• 제목/요약/키워드: Fused Teeth

검색결과 60건 처리시간 0.037초

Role of cone-beam computed tomography in the evaluation of a paradental cyst related to the fusion of a wisdom tooth with a paramolar: A rare case report

  • Ozcan, Gozde;Sekerci, Ahmet Ercan;Soylu, Emrah;Nazlim, Sinan;Amuk, Mehmet;Avci, Fatma
    • Imaging Science in Dentistry
    • /
    • 제46권1호
    • /
    • pp.57-62
    • /
    • 2016
  • Fusion is an abnormality of tooth development defined as the union of two developing dental germs, resulting in a single large dental structure. This irregular tooth morphology is associated with a high predisposition to dental caries and periodontal diseases. As a result of recurring inflammatory periodontal processes, disorders such as periodontal pocket, pericoronitis, and paradental cysts may develop. A rare mandibular anatomic variation is the retromolar canal, which is very significant for surgical procedures. The fusion of a paramolar and mandibular third molar associated with a paradental cyst co-occurring with the presence of a retromolar canal is rare, and the aim of the present study is to describe the evaluation of this anatomical configuration using cone-beam computed tomography.

C-shaped canal의 절단면 분석을 통한 근관형태의 변화와 근관과 치아외벽간의 최소거리 분석에 관한 연구 (CROSS-SECTIONAL MORPHOLOGY AND MINIMUM CANAL WALL WIDTHS IN C-SHAPED ROOT OF MANDIBULAR MOLARS)

  • 송병철;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제32권1호
    • /
    • pp.37-46
    • /
    • 2007
  • C-shape 근관은 주로 하악 제 2대구치에서 보이는 해부학적 변이 형태로서, 그 특징은 각 근관을 연결하는 fin이나 web이 존재한다. 이런 해부학적으로 복잡함은 근관치료시에 세정과 성형 및 근관충전을 방해하며, 과다한 기구 조작시에 뜻하지 않는 천공을 유발하기도 한다. 이 연구의 목적은 C-shape 치근을 가진 하악 제2 대구치의 해부학적인 형태와 치근의 위치에 따른 최소 근관벽 두께에 대하여 연구하고자 하였다. 발거된 하악 대구치중 C-shape 치근을 가진 치아를 30개 선별하여 방사선 사진 및 협측, 설측, 치근단 부위를 디지털 카메라를 이용하여 촬영하였다. 자가 중합형 교정용 레진 (Orthodontics resin, Densply/Caulk, U.S.A)을 이용하여 치관부를 제거한 치아를 매몰한 후 각각의 시편을 Accutom-50 (Struers, Denmark)에 고정시켜 1 mm 간격으로 절단, 연마한 다음 절단면을 수술용현미경에 연결된 디지털 카메라 (Coolpix 995, Nikon, Tokyo, Japan)를 이용하여 각각의 상을 촬영하였다. 30개 치아에서 촬영한 197개의 치아단면을 Root thickness gauge program을 이용하여 근관형태의 변화를 분류하고 부위별 근관과 치아외벽 사이에 존재하는 상아질의 최소두께에 대해 연구 분석하였다. 1. 근관입구에서 C I이 가장 많이 (73%) 관찰되었으나 치근단부로 갈수록 근관 형태의 다양한 변화를 보여 C II와 C III의 근관형태가 많이 관찰되었으며, 11 개의 (36%)치아에서는 근관입구에서 치근단부까지 근관형태의 변화를 보이지 않았다. 근관입구에서 단지 2개의 치아에서 나타난 C III type은 치근단부로 갈수록 높은 발현빈도를 나타내었다. 2. C-shape 근관은 근관입구 부위에서는 continuous 나 semicolon canal을 가지나 치근단부로 갈수록 2개나 3개의 근관을 갖는 경우가 많다. 3.평균적인 근관과 치질사이의 최소거리는 근첨부의 설측부위에서 나타났다.

