• 제목/요약/키워드: Fusion Technique

검색결과 648건 처리시간 0.032초

Intelligent Healthcare Service Provisioning Using Ontology with Low-Level Sensory Data

  • Khattak, Asad Masood;Pervez, Zeeshan;Lee, Sung-Young;Lee, Young-Koo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권11호
    • /
    • pp.2016-2034
    • /
    • 2011
  • Ubiquitous Healthcare (u-Healthcare) is the intelligent delivery of healthcare services to users anytime and anywhere. To provide robust healthcare services, recognition of patient daily life activities is required. Context information in combination with user real-time daily life activities can help in the provision of more personalized services, service suggestions, and changes in system behavior based on user profile for better healthcare services. In this paper, we focus on the intelligent manipulation of activities using the Context-aware Activity Manipulation Engine (CAME) core of the Human Activity Recognition Engine (HARE). The activities are recognized using video-based, wearable sensor-based, and location-based activity recognition engines. An ontology-based activity fusion with subject profile information for personalized system response is achieved. CAME receives real-time low level activities and infers higher level activities, situation analysis, personalized service suggestions, and makes appropriate decisions. A two-phase filtering technique is applied for intelligent processing of information (represented in ontology) and making appropriate decisions based on rules (incorporating expert knowledge). The experimental results for intelligent processing of activity information showed relatively better accuracy. Moreover, CAME is extended with activity filters and T-Box inference that resulted in better accuracy and response time in comparison to initial results of CAME.

용접부 비파괴 검사의 신뢰성 비교: 화력 발전소의 보일러 수냉벽 배관 사례연구 (Comparative Reliability of Nondestructive Testing for Weld: Water Wall Tube in Thermal Power Plant Boiler Case Study)

  • 최창덕;임익성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권3호
    • /
    • pp.240-249
    • /
    • 2018
  • Purpose: The purpose of this research is to find which technique, between the PAUT (Phased array ultrasonic test) that has been used widely in practice and RT (Radiographic test) that was used widely in the past, has the higher reliability as a non-destructive testing of welding points in water wall tubes. Methods: To evaluated the reliability of non-destructive testing, eleven test pieces that were fabricated intentionally, which have the most frequently occurred defect types in water wall tubes and then both the PAUT and RT were performed on those eleven test pieces to compare their reliability. Results: The differences of type of defect, length are occurred due to the characteristics of nondestructive testing. The RT could not detect the lack of fusion defect type in specimen #4 and #8 while PAUT could not detect the lateral crack and 1 mm size small porosity in specimen #11. Conclusion: It is concluded that applying both the RT and PAUT result the best reliability rather than applying only one test method, if it is possible, in nondestructive testing of weld water wall tube in thermal power plant boiler case.

환추-축추 불안정성에 있어서 후방 경관절 나사못 고정술에 대한 수술적 경험 (Surgical Experience with Posterior Atlantoaxial Transarticular Screw Fixation in Atlantoaxial Instability)

  • 차승규;유찬종
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권1호
    • /
    • pp.95-100
    • /
    • 2000
  • Objective : Posterior transarticular screw fixation is known to be one of the best surgical method for the atlantoaxial instability. We assessed the complication and operative risk in 15 patients. Patients and Methods : Between January 1997 and April 1998, 15 patients suffering from this condition were admitted to our institution. Atlantoaxial instability was caused by C1 or C2 fractures in 11, rheumatoid arthritis in 2, and os odontoideum in 2. This technique was used in the treatment of 13 patients and 2 patients was used in sublaminar wire fixation only. Bilateral C1-C2 screws were placed in 11 patients ; 2 patients had only one screw placed becauce of an anomalous vertebral artery and axial destruction. Follow-up period ranged from 5 to 20 months. Results : Most screws were positioned satisfactorily. One screw was malpositioned. No patients had neurological complications. Conclusion : Rigidly fixating C1-C2 instability with transarticular screws showed a significantly higher fusion rate than that achieved using wired grafts alone. The risk of screw malpositioning and catastrophic vascular or neural injury is small and can be minimized by assessing the position of the transverse foramen on preoperative computed tomographic scans and by correctly using intraoperative fluoroscopy and surgeon's precaution.

