• Title/Summary/Keyword: Functional lens

Search Result 54, Processing Time 0.022 seconds

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF

A study on the polarized spectacle lens with photochromic UV blocking function of refractive index 1.60 (굴절률 1.60 광변색성 자외선 차단기능을 갖는 편광안경렌즈 연구)

  • Han, Doo-Hee
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.147-152
    • /
    • 2018
  • A polarizing spectacle lens having a perfect blocking of ultraviolet light and a partial blocking of blue light and having photochromic properties has been developed. It is a functional spectacle lens which can be used as a spectacle lens in the daytime, which plays a role of sunglass in a space with strong ultraviolet rays, dramatically reducing glare caused by late-night driving or reflected light. Photochromism was recovered in 0.5 second dark reaction and 3 seconds recovery time. The polarization function was about 95%. Ultraviolet rays were completely blocked and blue light was reduced by about 30%. A lens that combines photochromic and UV blocking and polarization functions is the first attempt at investigating the domestic market.

Analysis of Physical and Antibacterial Properties of Functional Silicone Hydrogel Ophthalmic Lenses Containing Graphene Groups

  • Su-Mi Shin;Hye-In Park;A-Young Sung
    • Korean Journal of Materials Research
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • The physical and antibacterial properties of ophthalmic lenses fabricated by copolymerization with hydrogel monomers using two types of graphene were measured, and their usability as contact lens materials was analyzed. For polymerization, silicone monomers, including SID-OH, 3-(methacryloxy)propyl tris(trimethylsiloxy)silane, and decamethylcyclopentasiloxane, were used, and N,N-dimethylacetamide, ethylene glycol dimethacrylate as a crosslinking agent, and azobisisobutyronitrile as an initiator were added. Also, graphene oxide nanoparticle (GON) and graphene nanoplate (GNP) were used as an additive, and the physical properties of the lenses fabricated after copolymerization were evaluated. The fabricated lenses satisfied the basic physical properties of general hydrogel contact lenses and showed the characteristics of lenses with high water content, and the disadvantage of very weak durability, due to low tensile strength. However, it was confirmed that the tensile strength and antibacterial properties were greatly improved by adding GON and GNP. With GON, the oxygen permeability and refractive index of the fabricated lenses were slightly improved. Therefore, it was determined that the graphene materials used in this study can be used in various ways as a contact lens material.

Preparation and Analysis of Functional Hydrogel Lenses Using Cerium Iron Hydroxide Nanoparticles

  • Shin, Su-Mi;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.13 no.1
    • /
    • pp.13-18
    • /
    • 2020
  • This study used cerium iron hydroxide nanoparticle with HEMA (2-hydroxyethyl methacrylate), the cross-linker EGDMA (ethylene glycol dimethacrylate), NVP (N-vinyl-2-pyrrolidone) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Also, the physical properties of the prepared lenses were compared, and their applicability as polymers for ophthalmic materials was experimented. The results of the measurement showed that the UV blocking rate and the wettability increased with the cerium iron hydroxide nanoparticles addition ratio, and the refractive index and water content were not affected. Thus, the produced copolymer is expected to be useful as a functional contact lens material while satisfying the basic physical properties of the hydrogel contact lens.

Polymerization and Physical Property Assessment of Optical Lens Materials Containing Amide Group

  • Lee, Min-Jae;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.2
    • /
    • pp.113-117
    • /
    • 2018
  • The basic hydrogel lens with addition of N,N-dimethylacrylamide (DMA) and N-methyl-N-vinylacetamide (NMV) were manufactured. The optical and physical characteristics of ophthalmic lens were evaluated by measuring water content, oxygen permeability (Dk), refractive index and optical transmittance. The water content & oxygen permeability (Dk) of sample containing Ref., DMA group and NMV group was in the average of 34.48%, 35.54~49.19% & $13.003{\sim}18.468{\times}10^{-11}(cm^2/sec)$($mlO_2/ml{\times}mmHg$) and 36.28~44.95% & $12.270{\sim}16.883{\times}10^{-11}(cm^2/sec)$ ($mlO_2/ml{\times}mmHg$), respectively. And also, refractive index of the sample containing Ref., DMA group and NMV group was in the average of 1.4350, 1.4330~1.4131 and 1.4335~1.4195, respectively. Standard hydrogel monomer containing DMA and NMV was expected to be used usefully as a material for fabricating hydrophilic functional ophthalmic lens.

