• 제목/요약/키워드: Fundamental performance

Search Result 1,775, Processing Time 0.044 seconds

Limitations of Applying Land-Change Models for REDD Reference Level Setting: A Case Study of Xishuangbanna, Yunnan, China (REDD 기준선 설정 시 토지이용변화 예측모형 적용의 한계: 중국 운남성 시솽반나 열대림 사례를 중심으로)

  • Kim, Oh Seok
    • Journal of the Korean Geographical Society
    • /
    • v.50 no.3
    • /
    • pp.277-287
    • /
    • 2015
  • This paper addresses limitations of land-change modeling application in the context of REDD (Reducing Emissions from Deforestation and forest Degradation). REDD is an international conservation policy that aims to protect forests via carbon credit generation and trading. In REDD, carbon credits are generated only if there is measurable quantied carbon sequestration activities that are additional to business-as-usual (BAU). A "reference level" is defined as simulated baseline carbon emissions for the future under a BAU scenario, and predictive land-change modeling plays an important role in constructing reference levels. It is tested in this research how predictive accuracies of two land-change models, namely Geographic Emission Benchmark (GEB) and GEOMOD, vary with respect to different spatial scales: Xishuangbanna prefecture and Yunnan province. The accuracies are measured by Figure of Merit. In this Chinese case study, it turns out that GEB's better performance is mainly due to quantity (e.g., how many hectares of forest will be converted to agricultural land?) rather than spatial allocation (e.g., where will the conversion happen?). As both quantity and allocation are crucial in REDD reference level setting it appears to be fundamental to systematically analyze accuracies of quantity and allocation independently in pursuit of accurate reference levels.

  • PDF

Development of Community Health Nursing Service Model: - Based on the Visiting Nurses Project in Seoul, Kyonggi, and Kang-won Area- (지역사회 간호 서비스 전달 체계 모형 개발 -가정방문서비스를 중심으로-)

  • Kim, Sung-Sil
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.361-374
    • /
    • 2001
  • This study was done to identify a status of home visiting project as a community health nursing system, that was the organization. personal who have age, educational background, marital status, position, experience of the home visiting in the public sectors in part of Seoul. Kyonggi, Kang-won area, It was done to provide basis data for the development of effective visiting nurses project in the health sectors, where was Health Centers in urban and rural. Branch of Health Center in rural and Health posts. The question airs were distributed 352 public health workers who working place was 118 health workers in 12 health centers in Seoul. 56 public health workers among 39 health center and other public health sectors in Kyonggi and 178 public health workers among health center and health care sectors. Data collected from October to December. 2000. The analysis by SAS system with F test, percentage and frequency. The major result were as follows. The general characteristics of the respondent show that most of them were graduates from community college and RN-BS with broadcast that they had not completed CPHN course but only two health workers have trained for the visiting nurses project. As for their grade in the position, the most of health workers have seventh level and the other CHP were above sixth level in the health care post that in the government structure. This indicates that workers do not have great authority in decision making, the most period of works in the position was one and two years indicating that they change jobs frequently. On an average their clinical experience was 4.11 years which is ideal for the total service. As for preparation of staff for home visiting workers education on visiting nurses program have to receive short term or longer term training course for strong emphasis. The analysis showed that public health visiting workers responds about active job performance that based on an area, approach of acting by districts, education and position are shown statistically significant difference between acceptance of the visiting nursing job show the same as well as visiting nurses project. Special concerns for visiting Nursing care spread came to burden, many of activity carry out main solution is covered the health problem connective support system needs of quality and quantity which out health problem. As 71.1% of visiting health service held on the poor population was under the guardianship of the law, but people who health insurance wide application under law shown a tendency to increase gradually. The general characteristics of the patients showed 56.2% of female on average of age was 66.1 years old, they have health problem was the most of 47.6% of high blood pressure and stroke, the other and as a problem that economics, which is complex welfare with out health problem. Community health care service should be combined health and social work program. The form of delivery of visiting health care given the most guide and education with counselling and support. (33.6%) Among the six category of visiting care service shown statistically significant difference and next is fundamental care, remedy care with priority.

  • PDF

Effect of Fluorine-Silicate Hybrid Based Crack Reducing Agent on the Resistance for Shrinkage Crack and Gas Permeability of Concrete (불소-실리카 복합형 균열저감제가 콘크리트의 수축균열 저항성 및 투기성에 미치는 영향)

  • Lee, Man-Ik;Park, Jong-Hwa;Nam, Jae-Hyun;Kim, Do-Su;Kim, Jae-On
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.631-637
    • /
    • 2006
  • In this study, fundamental properties such as fresh and hardened performance of concrete mix(specification : 25-24-18) added fluorine-silicate hybrid based crack reducing agent(FS) were measured. Addition of FS ranged from 0.5% to 2.0% at intervals 0.5% based on cement weight. Adequate dosage(0.5%) of FS derived from basic properties measurements applied and compared resistance for shrinkage crack. The permeability of concrete in the absence(24-S-0.0) and presence(24-S-0.5) of evaluated at a mock-up sized concrete. Concrete added FS improved resistance for shrinkage crack and consequently crack number, length and area decreased to $50{\sim}74.4%$ compared non-added. As well, by the addition of FS, the resistance for permeability and penetration depth to concrete surface region increased 67% and 40%, respectively. Therefore it was confirmed that shrinkage crack resistance and permeability of concrete could be improved by the addition of FS.