  • PDF

Caving Disaster and Oil Spill Removal Adsorbent Mag-Sorbent

  • Soh, Dea-Wha;Soh, Hyun-Jin;Soh, Hyun-Jun;Soh, Hyun-Jae
    • 동굴
    • /
    • 제85호
    • /
    • pp.28-34
    • /
    • 2008
  • For trying to frontal attack of new solution by fusion of technical tasks and conditions with it's solving methods of the essential tasks of marine resource development and environmental conservation in addition with elements of electronic high-technologies, the magnetic oil spill adsorbent of Mag-Sorbent* has been prepared and proposed to dispose oil spill from the marine disaster for preventing oil pollution by using them and their system with sequentially circular collection of oil spill mag-sorbent powder and fabrics on the electronic equipment like as barge robot for the scheme of sustainable development of environment-friendly technology. Because of recent marine accident occurred at Tae-An cost and earthquake in Sichuan province were very large scale accident of disaster to prevent and manage of them. So, it was verified from the experiment of electronic demonstrator that the skimmer system of oil spill mag-sorbent powder and fabrics prepared was very effective and useful technique to collect oil spill samples on the water surface specially at the closed space of underground cave. At this point, the barge-based electronic remote control was very useful system operating easily on the marine fields but also water level at the small pool to skim it with the environment-friendly system of the disposing marine disaster and preventing oil pollution using magnetic adsorbents of Mag-Sorbent*.

Innovation in Telecom Services -Framework and Analysis Based on the Case of International Pre-paid Calling Cards in Japan

  • Kumiko, Miyazaki;Wiggers, Edmar
    • 기술혁신연구
    • /
    • 제13권2호
    • /
    • pp.45-70
    • /
    • 2005
  • Much work on innovation has focused on the manufacturing sector. In this paper, we propose a framework for analyzing innovation in services centred on capability and technology integration. We illustrate the theoretical points made by conducting a case study on an international telephone communications provider Brastel, which introduced significant innovations in international calling services, in the form of rechargeable pre-paid calling card, through effective application of standard IT. Brastel is situated against its main competitors, considering two dimensions of price and service breadth and convenience. A novel technique for measuring competitiveness based on price and service index is introduced. The following competitors were selected: NTT, KDDI, Japan Telecom, Fusion Communications, J-Call / World Link, G-Call, ASP Check, Primus, QuickPhone, and MCI. To create the service index, factors such as ease of use, convenience, number of languages in which the services are available, and additional features were taken into account. The company itself and the rechargeable card innovation were analyzed through in-depth interviews and data collection. It was shown that a competitive advantage was maintained through internal and external capabilities.

  • PDF

Propagation of lymphocystis disease virus (LCDV) in the FIN cell line originated from olive flounder Paralichthys olivaceus fin

  • Hossain, Mosharrof;Kim, Wi-Sik;Jung, Sung-Ju;Oh, Myung-Joo
    • 한국어병학회지
    • /
    • 제24권2호
    • /
    • pp.47-51
    • /
    • 2011
  • The present study demonstrated lymphocystis disease virus (LCDV) propagation through cytopathic effects (CPE) formation and LCDV detection in olive flounder fin (FFN) cells by polymerase chain reaction (PCR) and fluorescent antibody technique (FAT) methods. Tissue filtrates from the cluster cells produced CPE in FFN cells, which initially cells became enlarged and gradually underwent fusion en masse. Infectivity of culture grown LCDV using the FFN cells reached $10^{2.3}$ $TCID_{50}$/ml at 4 days post infection and the highest titer was measured $10^{6.5}$ $TCID_{50}$/ml at 12 days. The viral DNA was detected in the cell culture supernatants showing CPE and the CPE cells by PCR. Antigen specific strong fluorescence reacting with monoclonal antibody against the virus revealed the presence of viral antigen in the cytoplasm of infected FFN cells. These results suggest that the FFN cell line originated from the olive flounder has a susceptibility of the LCDV.

초음파 거리 센서의 계측오차 감소를 위한 연구 (A study to reduce measurement errors of an ultrasonic rangefinder)

  • 도용태;김태호;유석환
    • 전자공학회논문지S
    • /
    • 제34S권11호
    • /
    • pp.43-52
    • /
    • 1997
  • Ultrasonic sensors are widely employed in detecting range to a target by the virtue of their low cost and simplicity. However, the sensor's measurements are corrupted by systematic errors due mainly to the dependency of sound speed upon surrounding conditions and random errors of uncertain origin. In this paper, we present the results of research carried out to reduce these errors for increasing the reliability of an untrasonic sensor system to be used in orbotic or other automated system's range finding. The sensor system designed herein is in a peuliar structure having a reference target and two receivers. Echoes from a small reference target placed at a known distance are used for compensating the variations of sound speed according to the changes of sensing conditions. Unlike existing ones, the technique proposed can compensate the effects of temperature or any other physical parameters without an additional sensor dedicated to the compensation. The measurements by two redundantly employed receivers are fused to reduce random errors in a statistical sense. The correlation of the signals from the receivers sharing a hardware in part is considered in the fusion process. The methodology desicribed in this paepr is conceptually simple, easy to be implemented, and effetive to increase the accuracy of the sensor measurements as experimental results confirm.