강화형 복합레진과 수종의 치과용 합금간의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of the Reinforced Composite Resin to Dental Alloys)

  • 김정희;조인호
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.113-122
    • /
    • 2000
  • The reinforced composte resin as the esthetic operative material continuously has been studied because the porcelain fused metal prosthesis is widely used for its excellent esthetics, rigidity and marginal integrity, but it has low fracture resistance against the tensile strength and stress, attrition of the opposite teeth. The reinforced composite resin is well adapt with the dental alloy but it is low the shear bond strength with the dental alloy vs the porcelain fused metal prosthesis, and then has been studied continuously. The purpose of the study was to examine how metal was the higher shear bond strength among the dental alloy was used to the reinforced composite resin and to find the effect that the particle size of sandblasting influenced the shear bond strength. We built up the reinforced composite resin with 4 mm in diameter, 3 mm in height on circular alloy with 5 mm in diameter, 2 mm in height. Type II gold, type IV gold, and Ag-Pd alloy was used as alloys and $50{\mu}m$, $110{\mu}m$, $250{\mu}m$ of the particle size was sandblasted at each alloy in bonding between alloy and resin. We made 90 secimens of 10 per each group and we measured the shear bond strength using the Instron($M100EC^{(R)}$, Mecmesin Co., England). The obtained results were as follows : 1. In comparison among each alloys, Ag-Pd alloy had the highest shear bond strength and the shear bond strength was decreased significantly in the sequence of the type II gold and type IV gold(P<0.001). 2. In comparison according to the size of sandblasting particle, (1) In Ag-Pd alloy, shear bond strength was decreased in the sequence of $110{\mu}m$, $250{\mu}m$, $50{\mu}m$ and there were significant difference in all the group. (P<0.05) (2) In type II gold, it was decreased in the sequence of $250{\mu}m$, $50{\mu}m$, $110{\mu}m$ and there were significant difference. (P<0.05) (3) In type IV gold, it was decreased in the sequence of $110{\mu}m$, $50{\mu}m$, $250{\mu}m$. There were significant difference between the group of $110{\mu}m$ and $50{\mu}m$, the group of $110{\mu}m$ and 250, but there were no significant difference in the group of $50{\mu}m$ and $250{\mu}m$. 3. The highest shear bond strength according to the size of sandblasting particle was $110{\mu}m$ in Ag-Pd alloy and type IV gold, $250{\mu}m$ in type II gold.

  • PDF

III급 부정교합 환자에서 상악 가철성 국소 의치와 하악 임플란트 지지 고정성 보철물을 이용한 구강 회복 증례 (Rehabilitation of posterior support and vertical dimension in a class 3 malocclusion patient: A case report)

  • 오지환;표세욱;장재승;김선재
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.175-186
    • /
    • 2022
  • 상, 하악에 잔존 치아가 있음에도 불구하고 교합 접촉이 가능한 대합 치아가 없어서 교두 감합위를 상실하게 되는 엇갈린 교합은 결과적으로 수직 고경의 붕괴를 초래한다. 본 증례에서는 엇갈린 교합 및 전치부 반대교합을 동반하는 III급 부정교합 환자를 상악 가철성 국소 의치와 하악 임플란트 지지 고정성 보철물을 이용하여 구강 회복을 진행하였다. 3개월 동안 임시의치의 착용 기간을 거쳐 수직 고경 안정화 및 심미성 개선을 위한 임시 보철물을 제작하였고, 이를 최종 수복물에 반영하기 위하여 전방 유도 테이블의 제작과 수직 고경 및 교합 관계의 유지를 위한 교차 마운팅을 시행하였다. 하악 임플란트 및 상악의 지대치는 금속 도재관을 이용하여 수복하였고, 상악의 편측성 무치악 부위는 국소 의치를 제작하였다. 단계적인 치료 과정을 통해 구치부의 적절한 지지 및 전치부의 반대교합의 해소를 통한 상호보호교합의 교합관계를 형성하였으며, 환자에게 심미적, 기능적인 치과 보철물을 장착함으로써 만족스러운 치료결과를 얻을 수 있었다.

치과보철기공물 제작실태에 관한 조사연구 (A SURVER OF THE ACTUAL CONDITIONS ON THE PRODUCTION OF DENTAL PROSTHESIS)