Development of Hyaluronic Acid-Functionalized Hydrogel Lens and Characterization of Physical Properties and Lysozyme Adsorption (Hyaluronic acid의 첨가방법에 따른 하이드로겔 콘택트렌즈의 물리적 특성과 lysozyme 흡착량 비교)

  • Lim, Hwa-lim;Kim, Ho-joong;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.285-291
    • /
    • 2015
  • Purpose: The hydrogel lenses have been functionalized with HA(Hyaluronic Acid) using two different methods: construction of an IPN(Interpenetrating Polymer Networks) and formation of CCB(Chemical Covalent Bonding). The lysozyme adsorption and physical properties such as optical transmittance and water content of the hydrogel lenses have been investigated in order to determine whether method is suitable for the application potentials in contact lens industry. Methods: HA have been added to the hydrogel lenses prepared in the Lab using the two different method, e.g. IPN and CCB. The optical transmittance was measured in the wavelength range of 300~800 nm. The water content was measured by the gravimetric method using 0.9% NaCl saline solution. The amounts of adsorbed lysozyme on the contact lenses was analyzed by HPLC after incubation for 12h in artificial tears. Results: The water content of the HA added hydrogel contact lenses was increased, and the lens made by IPN method showed higher water content than the lens made by CCB method. The optical transmittance was over 90% both before and after addition of HA. Comparing the lysozyme adsorption reduction ratio, contact lens manufactured by IPN method was 60.0%, and the lens made by CCB method was 40.4%. Conclusions: CCB method is appropriate to distribute the functional material evenly throughout the lens, whereas IPN method is effective for the case of giving the functionality on the lens surface without phase separation.

Modeling for New Type Backlight Units (신개념 백라이트유닛 모델링)

  • Lee, Kwang-Hoon;Jee, Seung-Hyun;Kim, Soo-Hyun;Yoon, Young-Soo;Kim, Soo-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.2
    • /
    • pp.41-45
    • /
    • 2010
  • In order to obtain thinner and brighter backlight units (BLU), we simulated a new-type backlight unit. A micro-lens array sheet was formed on the upper plane of the light guide plate (LGP) comprising the backlight unit. Also, in order to match with the LGP, we simulated a functional optical sheet. The conventional BLU uses one LGP and four optical sheets, but we simulated a BLU that uses one optical sheet. Simulation results have revealed that our BLU can achieve the same luminance and 30% better view angle as compared with conventional ones.

Preparation and Physical Properties of Silicone Hydrogel Ophthalmic Lens Containing Hydrophilic Monomer

  • Lee, Min-Jae;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.4
    • /
    • pp.261-266
    • /
    • 2016
  • The major physical characteristics of macromolecules used in silicone hydrogel ophthalmic lenses include optical transmittance, oxygen permeability, water content, and refractive index. For the preparation of highly functional silicone hydrogel lens materials, two silicone monomers were used in the presence of 2-hydroxyethyl methacrylate (HEMA) and hydroxypropyl methacrylate (HPMA). The samples containing HEMA and HPMA had oxygen transmissibility (Dk) values in the range of 73.38–50.98 × 10-11 (cm2/s) (mLO2/mL×mmHg) and 71.94–42.80 × 10-11 (cm2/s) (mLO2/mL×mmHg), respectively. Furthermore, the water contents of samples containing HEMA and HPMA were in the range of 32.73–34.67% and 31.94–33.74%, respectively, and the refractive indices were in the range of 1.4348–1.4364 and 1.4385–1.4407, respectively. Thus, silicone monomers containing HEMA and HPMA are expected to be useful for fabricating high-oxygen-permeability silicon hydrogel ophthalmic lenses.