suppositories and their bioavailability in rabbits. Suppositories containing fenbufen were made by the fusion method with Witepsol H-15, Wecobee and PEG 1540 base. Displacement value, weight variation, content uniformity, melting point and melting time were determined for preformulation of the fenbufen suppositories. The release rates were determined with the KP dissolution apparatus and with cellophane tube dialysis device and were increased in order of PEG 1540, Witespol H-15 and Wecobee. The bioavailabilities of fenbufen after rectal administration were also increased in order of PEG 1540, Witespol H-15 and Wecobee.

  • PDF

A Study on the Laser Beam Weldability Using Zircaloy-4 Cladding Tube (지르칼로이-4 피복관을 이용한 레이저용접성 연구)

  • 박진석;김동균;김상태;양명승;김수성;이정원
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.72-72
    • /
    • 2002
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and find the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test(400℃), the fracture is not happened in the welding part but base metal and the result of corrosion test(400℃ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.

A Study on the Laser Beam Weldability Using Zircaloy-4 Cladding Tube (지르칼로이-4 피복관을 이용한 레이저용접성 연구)

  • 박진석;김동균;김상태;양명승;김수성;이정원
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.796-801
    • /
    • 2002
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and find the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test($400^{\circ}C$), the fracture is not happened in the welding part but base metal and the result of corrosion test($400^{\circ}C$ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.

A Paired Barrel Capable of Automatic Storage and Emptying of Water for a Weighing Raingauge (자동 저수와 배수가 가능한 중량 우량계 용 쌍수조)

  • Lim, Gyu-Ho;Lim, Eun Ok
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.251-258
    • /
    • 2017
  • The standard weighing raingauges have a capacity limit in measuring the amounts of precipitation. Exceptions are those using a siphon to drain the collected water during observations. To reduce the drain time of the siphon type or to overcome the hassles associated with the manual emptying of the bucket for measuring, the most of weighing gauges use a large bucket for storing of rainwater to be measured. To avoid the above-mentioned adverse requirements, we propose a paired barrel for a weighing raingauge. The paired barrel may improve the accuracy of the weighing raingauges by getting rid of their capacity limit and make the gauges smaller in size and lighter in weight than the conventional ones. We showed its proper function and the feasibility of realization by testing a prototype paired barrel.

Implementation and Balancing Control of A Single-wheel Mobile Robot Using Air Power (바람의 힘을 이용한 외바퀴 이동 로봇의 구현 및 균형제어)

  • Sim, Yong-Gi;Jung, Seul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.139-144
    • /
    • 2014
  • This paper presents the novel design, implementation and control of a single-wheel mobile robot that can balance by using air power from ducted fans. All of the motions of the single-wheel mobile robot are actuated by air power instead of motor torques. Using air power allows to reduce the total weight of the robot. The complementary sensor fusion algorithm is introduced to estimate the angle correctly. After several design and development, the robot is tested for balancing in the roll direction and yawing motion. In addition, the balancing control of the robot on a single rope is tested to evaluate the control performance.

Shielding analyses supporting the Lithium loop design and safety assessments in IFMIF-DONES

  • Gediminas Stankunas ;Yuefeng Qiu ;Francesco Saverio Nitti ;Juan Carlos Marugan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1210-1217
    • /
    • 2023
  • The assessment of radiation fields in the lithium loop pipes and dump tank during the operation were performed for International Fusion Materials Irradiation Facility - DEMO-Oriented NEutron Source (IFMIF-DONES) in order to obtain the radiation dose-rate maps in the component surroundings. Variance reduction techniques such as weight window mesh (produced with the ADVANTG code) were applied to bring the statistical uncertainty down to a reasonable level. The biological dose was given in the study, and potential shielding optimization is suggested and more thoroughly evaluated. The MCNP Monte Carlo was used to simulate a gamma particle transport for radiation shielding purposes for the current Li Systems' design. In addition, the shielding efficiency was identified for the Impurity Control System components and the dump tank. The analysis reported in this paper takes into account the radiation decay source from and activated corrosion products (ACPs), which is created by d-Li interaction. As a consequence, the radiation (resulting from ACPs and Be-7) shielding calculations have been carried out for safety considerations.

The impact fracture behaviors of CFRP/EVA composites by drop-weight impact test

  • Go, Sun-Ho;Kim, Hong-Gun;Shin, Hee-Jae;Lee, Min-Sang;Yoon, Hyun-Gyung;Kwac, Lee-Ku
    • Carbon letters
    • /
    • v.21
    • /
    • pp.23-32
    • /
    • 2017
  • A drop weight impact test was conducted in this study to analyze the mechanical and thermal properties caused by the changes in the ratio of carbon fiber reinforced plastic (CFRP) to ethylene vinyl acetate (EVA) laminations. The ratios of CFRP to EVA were changed from 10:0 (pure CFRP) to 9:1, 8:2, 6:4, and 5:5 by manufacturing five different types of samples, and at the same time, the mechanical/thermal properties were analyzed with thermo-graphic images. As the ratio of the CFRP lamination was increased, in which the energy absorbance is dispersed by the fibers, it was more likely for the brittle failure mode to occur. In the cases of Type 3 through Type 5, in which the role of the EVA sheet is more prominent because it absorbs the impact energy rather than dispersing it, a clear form of puncture failure mode was observed. Based on the above results, it was found that all the observation values decreased as the EVA lamination increased compared with the CFRP lamination. The EVA lamination was thus found to have a very important role in reducing the impact. However, the strain and temperature were inversely propositional.

Treatment of Surgical Site Infection and Delayed Union in Fetlock Arthrodesis of a Mare

  • Lee, Sang-Kyu;Kim, Jinyoung;Seo, Jong-pil;Lee, Inhyung;Kang, Byung-Jae
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.157-162
    • /
    • 2020
  • A 6-year-old Thoroughbred mare presented to the Korea Racing Authority Equine Hospital with dropping of the left front fetlock due to an injury sustained while racing. Radiographic examination revealed a comminuted fracture of both proximal sesamoid bones of the affected fetlock. Arthrodesis of the fetlock joint using a broad dynamic compression plate with a tension band wire was performed as a salvage procedure for the future use as a broodmare. After surgery, however, a delayed union of the bones and surgical site infection was present for a prolonged period. Staphylococcus aureus was persistently identified from the surgical site, and antimicrobial therapies were based on antibiotic sensitivity tests, including regional perfusions. The removal and replacement of surgical implants associated with seropurulent discharge was based on coordinating the development of fetlock ankylosis and infection control over 13 months. Firstly, seven screws associated with surgical drainage were replaced and bone morphogenetic protein-2 (BMP-2) and local antibiotics were placed into the surgical site to accelerate bone fusion at postoperative month 7. Further six screws, along with drainage, were removed at postoperative month 10. The plate and screws were removed from the limb due to the progression of bone fusion at postoperative month 13; BMP-2 and local antibiotics were also used. Delayed healing of arthrodesis due to surgical site infection and implant instability were treated by implant removals and antibiotic therapies, and the horse eventually showed improved weight-bearing ability of the affected limb.