  • 배정수;정문규
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.358-394
    • /
    • 1995
  • The author studied the actual conditions on the production of dental prosthesis made in laboratories, and also studied interrelationships between dentists and laboratory technicians in both personal and technical aspects. Two hundred-eighty four technicians, work in dental laboratories presently, were surveyed via mail and direct contact during the period from June 1 to June 30 and August 27 to August 28 in 1994 respectively. The obtained results were as follows : 1. Among the respondents, 90.5% we re working in commercial dental laboratories and their laboratories were mainly located in the Seoul area(40.9%, P<0.05). The numbers of employees in these laboratories were less than 10 persons(70.0%, P<0.01), and 75.9% of these laboratories have been in operation less than 15 years. 2. Most laboratory procedures were accomplished according to established disciplines. However, procedures such as die trimming in fixed restorations and the qualifications of the people designing removable partial dentures were not. Other problem areas were boxing of the working cast, the person determining the posterior palatal seal area, selection and arrangement of artificial teeth, occlusion rim correction and laboratory remounting of the processed denture in complete denture restorations. 3. Only half of the requesting dentists could send work authorizations to the laboratories with their work and even so, its contents were quite lacking. Consequently, there must be some standards in writing work authorization. 4. Technicians most desired clean and accurate impressions in fixed and removable dentures, and enough tooth reduction in porcelain fused to metal restorations. 5. For the establishment of better relationships between dentist and dental technician, the respondents desired the establishment of equal footing first(33.5%), and frequent conversations and muture understanding second(25.9%).

  • PDF

치과보철물의 평균수명에 관한 연구 (A Study on the Life Expectancy of the Dental Prosthetic Restorations)

  • Young-Ku Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.317-325
    • /
    • 1995
  • This study was performed to investigate the mean life expectancy of dental prosthetic restorations. The author has examined 352 dental prosthesis clinically and radiologically, and decided the success(survival) and failure(mortality) of the dental prosthesis. The dental prosthesis which had been treated in the Seoul National University Dental Hospital, two private clinics in Seoul, one university dental hospital, and two private clinics in local province were included in this study. The survival analysis using product limit estimator was used and the mean life expectancy of each type of dental prosthesis was calculated. The results were as follows : 1. The life expectancies were 10.5 years in gold crown and bridge, 8.5 years in porcelain fused to metal crown and bridge, 8.3 years in nonprecious metal crown and bridge, 8.1 years in removal partial denture, and 7.7 years in full denture. 2. The causes of mortality were in the order of dental caries(24.6%), fracture of dental prosthesis(19.2%), periodontal problems(18.6%), chronic chewing difficulty and dysfunction due to dental prosthesis(15.0%), excessive exposure of abutments due to the marginal defect of dental prosthesis(14.4%), abnormal occlusion due to severe attrition of artificial teeth in dentures(3.0%), periapical problems(2.4%), perforation of dental prosthesis(1.8%), and loose contacts with neighboring tooth(1.2%). 3. Among survival cases, 66.5% showed normal chewing ability and 31.9% showed partial chewing ability. However, 1.6% of them complained loss of chewing ability. 4. Among failure cases, 6.6% showed normal chewing ability and 38.9% showed partial chewing ability. However, 54.5% of them complained loss of chewing ability.

  • PDF

Brånemark 골유착성 매식체의 금관 수복재료에 따른 지지조직의 응력분석 (The stress analysis of supporting tissues according to crown restorative materials in Brånemark osseointegrated implant)

  • 정관호;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.199-215
    • /
    • 1990
  • This study was to analyze the stress distribution of implant and supporting tissue in $Br{\aa}nemark$ osseointegration implant. The analysis has been conducted by using the axisymmetric finite element method and type of model according to crown material. Tests have been performed at 1 kg load on central fossa of crown portion. Each type of model was designed differently according to crown material. 1) Porcelain fused to metal crown(Model A) 2) Composite resin veneered crown(Model B) 3) Acrylic resin veneered crown(Model C) 4) Type III gold crown(Model D) The displacements and stresses of implant and supporting structures were analyzed to investigate the influence of the type of crown material. The results were obtained as follows : 1. Displacement of implant was shown uniformly downward displacement in all models and abutments were observed distally downward displacement. 2. In supporting tissues, stress was concentrated on the crest of compact bone and the spongy bone below implant. 3. The PFM and the type III gold crown showed the largest concentration of stress at the crest of compact bone and the spongy bone below implant, respectively. Acrylic resin artificial teeth and composite resin veneered crown indicated almost the same distribution of stress. 4. The gold screw, the abutment screw and the top of abutment showed the concentration of stress in implants of every model.