  • PDF

Nucleolar translocalization of GRA10 of Toxoplasma gondii transfectionally expressed in HeLa cells

  • Ahn, Hye-Jin;Kim, Sehra;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • 제45권3호
    • /
    • pp.165-174
    • /
    • 2007
  • Toxoplasma gondii GRA10 expressed as a GFP-GRA10 fusion protein in HeLa cells moved to the nucleoli within the nucleus rapidly and entirely. GRA10 was concentrated specifically in the dense fibrillar component of the nucleolus morphologically by the overlap of GFP-GRA10 transfection image with IFA images by monoclonal antibodies against GRA10 (Tg378), B23 (nucleophosmin) and C23 (nucleolin). The nucleolar translocalization of GRA10 was caused by a putative nucleolar localizing sequence (NoLS) of GRA10. Interaction of GRA10 with TATA-binding protein associated factor 1B (TAF1B) in the yeast two-hybrid technique was confirmed by GST pull-down assay and immunoprecipitation assay. GRA10 and TAF1B were also co-localized in the nucleolus after co-transfection. The nucleolar condensation of GRA10 was affected by actinomycin D. Expressed GFP-GRA10 was evenly distributed over the nucleoplasm and the nucleolar locations remained as hollows in the nucleoplasm under a low dose of actinomycin D. Nucleolar localizing and interacting of GRA10 with TAF1B suggested the participation of GRA10 in rRNA synthesis of host cells to favor the parasitism of T. gondii.

초음파원자현미경을 이용한 나노스케일 박막 코팅층에 대한 탄성특성 평가 (Evaluation of Elastic Properties for Nanoscale Coating Layers Using Ultrasonic Atomic Force Microscopy)

  • 곽동열;조승범;박익근
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.475-480
    • /
    • 2015
  • Ultrasonic atomic force microscopy (Ultrasonic-AFM) has been used to investigate the elastic property of the ultra-thin coating layer in a thin-film system. The modified Hertzian theory was applied to predict the contact resonance frequency through accurate theoretical analysis of the dynamic characteristics of the cantilever. We coat 200 nm thick Aluminum and Titanium thin films on the substrate using the DC Magnetron sputtering method. The amplitude and phase of the contact resonance frequency of a vibrating cantilever varies in response to the local stiffness constant. Ultrasonic-AFM images were obtained using the variations in the elastic property of the materials. The morphology of the surface was clearly observed in the Ultrasonic-AFM images, but was barely visible in the topography. This research demonstrates that Ultrasonic-AFM is a promising technique for visualizing the distribution of local stiffness in the nano-scale thin coatings.

Residual stresses measurement in the butt joint welded metals using FSW and TIG methods

  • Taheri-Behrooz, Fathollah;Aliha, Mohammad R.M.;Maroofi, Mahmood;Hadizadeh, Vahid
    • Steel and Composite Structures
    • /
    • 제28권6호
    • /
    • pp.759-766
    • /
    • 2018
  • Friction Stir Welding (FSW) is a solid-state process, where the objects are joined together without reaching their melting point. It has been shown that this method is a suitable way to join dissimilar aluminium alloys. The current article employed hole drilling technique to measure the residual stress distribution experimentally in different zones of dissimilar aluminium alloys AA6061-T6 and AA7075-T6 Butt welded using FSW. Results are compared with those of similar AA6061-T6 plates joined using a conventional fusion welding method called tungsten inert gas (TIG). Also, the evolution of the residual stresses in the thickness direction was investigated, and it was found that the maximum residual stresses are below the yield strength of the material in the shoulder region. It was also revealed that the longitudinal residual stresses in the joint were much larger than the transverse residual stresses. Meanwhile, Vickers micro hardness measurements were performed in the cross-section of the samples. The largest hardness values were observed in the stir zone (SZ) adjacent to the advancing side whereas low hardness values were measured at the HAZ of both alloys and the SZ adjacent to the retreating side.