Evolutionally optimized Fuzzy Polynomial Neural Networks Based on Fuzzy Relation and Genetic Algorithms: Analysis and Design (퍼지관계와 유전자 알고리즘에 기반한 진화론적 최적 퍼지다항식 뉴럴네트워크: 해석과 설계)

  • Park, Byoung-Jun;Lee, Dong-Yoon;Oh, Sung-Kwun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.236-244
    • /
    • 2005
  • In this study, we introduce a new topology of Fuzzy Polynomial Neural Networks(FPNN) that is based on fuzzy relation and evolutionally optimized Multi-Layer Perceptron, discuss a comprehensive design methodology and carry out a series of numeric experiments. The construction of the evolutionally optimized FPNN(EFPNN) exploits fundamental technologies of Computational Intelligence. The architecture of the resulting EFPNN results from a synergistic usage of the genetic optimization-driven hybrid system generated by combining rule-based Fuzzy Neural Networks(FNN) with polynomial neural networks(PNN). FNN contributes to the formation of the premise part of the overall rule-based structure of the EFPNN. The consequence part of the EFPNN is designed using PNN. As the consequence part of the EFPNN, the development of the genetically optimized PNN(gPNN) dwells on two general optimization mechanism: the structural optimization is realized via GAs whereas in case of the parametric optimization we proceed with a standard least square method-based learning. To evaluate the performance of the EFPNN, the models are experimented with the use of several representative numerical examples. A comparative analysis shows that the proposed EFPNN are models with higher accuracy as well as more superb predictive capability than other intelligent models presented previously.

An Experimental Study on the Application of Measuring Method of Water Content for Quality Control of Concrete (콘크리트 품질관리를 위한 단위수량 측정 기법의 적용성에 관한 실험적 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Lee, Do-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2007
  • Recently, the concern on the receipt of poor ready-mixed concrete in the construction field and the durability of concrete has been increased. Based on the such background, a large number of measuring methods of water content for fresh concrete have been developed and enforced in a developed country. In this study, to investigate practicality for quality control of ready-mixed concrete among various water content measurement techniques, microwave range method, air meter method and capacitance measurement method as measuring methods of water content were selected. Then, it was evaluated estimating performance of water content according to the change of binder types, fine aggregate types, absorption ratio, water content and water-binder ratio in series I and II. Also, it was examined influence on error occurrence of water content according to change of properties of used materials in series III. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of water content to quality control of ready-mixed concrete in construction field.

A Study on the Fabrication of Lithium Iron Oxide Electrode and its Cyclic Voltammetric Characteristics (리튬-철 산화물 전극의 제조 및 전류전위 순환 특성에 관한 연구)

  • Jeong Won-Joong;Ju Jeh-Beck;Sohn Tai-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.156-162
    • /
    • 1999
  • Various types of iron oxide based materials as a cathode of lithium secondary battery have been prepared and their electrochemical characteristics have been also observed. In order to understand the fundamental characteristics of iron oxide electrode, three kinds of iron oxides such as iron oxides formed by direct oxidation of iron plate or iron powders and FeOOH powders were tested with cyclic voltammetry. The oxidation and reduction peaks due to the reaction of intercalation and deintercalation were not observed for the iron oxide prepared with iron plate and FeOOH powders. In case of iron oxide prepared from iron powders, only one reduction peak was observed. A layered form of $LiFeO_2$ was synthesized directly from $FeCl_3\cdot6H_2O,\;NaOH\;and\;LiOH$ and LiOH by hydrothermal reaction. The effect of NaOH on the electrode performance was examined. When increasing NaOH, it provides the electrode with less discharge capacity and efficiency, however, decreasing rate of discharge capacity became smaller. $LiFeO_2$ synthesized with the molar ratio of $NaOH/FeCl_3/LiOH$, 2/1/7 showed the largest capacity, but the discharging efficiency was sharply decreased after 30 cycles.