  • PDF

인위적 정출술과 임플란트 치료를 통한 상악 전치부 보철치료 (Prosthetic restoration of the maxillary anterior teeth using implantation and forced eruption: Case report)

  • 김경규
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.80-86
    • /
    • 2011
  • 임플란트 인접치아가 심한 치아우식이나 파절 등으로 인해 치관부의 잔존 치질이 손상된 경우 인위적 맹출술을 이용한 치관연장술은 임플란트와 인접한 치조골과 치간 유두의 보존으로 심미적인 보철 치료를 가능하게 한다. 54세 남자 환자분이 상악 전치부 고정성 보철물의 탈락으로 새로운 보철 치료를 주소로 내원하셨다. 상악 우측 중절치는 경도의 치아우식만 보였고 상악 우측 견치는 치관부 치질이 대부분 소실되어 있었다. 상악 우측 측절치의 결손부는 골 이식을 동반한 임플란트 식립을 시행하였고, 상악 우측 견치는 1달간 인위적 맹출술을 통한 치관연장술을 시행하였다. 임플란트 식립 5개월 후 2차 수술을 시행하였고, 임시치아의 단계적 수정을 통한 치은 성형 후 상악 우측 중절치, 상악 우측 측절치, 상악 우측 견치 각각 금속-도재관으로 수복하여 만족할 만한 임상결과를 얻을 수 있었다.

금속의 두께가 도재의 파절강도에 미치는 영향 (A study on the difference of Ceramic fracture strength according to the metal depth)

  • 신무학;최운재;김용원
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.89-95
    • /
    • 2005
  • In the manufacture of ceramo-metal crown, difference of fracture strength according to the metal depth has been known to be an important influence on enough intensity and internal stress to endure an occlusion-pressure as well as aesthetics of rehabilitating similar colour such as natural teeth. Depth of ceramic material could be determined by that of metal in three groups: first case of thin depth, second case of thick depth, and third case of constant depth. For the enhancement of the fracture strength between metal and ceramic materials and aesthetic satisfaction, a study on the bonding force, fracture strength, and aesthetics have been required more. In this study, therefore metal coping were made in three groups of A, B and C by using both ceramic powder of Norithe and metal of Columbium, which have been used primarily in the market. A group was made in $0.2mm\times10mm\times10mm$, B group was made in $0.4mm\times10mm\times10mm$, and, C group was made in $0.8mm\times10mm\times10mm$, respectively. The number of metal coping in each group was 10, and total sample numbers used in this study were 30 metal copings. After these metal coping tissue were in the process of build-up in 1.5mm constant depth of porcelain, firing, and glazing, the fracture strength about each metal coping tissue was investigated using oil press. It was found that the average values of durable occlusion pressure for separation of ceramic material in the porcelain fused to metal crown (PFM) in the each group showed the increasing order of A group (30 bar), B group (42 bar), and C group (44 bar), respectively. Proper depth of metal coping in the PFM was considered to be 0.4mm in the B group because this metal size showed higher durable property to the occlusion pressure and better coupling strength in the ceramo-metal crown.

  • PDF

Effect of core design on fracture resistance of zirconia-lithium disilicate anterior bilayered crowns

  • Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.181-188
    • /
    • 2020
  • PURPOSE. The effect of core design on the fracture resistance of zirconia-lithium disilicate (LS2) bilayered crowns for anterior teeth is evaluated by comparing with that of metal-ceramic crowns. MATERIALS AND METHODS. Forty customized titanium abutments for maxillary central incisor were prepared. Each group of 10 units was constructed using the same veneer form of designs A and B, which covered labial surface to approximately one third of the incisal and cervical palatal surface, respectively. LS2 pressed-on-zirconia (POZ) and porcelain-fused-to-metal (PFM) crowns were divided into "POZ_A," "POZ_B," "PFM_A," and "PFM_B" groups, and 6000 thermal cycles (5/55 ℃) were performed after 24 h storage in distilled water at 37 ℃. All specimens were prepared using a single type of self-adhesive resin cement. The fracture resistance was measured using a universal testing machine. Failure mode and elemental analyses of the bonding interface were performed. The data were analyzed using Welch's t-test and the Games-Howell exact test. RESULTS. The PFM_B (1376. 8 ± 93.3 N) group demonstrated significantly higher fracture strength than the PFM_A (915.8 ± 206.3 N) and POZ_B (963.8 ± 316.2 N) groups (P<.05). There was no statistically significant difference in fracture resistance between the POZ_A (1184.4 ± 319.6 N) and POZ_B groups (P>.05). Regardless of the design differences of the zirconia cores, fractures involving cores occurred in all specimens of the POZ groups. CONCLUSION. The bilayered anterior POZ crowns showed different fracture resistance and fracture pattern according to the core design compared to PFM.