A Fundamental Study on the Development of Highly Efficient Models of Rain Shelter (비가림시설의 효율적 형태 개발에 관한 기초 연구)

  • 손정익;김문기;권영삼;남상운;윤남균
    • Journal of Bio-Environment Control
    • /
    • v.4 no.1
    • /
    • pp.32-42
    • /
    • 1995
  • Cultivation using rain shelter is very popular in summer because rain shelter has a simple structure using less materials than any other regular greenhouse. Although it has a main advantage of easy construction in terms of labour, time and cost, it has some disadvantage of poor ventilation and rain fall inflow. Therefore, the rain shelters being able to overcome the problems, to some extent, are necessary to propagate for practical purpose. Three characteristic types of rain shelter were analyzed using measured and simulated environment data. Type 1 was a conventional type with an arched roof, and Type 2 and Type 3 were improved ones which were designed to have three arched roofs and three sawtooth like roofs with the openings for ventilation, respectively. The distribution of inside temperature measured was relatively uniform in Type 2 and 3 by the natural ventilation through the openings of the roof compared to Type 1 which had no openings. The relative light transmittance measured in Type 2 and 3 showed lower than that in Type 1, which suppressed the rise of inside temperature, For more accurate comparison, the differences between inside and outside temperatures to various wind speeds were calculated by the model. The difference in Type 1 was the greatest at lower wind speed below 1 ㎧, that is, the highest in inside temperature, but decreased rapidly as wind speed increased above 1 ㎧. Measured temperatures generally showed the same trends as calculated ones by the model. As a whole, the improved rain shelters(Type 2 and 3) showed better performance than the conventional one in ventilation as well as inside temperature.

  • PDF

HeLa Cell Culture on Nanoimprinted Patterns Using Conducting Polymer (전도성 고분자 나노임프린트 패턴 상의 HeLa 세포 배양)

  • Ahn, Junhyoung;Park, Kyungsook;Lee, Suok;Jung, Sanghee;Lim, Hyungjun;Shin, Yong-Beom;Lee, JaeJong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.63-67
    • /
    • 2017
  • In bioscience and biotechnology, the research of fundamental life mechanisms and their diseases caused by insufficiency is important. The study of a whole organism is difficult and sometimes impossible because of DNA, RNA, proteins, cellular organelles, various cells, and organs. Cell cultures can provide a simple method for researching cellular mechanisms and conditions, both in terms of physiological performance, and in response to chemical stimulation. According to conventional cell culture methodology, the flat surface is used with surface treatments for cell adhesion on the surface. Micro- and nanoscale patterns have been developed with chemical and biochemical modifications for cell immobilization. In this study, HeLa cell culture on nanostructures patterns was studied, including the 300 nm line and 150 nm pillar structures, using nanoimprint lithography and pyrrole as a biocompatible conducting polymer.

A Study on the Awareness of Fire Safety and Evacuation Guide System (화재안전의식 및 피난유도 시스템에 대한 연구)

  • Baek, Eun-Sun;Baek, Geon-Jong;Shin, Hoon;Song, Min-Jeong;Kook, Chan;Kim, Sun-Woo
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.45-53
    • /
    • 2010
  • The purpose of this study is to find out the most effective evacuation alarm sound which is the one of the most important element of the evacuation guidance system as a fundamental mechanism to minimize the damages of a fire. In this regard, a survey was conducted against the firefighting officers and the general public with questions about the general awareness of fire and their preference to various kinds of fire alarm sounds. The result showed that 1) even though the awareness of the interviewees on fire was improving while there were in familiar places like homes or works. But, when they were situated in unfamiliar locations, the fire safety awareness could not be deemed to be strong. This in turn calls for the education of the public and improvement of the existing policies for the enhancement of the fire related safety awareness in unfamiliar environments. 2) For the question about the possible time they could survive in a fire or the time required for safe evacuation, it turned out that the interviewees were thinking of the time required for evacuation to be short, which calls for proper actions. 3) When the visibility in a fire situation is highly limited, the most preferred answer for the alarm sound was a female voice, saying "The emergency exit is this way," accompanies with flashing lights of sirens for the emergency evacuation guidance.

Analysis of the Maximum Heat Release Rate in Accordance with the Test Method of the Flame Retardant Performance for Pipe Insulation (배관용 보온재의 난연 성능 시험방법에 따른 최대 발열량 분석)

  • You, Woo Jun;Park, Jung Wook;Sin, Yeon Je;Park, Hyeong Gyu;Lim, Ohk Kun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.18-25
    • /
    • 2020
  • In this study, the heat release rate of pipe insulation is analyzed by considering the installation status in accordance with the standards ISO 20632 and NFPA 274. The flame retardation rate was evaluated for six types of test samples: polyethylene foam covered with beaten silver (PE(S)), PE foam tapped (PE(N)), elastomeric closed cell thermal insulation (rubber), Japanese PE foam (PE(J)), Japanese polyurethane foam (PU(J)), and Japanese styro form (ST(J)) by EN 13501-1 and fire growth curve. The results show that PU(J), PE(J), and PE(N) were Class E and ultra-fast, NFPA 274 test standards for Class D and Fast, and PE(S) by ISO 20632 were Class C and Slow, and Rubber and ST(J) were Classes and Low. However, the changes in the time-averaged maximum heat release rate for each test standard (ISO 20632 and NFPA 274) to evaluate the flame retardation rate differed among identical materials. This means that the fundamental study is necessary to analyze the more accurate reasons.